메뉴 건너뛰기




Volumn 241, Issue , 2014, Pages 28-34

Influence of selecting secondary settling tank sub-models on the calibration of WWTP models - A global sensitivity analysis using BSM2

Author keywords

Activated sludge models, ASMs; Benchmark simulation model No. 2, BSM2; Good modelling practice; Morris screening; Uncertainty analysis; Wastewater treatment plant, WWTP

Indexed keywords

ACTIVATED SLUDGE MODEL; GOOD MODELLING PRACTICES; MORRIS SCREENINGS; SIMULATION MODEL; WASTEWATER TREATMENT PLANTS;

EID: 84891311144     PISSN: 13858947     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.cej.2013.12.015     Document Type: Article
Times cited : (28)

References (18)
  • 2
    • 0023341639 scopus 로고
    • A general model for single-sludge wastewater treatment systems
    • Henze M., Grady C.P.L., Gujer W., Marais G.v.R., Matsuo T. A general model for single-sludge wastewater treatment systems. Water Res. 1987, 21:505-515.
    • (1987) Water Res. , vol.21 , pp. 505-515
    • Henze, M.1    Grady, C.P.L.2    Gujer, W.3    Marais, G.4    Matsuo, T.5
  • 4
    • 0026238002 scopus 로고
    • A dynamic model of the clarification-thickening process
    • Takács I., Patry G., Nolasco D. A dynamic model of the clarification-thickening process. Water Res. 1991, 25:1263-1271.
    • (1991) Water Res. , vol.25 , pp. 1263-1271
    • Takács, I.1    Patry, G.2    Nolasco, D.3
  • 5
    • 0029859439 scopus 로고    scopus 로고
    • An evaluation of a dynamic model of the secondary clarifier
    • Jeppsson U., Diehl S. An evaluation of a dynamic model of the secondary clarifier. Water Sci. Technol. 1996, 34:19-26.
    • (1996) Water Sci. Technol. , vol.34 , pp. 19-26
    • Jeppsson, U.1    Diehl, S.2
  • 6
    • 79955811081 scopus 로고    scopus 로고
    • Shall we upgrade one-dimensional secondary settler models used in WWTP simulators?-An assessment of model structure uncertainty and its propagation
    • Plósz B.G., De Clercq J., Nopens I., Benedetti L., Vanrolleghem P.A. Shall we upgrade one-dimensional secondary settler models used in WWTP simulators?-An assessment of model structure uncertainty and its propagation. Water Sci. Technol. 2011, 63:1726-1738.
    • (2011) Water Sci. Technol. , vol.63 , pp. 1726-1738
    • Plósz, B.G.1    De Clercq, J.2    Nopens, I.3    Benedetti, L.4    Vanrolleghem, P.A.5
  • 7
    • 79951950171 scopus 로고    scopus 로고
    • A consistent modelling methodology for secondary settling tanks in wastewater treatment
    • Bürger R., Diehl S., Nopens I. A consistent modelling methodology for secondary settling tanks in wastewater treatment. Water Res. 2011, 45:2247-2260.
    • (2011) Water Res. , vol.45 , pp. 2247-2260
    • Bürger, R.1    Diehl, S.2    Nopens, I.3
  • 8
    • 34447102680 scopus 로고    scopus 로고
    • One-dimensional modelling of the secondary clarifier-factors affecting simulation in the clarification zone and the assessment of the thickening flow dependence
    • Plósz B.G., Weiss M., Printemps C., Essemiani K., Meinhold J. One-dimensional modelling of the secondary clarifier-factors affecting simulation in the clarification zone and the assessment of the thickening flow dependence. Water Res. 2007, 41:3359-3371.
    • (2007) Water Res. , vol.41 , pp. 3359-3371
    • Plósz, B.G.1    Weiss, M.2    Printemps, C.3    Essemiani, K.4    Meinhold, J.5
  • 10
    • 78650416295 scopus 로고    scopus 로고
    • Global sensitivity analysis in wastewater treatment plant model applications: prioritizing sources of uncertainty
    • Sin G., Gernaey K.V., Neumann M.B., van Loosdrecht M.C.M., Gujer W. Global sensitivity analysis in wastewater treatment plant model applications: prioritizing sources of uncertainty. Water Res. 2011, 45:639-651.
    • (2011) Water Res. , vol.45 , pp. 639-651
    • Sin, G.1    Gernaey, K.V.2    Neumann, M.B.3    van Loosdrecht, M.C.M.4    Gujer, W.5
  • 12
    • 84861733671 scopus 로고    scopus 로고
    • Benchmarking of Control Strategies for Wastewater Treatment Plants (Scientific and Technical Report), London, UK
    • K.V. Gernaey, U. Jeppsson, P.A. Vanrolleghem, J.B. Copp, Benchmarking of Control Strategies for Wastewater Treatment Plants (Scientific and Technical Report), London, UK, 2013.
    • (2013)
    • Gernaey, K.V.1    Jeppsson, U.2    Vanrolleghem, P.A.3    Copp, J.B.4
  • 13
    • 79960118125 scopus 로고    scopus 로고
    • Dynamic influent pollutant disturbance scenario generation using a phenomenological modelling approach
    • Gernaey K.V., Flores-Alsina X., Rosen C., Benedetti L., Jeppsson U. Dynamic influent pollutant disturbance scenario generation using a phenomenological modelling approach. Environ. Model. Softw. 2011, 26:1255-1267.
    • (2011) Environ. Model. Softw. , vol.26 , pp. 1255-1267
    • Gernaey, K.V.1    Flores-Alsina, X.2    Rosen, C.3    Benedetti, L.4    Jeppsson, U.5
  • 14
    • 66149171359 scopus 로고    scopus 로고
    • Uncertainty analysis in WWTP model applications: a critical discussion using an example from design
    • Sin G., Gernaey K.V., Neumann M.B., van Loosdrecht M.C.M., Gujer W. Uncertainty analysis in WWTP model applications: a critical discussion using an example from design. Water Res. 2009, 43:2894-2906.
    • (2009) Water Res. , vol.43 , pp. 2894-2906
    • Sin, G.1    Gernaey, K.V.2    Neumann, M.B.3    van Loosdrecht, M.C.M.4    Gujer, W.5
  • 16
    • 84952096573 scopus 로고
    • Factorial sampling plans for preliminary computational experiments
    • Morris M. Factorial sampling plans for preliminary computational experiments. Technometrics 1991, 33:161-174.
    • (1991) Technometrics , vol.33 , pp. 161-174
    • Morris, M.1
  • 17
    • 0038476492 scopus 로고    scopus 로고
    • Latin hypercube sampling and the propagation of uncertainty in analyses of complex systems
    • Helton J.C., Davis F.J. Latin hypercube sampling and the propagation of uncertainty in analyses of complex systems. Reliab. Eng. Syst. Saf. 2003, 81:23-69.
    • (2003) Reliab. Eng. Syst. Saf. , vol.81 , pp. 23-69
    • Helton, J.C.1    Davis, F.J.2
  • 18
    • 7944223017 scopus 로고    scopus 로고
    • Comparison of the 1D flux theory with a 2D hydrodynamic secondary settling tank model
    • Ekama G., Marais P. Comparison of the 1D flux theory with a 2D hydrodynamic secondary settling tank model. Water Sci. Technol. 2004, 50:195-204.
    • (2004) Water Sci. Technol. , vol.50 , pp. 195-204
    • Ekama, G.1    Marais, P.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.