메뉴 건너뛰기




Volumn 202, Issue 2, 2014, Pages 437-442

Diameter measurement of vascular model on CT angiography using model-based iterative reconstruction: Effect of tube current on accuracy

Author keywords

CT angiography (CTA); Diameter measurement; Experimental studies; Iterative reconstruction

Indexed keywords

ALGORITHM; ARTICLE; BLOOD VESSEL DIAMETER; BLOOD VESSEL WALL; COMPUTED TOMOGRAPHIC ANGIOGRAPHY; COMPUTED TOMOGRAPHY SCANNER; FILTERED BACK PROJECTION; IMAGE DISPLAY; IMAGE SHARPNESS; INTERMETHOD COMPARISON; MEASUREMENT ACCURACY; MEASUREMENT ERROR; MODEL BASED ITERATIVE RECONSTRUCTION; PHANTOM; PRIORITY JOURNAL; RADIOLOGICAL PARAMETERS; TUBE CURRENT;

EID: 84892714397     PISSN: 0361803X     EISSN: 15463141     Source Type: Journal    
DOI: 10.2214/AJR.13.11039     Document Type: Article
Times cited : (6)

References (18)
  • 1
    • 35649025312 scopus 로고    scopus 로고
    • A three-dimensional statistical approach to improved image quality for multislice helical CT
    • Thibault JB, Sauer KD, Bouman CA, Hsieh J. A three-dimensional statistical approach to improved image quality for multislice helical CT. Med Phys 2007; 34:4526-4544
    • (2007) Med Phys , vol.34 , pp. 4526-4544
    • Thibault, J.B.1    Sauer, K.D.2    Bouman, C.A.3    Hsieh, J.4
  • 2
    • 79551517886 scopus 로고    scopus 로고
    • Fast model-based X-ray CT reconstruction using spatially nonhomogeneous ICD optimization
    • Yu Z, Thibault JB, Bouman CA, Sauer KD, Hsieh J. Fast model-based X-ray CT reconstruction using spatially nonhomogeneous ICD optimization. IEEE Trans Image Process 2011; 20:161-175
    • (2011) IEEE Trans Image Process , vol.20 , pp. 161-175
    • Yu, Z.1    Thibault, J.B.2    Bouman, C.A.3    Sauer, K.D.4    Hsieh, J.5
  • 3
    • 84871698536 scopus 로고    scopus 로고
    • Filtered back projection, adaptive statistical iterative reconstruction, and a model-based iterative reconstruction in abdominal CT: An experimental clinical study
    • Deák Z, Grimm JM, Treitl M, et al. Filtered back projection, adaptive statistical iterative reconstruction, and a model-based iterative reconstruction in abdominal CT: an experimental clinical study. Radiology 2013; 266:197-206
    • (2013) Radiology , vol.266 , pp. 197-206
    • Deák, Z.1    Grimm, J.M.2    Treitl, M.3
  • 4
    • 84871921772 scopus 로고    scopus 로고
    • Comparison of pure and hybrid iterative reconstruction techniques with conventional filtered back projection: Image quality assessment in the cervicothoracic region
    • Katsura M, Sato J, Akahane M, et al. Comparison of pure and hybrid iterative reconstruction techniques with conventional filtered back projection: image quality assessment in the cervicothoracic region. Eur J Radiol 2013; 82:356-360
    • (2013) Eur J Radiol , vol.82 , pp. 356-360
    • Katsura, M.1    Sato, J.2    Akahane, M.3
  • 5
    • 84873600660 scopus 로고    scopus 로고
    • Improved delineation of the anterior spinal artery with modelbased iterative reconstruction in CT angiography: A clinical pilot study
    • Machida H, Tanaka I, Fukui R, et al. Improved delineation of the anterior spinal artery with modelbased iterative reconstruction in CT angiography: a clinical pilot study. AJR 2013; 200:442-446
    • (2013) AJR , vol.200 , pp. 442-446
    • Machida, H.1    Tanaka, I.2    Fukui, R.3
  • 6
    • 84876036668 scopus 로고    scopus 로고
    • Image quality assessment of standard- and low-dose chest CT using filtered back projection, adaptive statistical iterative reconstruction, and novel model-based iterative reconstruction algorithms
    • Vardhanabhuti V, Loader RJ, Mitchell GR, Riordan RD, Roobottom CA. Image quality assessment of standard- and low-dose chest CT using filtered back projection, adaptive statistical iterative reconstruction, and novel model-based iterative reconstruction algorithms. AJR 2013; 200:545-552
    • (2013) AJR , vol.200 , pp. 545-552
    • Vardhanabhuti, V.1    Loader, R.J.2    Mitchell, G.R.3    Riordan, R.D.4    Roobottom, C.A.5
  • 7
    • 84876062454 scopus 로고    scopus 로고
    • Vascular diameter measurement in CT angiography: Comparison of model-based iterative reconstruction and standard filtered back projection algorithms in vitro
    • Suzuki S, Machida H, Tanaka I, Ueno E. Vascular diameter measurement in CT angiography: comparison of model-based iterative reconstruction and standard filtered back projection algorithms in vitro. AJR 2013; 200:652-657
    • (2013) AJR , vol.200 , pp. 652-657
    • Suzuki, S.1    Machida, H.2    Tanaka, I.3    Ueno, E.4
  • 8
    • 84887298651 scopus 로고    scopus 로고
    • Simulated 50% radiation dose reduction in coronary CT angiography using adaptive iterative dose reduction in three-dimensions (AIDR3D)
    • Chen MY, Steigner ML, Leung SW, et al. Simulated 50% radiation dose reduction in coronary CT angiography using adaptive iterative dose reduction in three-dimensions (AIDR3D). Int J Cardiovasc Imaging 2013; 29:1167-1175
    • (2013) Int J Cardiovasc Imaging , vol.29 , pp. 1167-1175
    • Chen, M.Y.1    Steigner, M.L.2    Leung, S.W.3
  • 11
    • 84866990354 scopus 로고    scopus 로고
    • Measurement of vascular wall attenuation: Comparison of CT angiography using model-based iterative reconstruction with standard filtered back-projection algorithm CT in vitro
    • Suzuki S, Machida H, Tanaka I, Ueno E. Measurement of vascular wall attenuation: comparison of CT angiography using model-based iterative reconstruction with standard filtered back-projection algorithm CT in vitro. Eur J Radiol 2012; 81:3348-3353
    • (2012) Eur J Radiol , vol.81 , pp. 3348-3353
    • Suzuki, S.1    Machida, H.2    Tanaka, I.3    Ueno, E.4
  • 12
    • 84864713607 scopus 로고    scopus 로고
    • Modelbased iterative reconstruction technique for radiation dose reduction in chest CT: Comparison with the adaptive statistical iterative reconstruction technique
    • Katsura M, Matsuda I, Akahane M, et al. Modelbased iterative reconstruction technique for radiation dose reduction in chest CT: comparison with the adaptive statistical iterative reconstruction technique. Eur Radiol 2012; 22:1613-1623
    • (2012) Eur Radiol , vol.22 , pp. 1613-1623
    • Katsura, M.1    Matsuda, I.2    Akahane, M.3
  • 13
    • 84874935300 scopus 로고    scopus 로고
    • Model-based iterative reconstruction technique for ul-tralow-dose chest CT: Comparison of pulmonary nodule detectability with the adaptive statistical iterative reconstruction technique
    • Katsura M, Matsuda I, Akahane M, et al. Model-based iterative reconstruction technique for ul-tralow-dose chest CT: comparison of pulmonary nodule detectability with the adaptive statistical iterative reconstruction technique. Invest Radiol 2013; 48:206-212
    • (2013) Invest Radiol , vol.48 , pp. 206-212
    • Katsura, M.1    Matsuda, I.2    Akahane, M.3
  • 14
    • 84864249070 scopus 로고    scopus 로고
    • Towards task-based assessment of CT performance: System and object MTF across different reconstruction algorithms
    • Richard S, Husarik DB, Yadava G, Murphy SN, Samei E. Towards task-based assessment of CT performance: system and object MTF across different reconstruction algorithms. Med Phys 2012; 39:4115-4122
    • (2012) Med Phys , vol.39 , pp. 4115-4122
    • Richard, S.1    Husarik, D.B.2    Yadava, G.3    Murphy, S.N.4    Samei, E.5
  • 15
    • 82455217279 scopus 로고    scopus 로고
    • Initial performance characterization of a clinical noise-suppressing reconstruction algorithm for MDCT
    • Noël PB, Fingerle AA, Renger B, Münzel D, Rummeny EJ, Dobritz M. Initial performance characterization of a clinical noise-suppressing reconstruction algorithm for MDCT. AJR 2011; 197:1404-1409
    • (2011) AJR , vol.197 , pp. 1404-1409
    • Noël, P.B.1    Fingerle, A.A.2    Renger, B.3    Münzel, D.4    Rummeny, E.J.5    Dobritz, M.6
  • 16
    • 80053922582 scopus 로고    scopus 로고
    • Coronary CT angiography: Image quality, diagnostic accuracy, and potential for radiation dose reduction using a novel iterative image reconstruction technique - comparison with traditional filtered back projection
    • Moscariello A, Takx RA, Schoepf UJ, et al. Coronary CT angiography: image quality, diagnostic accuracy, and potential for radiation dose reduction using a novel iterative image reconstruction technique - comparison with traditional filtered back projection. Eur Radiol 2011; 21:2130-2138
    • (2011) Eur Radiol , vol.21 , pp. 2130-2138
    • Moscariello, A.1    Takx, R.A.2    Schoepf, U.J.3
  • 17
    • 84856605802 scopus 로고    scopus 로고
    • CT image quality improvement using adaptive iterative dose reduction with wide-volume acquisition on 320-detector CT
    • Gervaise A, Osemont B, Lecocq S, et al. CT image quality improvement using adaptive iterative dose reduction with wide-volume acquisition on 320-detector CT. Eur Radiol 2012; 22:295-301
    • (2012) Eur Radiol , vol.22 , pp. 295-301
    • Gervaise, A.1    Osemont, B.2    Lecocq, S.3
  • 18
    • 78149440208 scopus 로고    scopus 로고
    • Model-based measurements of the diameter of the internal carotid artery in CT angiography images
    • Gratama van Andel HA, Venema HW, Bol K, et al. Model-based measurements of the diameter of the internal carotid artery in CT angiography images. Med Phys 2010; 37:5711-5727
    • (2010) Med Phys , vol.37 , pp. 5711-5727
    • Gratama Van Andel, H.A.1    Venema, H.W.2    Bol, K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.