메뉴 건너뛰기




Volumn 44, Issue 4, 2013, Pages 304-312

A miniaturized analyzer capable of white-blood- cell and differential analyses during spaceflight

Author keywords

Hematology analyzer; Spaceflight

Indexed keywords

ANALYTICAL EQUIPMENT; ARTICLE; BASOPHIL; COSMONAUT; DIAGNOSTIC ACCURACY; EOSINOPHIL; FLOW CYTOMETER; GRANULOCYTE; GRAVITY; HEALTH HAZARD; HEMATOLOGY ANALYZER; HUMAN; HYDRODYNAMICS; LABORATORY; LABORATORY DEVICE; LAMINAR FLOW; LEUKOCYTE; LEUKOCYTE DIFFERENTIAL COUNT; LYMPHOCYTE; MEDICAL RESEARCH; MICROGRAVITY; MONOCYTE; NORMAL HUMAN; SPACE FLIGHT; VALIDATION STUDY; VENOUS BLOOD; WBC DIFFERENTIAL ANALYZER; WEIGHTLESSNESS;

EID: 84893118991     PISSN: 00075027     EISSN: 19437730     Source Type: Journal    
DOI: 10.1309/LMD3THAYCHICF2XT     Document Type: Article
Times cited : (5)

References (14)
  • 1
    • 67650759549 scopus 로고    scopus 로고
    • Acclimation during space flight: Effects on human physiology
    • Williams D, Kuipers A, Mukai C, Thirsk R. Acclimation during space flight: effects on human physiology. Can Med Assoc J. 2009;180(13):1317-1323.
    • (2009) Can Med Assoc J. , vol.180 , Issue.13 , pp. 1317-1323
    • Williams, D.1    Kuipers, A.2    Mukai, C.3    Thirsk, R.4
  • 2
    • 70350741504 scopus 로고    scopus 로고
    • Could spaceflightassociated immune system weakening preclude the expansion of human presence beyond earth's orbit
    • Gueguinou N, Huin-Schohn C, Bascove M, et al. Could spaceflightassociated immune system weakening preclude the expansion of human presence beyond Earth's orbit? J Leukoc Biol. 2009;86(5):1027-1038.
    • (2009) ? J Leukoc Biol. , vol.86 , Issue.5 , pp. 1027-1038
    • Gueguinou, N.1    Huin-Schohn, C.2    Bascove, M.3
  • 3
    • 70350719491 scopus 로고    scopus 로고
    • Immune system dysregulation during spaceflight: Clinical risk for exploration-class missions
    • Crucian B, Sams C. Immune system dysregulation during spaceflight: clinical risk for exploration-class missions. J Leukoc Biol. 2009;86(5):1017-1018.
    • (2009) J Leukoc Biol. , vol.86 , Issue.5 , pp. 1017-1018
    • Crucian, B.1    Sams, C.2
  • 6
    • 43249130506 scopus 로고    scopus 로고
    • Asymptomatic reactivation and shed of infectious varicella zoster virus in astronauts
    • DOI 10.1002/jmv.21173
    • Cohrs RJ, Mehta SK, Schmid DS, Gilden DH, Pierson DL. Asymptomatic reactivation and shed of infectious varicella zoster virus in astronauts. J Med Virol. 2008;80(6):1116-1122. (Pubitemid 351657028)
    • (2008) Journal of Medical Virology , vol.80 , Issue.6 , pp. 1116-1122
    • Cohrs, R.J.1    Mehta, S.K.2    Schmid, D.S.3    Gilden, D.H.4    Pierson, D.L.5
  • 7
    • 0033814547 scopus 로고    scopus 로고
    • Laboratory outreach: Student assessment of flow cytometer fluidics in zerogravity
    • Crucian B, Norman J, Brentz J, Pietrzyk R, Sams C. Laboratory outreach: student assessment of flow cytometer fluidics in zerogravity. Lab Med. 2000:31(10):569-573.
    • (2000) Lab Med , vol.31 , Issue.10 , pp. 569-573
    • Crucian, B.1    Norman, J.2    Brentz, J.3    Pietrzyk, R.4    Sams, C.5
  • 9
    • 84893133932 scopus 로고    scopus 로고
    • NASA Space Flight Human System Standard-Volume 1: Crew Health (NASA-STD-3000 and JSC 26882)., Chap. 7
    • NASA Space Flight Human System Standard-Volume 1: Crew Health (NASA-STD-3000 and JSC 26882). Space Flight Health Requirements Document. 2009;Vol. 1, Chap. 7.
    • (2009) Space Flight Health Requirements Document , vol.1
  • 10
    • 74049097841 scopus 로고    scopus 로고
    • Point-of-care method for total white cell count: An evaluation of the hemocue wbc device
    • Osei-Bimpong A, Jury C, McLean R, Lewis SM. Point-of-care method for total white cell count: an evaluation of the HemoCue WBC device. Int J Lab Hematol. 2009;31(6):657-664.
    • (2009) Int J Lab Hematol , vol.31 , Issue.6 , pp. 657-664
    • Osei-Bimpong, A.1    Jury, C.2    Mclean, R.3    Lewis, S.M.4
  • 11
    • 0024521543 scopus 로고
    • A concordance correlation coefficient to evaluate reproducibility
    • Lin LI-K . A concordance correlation coefficient to evaluate reproducibility. Biometrics. 1989;45:255-268.
    • (1989) Biometrics , vol.45 , pp. 255-268
    • Lin, L.I.-K.1
  • 12
    • 84975207356 scopus 로고    scopus 로고
    • A note on the concordance correlation coefficient
    • Lin L. A note on the concordance correlation coefficient. Biometrics.2000;56:324-325.
    • (2000) Biometrics , vol.56 , pp. 324-325
    • Lin, L.1
  • 13
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • PII S0140673686908378
    • Bland, JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986;1:307-310. (Pubitemid 16134762)
    • (1986) Lancet , vol.1 , Issue.8476 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 14
    • 80052480344 scopus 로고    scopus 로고
    • Finger-stick complete blood counts: Comparison between venous and capillary blood
    • Rao LV, Moiles D, Snyder M. Finger-stick complete blood counts: Comparison between venous and capillary blood. Point of Care. 2011;10:120-122.
    • (2011) Point of Care , vol.10 , pp. 120-122
    • Rao, L.V.1    Moiles, D.2    Snyder, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.