메뉴 건너뛰기




Volumn 52, Issue 10, 2011, Pages

Iatrogenic seizures during intracranial EEG monitoring

Author keywords

Epilepsy; Intracranial electroencephalography; MRI; Seizures

Indexed keywords

ADULT; AGED; ARTICLE; BRAIN EDEMA; CLINICAL ARTICLE; ELECTRODE; ELECTROENCEPHALOGRAPHY; FEMALE; HUMAN; IATROGENIC SEIZURE; MALE; NEUROSURGERY; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; SEIZURE;

EID: 80053573914     PISSN: 00139580     EISSN: 15281167     Source Type: Journal    
DOI: 10.1111/j.1528-1167.2011.03161.x     Document Type: Article
Times cited : (7)

References (10)
  • 1
    • 76149086164 scopus 로고    scopus 로고
    • Clinically silent magnetic resonance imaging findings after subdural strip electrode implantation
    • Al-Otaibi FA, Alabousi A, Burneo JG, Lee DH, Parrent AG, Steven DA,. (2010) Clinically silent magnetic resonance imaging findings after subdural strip electrode implantation. J Neurosurg 112: 461-466.
    • (2010) J Neurosurg , vol.112 , pp. 461-466
    • Al-Otaibi, F.A.1    Alabousi, A.2    Burneo, J.G.3    Lee, D.H.4    Parrent, A.G.5    Steven, D.A.6
  • 3
    • 0020539853 scopus 로고
    • Falsely localizing ictal onsets with depth EEG telemetry during anticonvulsant withdrawal
    • Engel J, Crandall P,. (1983) Falsely localizing ictal onsets with depth EEG telemetry during anticonvulsant withdrawal. Epilepsia 24: 344-355. (Pubitemid 13106555)
    • (1983) Epilepsia , vol.24 , Issue.3 , pp. 344-355
    • Engel Jr., J.1    Crandall, P.H.2
  • 4
    • 35348908152 scopus 로고    scopus 로고
    • Subdural electrode-associated complications: A 20-year experience
    • DOI 10.1159/000107358
    • Fountas KN, Smith JR,. (2007) Subdural electrode-associated complications: a 20 year experience. Stereotact Funct Neurosurg 85: 264-272. (Pubitemid 47573722)
    • (2007) Stereotactic and Functional Neurosurgery , vol.85 , Issue.6 , pp. 264-272
    • Fountas, K.N.1    Smith, J.R.2
  • 7
    • 0029954478 scopus 로고    scopus 로고
    • Intracerebral depth electrode monitoring in partial epilepsy: The morbidity and efficacy of placement using magnetic resonance image-guided stereotactic surgery
    • DOI 10.1097/00006123-199608000-00018
    • Ross DA, Brunberg JA, Drury I, Thomas R,. (1996) Intracerebral depth electrode monitoring in partial epilepsy: the morbidity and efficacy of placement using magnetic resonance image-guided stereotactic surgery. Neurosurgery 39 (2): 327-334. (Pubitemid 26251554)
    • (1996) Neurosurgery , vol.39 , Issue.2 , pp. 327-334
    • Ross, D.A.1    Brunberg, J.A.2    Drury, I.3    Henry, T.R.4
  • 9
    • 0034858243 scopus 로고    scopus 로고
    • Spectrum of clinical and histopathologic responses to intracranial electrodes: From multifocal aseptic meningitis to multifocal hypersensitivity-type meningovasculitis
    • DOI 10.1046/j.1528-1157.2001.042007895.x
    • Stephan CL, Kepes JJ, SantaCruz K, Wilkinson SB, Fegley B, Osorio I,. (2001) Spectrum of clinical and histopathologic responses to intracranial electrodes: from multifocal meningitis to multifocal hypersensitivity-type meningovasculitis. Epilepsia 42: 895-901. (Pubitemid 32783099)
    • (2001) Epilepsia , vol.42 , Issue.7 , pp. 895-901
    • Stephan, C.L.1    Kepes, J.J.2    Santacruz, K.3    Wilkinson, S.B.4    Fegley, B.5    Osorio, I.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.