메뉴 건너뛰기




Volumn 39, Issue 1, 2014, Pages 62-68

Cirrus high-definition optical coherence tomography versus spectral optical coherence tomography/scanning laser ophthalmoscopy in the diagnosis of glaucoma

Author keywords

Glaucoma; Optical coherence tomography; Retinal nerve fiber layer; Scanning laser ophthalmoscopy; Spectral domain

Indexed keywords

ADULT; ARTICLE; CONTROLLED STUDY; DIAGNOSTIC TEST ACCURACY STUDY; FEMALE; GLAUCOMA; GOLDMANN APPLANATION TONOMETER; HUMAN; INTRAOCULAR PRESSURE; MAJOR CLINICAL STUDY; MALE; OPTICAL COHERENCE TOMOGRAPHY; PREDICTIVE VALUE; PRIORITY JOURNAL; REFRACTION ERROR; RETINA NERVE CELL; RETINAL THICKNESS; SCANNING LASER OPHTHALMOSCOPY; SPECTRAL OPTICAL COHERENCE TOMOGRAPHY; VISUAL ACUITY; VISUAL FIELD;

EID: 84890377459     PISSN: 02713683     EISSN: 14602202     Source Type: Journal    
DOI: 10.3109/02713683.2013.824989     Document Type: Article
Times cited : (6)

References (22)
  • 1
    • 67649336413 scopus 로고    scopus 로고
    • Retinal nerve fiber layer imaging with spectraldomain optical coherence tomography: A variability and diagnostic performance study
    • Leung CK, Cheung CY, Weinreb RN, Qiu Q, Liu S, Li H, et al. Retinal nerve fiber layer imaging with spectraldomain optical coherence tomography: A variability and diagnostic performance study. Ophthalmology 2009;116: 1257-1263
    • (2009) Ophthalmology , vol.116 , pp. 1257-1263
    • Leung, C.K.1    Cheung, C.Y.2    Weinreb, R.N.3    Qiu, Q.4    Liu, S.5    Li, H.6
  • 2
    • 73349089982 scopus 로고    scopus 로고
    • Comparison of glaucoma diagnostic Capabilities of Cirrus HD and Stratus optical coherence tomography
    • Park SB, Sung KR, Kang SY, Kim KR, Kook MS. Comparison of glaucoma diagnostic Capabilities of Cirrus HD and Stratus optical coherence tomography. Arch Ophthalmol 2009;127:1603-1609
    • (2009) Arch Ophthalmol , vol.127 , pp. 1603-1609
    • Park, S.B.1    Sung, K.R.2    Kang, S.Y.3    Kim, K.R.4    Kook, M.S.5
  • 3
    • 77956990790 scopus 로고    scopus 로고
    • Spectral-domain optical coherence tomography for detection of localized retinal nerve fiber layer defects in patients with open-Angle glaucoma
    • Kim NR, Lee ES, Seong GJ, Choi EH, Hong S, Kim CY. Spectral-domain optical coherence tomography for detection of localized retinal nerve fiber layer defects in patients with open-Angle glaucoma. Arch Ophthalmol 2010;128: 1121-1128
    • (2010) Arch Ophthalmol , vol.128 , pp. 1121-1128
    • Kim, N.R.1    Lee, E.S.2    Seong, G.J.3    Choi, E.H.4    Hong, S.5    Kim, C.Y.6
  • 4
    • 79960007954 scopus 로고    scopus 로고
    • Comparison of the diagnostic accuracies of the Spectralis, Cirrus, and RTVue optical coherence tomography devices in glaucoma
    • Leite MT, Rao HL, Zangwill LM, Weinreb RN, Medeiros FA. Comparison of the diagnostic accuracies of the Spectralis, Cirrus, and RTVue optical coherence tomography devices in glaucoma. Ophthalmology 2011; 118:1334-1339
    • (2011) Ophthalmology , vol.118 , pp. 1334-1339
    • Leite, M.T.1    Rao, H.L.2    Zangwill, L.M.3    Weinreb, R.N.4    Medeiros, F.A.5
  • 5
    • 80155199669 scopus 로고    scopus 로고
    • Ability of spectral domain optical coherence tomography peripapillary retinal nerve fiber layer thickness measurements to identify early glaucoma
    • Mansoori T, Viswanath K, Balakrishna N. Ability of spectral domain optical coherence tomography peripapillary retinal nerve fiber layer thickness measurements to identify early glaucoma. Indian J Ophthalmol 2011;59: 455-459
    • (2011) Indian J Ophthalmol , vol.59 , pp. 455-459
    • Mansoori, T.1    Viswanath, K.2    Balakrishna, N.3
  • 6
    • 78651456275 scopus 로고    scopus 로고
    • Detection of glaucoma by spectral domain-scanning laser ophthalmoscopy/optical coherence tomography (SD-SLO/OCT) and time domain optical coherence tomography
    • Cho JW, Sung KR, Hong JT, Um TW, Kang SY, Kook MS. Detection of glaucoma by spectral domain-scanning laser ophthalmoscopy/optical coherence tomography (SD-SLO/OCT) and time domain optical coherence tomography. J Glaucoma 2011;20:15-20
    • (2011) J Glaucoma , vol.20 , pp. 15-20
    • Cho, J.W.1    Sung, K.R.2    Hong, J.T.3    Um, T.W.4    Kang, S.Y.5    Kook, M.S.6
  • 7
    • 78650449208 scopus 로고    scopus 로고
    • Reproducibility of retinal nerve fiber thickness measurements using the test-retest function of spectral OCT/SLO in normal and glaucomatous eyes
    • Lee SH, Kim SH, Kim TW, Park KH, Kim DM. Reproducibility of retinal nerve fiber thickness measurements using the test-retest function of spectral OCT/SLO in normal and glaucomatous eyes. J Glaucoma 2010;19: 637-642
    • (2010) J Glaucoma , vol.19 , pp. 637-642
    • Lee, S.H.1    Kim, S.H.2    Kim, T.W.3    Park, K.H.4    Kim, D.M.5
  • 8
    • 79955041501 scopus 로고    scopus 로고
    • Reproducibility of peripapillary retinal nerve fibre layer thickness measurements with spectral domain optical coherence tomography in normal and glaucomatous eyes
    • Mansoori T, Viswanath K, Balakrishna N. Reproducibility of peripapillary retinal nerve fibre layer thickness measurements with spectral domain optical coherence tomography in normal and glaucomatous eyes. Br J Ophthalmol 2011;95:685-688
    • (2011) Br J Ophthalmol , vol.95 , pp. 685-688
    • Mansoori, T.1    Viswanath, K.2    Balakrishna, N.3
  • 9
    • 84871708678 scopus 로고    scopus 로고
    • Retinal nerve fiber layer thickness reproducibility using seven different OCT instruments
    • Pierro L, Gagliardi M, Iuliano L, Ambrosi A, Bandello F. Retinal nerve fiber layer thickness reproducibility using seven different OCT instruments. Invest Ophthalmol Vis Sci 2012;53:5912-5920
    • (2012) Invest Ophthalmol Vis Sci , vol.53 , pp. 5912-5920
    • Pierro, L.1    Gagliardi, M.2    Iuliano, L.3    Ambrosi, A.4    Bandello, F.5
  • 10
    • 78650509862 scopus 로고    scopus 로고
    • Agreement among spectral-domain optical coherence tomography instruments for assessing retinal nerve fiber layer thickness
    • e1
    • Leite MT, Rao HL, Weinreb RN, Zangwill LM, Bowd C, Sample PA, et al. Agreement among spectral-domain optical coherence tomography instruments for assessing retinal nerve fiber layer thickness. Am J Ophthalmol 2011; 151:85-92.e1
    • (2011) Am J Ophthalmol , vol.151 , pp. 85-92
    • Leite, M.T.1    Rao, H.L.2    Weinreb, R.N.3    Zangwill, L.M.4    Bowd, C.5    Sample, P.A.6
  • 11
    • 77956016924 scopus 로고    scopus 로고
    • Retinal nerve fiber layer thickness measurement by Fourier-domain optical coherence tomography: A comparison between cirrus-HD OCT and RTVue in healthy eyes
    • Savini G, Carbonelli M, Barboni P. Retinal nerve fiber layer thickness measurement by Fourier-domain optical coherence tomography: A comparison between cirrus-HD OCT and RTVue in healthy eyes. J Glaucoma 2010;19: 369-372
    • (2010) J Glaucoma , vol.19 , pp. 369-372
    • Savini, G.1    Carbonelli, M.2    Barboni, P.3
  • 12
    • 84861336358 scopus 로고    scopus 로고
    • Agreement among three types of spectral-domain optical coherent tomography instruments in measuring parapapillary retinal nerve fibre layer thickness
    • Kanamori A, Nakamura M, Tomioka M, Kawaka Y, Yamada Y, Negi A. Agreement among three types of spectral-domain optical coherent tomography instruments in measuring parapapillary retinal nerve fibre layer thickness. Br J Ophthalmol 2012;96:832-837
    • (2012) Br J Ophthalmol , vol.96 , pp. 832-837
    • Kanamori, A.1    Nakamura, M.2    Tomioka, M.3    Kawaka, Y.4    Yamada, Y.5    Negi, A.6
  • 13
    • 84865849715 scopus 로고    scopus 로고
    • Comparison of retinal nerve fiber layer thickness measurement bias and imprecision across three spectral-domain optical coherence tomography devices
    • Buchser NM,Wollstein G, Ishikawa H, Bilonick RA, Ling Y, Folio LS, et al. Comparison of retinal nerve fiber layer thickness measurement bias and imprecision across three spectral-domain optical coherence tomography devices. Invest Ophthalmol Vis Sci 2012;53:3742-3747
    • (2012) Invest Ophthalmol Vis Sci , vol.53 , pp. 3742-3747
    • Buchser, N.M.1    Wollstein, G.2    Ishikawa, H.3    Bilonick, R.A.4    Ling, Y.5    Folio, L.S.6
  • 15
    • 77957580748 scopus 로고    scopus 로고
    • Quantitative assessment of diffuse retinal nerve fiber layer atrophy using optical coherence tomography: Diffuse atrophy imaging study
    • Jeoung JW, Kim SH, Park KH, Kim TW, Kim DM. Quantitative assessment of diffuse retinal nerve fiber layer atrophy using optical coherence tomography: Diffuse atrophy imaging study. Ophthalmology 2010;117: 1946-1952
    • (2010) Ophthalmology , vol.117 , pp. 1946-1952
    • Jeoung, J.W.1    Kim, S.H.2    Park, K.H.3    Kim, T.W.4    Kim, D.M.5
  • 17
    • 4243500233 scopus 로고    scopus 로고
    • Available From [last accessed 6 March
    • Tape TG. Interpreting diagnostic tests. Available from: Http://gim.unmc.edu/dxtests/Default.htm [last accessed 6 March 2013].
    • (2013) Interpreting Diagnostic Tests
    • Tape, T.G.1
  • 18
    • 0020524559 scopus 로고
    • A method of comparing the areas under receiver operating characteristic curves derived from the same cases
    • Hanley JA, McNeil BJ. A method of comparing the areas under receiver operating characteristic curves derived from the same cases. Radiology 1983;148:839-843
    • (1983) Radiology , vol.148 , pp. 839-843
    • Hanley, J.A.1    McNeil, B.J.2
  • 19
    • 61349169568 scopus 로고    scopus 로고
    • Nasal retinal nerve fiber layer attenuation: A biomarker for vigabatrin toxicity
    • Lawthom C, Smith PE, Wild JM. Nasal retinal nerve fiber layer attenuation: A biomarker for vigabatrin toxicity. Ophthalmology 2009;116:565-571
    • (2009) Ophthalmology , vol.116 , pp. 565-571
    • Lawthom, C.1    Smith, P.E.2    Wild, J.M.3
  • 20
    • 84867746083 scopus 로고    scopus 로고
    • Better performance of RTVue than Cirrus spectral-domain optical coherence tomography in detecting band atrophy of the optic nerve
    • Nakamura M, Ishikawa-Tabuchi K, Kanamori A, Yamada Y, Negi A. Better performance of RTVue than Cirrus spectral-domain optical coherence tomography in detecting band atrophy of the optic nerve. Graefes Arch Clin Exp Ophthalmol 2012;250:1499-1507
    • (2012) Graefes Arch Clin Exp Ophthalmol , vol.250 , pp. 1499-1507
    • Nakamura, M.1    Ishikawa-Tabuchi, K.2    Kanamori, A.3    Yamada, Y.4    Negi, A.5
  • 21
    • 84879800253 scopus 로고    scopus 로고
    • Ability of Cirrus High-Definition Spectral-domain optical coherence tomography clock-Hour, deviation, and thickness maps in detecting photographic retinal nerve fiber layer abnormalities
    • Hwang YH, Kim YY, Kim HK, Sohn YH. Ability of Cirrus High-Definition Spectral-domain optical coherence tomography clock-Hour, deviation, and thickness maps in detecting photographic retinal nerve fiber layer abnormalities. Ophthalmology 2013;120:1380-1387
    • (2013) Ophthalmology , vol.120 , pp. 1380-1387
    • Hwang, Y.H.1    Kim, Y.Y.2    Kim, H.K.3    Sohn, Y.H.4
  • 22
    • 84865685166 scopus 로고    scopus 로고
    • Retinal nerve fiber layer imaging with spectraldomain optical coherence tomography: Patterns of retinal nerve fiber layer progression
    • Leung CK, Yu M, Weinreb RN, Lai G, Xu G, Lam DS. Retinal nerve fiber layer imaging with spectraldomain optical coherence tomography: Patterns of retinal nerve fiber layer progression. Ophthalmology 2012;119: 1858-1866
    • (2012) Ophthalmology , vol.119 , pp. 1858-1866
    • Leung, C.K.1    Yu, M.2    Weinreb, R.N.3    Lai, G.4    Xu, G.5    Lam, D.S.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.