메뉴 건너뛰기




Volumn 16, Issue 2, 2008, Pages 143-158

Investigation of image noise in cone-beam CT imaging due to photon counting statistics with the Feldkamp algorithm by computer simulations

Author keywords

Cone beam CT; Image noise; Noise distribution; Photon counting; Statistics

Indexed keywords

BOOLEAN FUNCTIONS; COMPUTATIONAL METHODS; COMPUTER SIMULATION; COMPUTERIZED TOMOGRAPHY; DETECTORS; ELECTRIC INSTRUMENT TRANSFORMERS; IMAGE PROCESSING; IMAGE QUALITY; IMAGE RECONSTRUCTION; IMAGING SYSTEMS; IMAGING TECHNIQUES; MEDICAL IMAGING; PARAMETER ESTIMATION; PHOTONS; REPAIR; RESTORATION; STATISTICAL METHODS;

EID: 48249103911     PISSN: 08953996     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (23)

References (25)
  • 1
    • 0035190741 scopus 로고    scopus 로고
    • Dedicated breast CT: Radiation dose and image quality evaluation
    • J.M. Boone, T.R. Nelson, K.K. Lindfors and J.A. Seibert, Dedicated breast CT: radiation dose and image quality evaluation, Radiology 221 (2001), 657-667.
    • (2001) Radiology , vol.221 , pp. 657-667
    • Boone, J.M.1    Nelson, T.R.2    Lindfors, K.K.3    Seibert, J.A.4
  • 2
    • 0035999405 scopus 로고    scopus 로고
    • Cone-beam volume CT breast imaging: Feasibility study
    • B. Chen and R. Ning, Cone-beam volume CT breast imaging: feasibility study, Med Phys 29 (2002), 755-770.
    • (2002) Med Phys , vol.29 , pp. 755-770
    • Chen, B.1    Ning, R.2
  • 4
    • 0642334597 scopus 로고    scopus 로고
    • Computed-assisted simulations in orthodontic diagnosis and the application of a new cone beam X-ray computed tomography
    • K. Maki, N. Inou, A. Takanishi and A.J. Miller, Computed-assisted simulations in orthodontic diagnosis and the application of a new cone beam X-ray computed tomography, Orthod Craniofac Res 6(Suppl1) (2003), 95-101.
    • (2003) Orthod Craniofac Res , vol.6 , Issue.SUPPL.1 , pp. 95-101
    • Maki, K.1    Inou, N.2    Takanishi, A.3    Miller, A.J.4
  • 5
    • 3042784991 scopus 로고    scopus 로고
    • Micro-calcification detection using cone-beam CT mammography with a flat-panel imager
    • X. Gong, A.A. Vedula and S.J. Glick, Micro-calcification detection using cone-beam CT mammography with a flat-panel imager, Phys Med Biol 49 (2004), 2183-2195.
    • (2004) Phys Med Biol , vol.49 , pp. 2183-2195
    • Gong, X.1    Vedula, A.A.2    Glick, S.J.3
  • 6
    • 23844527296 scopus 로고    scopus 로고
    • Flat panel detector-based cone beam CT lung imaging: Preliminary system evaluation
    • R. Ning, D. Conover, Y. Yu, W. Cai and X. Lu, Flat panel detector-based cone beam CT lung imaging: preliminary system evaluation, Pro SPIE Medical Imaging 5745 (2005), 147-158.
    • (2005) Pro SPIE Medical Imaging , vol.5745 , pp. 147-158
    • Ning, R.1    Conover, D.2    Yu, Y.3    Cai, W.4    Lu, X.5
  • 7
    • 0018197135 scopus 로고
    • Statistical limitations in computed tomography
    • J.C. Gore and P.S. Tofts, Statistical limitations in computed tomography, Phys Med Biol 23 (1978), 1176-1182.
    • (1978) Phys Med Biol , vol.23 , pp. 1176-1182
    • Gore, J.C.1    Tofts, P.S.2
  • 8
    • 0017328286 scopus 로고
    • Noise due to photon counting statistics in computed x-ray tomography
    • D.A. Chesler, S.J. Riederer and N.J. Pelc, Noise due to photon counting statistics in computed x-ray tomography, J Comput Assist Tomog 1 (1977), 64-74.
    • (1977) J Comput Assist Tomog , vol.1 , pp. 64-74
    • Chesler, D.A.1    Riederer, S.J.2    Pelc, N.J.3
  • 9
    • 0018390921 scopus 로고
    • Optimal processing of computed tompgraphy images using experimentally measured noise properties
    • R.E. Alvarez and J.P. Stonestrom, Optimal processing of computed tompgraphy images using experimentally measured noise properties, J Comput Assist Tomog 3 (1979), 77-84.
    • (1979) J Comput Assist Tomog , vol.3 , pp. 77-84
    • Alvarez, R.E.1    Stonestrom, J.P.2
  • 10
    • 0017456809 scopus 로고
    • Reconstruction of objects from their projections: The influence of measurement errors on the reconstruction
    • G. Kowalski, Reconstruction of objects from their projections: The influence of measurement errors on the reconstruction, IEEE Trans Nucl Sci NS 24 (1977), 850-864.
    • (1977) IEEE Trans Nucl Sci NS , vol.24 , pp. 850-864
    • Kowalski, G.1
  • 11
    • 0023199089 scopus 로고
    • The noise power spectrum of CT images
    • M.F. Kijewski and P.F. Judy, The noise power spectrum of CT images, Phys Med Biol 32 (1987), 565-575.
    • (1987) Phys Med Biol , vol.32 , pp. 565-575
    • Kijewski, M.F.1    Judy, P.F.2
  • 12
    • 0017800671 scopus 로고
    • The noise power spectrum in computed x-ray tomography
    • S.J. Riederer, N.J. Pelc and D.A. Chesler, The noise power spectrum in computed x-ray tomography, Phys Med Biol 23 (1978), 446-454.
    • (1978) Phys Med Biol , vol.23 , pp. 446-454
    • Riederer, S.J.1    Pelc, N.J.2    Chesler, D.A.3
  • 13
    • 0032692240 scopus 로고    scopus 로고
    • A simple theorem relating noise and patient dose in computed tomography
    • M.D. Harpen, A simple theorem relating noise and patient dose in computed tomography, Med Phys 26 (1999), 2231-2234.
    • (1999) Med Phys , vol.26 , pp. 2231-2234
    • Harpen, M.D.1
  • 14
    • 0030866638 scopus 로고    scopus 로고
    • Nonstationary noise characteristics of the helical scan and its impact on image quality and artifacts
    • J. Hsieh, Nonstationary noise characteristics of the helical scan and its impact on image quality and artifacts, Med Phys 24(9) (1997), 1375-1384.
    • (1997) Med Phys , vol.24 , Issue.9 , pp. 1375-1384
    • Hsieh, J.1
  • 16
    • 0033730497 scopus 로고    scopus 로고
    • Cone-Beam CT with a flat-panel imager: Noise considerations for fully 3-D computed tomography
    • J.H. Siewerdsen and D.A. Jaffray, Cone-Beam CT with a flat-panel imager: Noise considerations for fully 3-D computed tomography, Proc SPIE 3977 (2000), 408-416.
    • (2000) Proc SPIE , vol.3977 , pp. 408-416
    • Siewerdsen, J.H.1    Jaffray, D.A.2
  • 17
    • 0041375307 scopus 로고    scopus 로고
    • Three-dimensional NEQ transfer characteristics of volume CT using direct and indirect-detection flat-panel imagers
    • J.H. Siewerdsen and D.A. Jaffray, Three-dimensional NEQ transfer characteristics of volume CT using direct and indirect-detection flat-panel imagers, Proc SPIE 5030 (2003), 92-102.
    • (2003) Proc SPIE , vol.5030 , pp. 92-102
    • Siewerdsen, J.H.1    Jaffray, D.A.2
  • 22
    • 48249157176 scopus 로고    scopus 로고
    • The Art of Computer Programming
    • D.E. Knuth, Seminumerical Algorithms, (Volume 2), The Art of Computer Programming, 1997.
    • (1997) Seminumerical Algorithms , vol.2
    • Knuth, D.E.1
  • 24
    • 0031019011 scopus 로고    scopus 로고
    • Empirical and theoretical investigation of the noise performance of indirect detection, active matrix flat-panel imagers (AMFPIs) for diagnostic radiology
    • J.H. Siewerdsen, Empirical and theoretical investigation of the noise performance of indirect detection, active matrix flat-panel imagers (AMFPIs) for diagnostic radiology, Med Phys 24(1) (1997), 71-89.
    • (1997) Med Phys , vol.24 , Issue.1 , pp. 71-89
    • Siewerdsen, J.H.1
  • 25
    • 23244442675 scopus 로고    scopus 로고
    • General system architecture, signal, and noise processes
    • Theoretical analysis of hybrid flat-panel detector arrays for digital x-ray fluoroscopy
    • S. Suryanarayanan, A. Karellas and S. Vedantham, Theoretical analysis of hybrid flat-panel detector arrays for digital x-ray fluoroscopy: General system architecture, signal, and noise processes, IEEE Sensors 1(2) (2001), 168-174.
    • (2001) IEEE Sensors , vol.1 , Issue.2 , pp. 168-174
    • Suryanarayanan, S.1    Karellas, A.2    Vedantham, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.