메뉴 건너뛰기




Volumn 14, Issue 4, 2011, Pages 167-175

Characterization of propofol in human breath of patients undergoing anesthesia

Author keywords

Breath; Intensive care; Medical application; Propofol; Propofol CAS 2078 54 8 ; VOC; Volatile organic compounds

Indexed keywords

BREATH; DETECTION LIMITS; HUMAN BREATH; INTENSIVE CARE; ION MOBILITY SPECTROMETRY; KINETIC MODELS; MULTI-CAPILLARY COLUMNS; PROPOFOL;

EID: 82455187902     PISSN: 14356163     EISSN: 18654584     Source Type: Journal    
DOI: 10.1007/s12127-011-0080-y     Document Type: Article
Times cited : (38)

References (30)
  • 2
    • 41149098586 scopus 로고    scopus 로고
    • Analysis of bio-processes using ion mobility spectrometry
    • Vautz W, Baumbach JI (2008) Analysis of bio-processes using ion mobility spectrometry. Eng Life Sci 8(1): 19-25.
    • (2008) Eng Life Sci , vol.8 , Issue.1 , pp. 19-25
    • Vautz, W.1    Baumbach, J.I.2
  • 4
    • 82355177382 scopus 로고    scopus 로고
    • Breath discovery based on ion mobility spectrometry and classification and differentiation models for lung diseases
    • Baumbach JI, et al. (2010) Breath discovery based on ion mobility spectrometry and classification and differentiation models for lung diseases. Biomedizinische Technik 55(Suppl. 1).
    • (2010) Biomedizinische Technik , vol.55 , Issue.SUPPL. 1
    • Baumbach, J.I.1
  • 5
    • 0037049287 scopus 로고    scopus 로고
    • Novel application for ion mobility spectrometry: diagnosing vaginal infections through measurement of biogenic amines
    • Karpas Z et al (2002) Novel application for ion mobility spectrometry: diagnosing vaginal infections through measurement of biogenic amines. Anal Chim Acta 474(1-2): 115-123.
    • (2002) Anal Chim Acta , vol.474 , Issue.1-2 , pp. 115-123
    • Karpas, Z.1
  • 6
    • 67650030893 scopus 로고    scopus 로고
    • Exemplar application of multi-capillary column ion mobility spectrometry for biological medical purpose
    • Vautz W, Baumbach JI (2008) Exemplar application of multi-capillary column ion mobility spectrometry for biological medical purpose. Int J Ion Mobility Spectrom 11(1): 35-42.
    • (2008) Int J Ion Mobility Spectrom , vol.11 , Issue.1 , pp. 35-42
    • Vautz, W.1    Baumbach, J.I.2
  • 7
    • 13244262861 scopus 로고    scopus 로고
    • Metabolite profiling of fungi and yeast: from phenotype to metabolome by MS and informatics
    • Smedsgaard J, Nielsen J (2005) Metabolite profiling of fungi and yeast: from phenotype to metabolome by MS and informatics. J Exp Bot 56(410): 273-286.
    • (2005) J Exp Bot , vol.56 , Issue.410 , pp. 273-286
    • Smedsgaard, J.1    Nielsen, J.2
  • 8
    • 82455188450 scopus 로고    scopus 로고
    • In: Dept. of Biochemical and Chemical Engineering. University Dortmund, Dortmund
    • Maddula S (2005) Volatile metabolite fingerprints of Escherichia coli. In: Dept. of Biochemical and Chemical Engineering. University Dortmund, Dortmund. p. 52.
    • (2005) Volatile metabolite fingerprints of Escherichia coli , pp. 52
    • Maddula, S.1
  • 9
    • 33847370301 scopus 로고    scopus 로고
    • Tumour metabolomics in animal models of human cancer
    • Griffin JL, Kauppinen RA (2007) Tumour metabolomics in animal models of human cancer. J Proteome Res 6(2): 498-505.
    • (2007) J Proteome Res , vol.6 , Issue.2 , pp. 498-505
    • Griffin, J.L.1    Kauppinen, R.A.2
  • 10
    • 77949866490 scopus 로고    scopus 로고
    • Automated needle trap heart-Cut GC/MS and needle trap comprehensive two-dimensional GC/TOF-MS for breath gas analysis in the clinical environment
    • Mieth M et al (2010) Automated needle trap heart-Cut GC/MS and needle trap comprehensive two-dimensional GC/TOF-MS for breath gas analysis in the clinical environment. Anal Chem 82(6): 2541-2551.
    • (2010) Anal Chem , vol.82 , Issue.6 , pp. 2541-2551
    • Mieth, M.1
  • 11
    • 67649666959 scopus 로고    scopus 로고
    • Analysis of exhaled breath from smokers, passive smokers and non-smokers by solid-phase microextraction gas chromatography/mass spectrometry
    • Buszewski B et al (2009) Analysis of exhaled breath from smokers, passive smokers and non-smokers by solid-phase microextraction gas chromatography/mass spectrometry. Biomed Chromatogr 23(5): 551-556.
    • (2009) Biomed Chromatogr , vol.23 , Issue.5 , pp. 551-556
    • Buszewski, B.1
  • 12
    • 77952934972 scopus 로고    scopus 로고
    • Real-time breath gas analysis for pharmacokinetics: monitoring exhaled breath by on-line proton-transfer-reaction mass spectrometry after ingestion of eucalyptol-containing capsules
    • Copyright (C) 2010 American Chemical Society (ACS). All Rights Reserved.): p. No pp. given
    • Beauchamp J, Kirsch F, Buettner A (2010) Real-time breath gas analysis for pharmacokinetics: monitoring exhaled breath by on-line proton-transfer-reaction mass spectrometry after ingestion of eucalyptol-containing capsules. J Breath Res 4(Copyright (C) 2010 American Chemical Society (ACS). All Rights Reserved.): p. No pp. given.
    • (2010) J Breath Res , vol.4
    • Beauchamp, J.1    Kirsch, F.2    Buettner, A.3
  • 13
    • 68149126539 scopus 로고    scopus 로고
    • On-line breath analysis with PTR-TOF
    • Herbig J et al (2009) On-line breath analysis with PTR-TOF. J Breath Res 3(2): 027004/1-027004/10.
    • (2009) J Breath Res , vol.3 , Issue.2 , pp. 1-10
    • Herbig, J.1
  • 14
    • 76249132107 scopus 로고    scopus 로고
    • Isoprene levels in the exhaled breath of 200 healthy pupils within the age range 7-18 years studied using SIFT-MS
    • Smith D et al (2010) Isoprene levels in the exhaled breath of 200 healthy pupils within the age range 7-18 years studied using SIFT-MS. J Breath Res 4(1): 017101/1-017101/7.
    • (2010) J Breath Res , vol.4 , Issue.1 , pp. 1-7
    • Smith, D.1
  • 15
    • 68149183618 scopus 로고    scopus 로고
    • In vitro SIFT-MS validation of a breath fractionating device using a model VOC and ventilation system
    • doi:10.1088/1752-7155/3/1/016001
    • Seeley MJ et al (2009) In vitro SIFT-MS validation of a breath fractionating device using a model VOC and ventilation system. J Breath Res 3(016001): 7. doi: 10. 1088/1752-7155/3/1/016001.
    • (2009) J Breath Res , vol.3 , pp. 7
    • Seeley, M.J.1
  • 16
    • 69249106891 scopus 로고    scopus 로고
    • Exhaled biomarkers in lung cancer
    • Horvath I et al (2009) Exhaled biomarkers in lung cancer. Eur Respir J 34(1): 261-275.
    • (2009) Eur Respir J , vol.34 , Issue.1 , pp. 261-275
    • Horvath, I.1
  • 17
    • 63249102023 scopus 로고    scopus 로고
    • An electronic nose in the discrimination of patients with non-small cell lung cancer and COPD
    • Dragonieri S et al (2009) An electronic nose in the discrimination of patients with non-small cell lung cancer and COPD. Lung Cancer 64(2): 166-170.
    • (2009) Lung Cancer , vol.64 , Issue.2 , pp. 166-170
    • Dragonieri, S.1
  • 18
    • 82455191488 scopus 로고    scopus 로고
    • History, technical and regulatory aspects of exhaled nitric oxide
    • Silkoff P (2008) History, technical and regulatory aspects of exhaled nitric oxide. J Breath Res 2(3): 037001/1-037001/8.
    • (2008) J Breath Res , vol.2 , Issue.3 , pp. 1-8
    • Silkoff, P.1
  • 19
    • 84874880856 scopus 로고    scopus 로고
    • An analysis of volatiles in the headspace of the faeces of neonates
    • De Lacy Costello B et al (2008) An analysis of volatiles in the headspace of the faeces of neonates. J Breath Res 2(3): 037023/1-037023/8.
    • (2008) J Breath Res , vol.2 , Issue.3 , pp. 1-8
    • de Lacy Costello, B.1
  • 20
    • 67650042552 scopus 로고    scopus 로고
    • Early lung cancer diagnostics by ion mobility spectrometry data handling
    • Davies AN, Baumbach JI (2008) Early lung cancer diagnostics by ion mobility spectrometry data handling. Spectrosc Eur 20(5): 18-21.
    • (2008) Spectrosc Eur , vol.20 , Issue.5 , pp. 18-21
    • Davies, A.N.1    Baumbach, J.I.2
  • 22
    • 78649905094 scopus 로고    scopus 로고
    • Differentiation of chronic obstructive pulmonary disease (COPD) including lung cancer from healthy control group by breath analysis using ion mobility spectrometry
    • Westhoff M et al (2010) Differentiation of chronic obstructive pulmonary disease (COPD) including lung cancer from healthy control group by breath analysis using ion mobility spectrometry. Int J Ion Mobility Spectrom 13(3-4): 131-139.
    • (2010) Int J Ion Mobility Spectrom , vol.13 , Issue.3-4 , pp. 131-139
    • Westhoff, M.1
  • 23
    • 33846356443 scopus 로고    scopus 로고
    • Ion mobility spectrometry to detect lung cancer and airway infections
    • Baumbach JI, Westhoff M (2006) Ion mobility spectrometry to detect lung cancer and airway infections. Spectrosc Eur 18(6): 22-27.
    • (2006) Spectrosc Eur , vol.18 , Issue.6 , pp. 22-27
    • Baumbach, J.I.1    Westhoff, M.2
  • 24
    • 82355162339 scopus 로고    scopus 로고
    • Metabolites in human breath during indursulfase therapy of a patient with hunter disease-first results of time series using MCC/IMS
    • Baumbach JI, et al. (2010) Metabolites in human breath during indursulfase therapy of a patient with hunter disease-first results of time series using MCC/IMS. Biomedizinische Technik 55(Suppl. 1).
    • (2010) Biomedizinische Technik , vol.55 , Issue.SUPPL. 1
    • Baumbach, J.I.1
  • 25
    • 71749099575 scopus 로고    scopus 로고
    • Determination of serum propofol concentrations by breath analysis using ion mobility spectrometry
    • Perl T et al (2009) Determination of serum propofol concentrations by breath analysis using ion mobility spectrometry. Br J Anaesth 103(6): 822-827.
    • (2009) Br J Anaesth , vol.103 , Issue.6 , pp. 822-827
    • Perl, T.1
  • 26
    • 82455191489 scopus 로고    scopus 로고
    • Propofol in der Atemluft-MCC-Ionen mobilitäts spektrometrie propofol in expired air using MCC-ion mobility spectrometry
    • Perl T, et al. (2010) Propofol in der Atemluft-MCC-Ionen mobilitäts spektrometrie propofol in expired air using MCC-ion mobility spectrometry. Biomedizinische Technik 55(Suppl. 1).
    • (2010) Biomedizinische Technik , vol.55 , Issue.SUPPL. 1
    • Perl, T.1
  • 27
    • 0033771211 scopus 로고    scopus 로고
    • The role of human lungs in the biotransformation of propofol
    • Dawidowicz AL et al (2000) The role of human lungs in the biotransformation of propofol. Anesthesiology 93(4): 992-997.
    • (2000) Anesthesiology , vol.93 , Issue.4 , pp. 992-997
    • Dawidowicz, A.L.1
  • 30
    • 80052207979 scopus 로고    scopus 로고
    • A review of recent, unconventional applications of ion mobility spectrometry (IMS)
    • Armenta S, Alcala M, Blanco M (2011) A review of recent, unconventional applications of ion mobility spectrometry (IMS). Anal Chim Acta 703: 114-123.
    • (2011) Anal Chim Acta , vol.703 , pp. 114-123
    • Armenta, S.1    Alcala, M.2    Blanco, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.