-
1
-
-
84877699481
-
-
IWA Publishing, London, UK
-
Rieger L., Gillot S., Langergraber G., Ohtsuki T., Shaw A., Takács I., Winkler S. Guidelines for Using Activated Sludge Models. IWA Scientific and Technical Report 2012, IWA Publishing, London, UK.
-
(2012)
Guidelines for Using Activated Sludge Models. IWA Scientific and Technical Report
-
-
Rieger, L.1
Gillot, S.2
Langergraber, G.3
Ohtsuki, T.4
Shaw, A.5
Takács, I.6
Winkler, S.7
-
2
-
-
0023341639
-
A general model for single-sludge wastewater treatment systems
-
Henze M., Grady C.P.L., Gujer W., Marais G.v.R., Matsuo T. A general model for single-sludge wastewater treatment systems. Water Res. 1987, 21:505-515.
-
(1987)
Water Res.
, vol.21
, pp. 505-515
-
-
Henze, M.1
Grady, C.P.L.2
Gujer, W.3
Marais, G.4
Matsuo, T.5
-
3
-
-
0003683669
-
-
International Association on Water Quality, London, UK
-
Ekama G.A., Barnard G.L., Gunthert F.W., Krebs P., McCorquodale J.A., Parker D.S., et al. Secondary Settling Tanks: Theory, Modelling, Design and Operation 1997, International Association on Water Quality, London, UK.
-
(1997)
Secondary Settling Tanks: Theory, Modelling, Design and Operation
-
-
Ekama, G.A.1
Barnard, G.L.2
Gunthert, F.W.3
Krebs, P.4
McCorquodale, J.A.5
Parker, D.S.6
-
4
-
-
0026238002
-
A dynamic model of the clarification-thickening process
-
Takács I., Patry G., Nolasco D. A dynamic model of the clarification-thickening process. Water Res. 1991, 25:1263-1271.
-
(1991)
Water Res.
, vol.25
, pp. 1263-1271
-
-
Takács, I.1
Patry, G.2
Nolasco, D.3
-
5
-
-
0029859439
-
An evaluation of a dynamic model of the secondary clarifier
-
Jeppsson U., Diehl S. An evaluation of a dynamic model of the secondary clarifier. Water Sci. Technol. 1996, 34:19-26.
-
(1996)
Water Sci. Technol.
, vol.34
, pp. 19-26
-
-
Jeppsson, U.1
Diehl, S.2
-
6
-
-
79955811081
-
Shall we upgrade one-dimensional secondary settler models used in WWTP simulators?-An assessment of model structure uncertainty and its propagation
-
Plósz B.G., De Clercq J., Nopens I., Benedetti L., Vanrolleghem P.A. Shall we upgrade one-dimensional secondary settler models used in WWTP simulators?-An assessment of model structure uncertainty and its propagation. Water Sci. Technol. 2011, 63:1726-1738.
-
(2011)
Water Sci. Technol.
, vol.63
, pp. 1726-1738
-
-
Plósz, B.G.1
De Clercq, J.2
Nopens, I.3
Benedetti, L.4
Vanrolleghem, P.A.5
-
7
-
-
79951950171
-
A consistent modelling methodology for secondary settling tanks in wastewater treatment
-
Bürger R., Diehl S., Nopens I. A consistent modelling methodology for secondary settling tanks in wastewater treatment. Water Res. 2011, 45:2247-2260.
-
(2011)
Water Res.
, vol.45
, pp. 2247-2260
-
-
Bürger, R.1
Diehl, S.2
Nopens, I.3
-
8
-
-
34447102680
-
One-dimensional modelling of the secondary clarifier-factors affecting simulation in the clarification zone and the assessment of the thickening flow dependence
-
Plósz B.G., Weiss M., Printemps C., Essemiani K., Meinhold J. One-dimensional modelling of the secondary clarifier-factors affecting simulation in the clarification zone and the assessment of the thickening flow dependence. Water Res. 2007, 41:3359-3371.
-
(2007)
Water Res.
, vol.41
, pp. 3359-3371
-
-
Plósz, B.G.1
Weiss, M.2
Printemps, C.3
Essemiani, K.4
Meinhold, J.5
-
9
-
-
84862545439
-
Uncertainty analysis of WWTP control strategies made feasible
-
Benedetti L., Batstone D.J., De Baets B., Nopens I. Uncertainty analysis of WWTP control strategies made feasible. Water Qual. Res. J. Can. 2011, 47:14-29.
-
(2011)
Water Qual. Res. J. Can.
, vol.47
, pp. 14-29
-
-
Benedetti, L.1
Batstone, D.J.2
De Baets, B.3
Nopens, I.4
-
10
-
-
78650416295
-
Global sensitivity analysis in wastewater treatment plant model applications: prioritizing sources of uncertainty
-
Sin G., Gernaey K.V., Neumann M.B., van Loosdrecht M.C.M., Gujer W. Global sensitivity analysis in wastewater treatment plant model applications: prioritizing sources of uncertainty. Water Res. 2011, 45:639-651.
-
(2011)
Water Res.
, vol.45
, pp. 639-651
-
-
Sin, G.1
Gernaey, K.V.2
Neumann, M.B.3
van Loosdrecht, M.C.M.4
Gujer, W.5
-
11
-
-
37249075012
-
Benchmark simulation model no 2: general protocol and exploratory case studies
-
Jeppsson U., Pons M.-N., Nopens I., Alex J., Copp J.B., V Gernaey K., et al. Benchmark simulation model no 2: general protocol and exploratory case studies. Water Sci. Technol. 2007, 56:67-78.
-
(2007)
Water Sci. Technol.
, vol.56
, pp. 67-78
-
-
Jeppsson, U.1
Pons, M.-N.2
Nopens, I.3
Alex, J.4
Copp, J.B.5
Gernaey, K.V.6
-
12
-
-
84861733671
-
Benchmarking of Control Strategies for Wastewater Treatment Plants (Scientific and Technical Report), London, UK
-
K.V. Gernaey, U. Jeppsson, P.A. Vanrolleghem, J.B. Copp, Benchmarking of Control Strategies for Wastewater Treatment Plants (Scientific and Technical Report), London, UK, 2013.
-
(2013)
-
-
Gernaey, K.V.1
Jeppsson, U.2
Vanrolleghem, P.A.3
Copp, J.B.4
-
13
-
-
79960118125
-
Dynamic influent pollutant disturbance scenario generation using a phenomenological modelling approach
-
Gernaey K.V., Flores-Alsina X., Rosen C., Benedetti L., Jeppsson U. Dynamic influent pollutant disturbance scenario generation using a phenomenological modelling approach. Environ. Model. Softw. 2011, 26:1255-1267.
-
(2011)
Environ. Model. Softw.
, vol.26
, pp. 1255-1267
-
-
Gernaey, K.V.1
Flores-Alsina, X.2
Rosen, C.3
Benedetti, L.4
Jeppsson, U.5
-
14
-
-
66149171359
-
Uncertainty analysis in WWTP model applications: a critical discussion using an example from design
-
Sin G., Gernaey K.V., Neumann M.B., van Loosdrecht M.C.M., Gujer W. Uncertainty analysis in WWTP model applications: a critical discussion using an example from design. Water Res. 2009, 43:2894-2906.
-
(2009)
Water Res.
, vol.43
, pp. 2894-2906
-
-
Sin, G.1
Gernaey, K.V.2
Neumann, M.B.3
van Loosdrecht, M.C.M.4
Gujer, W.5
-
15
-
-
84889461919
-
-
John Wiley & Sons, West Sussex, England
-
Saltelli A., Ratto M., Andres T., Campolongo F. Global sensitivity analysis: the primer 2008, John Wiley & Sons, West Sussex, England.
-
(2008)
Global sensitivity analysis: the primer
-
-
Saltelli, A.1
Ratto, M.2
Andres, T.3
Campolongo, F.4
-
16
-
-
84952096573
-
Factorial sampling plans for preliminary computational experiments
-
Morris M. Factorial sampling plans for preliminary computational experiments. Technometrics 1991, 33:161-174.
-
(1991)
Technometrics
, vol.33
, pp. 161-174
-
-
Morris, M.1
-
17
-
-
0038476492
-
Latin hypercube sampling and the propagation of uncertainty in analyses of complex systems
-
Helton J.C., Davis F.J. Latin hypercube sampling and the propagation of uncertainty in analyses of complex systems. Reliab. Eng. Syst. Saf. 2003, 81:23-69.
-
(2003)
Reliab. Eng. Syst. Saf.
, vol.81
, pp. 23-69
-
-
Helton, J.C.1
Davis, F.J.2
-
18
-
-
7944223017
-
Comparison of the 1D flux theory with a 2D hydrodynamic secondary settling tank model
-
Ekama G., Marais P. Comparison of the 1D flux theory with a 2D hydrodynamic secondary settling tank model. Water Sci. Technol. 2004, 50:195-204.
-
(2004)
Water Sci. Technol.
, vol.50
, pp. 195-204
-
-
Ekama, G.1
Marais, P.2
|