Volumn 55, Issue , 2014, Pages 294-300
|
Realization of an ultra-sensitive hydrogen peroxide sensor with conductance change of horseradish peroxidase-immobilized polyaniline and investigation of the sensing mechanism
|
Author keywords
Conducting polymer; Disposable sensors; Horseradish peroxidase; Hydrogen peroxide; Polyaniline
|
Indexed keywords
BERYLLIUM COMPOUNDS;
CONDUCTING POLYMERS;
COST EFFECTIVENESS;
FOOD PRODUCTS;
HYDROGEN PEROXIDE;
PEROXIDES;
POLYANILINE;
DETECTION MECHANISM;
DISPOSABLE SENSORS;
HORSE-RADISH PEROXIDASE;
HYDROGEN PEROXIDE DETECTIONS;
HYDROGEN PEROXIDE SENSOR;
OXIDATION/REDUCTION;
POLYANILINE THIN FILMS;
POLYANILINES (PANI);
OXIDATION;
HORSERADISH PEROXIDASE;
HYDROGEN PEROXIDE;
POLYANILINE;
ARTICLE;
CONCENTRATION (PARAMETERS);
COST EFFECTIVENESS ANALYSIS;
ELECTRIC CONDUCTIVITY;
ELECTROCHEMICAL DETECTION;
ELECTRONIC SENSOR;
ENZYME ACTIVITY;
ENZYME IMMOBILIZATION;
ENZYME INHIBITION;
ENZYME MECHANISM;
FILM;
LIMIT OF DETECTION;
OXIDATION;
SENSITIVITY AND SPECIFICITY;
SIGNAL DETECTION;
VALIDATION PROCESS;
CONDUCTING POLYMER;
DISPOSABLE SENSORS;
HORSERADISH PEROXIDASE;
HYDROGEN PEROXIDE;
POLYANILINE;
ANILINE COMPOUNDS;
BIOSENSING TECHNIQUES;
CONDUCTOMETRY;
ELECTRIC CONDUCTIVITY;
ELECTRODES;
ENZYMES, IMMOBILIZED;
EQUIPMENT DESIGN;
EQUIPMENT FAILURE ANALYSIS;
HORSERADISH PEROXIDASE;
HYDROGEN PEROXIDE;
REPRODUCIBILITY OF RESULTS;
SENSITIVITY AND SPECIFICITY;
|
EID: 84891636098
PISSN: 09565663
EISSN: 18734235
Source Type: Journal
DOI: 10.1016/j.bios.2013.12.029 Document Type: Article |
Times cited : (31)
|
References (28)
|