Volumn 12, Issue 1, 2014, Pages 103-106

Recommendations for performing thromboelastography/thromboelastometry in hemophilia: Communication from the SSC of the ISTH

Author keywords

[No Author keywords available]

Indexed keywords

KAOLIN; RECOMBINANT THROMBOPLASTIN; THROMBOPLASTIN;

EID: 84891893038     PISSN: 15387933     EISSN: 15387836     Source Type: Journal    
DOI: 10.1111/jth.12458     Document Type: Article
Times cited : (64)

References (12)
  • 1
    • 84877607719 scopus 로고    scopus 로고
    • Thrombin generation and whole blood viscoelastic assays in the management of hemophilia: current state of art and future perspectives
    • Young G, Sorensen B, Dargaud Y, Negrier C, Brummel-Ziedins K, Key NS. Thrombin generation and whole blood viscoelastic assays in the management of hemophilia: current state of art and future perspectives. Blood 2013; 121: 1944-50.
    • (2013) Blood , vol.121 , pp. 1944-1950
    • Young, G.1    Sorensen, B.2    Dargaud, Y.3    Negrier, C.4    Brummel-Ziedins, K.5    Key, N.S.6
  • 2
    • 77953577635 scopus 로고    scopus 로고
    • Comparison of kaolin and tissue factor activated thromboelastography in haemophilia
    • Young G, Zhang R, Miller R, Yassin D, Nugent DJ. Comparison of kaolin and tissue factor activated thromboelastography in haemophilia. Haemophilia 2010; 16: 518-24.
    • (2010) Haemophilia , vol.16 , pp. 518-524
    • Young, G.1    Zhang, R.2    Miller, R.3    Yassin, D.4    Nugent, D.J.5
  • 3
    • 77955714195 scopus 로고    scopus 로고
    • Optimizing thrombelastography (TEG) assay conditions to monitor rFVIIa (NovoSeven) therapy in haemophilia A patients
    • Viuff D, Andersen S, Sorensen BB, Lethagen S. Optimizing thrombelastography (TEG) assay conditions to monitor rFVIIa (NovoSeven) therapy in haemophilia A patients. Thromb Res 2010; 126: 144-9.
    • (2010) Thromb Res , vol.126 , pp. 144-149
    • Viuff, D.1    Andersen, S.2    Sorensen, B.B.3    Lethagen, S.4
  • 4
    • 13244264708 scopus 로고    scopus 로고
    • Clinical measurement of thrombin generation by calibrated automated thrombography requires contact factor inhibition
    • Luddington R, Baglin T. Clinical measurement of thrombin generation by calibrated automated thrombography requires contact factor inhibition. J Thromb Haemost 2004; 2: 1954-9.
    • (2004) J Thromb Haemost , vol.2 , pp. 1954-1959
    • Luddington, R.1    Baglin, T.2
  • 5
    • 33645650134 scopus 로고    scopus 로고
    • Elimination of contact factor activation improves measurement of platelet-dependent thrombin generation by calibrated automated thrombography at low-concentration tissue factor
    • Dargaud Y, Luddington R, Baglin TP. Elimination of contact factor activation improves measurement of platelet-dependent thrombin generation by calibrated automated thrombography at low-concentration tissue factor. J Thromb Haemost 2006; 4: 1160-1.
    • (2006) J Thromb Haemost , vol.4 , pp. 1160-1161
    • Dargaud, Y.1    Luddington, R.2    Baglin, T.P.3
  • 6
    • 79959560620 scopus 로고    scopus 로고
    • Monitoring low dose recombinant factor VIIa therapy in patients with severe factor XI deficiency undergoing surgery
    • Riddell A, Abdul-Kadir R, Pollard D, Tuddenham E, Gomez K. Monitoring low dose recombinant factor VIIa therapy in patients with severe factor XI deficiency undergoing surgery. Thromb Haemost 2011; 106: 521-7.
    • (2011) Thromb Haemost , vol.106 , pp. 521-527
    • Riddell, A.1    Abdul-Kadir, R.2    Pollard, D.3    Tuddenham, E.4    Gomez, K.5
  • 8
    • 2042441122 scopus 로고    scopus 로고
    • Thromboelastography with citrated blood: comparability with native blood, stability of citrate storage and effect of repeated sampling
    • Zambruni A, Thalheimer U, Leandro G, Perry D, Burroughs AK. Thromboelastography with citrated blood: comparability with native blood, stability of citrate storage and effect of repeated sampling. Blood Coagul Fibrinolysis 2004; 15: 103-7.
    • (2004) Blood Coagul Fibrinolysis , vol.15 , pp. 103-107
    • Zambruni, A.1    Thalheimer, U.2    Leandro, G.3    Perry, D.4    Burroughs, A.K.5
  • 9
    • 0038554771 scopus 로고    scopus 로고
    • Whole blood coagulation thrombelastographic profiles employing minimal tissue factor activation
    • Sorensen B, Johansen P, Christiansen K, Woelke M, Ingerslev J. Whole blood coagulation thrombelastographic profiles employing minimal tissue factor activation. J Thromb Haemost 2003; 1: 551-8.
    • (2003) J Thromb Haemost , vol.1 , pp. 551-558
    • Sorensen, B.1    Johansen, P.2    Christiansen, K.3    Woelke, M.4    Ingerslev, J.5
  • 10
    • 27744533650 scopus 로고    scopus 로고
    • Tailoring haemostatic treatment to patient requirements - an update on monitoring haemostatic response using thrombelastography
    • Sorensen B, Ingerslev J. Tailoring haemostatic treatment to patient requirements - an update on monitoring haemostatic response using thrombelastography. Haemophilia 2005; 11(Suppl 1): 1-6.
    • (2005) Haemophilia , vol.11 , Issue.SUPPL 1 , pp. 1-6
    • Sorensen, B.1    Ingerslev, J.2
  • 11
    • 43449092203 scopus 로고    scopus 로고
    • Evaluation of thromboelastography for monitoring recombinant activated factor VII ex vivo in haemophilia A and B patients with inhibitors: a multicentre trial
    • Young G, Ebbesen LS, Viuff D, Di Paola J, Konkle BA, Negrier C, Pasi J, Ingerslev J. Evaluation of thromboelastography for monitoring recombinant activated factor VII ex vivo in haemophilia A and B patients with inhibitors: a multicentre trial. Blood Coagul Fibrinolysis 2008; 19: 276-82.
    • (2008) Blood Coagul Fibrinolysis , vol.19 , pp. 276-282
    • Young, G.1    Ebbesen, L.S.2    Viuff, D.3    Di Paola, J.4    Konkle, B.A.5    Negrier, C.6    Pasi, J.7    Ingerslev, J.8
  • 12
    • 33947494621 scopus 로고    scopus 로고
    • Factor VIIa analogue (V158D/E296V/M298Q-FVIIa) normalises clot formation in whole blood from patients with severe haemophilia A
    • Sorensen B, Persson E, Ingerslev J. Factor VIIa analogue (V158D/E296V/M298Q-FVIIa) normalises clot formation in whole blood from patients with severe haemophilia A. Br J Haematol 2007; 137: 158-65.
    • (2007) Br J Haematol , vol.137 , pp. 158-165
    • Sorensen, B.1    Persson, E.2    Ingerslev, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.