메뉴 건너뛰기




Volumn 15, Issue 1, 2014, Pages

A modular computational framework for automated peak extraction from ion mobility spectra

Author keywords

Automated pipeline; Ion mobility spectrometry; Peak detection; Signal processing

Indexed keywords

BIOLOGICAL MARKER; ION; VOLATILE ORGANIC COMPOUND;

EID: 84892660041     PISSN: None     EISSN: 14712105     Source Type: Journal    
DOI: 10.1186/1471-2105-15-25     Document Type: Article
Times cited : (21)

References (23)
  • 1
    • 82355171451 scopus 로고    scopus 로고
    • MCC/IMS as potential noninvasive technique in the diagnosis of patients with COPD with and without alpha 1-antitrypsin deficiency
    • Koczulla R, Hattesohl A, Schmid S, Bödeker B, Maddula S, Baumbach JI. MCC/IMS as potential noninvasive technique in the diagnosis of patients with COPD with and without alpha 1-antitrypsin deficiency. Int J Ion Mobility Spectrom 2011, 14(4):177-185.
    • (2011) Int J Ion Mobility Spectrom , vol.14 , Issue.4 , pp. 177-185
    • Koczulla, R.1    Hattesohl, A.2    Schmid, S.3    Bödeker, B.4    Maddula, S.5    Baumbach, J.I.6
  • 2
    • 80052207979 scopus 로고    scopus 로고
    • A review of recent, unconventional applications of ion mobility spectrometry (IMS)
    • 10.1016/j.aca.2011.07.021, 21889625
    • Armenta S, Alcala M, Blanco M. A review of recent, unconventional applications of ion mobility spectrometry (IMS). Analytica Chimica Acta 2011, 703(2):114-123. 10.1016/j.aca.2011.07.021, 21889625.
    • (2011) Analytica Chimica Acta , vol.703 , Issue.2 , pp. 114-123
    • Armenta, S.1    Alcala, M.2    Blanco, M.3
  • 3
    • 69749091957 scopus 로고    scopus 로고
    • Ion mobility spectrometry for the detection of volatile organic compounds in exhaled breath of patients with lung cancer: results of a pilot study
    • 10.1136/thx.2008.099465, 19158121
    • Westhoff M, Litterst P, Freitag L, Urfer W, Bader S, Baumbach JI. Ion mobility spectrometry for the detection of volatile organic compounds in exhaled breath of patients with lung cancer: results of a pilot study. Thorax 2009, 64(9):744-748. 10.1136/thx.2008.099465, 19158121.
    • (2009) Thorax , vol.64 , Issue.9 , pp. 744-748
    • Westhoff, M.1    Litterst, P.2    Freitag, L.3    Urfer, W.4    Bader, S.5    Baumbach, J.I.6
  • 4
    • 67650062792 scopus 로고    scopus 로고
    • Peak comparison in MCC/IMS-data - searching for potential biomarkers in human breath data
    • Bödeker B, Vautz W, Baumbach JI. Peak comparison in MCC/IMS-data - searching for potential biomarkers in human breath data. Int J Ion Mobility Spectrom 2008, 11(1-4):89-93.
    • (2008) Int J Ion Mobility Spectrom , vol.11 , Issue.1-4 , pp. 89-93
    • Bödeker, B.1    Vautz, W.2    Baumbach, J.I.3
  • 5
    • 72349084045 scopus 로고    scopus 로고
    • MCC/IMS signals in human breath related to sarcoidosis - results of a feasibility study using an automated peak finding procedure
    • 10.1088/1752-7155/3/4/046001, 21386194
    • Bunkowski A, Bödeker B, Bader S, Westhoff M, Litterst P, Baumbach JI. MCC/IMS signals in human breath related to sarcoidosis - results of a feasibility study using an automated peak finding procedure. J Breath Res 2009, 3(4):046001. 10.1088/1752-7155/3/4/046001, 21386194.
    • (2009) J Breath Res , vol.3 , Issue.4 , pp. 046001
    • Bunkowski, A.1    Bödeker, B.2    Bader, S.3    Westhoff, M.4    Litterst, P.5    Baumbach, J.I.6
  • 6
    • 78649905094 scopus 로고    scopus 로고
    • Differentiation of chronic obstructive pulmonary disease (COPD) including lung cancer from healthy control group by breath analysis using ion mobility spectrometry
    • Westhoff M, Litterst P, Maddula S, Bödeker B, Rahmann S, Davies AN, Baumbach JI. Differentiation of chronic obstructive pulmonary disease (COPD) including lung cancer from healthy control group by breath analysis using ion mobility spectrometry. Int J Ion Mobility Spectrom 2010, 13(3-4):131-139.
    • (2010) Int J Ion Mobility Spectrom , vol.13 , Issue.3-4 , pp. 131-139
    • Westhoff, M.1    Litterst, P.2    Maddula, S.3    Bödeker, B.4    Rahmann, S.5    Davies, A.N.6    Baumbach, J.I.7
  • 7
    • 60549086913 scopus 로고    scopus 로고
    • Determination of volatile organic compounds in exhaled breath by ion mobility spectrometry
    • Ulanowska A, Ligor M, Amann A, Buszewski B. Determination of volatile organic compounds in exhaled breath by ion mobility spectrometry. Chemia Analityczna 2008, 53(6):953-965.
    • (2008) Chemia Analityczna , vol.53 , Issue.6 , pp. 953-965
    • Ulanowska, A.1    Ligor, M.2    Amann, A.3    Buszewski, B.4
  • 9
    • 85016505941 scopus 로고    scopus 로고
    • Peak detection method evaluation for ion mobility spectrometry by using machine learning approaches
    • Hauschild AC, Kopczynski D, D'Addario M, Baumbach JI, Rahmann S, Baumbach J. Peak detection method evaluation for ion mobility spectrometry by using machine learning approaches. Metabolites 2013, 3(2):277-293.
    • (2013) Metabolites , vol.3 , Issue.2 , pp. 277-293
    • Hauschild, A.C.1    Kopczynski, D.2    D'Addario, M.3    Baumbach, J.I.4    Rahmann, S.5    Baumbach, J.6
  • 13
    • 67650016200 scopus 로고    scopus 로고
    • Preprocessing of ion mobility spectra by lognormal detailing and wavelet transform
    • Bader S, Urfer W, Baumbach JI. Preprocessing of ion mobility spectra by lognormal detailing and wavelet transform. Int J Ion Mobility Spectrom 2008, 11(1-4):43-49.
    • (2008) Int J Ion Mobility Spectrom , vol.11 , Issue.1-4 , pp. 43-49
    • Bader, S.1    Urfer, W.2    Baumbach, J.I.3
  • 14
    • 0042553279 scopus 로고
    • Smoothing and differentiation of data by simplified least squares procedures
    • Savitzky A, Golay MJE. Smoothing and differentiation of data by simplified least squares procedures. Anal Chem 1964, 36(8):1627-1639.
    • (1964) Anal Chem , vol.36 , Issue.8 , pp. 1627-1639
    • Savitzky, A.1    Golay, M.J.E.2
  • 15
    • 79952160992 scopus 로고    scopus 로고
    • Automated peak detection and matching algorithm for gas chromatography-differential mobility spectrometry
    • 10.1021/ac102110y, 3694766, 21204557
    • Fong SS, Rearden P, Kanchagar C, Sassetti C, Trevejo J, Brereton RG. Automated peak detection and matching algorithm for gas chromatography-differential mobility spectrometry. Anal Chem 2011, 83(5):1537-1546. 10.1021/ac102110y, 3694766, 21204557.
    • (2011) Anal Chem , vol.83 , Issue.5 , pp. 1537-1546
    • Fong, S.S.1    Rearden, P.2    Kanchagar, C.3    Sassetti, C.4    Trevejo, J.5    Brereton, R.G.6
  • 18
    • 79953212248 scopus 로고    scopus 로고
    • Exact algorithms for cluster editing: evaluation and experiments
    • Böcker S, Briesemeister S, Klau GW. Exact algorithms for cluster editing: evaluation and experiments. Algorithmica 2011, 60(2):316-334.
    • (2011) Algorithmica , vol.60 , Issue.2 , pp. 316-334
    • Böcker, S.1    Briesemeister, S.2    Klau, G.W.3
  • 19
    • 67650048692 scopus 로고    scopus 로고
    • Recommendation of a standard format for data sets from GC/IMS with sensor-controlled sampling
    • Vautz W, Bödeker B, Bader S, Baumbach JI. Recommendation of a standard format for data sets from GC/IMS with sensor-controlled sampling. Int J Ion Mobility Spectrom 2008, 11(1-4):71-76.
    • (2008) Int J Ion Mobility Spectrom , vol.11 , Issue.1-4 , pp. 71-76
    • Vautz, W.1    Bödeker, B.2    Bader, S.3    Baumbach, J.I.4
  • 20
    • 84860697621 scopus 로고    scopus 로고
    • Recommendation for an upgrade to the standard format in order to cross-link the GC/MSD and the MCC/IMS data
    • Maddula S, Rupp K, Baumbach JI. Recommendation for an upgrade to the standard format in order to cross-link the GC/MSD and the MCC/IMS data. Int J Ion Mobility Spectrom 2012, 15(2):79-81.
    • (2012) Int J Ion Mobility Spectrom , vol.15 , Issue.2 , pp. 79-81
    • Maddula, S.1    Rupp, K.2    Baumbach, J.I.3
  • 21
    • 84945923591 scopus 로고
    • A method for comparing two hierarchical clusterings
    • Fowlkes EB, Mallows CL. A method for comparing two hierarchical clusterings. J Am Stat Assoc 1983, 78(383):553-569.
    • (1983) J Am Stat Assoc , vol.78 , Issue.383 , pp. 553-569
    • Fowlkes, E.B.1    Mallows, C.L.2
  • 22
    • 82355192294 scopus 로고    scopus 로고
    • MCC-IMS data analysis using automated spectra processing and explorative visualisation methods
    • Bunkowski A. MCC-IMS data analysis using automated spectra processing and explorative visualisation methods. PhD thesis, University Bielefeld, Bielefeld, Germany; 2011,
    • (2011) PhD thesis, University Bielefeld, Bielefeld, Germany;
    • Bunkowski, A.1
  • 23
    • 34247265534 scopus 로고    scopus 로고
    • Reduction of ion mobility spectrometry data by clustering characteristic peak structures
    • Bader S, Urfer W, Baumbach JI. Reduction of ion mobility spectrometry data by clustering characteristic peak structures. J Chemometrics 2007, 20(3-4):128-135.
    • (2007) J Chemometrics , vol.20 , Issue.3-4 , pp. 128-135
    • Bader, S.1    Urfer, W.2    Baumbach, J.I.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.