메뉴 건너뛰기




Volumn , Issue , 1999, Pages 452-457

Automatic detection of the intimal and the adventitial layers of the common carotid artery wall in ultrasound B-mode images using snakes

Author keywords

[No Author keywords available]

Indexed keywords

COST FUNCTIONS; FREQUENCY RESPONSE; IMAGE SEGMENTATION; ULTRASONIC APPLICATIONS;

EID: 84890396989     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/ICIAP.1999.797637     Document Type: Conference Paper
Times cited : (34)

References (18)
  • 1
    • 0033531215 scopus 로고    scopus 로고
    • Carotid-artery intima and media thickness as a risk factor for myocardial infarction and stroke in older adults
    • D. H. O'Leary, et al., "Carotid-artery intima and media thickness as a risk factor for myocardial infarction and stroke in older adults," The New England Journal of Medicine, vol. 340, pp. 14-22, 1999.
    • (1999) The New England Journal of Medicine , vol.340 , pp. 14-22
    • O'leary, D.H.1
  • 2
    • 0032519844 scopus 로고    scopus 로고
    • The role of carotid artery intima-media thickness in predicating clinical coronary events
    • H. N. Hobis, W. J. Mack, et al., "The role of carotid artery intima-media thickness in predicating clinical coronary events," Ann. Intern. Med., vol. 128, pp. 262-269, 1998.
    • (1998) Ann. Intern. Med. , vol.128 , pp. 262-269
    • Hobis, H.N.1    Mack, W.J.2
  • 3
    • 0028100923 scopus 로고
    • Common carotid intima-media thickness measurement: A method to improve accuracy and precision
    • D. Baldassarre, et al., "Common carotid intima-media thickness measurement: A method to improve accuracy and precision," Stroke, vol. 25, pp. 1588-1592, 1994.
    • (1994) Stroke , vol.25 , pp. 1588-1592
    • Baldassarre, D.1
  • 4
    • 0027446488 scopus 로고
    • Isolated systolic hypertension and vessel wall thickness of the carotid artery: The Rotterdam Elderly Study
    • M. L Bots, et al., "Isolated systolic hypertension and vessel wall thickness of the carotid artery: the Rotterdam Elderly Study," Arterioscler. Thromb., vol. 13, pp. 64-69, 1993.
    • (1993) Arterioscler. Thromb. , vol.13 , pp. 64-69
    • Bots, M.L.1
  • 5
    • 0030056786 scopus 로고    scopus 로고
    • Progression of atherosclerosis in middle-aged men: Effects of multifactorial intervention
    • J. Persson, et al., "Progression of atherosclerosis in middle-aged men: effects of multifactorial intervention," J. Intern. Med., vol. 239, pp. 425-433, 1996.
    • (1996) J. Intern. Med. , vol.239 , pp. 425-433
    • Persson, J.1
  • 6
    • 0030710511 scopus 로고    scopus 로고
    • A new automated computerized analyzing system simplifies readings and reduces the variability in ultrasound measurement of intima-media thickness
    • I. Wendelhag, et al., "A new automated computerized analyzing system simplifies readings and reduces the variability in ultrasound measurement of intima-media thickness," Stroke, vol. 28, pp. 2195-2200, 1997.
    • (1997) Stroke , vol.28 , pp. 2195-2200
    • Wendelhag, I.1
  • 9
    • 0027693887 scopus 로고
    • Finite element methods for active contour methods and balloons for 2D and 3D images
    • L. D. Cohen, I. Cohen, "Finite element methods for active contour methods and balloons for 2D and 3D images," IEEE Trans. Pattern Analysis and Machine Intelligence, vol. 15, no. 11, pp. 1131-1147, 1993.
    • (1993) IEEE Trans. Pattern Analysis and Machine Intelligence , vol.15 , Issue.11 , pp. 1131-1147
    • Cohen, L.D.1    Cohen, I.2
  • 12
    • 0033080539 scopus 로고    scopus 로고
    • A contour detection method: Initialization and contour model
    • P. C. Yuen, G. C. Feng, and J. P. Zhou, "A contour detection method: Initialization and contour model," Pattern Recognition Letters, vol. 20, pp. 141-148, 1999.
    • (1999) Pattern Recognition Letters , vol.20 , pp. 141-148
    • Yuen, P.C.1    Feng, G.C.2    Zhou, J.P.3
  • 13
    • 0027608460 scopus 로고
    • Tracking deformable objects in the plane using an active contour model
    • F. Leymarie and M. D. Levine, "Tracking deformable objects in the plane using an active contour model," IEEE Trans. Patt. Anal. Machine Intell., vol. 15, no. 6, pp. 617-634, 1993.
    • (1993) IEEE Trans. Patt. Anal. Machine Intell. , vol.15 , Issue.6 , pp. 617-634
    • Leymarie, F.1    Levine, M.D.2
  • 14
    • 0030153642 scopus 로고    scopus 로고
    • Deformable models in medical image analysis: A survey
    • T. McInerney and D. Terzopoulos, "Deformable models in medical image analysis: a survey," Medical Image Analysis, vol. 1, no. 2, pp. 91-108, 1996.
    • (1996) Medical Image Analysis , vol.1 , Issue.2 , pp. 91-108
    • McInerney, T.1    Terzopoulos, D.2
  • 15
    • 0028518095 scopus 로고
    • Region-based strategies for active contour models
    • R. Ronfard, "Region-based strategies for active contour models," Int'l J. Computer Vision, vol. 13, no. 2, pp. 229-251, 1994.
    • (1994) Int'l J. Computer Vision , vol.13 , Issue.2 , pp. 229-251
    • Ronfard, R.1
  • 16
    • 0029326387 scopus 로고
    • Active region models for segmenting textures and colours
    • J. Ivins and J. Porrill, "Active region models for segmenting textures and colours," Image and Vision Computing, vol. 13, no. 5, pp. 431-438, 1994.
    • (1994) Image and Vision Computing , vol.13 , Issue.5 , pp. 431-438
    • Ivins, J.1    Porrill, J.2
  • 17
    • 0001029001 scopus 로고
    • Comments on techniques for edge detection
    • I. D. G. Macload, "Comments on techniques for edge detection," Proc. of IEEE, vol. 60, pp. 344, 1972.
    • (1972) Proc. of IEEE , vol.60 , pp. 344
    • Macload, I.D.G.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.