메뉴 건너뛰기




Volumn 41, Issue 1, 2014, Pages

Adaptive nonlocal means filtering based on local noise level for CT denoising

Author keywords

adaptive denoising; CT dose reduction; image denoising; noise estimation; nonlocal means filtering

Indexed keywords

ADAPTIVE FILTERING; ADAPTIVE FILTERS; COMPUTATIONAL EFFICIENCY; COMPUTERIZED TOMOGRAPHY; GRAPHICS PROCESSING UNIT; HOSPITAL DATA PROCESSING; IMAGE RESOLUTION; MODULATION; NOISE ABATEMENT; NOISE POLLUTION; PHANTOMS; POWER SPECTRUM; RADIATION; RADIOLOGY;

EID: 84892166859     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.4851635     Document Type: Article
Times cited : (271)

References (45)
  • 1
    • 36549007486 scopus 로고    scopus 로고
    • Computed tomography: An increasing source of radiation exposure
    • 10.1056/NEJMra072149
    • D. J. Brenner and E. J. Hall, Computed tomography: An increasing source of radiation exposure., New Engl. J. Med. 357, 2277-2284 (2007). 10.1056/NEJMra072149
    • (2007) New Engl. J. Med. , vol.357 , pp. 2277-2284
    • Brenner, D.J.1    Hall, E.J.2
  • 2
    • 0031794571 scopus 로고    scopus 로고
    • Adaptive streak artifact reduction in computed tomography resulting from excessive x-ray photon noise
    • 10.1118/1.598410
    • J. Hsieh, Adaptive streak artifact reduction in computed tomography resulting from excessive x-ray photon noise., Med. Phys. 25, 2139-2147 (1998). 10.1118/1.598410
    • (1998) Med. Phys. , vol.25 , pp. 2139-2147
    • Hsieh, J.1
  • 3
    • 0035052748 scopus 로고    scopus 로고
    • Generalized multi-dimensional adaptive filtering for conventional and spiral single-slice, multi-slice, and cone-beam CT
    • 10.1118/1.1358303
    • M. Kachelriess, O. Watzke, and W. A. Kalender, Generalized multi-dimensional adaptive filtering for conventional and spiral single-slice, multi-slice, and cone-beam CT., Med. Phys. 28, 475-490 (2001). 10.1118/1.1358303
    • (2001) Med. Phys. , vol.28 , pp. 475-490
    • Kachelriess, M.1    Watzke, O.2    Kalender, W.A.3
  • 4
    • 8344272167 scopus 로고    scopus 로고
    • Nonlinear sinogram smoothing for low-dose X-ray CT
    • 10.1109/TNS.2004.834824
    • T. Li, X. Li, J. Wang, J. Wen, H. Lu, J. Hsieh, and Z. Liang, Nonlinear sinogram smoothing for low-dose X-ray CT., IEEE Trans. Nucl. Sci. 51, 2505-2513 (2004). 10.1109/TNS.2004.834824
    • (2004) IEEE Trans. Nucl. Sci. , vol.51 , pp. 2505-2513
    • Li, T.1    Li, X.2    Wang, J.3    Wen, J.4    Lu, H.5    Hsieh, J.6    Liang, Z.7
  • 5
    • 33947260155 scopus 로고    scopus 로고
    • Penalized weighted least-squares approach to sinogram noise reduction and image reconstruction for low-dose X-ray computed tomography
    • 10.1109/TMI.2006.882141
    • J. Wang, T. Li, H. Lu, and Z. Liang, Penalized weighted least-squares approach to sinogram noise reduction and image reconstruction for low-dose X-ray computed tomography., IEEE Trans. Med. Imaging 25, 1272-1283 (2006). 10.1109/TMI.2006.882141
    • (2006) IEEE Trans. Med. Imaging , vol.25 , pp. 1272-1283
    • Wang, J.1    Li, T.2    Lu, H.3    Liang, Z.4
  • 6
    • 21144458117 scopus 로고    scopus 로고
    • Penalized-likelihood sinogram smoothing for low-dose CT
    • 10.1118/1.1915015
    • P. J. La Rivière, Penalized-likelihood sinogram smoothing for low-dose CT., Med. Phys. 32, 1676-1683 (2005). 10.1118/1.1915015
    • (2005) Med. Phys. , vol.32 , pp. 1676-1683
    • La Rivière, P.J.1
  • 7
    • 33746927954 scopus 로고    scopus 로고
    • Penalized-likelihood sinogram restoration for computed tomography
    • 10.1109/TMI.2006.875429
    • P. J. La Rivière, J. Bian, and P. A. Vargas, Penalized-likelihood sinogram restoration for computed tomography., IEEE Trans. Med. Imaging 25, 1022-1036 (2006). 10.1109/TMI.2006.875429
    • (2006) IEEE Trans. Med. Imaging , vol.25 , pp. 1022-1036
    • La Rivière, P.J.1    Bian, J.2    Vargas, P.A.3
  • 8
    • 70350705569 scopus 로고    scopus 로고
    • Projection space denoising with bilateral filtering and CT noise modeling for dose reduction in CT
    • 10.1118/1.3232004
    • A. Manduca, L. Yu, J. D. Trzasko, N. Khaylova, J. M. Kofler, C. M. McCollough, and J. G. Fletcher, Projection space denoising with bilateral filtering and CT noise modeling for dose reduction in CT., Med. Phys. 36, 4911-4919 (2009). 10.1118/1.3232004
    • (2009) Med. Phys. , vol.36 , pp. 4911-4919
    • Manduca, A.1    Yu, L.2    Trzasko, J.D.3    Khaylova, N.4    Kofler, J.M.5    McCollough, C.M.6    Fletcher, J.G.7
  • 9
    • 0032319446 scopus 로고    scopus 로고
    • Bilateral filtering for gray and color images
    • 10.1109/ICCV.1998.710815
    • C. Tomasi and R. Manduchi, Bilateral filtering for gray and color images., Int. Conf. Comput. Vis. 6, 839-846 (1998). 10.1109/ICCV.1998.710815
    • (1998) Int. Conf. Comput. Vis. , vol.6 , pp. 839-846
    • Tomasi, C.1    Manduchi, R.2
  • 10
    • 44049111982 scopus 로고
    • Nonlinear total variation based noise removal algorithms
    • 10.1016/0167-2789(92)90242-F
    • L. I. Rudin, S. Osher, and E. Fatemi, Nonlinear total variation based noise removal algorithms., Physica D 60, 259-268 (1992). 10.1016/0167-2789(92) 90242-F
    • (1992) Physica D , vol.60 , pp. 259-268
    • Rudin, L.I.1    Osher, S.2    Fatemi, E.3
  • 11
    • 33645653318 scopus 로고    scopus 로고
    • A review of image denoising algorithms, with a new one
    • 10.1137/040616024
    • A. Buades, B. Coll, and J. M. Morel, A review of image denoising algorithms, with a new one., Multiscale Model. Simul. 4, 490-530 (2005). 10.1137/040616024
    • (2005) Multiscale Model. Simul. , vol.4 , pp. 490-530
    • Buades, A.1    Coll, B.2    Morel, J.M.3
  • 12
    • 33750383209 scopus 로고    scopus 로고
    • K-SVD: An algorithm for designing overcomplete dictionaries for sparse representation
    • 10.1109/TSP.2006.881199
    • M. Aharon, M. Elad, and A. Bruckstein, K-SVD: An algorithm for designing overcomplete dictionaries for sparse representation., IEEE Trans. Signal Process. 54, 4311-4322 (2006). 10.1109/TSP.2006.881199
    • (2006) IEEE Trans. Signal Process. , vol.54 , pp. 4311-4322
    • Aharon, M.1    Elad, M.2    Bruckstein, A.3
  • 13
    • 0029394375 scopus 로고
    • Globally convergent algorithms for maximum a posteriori transmission tomography
    • 10.1109/83.465107
    • K. Lange and J. A. Fessler, Globally convergent algorithms for maximum a posteriori transmission tomography., IEEE Trans. Image Process. 4, 1430-1438 (1995). 10.1109/83.465107
    • (1995) IEEE Trans. Image Process. , vol.4 , pp. 1430-1438
    • Lange, K.1    Fessler, J.A.2
  • 14
    • 0031972278 scopus 로고    scopus 로고
    • Iterative reconstruction for helical CT: A simulation study
    • 10.1088/0031-9155/43/4/003
    • J. Nuyts, B. De Man, P. Dupont, M. Defrise, P. Suetens, and L. Mortelmans, Iterative reconstruction for helical CT: A simulation study., Phys. Med. Biol. 43, 729-737 (1998). 10.1088/0031-9155/43/4/003
    • (1998) Phys. Med. Biol. , vol.43 , pp. 729-737
    • Nuyts, J.1    De Man, B.2    Dupont, P.3    Defrise, M.4    Suetens, P.5    Mortelmans, L.6
  • 15
    • 35649025312 scopus 로고    scopus 로고
    • A three-dimensional statistical approach to improved image quality for multislice helical CT
    • 10.1118/1.2789499
    • J.-B. Thibault, K. D. Sauer, C. A. Bouman, and J. Hsieh, A three-dimensional statistical approach to improved image quality for multislice helical CT., Med. Phys. 34, 4526-4544 (2007). 10.1118/1.2789499
    • (2007) Med. Phys. , vol.34 , pp. 4526-4544
    • Thibault, J.-B.1    Sauer, K.D.2    Bouman, C.A.3    Hsieh, J.4
  • 16
    • 0034919923 scopus 로고    scopus 로고
    • Ordered subset reconstruction for x-ray CT
    • 10.1088/0031-9155/46/7/307
    • F. J. Beekman and C. Kamphuis, Ordered subset reconstruction for x-ray CT., Phys. Med. Biol. 46, 1835-1844 (2001). 10.1088/0031-9155/46/7/307
    • (2001) Phys. Med. Biol. , vol.46 , pp. 1835-1844
    • Beekman, F.J.1    Kamphuis, C.2
  • 17
    • 0031106957 scopus 로고    scopus 로고
    • Grouped-coordinate ascent algorithms for penalized-likelihood transmission image reconstruction
    • 10.1109/42.563662
    • J. A. Fessler, E. P. Ficaro, N. H. Clinthorne, and K. Lange, Grouped-coordinate ascent algorithms for penalized-likelihood transmission image reconstruction., IEEE Trans. Med. Imaging 16, 166-175 (1997). 10.1109/42.563662
    • (1997) IEEE Trans. Med. Imaging , vol.16 , pp. 166-175
    • Fessler, J.A.1    Ficaro, E.P.2    Clinthorne, N.H.3    Lange, K.4
  • 18
    • 34147110778 scopus 로고    scopus 로고
    • Hyperfast parallel-beam and cone-beam backprojection using the cell general purpose hardware
    • 10.1118/1.2710328
    • M. Kachelriess, M. Knaup, and O. Bockenbach, Hyperfast parallel-beam and cone-beam backprojection using the cell general purpose hardware., Med. Phys. 34, 1474-1486 (2007). 10.1118/1.2710328
    • (2007) Med. Phys. , vol.34 , pp. 1474-1486
    • Kachelriess, M.1    Knaup, M.2    Bockenbach, O.3
  • 19
    • 33645301494 scopus 로고    scopus 로고
    • Evaluation of accelerated iterative x-ray CT image reconstruction using floating point graphics hardware
    • 10.1088/0031-9155/51/4/008
    • J. S. Kole and F. J. Beekman, Evaluation of accelerated iterative x-ray CT image reconstruction using floating point graphics hardware., Phys. Med. Biol. 51, 875-889 (2006). 10.1088/0031-9155/51/4/008
    • (2006) Phys. Med. Biol. , vol.51 , pp. 875-889
    • Kole, J.S.1    Beekman, F.J.2
  • 20
    • 23844499125 scopus 로고    scopus 로고
    • Accelerating popular tomographic reconstruction algorithms on commodity PC graphics hardware
    • 10.1109/TNS.2005.851398
    • F. Xu and K. Mueller, Accelerating popular tomographic reconstruction algorithms on commodity PC graphics hardware., IEEE Trans. Nucl. Sci. 52, 654-663 (2005). 10.1109/TNS.2005.851398
    • (2005) IEEE Trans. Nucl. Sci. , vol.52 , pp. 654-663
    • Xu, F.1    Mueller, K.2
  • 21
    • 34249649611 scopus 로고    scopus 로고
    • Real-time 3D computed tomographic reconstruction using commodity graphics hardware
    • 10.1088/0031-9155/52/12/006
    • F. Xu and K. Mueller, Real-time 3D computed tomographic reconstruction using commodity graphics hardware., Phys. Med. Biol. 52, 3405-3419 (2007). 10.1088/0031-9155/52/12/006
    • (2007) Phys. Med. Biol. , vol.52 , pp. 3405-3419
    • Xu, F.1    Mueller, K.2
  • 24
    • 42149154878 scopus 로고    scopus 로고
    • A robust and fast non-local means algorithm for image denoising
    • 10.1007/s11390-008-9129-8
    • Y. L. Liu, J. Wang, X. Chen, Y. W. Guo, and Q. S. Peng, A robust and fast non-local means algorithm for image denoising., J. Comput. Sci. Technol. 23 (2), 270-279 (2008). 10.1007/s11390-008-9129-8
    • (2008) J. Comput. Sci. Technol. , vol.23 , Issue.2 , pp. 270-279
    • Liu, Y.L.1    Wang, J.2    Chen, X.3    Guo, Y.W.4    Peng, Q.S.5
  • 25
    • 0037391657 scopus 로고    scopus 로고
    • Image reconstruction with shift-variant filtration and its implication for noise and resolution properties in fan-beam computed tomography
    • 10.1118/1.1556608
    • X. Pan and L. Yu, Image reconstruction with shift-variant filtration and its implication for noise and resolution properties in fan-beam computed tomography., Med. Phys. 30, 590-600 (2003). 10.1118/1.1556608
    • (2003) Med. Phys. , vol.30 , pp. 590-600
    • Pan, X.1    Yu, L.2
  • 26
    • 42649084336 scopus 로고    scopus 로고
    • Image covariance and lesion detectability in direct fan-beam x-ray computed tomography
    • 10.1088/0031-9155/53/10/002
    • A. Wunderlich and F. Noo, Image covariance and lesion detectability in direct fan-beam x-ray computed tomography., Phys. Med. Biol. 53, 2471-2493 (2008). 10.1088/0031-9155/53/10/002
    • (2008) Phys. Med. Biol. , vol.53 , pp. 2471-2493
    • Wunderlich, A.1    Noo, F.2
  • 27
    • 3042821092 scopus 로고    scopus 로고
    • Weighted FBP-a simple approximate 3D FBP algorithm for multislice spiral CT with good dose usage for arbitrary pitch
    • 10.1088/0031-9155/49/11/007
    • K. Stierstorfer, A. Rauscher, J. Boese, H. Bruder, S. Schaller, and T. Flohr, Weighted FBP-a simple approximate 3D FBP algorithm for multislice spiral CT with good dose usage for arbitrary pitch., Phys. Med. Biol. 49, 2209-2218 (2004). 10.1088/0031-9155/49/11/007
    • (2004) Phys. Med. Biol. , vol.49 , pp. 2209-2218
    • Stierstorfer, K.1    Rauscher, A.2    Boese, J.3    Bruder, H.4    Schaller, S.5    Flohr, T.6
  • 31
    • 0032742081 scopus 로고    scopus 로고
    • Dose reduction in CT by anatomically adapted tube current modulation. II. Phantom measurements
    • 10.1118/1.598738
    • W. A. Kalender, H. Wolf, and C. Suess, Dose reduction in CT by anatomically adapted tube current modulation. II. Phantom measurements., Med. Phys. 26, 2248-2253 (1999). 10.1118/1.598738
    • (1999) Med. Phys. , vol.26 , pp. 2248-2253
    • Kalender, W.A.1    Wolf, H.2    Suess, C.3
  • 34
    • 0032744531 scopus 로고    scopus 로고
    • Dose reduction in CT by anatomically adapted tube current modulation. I. Simulation studies
    • 10.1118/1.598779
    • M. Gies, W. A. Kalender, H. Wolf, and C. Suess, Dose reduction in CT by anatomically adapted tube current modulation. I. Simulation studies., Med. Phys. 26, 2235-2247 (1999). 10.1118/1.598779
    • (1999) Med. Phys. , vol.26 , pp. 2235-2247
    • Gies, M.1    Kalender, W.A.2    Wolf, H.3    Suess, C.4
  • 38
    • 0035080793 scopus 로고    scopus 로고
    • Determination of the presampled MTF in computed tomography
    • 10.1118/1.1350438
    • J. M. Boone, Determination of the presampled MTF in computed tomography., Med. Phys. 28, 356-360 (2001). 10.1118/1.1350438
    • (2001) Med. Phys. , vol.28 , pp. 356-360
    • Boone, J.M.1
  • 39
    • 1842865422 scopus 로고    scopus 로고
    • A framework for noise-power spectrum analysis of multidimensional images
    • 10.1118/1.1513158
    • J. H. Siewerdsen, I. A. Cunningham, and D. A. Jaffray, A framework for noise-power spectrum analysis of multidimensional images., Med. Phys. 29, 2655-2671 (2002). 10.1118/1.1513158
    • (2002) Med. Phys. , vol.29 , pp. 2655-2671
    • Siewerdsen, J.H.1    Cunningham, I.A.2    Jaffray, D.A.3
  • 40
    • 84876160428 scopus 로고    scopus 로고
    • Prediction of human observer performance in a 2-alternative forced choice low-contrast detection task using channelized Hotelling observer: Impact of radiation dose and reconstruction algorithms
    • (9p). 10.1118/1.4794498
    • L. Yu, S. Leng, L. Chen, J. M. Kofler, R. E. Carter, and C. H. McCollough, Prediction of human observer performance in a 2-alternative forced choice low-contrast detection task using channelized Hotelling observer: Impact of radiation dose and reconstruction algorithms., Med. Phys. 40, 041908 (9pp.) (2013). 10.1118/1.4794498
    • (2013) Med. Phys. , vol.40 , pp. 041908
    • Yu, L.1    Leng, S.2    Chen, L.3    Kofler, J.M.4    Carter, R.E.5    McCollough, C.H.6
  • 41
    • 84863891082 scopus 로고    scopus 로고
    • Development and validation of a practical lower-dose-simulation tool for optimizing computed tomography scan protocols
    • 10.1097/RCT.0b013e318258e891
    • L. Yu, M. Shiung, D. Jondal, and C. H. McCollough, Development and validation of a practical lower-dose-simulation tool for optimizing computed tomography scan protocols., J. Comput. Assist. Tomogr. 36, 477-487 (2012). 10.1097/RCT.0b013e318258e891
    • (2012) J. Comput. Assist. Tomogr. , vol.36 , pp. 477-487
    • Yu, L.1    Shiung, M.2    Jondal, D.3    McCollough, C.H.4
  • 42
    • 84899799000 scopus 로고    scopus 로고
    • TU-A-201B-03: Dose reduction and image quality benefits using model based iterative reconstruction (MBIR) technique for computed tomography
    • 10.1118/1.3469177
    • G. Yadava, S. Kulkarni, Z. R. Colon, J. Thibault, and J. Hsieh, TU-A-201B-03: Dose reduction and image quality benefits using model based iterative reconstruction (MBIR) technique for computed tomography., Med. Phys. 37, 3372 (2010). 10.1118/1.3469177
    • (2010) Med. Phys. , vol.37 , pp. 3372
    • Yadava, G.1    Kulkarni, S.2    Colon, Z.R.3    Thibault, J.4    Hsieh, J.5
  • 44
    • 48249103911 scopus 로고    scopus 로고
    • Investigation of image noise in cone-beam CT imaging due to photon counting statistics with the Feldkamp algorithm by computer simulations
    • Y. Zhang and R. Ning, Investigation of image noise in cone-beam CT imaging due to photon counting statistics with the Feldkamp algorithm by computer simulations., J. X-Ray Sci. Technol. 16, 143-158 (2008).
    • (2008) J. X-Ray Sci. Technol. , vol.16 , pp. 143-158
    • Zhang, Y.1    Ning, R.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.