메뉴 건너뛰기




Volumn 4, Issue FEB, 2010, Pages

Design challenges of implantable pressure monitoring system

Author keywords

Closed loop neuro prosthetics devices; Design challenges; Implantable pressure sensor; Long term

Indexed keywords


EID: 84892514651     PISSN: 16624548     EISSN: 1662453X     Source Type: Journal    
DOI: 10.3389/neuro.20.002.2010     Document Type: Article
Times cited : (46)

References (26)
  • 1
    • 0035892868 scopus 로고    scopus 로고
    • A wireless batch sealed absolute capacitive pressure sensor
    • Akar, O., Akin, T., and Najafi, K. (2001). A wireless batch sealed absolute capacitive pressure sensor. Sens. Actuators A. Phys. 95, 29-38.
    • (2001) Sens. Actuators A. Phys. , vol.95 , pp. 29-38
    • Akar, O.1    Akin, T.2    Najafi, K.3
  • 3
    • 0041863311 scopus 로고    scopus 로고
    • Biomonitoring with wireless communications
    • Budinger, T. F. (2003). Biomonitoring with wireless communications. Annu. Rev. Biomed. Eng. 5, 383-412.
    • (2003) Annu. Rev. Biomed. Eng. , vol.5 , pp. 383-412
    • Budinger, T.F.1
  • 5
    • 33847350159 scopus 로고    scopus 로고
    • An implantable capacitive pressure sensor for biomedical applications
    • Chiang, C. C., CLin, C. K., and Ju, M. S. (2007). An implantable capacitive pressure sensor for biomedical applications. Sens. Actuators A. Phys. 134, 382-388.
    • (2007) Sens. Actuators A. Phys. , vol.134 , pp. 382-388
    • Chiang, C.C.1    Clin, C.K.2    Ju, M.S.3
  • 6
    • 0017350479 scopus 로고
    • Radio telemetry of intraocular pressure in vitro
    • Cooper, R., and Beale, D. (1977). Radio telemetry of intraocular pressure in vitro. Invest. Ophthalmol. Vis. Sci. 16, 168-171.
    • (1977) Invest. Ophthalmol. Vis. Sci. , vol.16 , pp. 168-171
    • Cooper, R.1    Beale, D.2
  • 7
    • 24944435756 scopus 로고    scopus 로고
    • An autonomous bladder pressure monitoring system
    • Coosemans, J., and Puers, R. (2005). An autonomous bladder pressure monitoring system. Sens. Actuators A Phys. 123-124, 155-161.
    • (2005) Sens. Actuators A Phys. , vol.123-124 , pp. 155-161
    • Coosemans, J.1    Puers, R.2
  • 8
    • 42149094185 scopus 로고    scopus 로고
    • Remotely-Powered Wireless Monitoring Systems
    • Ph. D. Dissertation, University of Michigan, Ann Arbor
    • DeHennis, A. D. (2004). Remotely-Powered Wireless Monitoring Systems. Ph. D. Dissertation, University of Michigan, Ann Arbor.
    • (2004)
    • DeHennis, A.D.1
  • 9
    • 0030718299 scopus 로고    scopus 로고
    • Accelerated testing of anodically bonded glass-silicon packages in salt water
    • Proceedings of 9th International Conference on Solid State Sensors and Actuators, Transducers, Chicago
    • Dokmeci, M. R., Von Arx, J. A., and Najafi, K. (1997). Accelerated testing of anodically bonded glass-silicon packages in salt water. In Proceedings of 9th International Conference on Solid State Sensors and Actuators, Transducers '97, Chicago, pp. 283-286.
    • (1997) , vol.97 , pp. 283-286
    • Dokmeci, M.R.1    Von Arx, J.A.2    Najafi, K.3
  • 10
    • 0033985639 scopus 로고    scopus 로고
    • A portable microsystem-based telemetric pressure and temperature measurement unit
    • Flick, B. B., and Orglmeister, R. (2000). A portable microsystem-based telemetric pressure and temperature measurement unit. IEEE Trans. Biomed. Eng. 47, 12-16.
    • (2000) IEEE Trans. Biomed. Eng. , vol.47 , pp. 12-16
    • Flick, B.B.1    Orglmeister, R.2
  • 11
    • 84903863276 scopus 로고    scopus 로고
    • Telemetric implantable pressure sensor for short-term and long-term monitoring of intracranial pressure
    • Proceedings of the 29th Annual International Conference of the IEEE EMBS, Lyon, France, August
    • Frischholz, M., Sarmento, L., Wenzel, M., Aquilina, K., Edwards, R., and Coakham, H. B. (2007). Telemetric implantable pressure sensor for short-term and long-term monitoring of intracranial pressure, 514. In Proceedings of the 29th Annual International Conference of the IEEE EMBS, Lyon, France, August 23-26.
    • (2007) , vol.514 , pp. 23-26
    • Frischholz, M.1    Sarmento, L.2    Wenzel, M.3    Aquilina, K.4    Edwards, R.5    Coakham, H.B.6
  • 13
    • 0030181536 scopus 로고    scopus 로고
    • Curvature changing or flateening of anodically bnded silicon and borosilicate glass
    • Harz, M., and Engelke, H. (1996). Curvature changing or flateening of anodically bnded silicon and borosilicate glass. Sens. Actuators A. Phys. 55, 201-209.
    • (1996) Sens. Actuators A. Phys. , vol.55 , pp. 201-209
    • Harz, M.1    Engelke, H.2
  • 14
    • 78650822901 scopus 로고    scopus 로고
    • Technology Advances and Challenges in Hermetic Packaging for Implantable Medical Devices
    • Implantable Neural Prostheses 2-Techniques and Engineering Approaches, Biological and Medical Physics, Biomedical Engineering. D. D. Zhou and E. Greenbaum, eds. (New York, Springer)
    • Jiang, G., and Zhou, D. (2009). Technology Advances and Challenges in Hermetic Packaging for Implantable Medical Devices. In Implantable Neural Prostheses 2-Techniques and Engineering Approaches, Biological and Medical Physics, Biomedical Engineering. D. D. Zhou and E. Greenbaum, eds. (New York, Springer). pp. 27-61.
    • (2009) , pp. 27-61
    • Jiang, G.1    Zhou, D.2
  • 15
    • 0019874173 scopus 로고
    • Blood compatibility of components and materials in silicon integrated circuits
    • Kanda, Y., and Aoshima, R., Takada, A. (1981). Blood compatibility of components and materials in silicon integrated circuits. Electron Lett. 17, 558-559.
    • (1981) Electron Lett , vol.17 , pp. 558-559
    • Kanda, Y.1    Aoshima, R.2    Takada, A.3
  • 17
    • 0014095379 scopus 로고
    • Intracranial pressure measurement with a miniature passive implanted pressure transensor
    • Olsen, E. R., Collins, C. C., Loughborough, W. F., Richards, V., Adams, J. E., and Pinto, D. W. (1967). Intracranial pressure measurement with a miniature passive implanted pressure transensor. Am. J. Surg. 113, 727-729.
    • (1967) Am. J. Surg. , vol.113 , pp. 727-729
    • Olsen, E.R.1    Collins, C.C.2    Loughborough, W.F.3    Richards, V.4    Adams, J.E.5    Pinto, D.W.6
  • 18
    • 0027611922 scopus 로고
    • Capacitive sensors: when and how to use them
    • Puers, R. (1993). Capacitive sensors: when and how to use them. Sens. Actuators A. Phys. 37/38, 93-105.
    • (1993) Sens. Actuators A. Phys. , vol.37 , Issue.38 , pp. 93-105
    • Puers, R.1
  • 19
    • 0029234140 scopus 로고
    • Selection of glass, anodic bonding conditions and material compatibility for silicon-glass capacitive sensors
    • 46-47
    • Rogers, T., and Kowal, J. (1995). Selection of glass, anodic bonding conditions and material compatibility for silicon-glass capacitive sensors. Sens. Actuators A. Phys. 46-47, 113-120.
    • (1995) Sens. Actuators A. Phys. , pp. 113-120
    • Rogers, T.1    Kowal, J.2
  • 20
    • 0023573368 scopus 로고
    • A closed loop system to control the bladder function
    • Proceedings of the Ninth Annual Conference of the IEEE Engineering in Medicine and Biology Society, Boston, November 13-16
    • Sansen, W., Vereecken, R., Puers, R., Folens, G., and Van Nuland, T. (1987). A closed loop system to control the bladder function. In Proceedings of the Ninth Annual Conference of the IEEE Engineering in Medicine and Biology Society, Boston, November 13-16, pp. 1149-1150.
    • (1987) , pp. 1149-1150
    • Sansen, W.1    Vereecken, R.2    Puers, R.3    Folens, G.4    Van Nuland, T.5
  • 22
    • 0000262569 scopus 로고
    • Blood pressure responses of wild giraffes studied by radio telemetry
    • Van Citters, R. L., Kemper, W. S., and Franklin, D. L. (1966). Blood pressure responses of wild giraffes studied by radio telemetry. Science 152, 384-386.
    • (1966) Science , vol.152 , pp. 384-386
    • Van Citters, R.L.1    Kemper, W.S.2    Franklin, D.L.3
  • 23
    • 0003439323 scopus 로고    scopus 로고
    • Microstereolithography other fabrication techniques for 3D MEMS
    • Chichester, John Wiley & Sons Ltd
    • Varadan, V. K., Jiang, X., and Varadan, V. (2001). Microstereolithography other fabrication techniques for 3D MEMS. Chichester, John Wiley & Sons Ltd.p. 260.
    • (2001) , pp. 260
    • Varadan, V.K.1    Jiang, X.2    Varadan, V.3
  • 24
    • 42149095698 scopus 로고    scopus 로고
    • A Wireless Microsystem for Multichannel Neural Recording Microprobes
    • Ph. D. Dissertation, University of Michigan, Ann Arbor
    • Yu, H. (2004). A Wireless Microsystem for Multichannel Neural Recording Microprobes. Ph. D. Dissertation, University of Michigan, Ann Arbor.
    • (2004)
    • Yu, H.1
  • 25
    • 0002791341 scopus 로고
    • Biocompatibility of electrodes and materials in the central nervous system
    • Neural Prostheses: Fundamental Studies, W. Agnew, and D. McCreery, eds (Englewood Cliffs, NJ, Prentice Hall)
    • Yuen, T., Agnew, W., Bullara, L., and McCreery, D. B. (1990). Biocompatibility of electrodes and materials in the central nervous system. In Neural Prostheses: Fundamental Studies, W. Agnew, and D. McCreery, eds (Englewood Cliffs, NJ, Prentice Hall), pp 171-321.
    • (1990) , pp. 171-321
    • Yuen, T.1    Agnew, W.2    Bullara, L.3    McCreery, D.B.4
  • 26
    • 84892533776 scopus 로고    scopus 로고
    • Accelerated corrosion tests on Silicon wafers for implantable medical devices
    • Proceedings of 198th Electrochemical Society Meeting, Phoenix
    • Zhou, D., Mech, B., and Greenberg, R. (2000). Accelerated corrosion tests on Silicon wafers for implantable medical devices. Proceedings of 198th Electrochemical Society Meeting, Phoenix, p. 363.
    • (2000) , pp. 363
    • Zhou, D.1    Mech, B.2    Greenberg, R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.