메뉴 건너뛰기




Volumn 9, Issue 1, 2014, Pages 334-343

Improvement of dynamic respiration monitoring through sensor fusion of accelerometer and gyro-sensor

Author keywords

Accelerometer; Exercise; Gyro sensor; Kalman filter; Respiration estimation

Indexed keywords

ALGORITHM'S PERFORMANCE; EXERCISE; GYRO SENSORS; PIEZOELECTRIC SENSORS; REAL TIME MONITORING; RESPIRATION MONITORING; RESPIRATION SIGNALS; TIME AND FREQUENCY DOMAINS;

EID: 84891136992     PISSN: 19750102     EISSN: None     Source Type: Journal    
DOI: 10.5370/JEET.2014.9.1.334     Document Type: Article
Times cited : (63)

References (20)
  • 1
    • 78651050823 scopus 로고
    • The effects on the respiration and performance during exercise of adding oxygen to the inspired air
    • R. Bannister and D. Cunningham, "The effects on the respiration and performance during exercise of adding oxygen to the inspired air," The Journal of physiology, vol. 125, pp. 118-137, 1954.
    • (1954) The Journal of Physiology , vol.125 , pp. 118-137
    • Bannister, R.1    Cunningham, D.2
  • 3
    • 61849135661 scopus 로고    scopus 로고
    • Estimation of respiratory waveform and heart rate using an accelerometer," Engineering in Medicine and Biology Society, EMBS 2008
    • D. Phan, S. Bonnet, R. Guillemaud, E. Castelli, and N. Pham Thi, "Estimation of respiratory waveform and heart rate using an accelerometer," Engineering in Medicine and Biology Society, EMBS 2008. 30th Annual International Conference of the IEEE pp. 4916-4919, 2008.
    • (2008) 30th Annual International Conference of the IEEE , pp. 4916-4919
    • Phan, D.1    Bonnet, S.2    Guillemaud, R.3    Castelli, E.4    Pham, T.N.5
  • 5
    • 77950208790 scopus 로고    scopus 로고
    • Principal Component Analysis as a tool for analyzing beat-to-beat changes in ECG features: Application to ECG-Derived Respiration
    • P. Langley, E. J. Bowers, and A. Murray, "Principal Component Analysis as a tool for analyzing beat-to-beat changes in ECG features: application to ECG-Derived Respiration," Biomedical Engineering, IEEE Transactions on, vol. 57, pp. 821-829, 2010.
    • (2010) Biomedical Engineering, IEEE Transactions On , vol.57 , pp. 821-829
    • Langley, P.1    Bowers, E.J.2    Murray, A.3
  • 6
    • 77956146112 scopus 로고    scopus 로고
    • Monitoring Respiratory Activity Using PPG Signals by Order Reduced-Modified Covariance AR Technique
    • 2010 4th International Conference on
    • K. V. Madhav, M. Raghuram, E. H. Krishna, and K. A. Reddy, "Monitoring Respiratory Activity Using PPG Signals by Order Reduced-Modified Covariance AR Technique," Bioinformatics and Biomedical Engineering (iCBBE), 2010 4th International Conference on, pp. 1-4, 2010.
    • (2010) Bioinformatics and Biomedical Engineering (iCBBE) , pp. 1-4
    • Madhav, K.V.1    Raghuram, M.2    Krishna, E.H.3    Reddy, K.A.4
  • 8
    • 57649244885 scopus 로고    scopus 로고
    • Monitoring and analysis of cardio respiratory and snoring signals by using an accelerometer Engineering in Medicine and Biology Society, 2007 EMBS 2007
    • D. S. Morillo, J. L. R. Ojeda, L. F. C. Foix, D. B. endón, and A. León, "Monitoring and analysis of cardio respiratory and snoring signals by using an accelerometer," Engineering in Medicine and Biology Society, 2007. EMBS 2007. 29th Annual International Conference of the IEEE, pp. 3942-3945, 2007.
    • (2007) 29th Annual International Conference of the IEEE , pp. 3942-3945
    • Morillo, D.S.1    Ojeda, J.L.R.2    Foix, L.F.C.3    Endón, D.B.4    León, A.5
  • 10
    • 77951021108 scopus 로고    scopus 로고
    • Performance evaluation of a tri-axial accelerometry-based respiration monitoring for ambient assisted living Engineering in Medicine and Biology Society, 2009 EMBC 2009
    • A. Jin, B. Yin, G. Morren, H. Duric, and R. Aarts, "Performance evaluation of a tri-axial accelerometry-based respiration monitoring for ambient assisted living," Engineering in Medicine and Biology Society, 2009. EMBC 2009. Annual International Conference of the IEEE, pp. 5677-5680, 2009.
    • (2009) Annual International Conference of the IEEE , pp. 5677-5680
    • Jin, A.1    Yin, B.2    Morren, G.3    Duric, H.4    Aarts, R.5
  • 15
    • 67650330020 scopus 로고    scopus 로고
    • Gyro sensor drift compensation by Kalman filter to control a mobile inverted pendulum robot system Industrial Technology, 2009 ICIT 2009
    • H. J. Lee and S. Jung, "Gyro sensor drift compensation by Kalman filter to control a mobile inverted pendulum robot system," Industrial Technology, 2009. ICIT 2009. IEEE International Conference on, pp. 1-6,2009.
    • (2009) IEEE International Conference On , pp. 1-6
    • Lee, H.J.1    Jung, S.2
  • 16
    • 33845529645 scopus 로고    scopus 로고
    • Design, implementation, and experimental results of a quaternion-based Kalman filter for human body motion tracking
    • X. Yun and E. R. Bachmann, "Design, implementation, and experimental results of a quaternion-based Kalman filter for human body motion tracking," Robotics, IEEE Transactions on, vol. 22, pp. 1216-1227, 2006.
    • (2006) Robotics, IEEE Transactions On , vol.22 , pp. 1216-1227
    • Yun, X.1    Bachmann, E.R.2
  • 17
    • 33746855962 scopus 로고    scopus 로고
    • Quaternion-based extended Kalman filter for determining orientation by inertial and magnetic sensing
    • A. M. Sabatini, "Quaternion-based extended Kalman filter for determining orientation by inertial and magnetic sensing," Biomedical Engineering, IEEE Transactions on, vol. 53, pp. 1346-1356, 2006.
    • (2006) Biomedical Engineering, IEEE Transactions On , vol.53 , pp. 1346-1356
    • Sabatini, A.M.1
  • 18
    • 0035558199 scopus 로고    scopus 로고
    • An extended Kalman filter for quaternion-based orientation estimation using MARG sensors
    • 2001 IEEE/RSJ International Conference on
    • J. L. Marins, X. Yun, E. R. Bachmann, R. B. McGhee, and M. J. Zyda, "An extended Kalman filter for quaternion-based orientation estimation using MARG sensors," Intelligent Robots and Systems, 2001. Proceedings. 2001 IEEE/RSJ International Conference on, pp. 2003-2011 vol. 4, 2011.
    • (2011) Intelligent Robots and Systems, 2001. Proceedings , vol.4 , pp. 2003-2011
    • Marins, J.L.1    Yun, X.2    Bachmann, E.R.3    McGhee, R.B.4    Zyda, M.J.5
  • 19
    • 37349005265 scopus 로고    scopus 로고
    • Breathing detection: Towards a miniaturized, wearable, battery-operated monitoring system
    • P. Corbishley and E. Rodríguez-Villegas, "Breathing detection: towards a miniaturized, wearable, battery-operated monitoring system," Biomedical Engineering, IEEE Transactions on, vol. 55, pp. 196-204, 2008.
    • (2008) Biomedical Engineering, IEEE Transactions On , vol.55 , pp. 196-204
    • Corbishley, P.1    Rodríguez-Villegas, E.2
  • 20
    • 51049104469 scopus 로고    scopus 로고
    • Estimation of respiratory waveform using an accelerometer Biomedical Imaging: From Nano to Macro, 2008 ISBI 2008
    • P. Hung, S. Bonnet, R. Guillemaud, E. Castelli, and P. Yen, "Estimation of respiratory waveform using an accelerometer," Biomedical Imaging: From Nano to Macro, 2008. ISBI 2008. 5th IEEE International Symposium on, pp. 1493-1496, 2008.
    • (2008) 5th IEEE International Symposium On , pp. 1493-1496
    • Hung, P.1    Bonnet, S.2    Guillemaud, R.3    Castelli, E.4    Yen, P.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.