메뉴 건너뛰기




Volumn 239, Issue , 2014, Pages 1-8

A system for accurate and automated injection of hyperpolarized substrate with minimal dead time and scalable volumes over a large range

Author keywords

Dead space minimization; Hyperpolarization; In vivo automated injection system; Large volume range

Indexed keywords

AREA UNDER THE CURVES; AUTOMATED INJECTION; COEFFICIENT OF VARIATION; DEAD SPACE; HYPERPOLARIZATION; KINETIC RATE CONSTANTS; LARGE VOLUMES; PHYSIOLOGICAL PARAMETERS;

EID: 84890709739     PISSN: 10907807     EISSN: 10960856     Source Type: Journal    
DOI: 10.1016/j.jmr.2013.10.024     Document Type: Article
Times cited : (7)

References (14)
  • 3
    • 78049307949 scopus 로고    scopus 로고
    • Detecting treatment response in a model of human breast adenocarcinoma using hyperpolarised [1-13C]pyruvate and [1,4-13C2]fumarate
    • T.H. Witney, M.I. Kettunen, D.E. Hu, F.A. Gallagher, S.E. Bohndiek, R. Napolitano, and K.M. Brindle Detecting treatment response in a model of human breast adenocarcinoma using hyperpolarised [1-13C]pyruvate and [1,4-13C2]fumarate Br. J. Cancer 103 2010 1400 1406
    • (2010) Br. J. Cancer , vol.103 , pp. 1400-1406
    • Witney, T.H.1    Kettunen, M.I.2    Hu, D.E.3    Gallagher, F.A.4    Bohndiek, S.E.5    Napolitano, R.6    Brindle, K.M.7
  • 6
    • 84864349557 scopus 로고    scopus 로고
    • Fully MR-compatible syringe pump for the controllable injection of hyperpolarized substrate in animals
    • S. Reynolds, S. Kazan, J. Bluff, M. Port, E. Wholey, G. Tozer, and M. Paley Fully MR-compatible syringe pump for the controllable injection of hyperpolarized substrate in animals Appl. Magn. Reson. 43 2012 263 273
    • (2012) Appl. Magn. Reson. , vol.43 , pp. 263-273
    • Reynolds, S.1    Kazan, S.2    Bluff, J.3    Port, M.4    Wholey, E.5    Tozer, G.6    Paley, M.7
  • 8
    • 77952925796 scopus 로고    scopus 로고
    • Rapid sample injection for hyperpolarized NMR spectroscopy
    • S. Bowen, and C. Hilty Rapid sample injection for hyperpolarized NMR spectroscopy Phys. Chem. Chem. Phys. 12 2010 5766 5770
    • (2010) Phys. Chem. Chem. Phys. , vol.12 , pp. 5766-5770
    • Bowen, S.1    Hilty, C.2
  • 13
    • 84883764512 scopus 로고    scopus 로고
    • A calibration-based approach to real-time in vivo monitoring of pyruvate C and C polarization using the J spectral asymmetry
    • J.Y. Lau, A.P. Chen, Y.P. Gu, C.H. Cunningham, A calibration-based approach to real-time in vivo monitoring of pyruvate C and C polarization using the J spectral asymmetry, NMR Biomed. (2013).
    • (2013) NMR Biomed
    • Lau, J.Y.1    Chen, A.P.2    Gu, Y.P.3    Cunningham, C.H.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.