메뉴 건너뛰기




Volumn 55, Issue 1, 2014, Pages

Clinical significance of nonhabitual seizures during intracranial EEG monitoring

Author keywords

Atypical seizures; Epilepsy surgery; Invasive EEG; Presurgical evaluation; Subdural EEG

Indexed keywords

ADOLESCENT; ADULT; ARTICLE; CHILD; CLINICAL STUDY; COMPUTER ASSISTED TOMOGRAPHY; CONTROLLED STUDY; DISEASE MARKER; ELECTRODE; ELECTROENCEPHALOGRAM; ELECTROENCEPHALOGRAPHY; EPILEPSY; FEMALE; HUMAN; MACHINE; MAJOR CLINICAL STUDY; MALE; NONHABITUAL SEIZURE; PREOPERATIVE EVALUATION; PRESCHOOL CHILD; PRIORITY JOURNAL; PROCEDURAL SITE REACTION; SCHOOL CHILD; SEIZURE; SYMPTOM; TELEMETRY; TEMPORAL LOBE EPILEPSY;

EID: 84892919757     PISSN: 00139580     EISSN: 15281167     Source Type: Journal    
DOI: 10.1111/epi.12462     Document Type: Article
Times cited : (12)

References (12)
  • 1
    • 80053573914 scopus 로고    scopus 로고
    • Iatrogenic seizures during intracranial EEG monitoring
    • Khoury JA, Noe KH, Drazkowski JF, et al. Iatrogenic seizures during intracranial EEG monitoring. Epilepsia 2011; 52: e123-e125.
    • (2011) Epilepsia , vol.52
    • Khoury, J.A.1    Noe, K.H.2    Drazkowski, J.F.3
  • 2
    • 0029040143 scopus 로고
    • Hematoma-related seizures detected during subdural electrode monitoring
    • Malow BA, Sato S, Kufta CV, et al. Hematoma-related seizures detected during subdural electrode monitoring. Epilepsia 1995; 36: 733-735.
    • (1995) Epilepsia , vol.36 , pp. 733-735
    • Malow, B.A.1    Sato, S.2    Kufta, C.V.3
  • 3
    • 10844225129 scopus 로고    scopus 로고
    • Nonhabitual seizures in patients with implanted subdural electrodes
    • Fountas KN, King DW, Jenkins PD, et al. Nonhabitual seizures in patients with implanted subdural electrodes. Stereotact Funct Neurosurg 2004; 82: 165-168.
    • (2004) Stereotact Funct Neurosurg , vol.82 , pp. 165-168
    • Fountas, K.N.1    King, D.W.2    Jenkins, P.D.3
  • 4
    • 35348908152 scopus 로고    scopus 로고
    • Subdural electrode-associated complications: A 20-year experience
    • Fountas KN, Smith JR,. Subdural electrode-associated complications: a 20-year experience. Stereotact Funct Neurosurg 2007; 85: 264-272.
    • (2007) Stereotact Funct Neurosurg , vol.85 , pp. 264-272
    • Fountas, K.N.1    Smith, J.R.2
  • 5
    • 6444245963 scopus 로고    scopus 로고
    • Complications of invasive video-EEG monitoring with subdural grid electrodes
    • Hamer HM, Morris HH, Mascha EJ, et al. Complications of invasive video-EEG monitoring with subdural grid electrodes. Neurology 2002; 58: 97-103.
    • (2002) Neurology , vol.58 , pp. 97-103
    • Hamer, H.M.1    Morris, H.H.2    Mascha, E.J.3
  • 6
    • 84876918297 scopus 로고    scopus 로고
    • Adverse events related to extraoperative invasive EEG monitoring with subdural grid electrodes: A systematic review and meta-analysis
    • Arya R, Mangano FT, Horn PS, et al. Adverse events related to extraoperative invasive EEG monitoring with subdural grid electrodes: a systematic review and meta-analysis. Epilepsia 2013; 54: 828-839.
    • (2013) Epilepsia , vol.54 , pp. 828-839
    • Arya, R.1    Mangano, F.T.2    Horn, P.S.3
  • 7
    • 84883277851 scopus 로고    scopus 로고
    • Nonconvulsive seizures after subarachnoid hemorrhage: Multimodal detection and outcomes
    • Claassen J, Perotte A, Albers D, et al. Nonconvulsive seizures after subarachnoid hemorrhage: Multimodal detection and outcomes. Ann Neurol 2013; 74: 53-64.
    • (2013) Ann Neurol , vol.74 , pp. 53-64
    • Claassen, J.1    Perotte, A.2    Albers, D.3
  • 8
    • 0020539853 scopus 로고
    • Falsely localizing ictal onsets with depth EEG telemetry during anticonvulsant withdrawal
    • Engel J Jr, Crandall PH,. Falsely localizing ictal onsets with depth EEG telemetry during anticonvulsant withdrawal. Epilepsia 1983; 24: 344-355.
    • (1983) Epilepsia , vol.24 , pp. 344-355
    • Engel, Jr.J.1    Crandall, P.H.2
  • 9
    • 84867194873 scopus 로고    scopus 로고
    • Long-term seizure outcome after resective surgery in patients evaluated with intracranial electrodes
    • Bulacio JC, Jehi L, Wong C, et al. Long-term seizure outcome after resective surgery in patients evaluated with intracranial electrodes. Epilepsia 2012; 53: 1722-1730.
    • (2012) Epilepsia , vol.53 , pp. 1722-1730
    • Bulacio, J.C.1    Jehi, L.2    Wong, C.3
  • 10
    • 74149083256 scopus 로고    scopus 로고
    • Predictive factors for outcome of invasive video-EEG monitoring and subsequent resective surgery in patients with refractory epilepsy
    • Carrette E, Vonck K, De Herdt V, et al. Predictive factors for outcome of invasive video-EEG monitoring and subsequent resective surgery in patients with refractory epilepsy. Clin Neurol Neurosurg 2010; 112: 118-126.
    • (2010) Clin Neurol Neurosurg , vol.112 , pp. 118-126
    • Carrette, E.1    Vonck, K.2    De Herdt, V.3
  • 11
    • 65849416717 scopus 로고    scopus 로고
    • Intracranial electroencephalography with subdural grid electrodes: Techniques, complications, and outcomes
    • Van Gompel JJ, Worrell GA, Bell ML, et al. Intracranial electroencephalography with subdural grid electrodes: techniques, complications, and outcomes. Neurosurgery 2008; 63: 498-505.
    • (2008) Neurosurgery , vol.63 , pp. 498-505
    • Van Gompel, J.J.1    Worrell, G.A.2    Bell, M.L.3
  • 12
    • 42949086992 scopus 로고    scopus 로고
    • Kaplan-Meier analysis on seizure outcome after epilepsy surgery: Do gender and race influence it?
    • Burneo JG, Villanueva V, Knowlton RC, et al. Kaplan-Meier analysis on seizure outcome after epilepsy surgery: do gender and race influence it? Seizure 2008; 17: 314-319.
    • (2008) Seizure , vol.17 , pp. 314-319
    • Burneo, J.G.1    Villanueva, V.2    Knowlton, R.C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.