Volumn 79, Issue 1, 2009, Pages 190-200

Effect of wind parks with doubly fed asynchronous generators on small-signal stability

Author keywords

Doubly fed asynchronous generator (DFAG); Inter area oscillations; Small signal stability; Wind power

Indexed keywords

CIRCUIT OSCILLATIONS; CONCURRENCY CONTROL; ELECTRIC POWER SYSTEM INTERCONNECTION; ELECTRIC POWER SYSTEMS; ELECTRIC POWER TRANSMISSION NETWORKS; INTERCONNECTION NETWORKS; MOTION ESTIMATION; PARKS; POWER TRANSMISSION; REMOTE CONTROL; RENEWABLE ENERGY RESOURCES; SYSTEM STABILITY; TUNING; WIND POWER;

EID: 54049134008     PISSN: 03787796     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.epsr.2008.05.018     Document Type: Article
Times cited : (151)

References (30)
  • 1
    • 54049107053 scopus 로고    scopus 로고
    • Global wind energy council, http://www.gwec.net.
    • Global wind energy council, http://www.gwec.net.
  • 2
    • 54049151740 scopus 로고    scopus 로고
    • European union renewable energy road map, http://europa.eu/scadplus/leg/en/lvb/l27065.htm.
    • European union renewable energy road map, http://europa.eu/scadplus/leg/en/lvb/l27065.htm.
  • 3
    • 54049088313 scopus 로고    scopus 로고
    • P. Pourbeik (convener), CIGRE WG C4.601, Modeling and dynamic behavior of wind generation as it relates to power system control and dynamic performance, CIGRE Technical Brochure No. 328, August 2007.
    • P. Pourbeik (convener), CIGRE WG C4.601, Modeling and dynamic behavior of wind generation as it relates to power system control and dynamic performance, CIGRE Technical Brochure No. 328, August 2007.
  • 4
    • 54049104127 scopus 로고    scopus 로고
    • Large-scale integration of wind energy in the European power supply, Tech. rep., European Wind Energy Association, available on-line at http://www.ewea.org/fileadmin/ewea_documents/documents/publications/grid/051215_Grid_report.pdf, 2005.
    • Large-scale integration of wind energy in the European power supply, Tech. rep., European Wind Energy Association, available on-line at http://www.ewea.org/fileadmin/ewea_documents/documents/publications/grid/051215_Grid_report.pdf, 2005.
  • 6
    • 0038519499 scopus 로고    scopus 로고
    • Dynamic modeling of doubly fed induction generator wind turbines
    • Ekanayake J.B., Holdsworth L., Wu X., and Jenkins N. Dynamic modeling of doubly fed induction generator wind turbines. IEEE Trans. Power Syst. 18 2 (2003) 803-809
    • (2003) IEEE Trans. Power Syst. , vol.18 , Issue.2 , pp. 803-809
    • Ekanayake, J.B.1    Holdsworth, L.2    Wu, X.3    Jenkins, N.4
  • 7
    • 84861514215 scopus 로고    scopus 로고
    • Doubly-fed induction machine models for stability assessment of wind farms
    • Bologna, Italy
    • Pöller M.A. Doubly-fed induction machine models for stability assessment of wind farms. Proceedings of the IEEE PowerTech (2003), Bologna, Italy
    • (2003) Proceedings of the IEEE PowerTech
    • Pöller, M.A.1
  • 8
    • 20544446440 scopus 로고    scopus 로고
    • Doubly fed induction generator model for transient stability analysis
    • Ledesma P., and Usaola J. Doubly fed induction generator model for transient stability analysis. IEEE Trans. Energy Convers. 20 2 (2005) 388-397
    • (2005) IEEE Trans. Energy Convers. , vol.20 , Issue.2 , pp. 388-397
    • Ledesma, P.1    Usaola, J.2
  • 9
    • 33244493104 scopus 로고    scopus 로고
    • Modeling of the wind turbine with a doubly fed induction generator for grid integration studies
    • Lei Y., Mullane A., Lightbody G., and Yacamini R. Modeling of the wind turbine with a doubly fed induction generator for grid integration studies. IEEE Trans. Energy Convers. 21 1 (2006) 257-264
    • (2006) IEEE Trans. Energy Convers. , vol.21 , Issue.1 , pp. 257-264
    • Lei, Y.1    Mullane, A.2    Lightbody, G.3    Yacamini, R.4
  • 10
    • 34547844063 scopus 로고    scopus 로고
    • Modelling analysis of transient stability simulation with high penetration of grid-connected wind farms of dfig type
    • Shi L., Xu Z., Hao J., and Ni Y. Modelling analysis of transient stability simulation with high penetration of grid-connected wind farms of dfig type. Wind Energy 10 4 (2007) 303-320
    • (2007) Wind Energy , vol.10 , Issue.4 , pp. 303-320
    • Shi, L.1    Xu, Z.2    Hao, J.3    Ni, Y.4
  • 11
    • 34548019038 scopus 로고    scopus 로고
    • Modeling of wind turbines based on doubly-fed induction generators for power system stability studies
    • Erlich I., Kretschmann J., Fortmann J., Mueller-Engelhardt S., and Wrede H. Modeling of wind turbines based on doubly-fed induction generators for power system stability studies. IEEE Trans. Power Syst. 22 3 (2007) 909-919
    • (2007) IEEE Trans. Power Syst. , vol.22 , Issue.3 , pp. 909-919
    • Erlich, I.1    Kretschmann, J.2    Fortmann, J.3    Mueller-Engelhardt, S.4    Wrede, H.5
  • 12
    • 33748563112 scopus 로고    scopus 로고
    • Rotor flux magnitude and angle control strategy for doubly fed induction generators
    • Anaya-Lara O., Hughes F.M., Jenkins N., and Strbac G. Rotor flux magnitude and angle control strategy for doubly fed induction generators. Wind Energy 9 5 (2006) 479-495
    • (2006) Wind Energy , vol.9 , Issue.5 , pp. 479-495
    • Anaya-Lara, O.1    Hughes, F.M.2    Jenkins, N.3    Strbac, G.4
  • 13
    • 34249792921 scopus 로고    scopus 로고
    • Reactive power control strategies for dfig-based plants
    • Kayi{dotless}kçi{dotless} M., and Milanović J.V. Reactive power control strategies for dfig-based plants. IEEE Trans. Energy Convers. 22 2 (2007) 389-396
    • (2007) IEEE Trans. Energy Convers. , vol.22 , Issue.2 , pp. 389-396
    • Kayikçi, M.1    Milanović, J.V.2
  • 14
    • 33947613668 scopus 로고    scopus 로고
    • Control of doubly fed induction wind generator under unbalanced grid voltage conditions
    • Brekken T.K.A., and Mohan N. Control of doubly fed induction wind generator under unbalanced grid voltage conditions. IEEE Trans. Energy Convers. 22 1 (2007) 129-135
    • (2007) IEEE Trans. Energy Convers. , vol.22 , Issue.1 , pp. 129-135
    • Brekken, T.K.A.1    Mohan, N.2
  • 16
    • 34548237470 scopus 로고    scopus 로고
    • Modal analysis of grid-connected doubly fed induction generators
    • Mei F., and Pal B. Modal analysis of grid-connected doubly fed induction generators. IEEE Trans. Energy Convers. 22 3 (2007) 728-736
    • (2007) IEEE Trans. Energy Convers. , vol.22 , Issue.3 , pp. 728-736
    • Mei, F.1    Pal, B.2
  • 17
    • 33645003355 scopus 로고    scopus 로고
    • Steady-state stability analysis of doubly-fed induction generators under decoupled p-q control
    • Banakar H., Luo C., and Ooi B.T. Steady-state stability analysis of doubly-fed induction generators under decoupled p-q control. IEE Proc. Electr. Power Appl. 153 2 (2006) 300-306
    • (2006) IEE Proc. Electr. Power Appl. , vol.153 , Issue.2 , pp. 300-306
    • Banakar, H.1    Luo, C.2    Ooi, B.T.3
  • 18
    • 34547797926 scopus 로고    scopus 로고
    • Small signal stability analysis and optimal control of a wind turbine with doubly fed induction generator
    • Wu F., Zhang X.-P., Godfrey K., and Ju P. Small signal stability analysis and optimal control of a wind turbine with doubly fed induction generator. IET Gener. Transm. Distrib. 1 5 (2007) 751-760
    • (2007) IET Gener. Transm. Distrib. , vol.1 , Issue.5 , pp. 751-760
    • Wu, F.1    Zhang, X.-P.2    Godfrey, K.3    Ju, P.4
  • 19
    • 0041888150 scopus 로고    scopus 로고
    • The impact of large scale wind power generation on power system oscillations
    • Slootweg J.G., and Kling W.L. The impact of large scale wind power generation on power system oscillations. Electr. Power Syst. Res. 67 1 (2003) 9-20
    • (2003) Electr. Power Syst. Res. , vol.67 , Issue.1 , pp. 9-20
    • Slootweg, J.G.1    Kling, W.L.2
  • 21
    • 33847361534 scopus 로고    scopus 로고
    • Impact of wind farms on a power system. An eigenvalue analysis approach
    • Fernandez R.D., Mantz R.J., and Battaiotto P.E. Impact of wind farms on a power system. An eigenvalue analysis approach. Renew. Energy 32 10 (2007) 1676-1688
    • (2007) Renew. Energy , vol.32 , Issue.10 , pp. 1676-1688
    • Fernandez, R.D.1    Mantz, R.J.2    Battaiotto, P.E.3
  • 24
    • 25144509486 scopus 로고    scopus 로고
    • Large-scale wind power integration in Norway and impact on damping in the Nordic grid
    • Hagstrøm E., Norheim I., and Uhlen K. Large-scale wind power integration in Norway and impact on damping in the Nordic grid. Wind Energy 8 3 (2005) 375-384
    • (2005) Wind Energy , vol.8 , Issue.3 , pp. 375-384
    • Hagstrøm, E.1    Norheim, I.2    Uhlen, K.3
  • 25
    • 33947625133 scopus 로고    scopus 로고
    • Effect of variable speed wind turbine generator on stability of a weak grid
    • Muljadi E., Butterfield C.P., Parsons B., and Ellis A. Effect of variable speed wind turbine generator on stability of a weak grid. IEEE Trans. Energy Convers. 22 1 (2007) 29-36
    • (2007) IEEE Trans. Energy Convers. , vol.22 , Issue.1 , pp. 29-36
    • Muljadi, E.1    Butterfield, C.P.2    Parsons, B.3    Ellis, A.4
  • 27
    • 0030146394 scopus 로고    scopus 로고
    • Doubly fed induction generator using back-to-back pwm converters and its application to variable-speed wind-energy generation
    • Pena R., Clare J.C., and Asher G.M. Doubly fed induction generator using back-to-back pwm converters and its application to variable-speed wind-energy generation. IEE Proc. Electr. Power Appl. 143 3 (1996) 231-241
    • (1996) IEE Proc. Electr. Power Appl. , vol.143 , Issue.3 , pp. 231-241
    • Pena, R.1    Clare, J.C.2    Asher, G.M.3
  • 28
    • 0036843254 scopus 로고    scopus 로고
    • An aggregate model of a grid-connected, large-scale, offshore wind farm for power stability investigations-importance of windmill mechanical system
    • Akhmatov V., and Knudsen H. An aggregate model of a grid-connected, large-scale, offshore wind farm for power stability investigations-importance of windmill mechanical system. Int. J. Electr. Power Energy Syst. 24 9 (2002) 709-717
    • (2002) Int. J. Electr. Power Energy Syst. , vol.24 , Issue.9 , pp. 709-717
    • Akhmatov, V.1    Knudsen, H.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.