메뉴 건너뛰기




Volumn 42, Issue 6, 2013, Pages 1586-1594

Zero reference level for right heart catheterisation

Author keywords

[No Author keywords available]

Indexed keywords

1/3 THORACIC DIAMETER BELOW ANTERIOR THORAX SURFACE; 10 CM ABOVE TABLE LEVEL; 5 CM BELOW ANTERIOR THORAX SURFACE; ADULT; ARTICLE; BODY MASS; COMPARATIVE STUDY; COMPUTED TOMOGRAPHY SCANNER; COMPUTER ASSISTED TOMOGRAPHY; CONTROLLED STUDY; DISEASE CLASSIFICATION; FEMALE; HEART CATHETERIZATION; HEART LEFT ATRIUM; HEART RIGHT ATRIUM; HUMAN; LUNG ARTERY PRESSURE; LUNG WEDGE PRESSURE; MAJOR CLINICAL STUDY; MALE; MID THORACIC LEVEL; MIDDLE AGED; PATIENT CODING; PRIORITY JOURNAL; PULMONARY HYPERTENSION; REFERENCE VALUE; RETROSPECTIVE STUDY; ZERO REFERENCE LEVEL;

EID: 84890092196     PISSN: 09031936     EISSN: 13993003     Source Type: Journal    
DOI: 10.1183/09031936.00050713     Document Type: Article
Times cited : (112)

References (34)
  • 1
    • 70349634397 scopus 로고    scopus 로고
    • Guidelines for the diagnosis and treatment of pulmonary hypertension
    • Galie N, Hoeper MM, Humbert M, et al. Guidelines for the diagnosis and treatment of pulmonary hypertension. Eur Respir J 2009; 34: 1219-1263.
    • (2009) Eur Respir J , vol.34 , pp. 1219-1263
    • Galie, N.1    Hoeper, M.M.2    Humbert, M.3
  • 2
    • 0030965778 scopus 로고    scopus 로고
    • Pulmonary Artery Catheter Consensus conference: Consensus statement
    • Pulmonary Artery Catheter Consensus conference: consensus statement. Crit Care Med 1997; 25: 910-925.
    • (1997) Crit Care Med , vol.25 , pp. 910-925
  • 3
    • 0001626516 scopus 로고
    • Dynamics of the pulmonary circulation
    • Hamilton W, Dow P, eds. Washington, American Physiological Society
    • Fishman A. Dynamics of the Pulmonary Circulation. In: Hamilton W, Dow P, eds. Handbook of Physiology. Washington, American Physiological Society, 1963; pp. 1667-1743.
    • (1963) Handbook of Physiology , pp. 1667-1743
    • Fishman, A.1
  • 5
    • 0003121525 scopus 로고    scopus 로고
    • Vascular distensibility and functions of the arterial and venous systems
    • Guyton AC, Hall JE, eds. 11th Edn. Oxford, Elsevier
    • Guyton AC, Hall JE. Vascular Distensibility and Functions of the Arterial and Venous Systems. In: Guyton AC, Hall JE, eds. Textbook of Medical Physiology. 11th Edn. Oxford, Elsevier, 2005; pp. 171-180.
    • (2005) Textbook of Medical Physiology , pp. 171-180
    • Guyton, A.C.1    Hall, J.E.2
  • 6
    • 0040008112 scopus 로고
    • Über eine Methode, beim Menschen den Druck in oberflächlichen Venen exakt zu bestimmen
    • Moritz F, von Tabora D. Über eine Methode, beim Menschen den Druck in oberflächlichen Venen exakt zu bestimmen [A method for determining exact superficial venous pressure in humans]. Deutsches Archiv für klinische Medizin 1910; 98: 475-505.
    • (1910) Deutsches Archiv für Klinische Medizin , vol.98 , pp. 475-505
    • Moritz, F.1    Von Tabora, D.2
  • 9
    • 33646346224 scopus 로고
    • The measurement of venous pressure by the direct method
    • Lyons R, Kennedy A, Burwell S. The measurement of venous pressure by the direct method. Am Heart J 1938; 16: 675-693.
    • (1938) Am Heart J , vol.16 , pp. 675-693
    • Lyons, R.1    Kennedy, A.2    Burwell, S.3
  • 10
    • 76949125525 scopus 로고
    • Venous pressure measurement
    • Pederson A, Husby J. Venous pressure measurement. Acta Med Scand 1951; 141: 185-194.
    • (1951) Acta Med Scand , vol.141 , pp. 185-194
    • Pederson, A.1    Husby, J.2
  • 11
    • 84944484541 scopus 로고
    • The influence of the force of gravity on the circulation of the blood
    • Hill L. The influence of the force of gravity on the circulation of the blood. J Physiol 1895; 18: 15-53.
    • (1895) J Physiol , vol.18 , pp. 15-53
    • Hill, L.1
  • 12
    • 0011690147 scopus 로고
    • A physiologic reference point for measuring circulatory pressures in the dog; Particularly venous pressure
    • Guyton AC, Greganti FP. A physiologic reference point for measuring circulatory pressures in the dog; particularly venous pressure. Am J Physiol 1956; 185: 137-141.
    • (1956) Am J Physiol , vol.185 , pp. 137-141
    • Guyton, A.C.1    Greganti, F.P.2
  • 13
    • 0031847440 scopus 로고    scopus 로고
    • Physical examination of venous pressure: A critical review
    • McGee SR. Physical examination of venous pressure: a critical review. Am Heart J 1998; 136: 10-18.
    • (1998) Am Heart J , vol.136 , pp. 10-18
    • McGee, S.R.1
  • 14
    • 0001238792 scopus 로고
    • Phlebostatic axis and phlebostatic level: Reference levels for venous pressure measurements in man
    • Winsor T, Burch G. Phlebostatic axis and phlebostatic level: reference levels for venous pressure measurements in man. Proc Soc Exp Biol Med 1945; 58: 165-169.
    • (1945) Proc Soc Exp Biol Med , vol.58 , pp. 165-169
    • Winsor, T.1    Burch, G.2
  • 15
    • 0040601428 scopus 로고
    • Über die Bedeutung der Venendruckmessung bei der diätetisch-physikalischen Behandlung der Kreislaufstörungen
    • Frey A. Über die Bedeutung der Venendruckmessung bei der diätetisch-physikalischen Behandlung der Kreislaufstörungen [The relevance of venous pressure measurement at the dietary and physical treatment of circulatory disorders]. Deutsches Archiv für klinische Medizin 1902; 73: 511-545.
    • (1902) Deutsches Archiv für Klinische Medizin , vol.73 , pp. 511-545
    • Frey, A.1
  • 16
    • 0027352991 scopus 로고
    • Echocardiographic determination of valid zero reference levels in supine and lateral positions
    • Kee LL, Simonson JS, Stotts NA, et al. Echocardiographic determination of valid zero reference levels in supine and lateral positions. Am J Crit Care 1993; 2: 72-80.
    • (1993) Am J Crit Care , vol.2 , pp. 72-80
    • Kee, L.L.1    Simonson, J.S.2    Stotts, N.A.3
  • 17
    • 33646368243 scopus 로고
    • The measurement of venous pressure in man eliminating the hydrostatic factor
    • Holt JP. The measurement of venous pressure in man eliminating the hydrostatic factor. Am J Physiol 1940; 130: 635-641.
    • (1940) Am J Physiol , vol.130 , pp. 635-641
    • Holt, J.P.1
  • 18
    • 0023790972 scopus 로고
    • Topographic location of the left atrium by computed tomography: Reducing pulmonary artery catheter calibration error
    • Paolella LP, Dorfman GS, Cronan JJ, et al. Topographic location of the left atrium by computed tomography: reducing pulmonary artery catheter calibration error. Crit Care Med 1988; 16: 1154-1156.
    • (1988) Crit Care Med , vol.16 , pp. 1154-1156
    • Paolella, L.P.1    Dorfman, G.S.2    Cronan, J.J.3
  • 19
    • 34547581063 scopus 로고    scopus 로고
    • Uppermost blood levels of the right and left atria in the supine position: Implication for measuring central venous pressure and pulmonary artery wedge pressure
    • Seo JH, Jung CW, Bahk JH. Uppermost blood levels of the right and left atria in the supine position: implication for measuring central venous pressure and pulmonary artery wedge pressure. Anesthesiology 2007; 107: 260-263.
    • (2007) Anesthesiology , vol.107 , pp. 260-263
    • Seo, J.H.1    Jung, C.W.2    Bahk, J.H.3
  • 20
    • 0014684140 scopus 로고
    • "Normal central venous pressure," significance of reference point and normal range
    • Debrunner F, Buhler F. "Normal central venous pressure," significance of reference point and normal range. Br Med J 1969; 3: 148-150.
    • (1969) Br Med J , vol.3 , pp. 148-150
    • Debrunner, F.1    Buhler, F.2
  • 21
    • 84890032601 scopus 로고
    • Pressure in the right auricle of man, in normal subjects and in patients with congestive heart failure
    • Richards DWJ, Cournand A, Darling RC, et al. Pressure in the right auricle of man, in normal subjects and in patients with congestive heart failure. Tr A Am Physicians 1941; 56: 218-221.
    • (1941) Tr A Am Physicians , vol.56 , pp. 218-221
    • Richards, D.W.J.1    Cournand, A.2    Darling, R.C.3
  • 22
    • 84890076112 scopus 로고
    • Intravenous pressure: I. New method of determination
    • Brams W, Katz L, Schutz W. Intravenous Pressure: I. New Method of Determination. Arch Intern Med 1933; 51: 33-37.
    • (1933) Arch Intern Med , vol.51 , pp. 33-37
    • Brams, W.1    Katz, L.2    Schutz, W.3
  • 23
    • 0032162063 scopus 로고    scopus 로고
    • Present use of bedside right heart catherization in patients with cardiac disease
    • Mueller HS, Chatterjee K, Davis BK, et al. Present use of bedside right heart catherization in patients with cardiac disease. J Am Coll Cardiol 1998; 32: 840-864.
    • (1998) J Am Coll Cardiol , vol.32 , pp. 840-864
    • Mueller, H.S.1    Chatterjee, K.2    Davis, B.K.3
  • 24
    • 84890050221 scopus 로고
    • A study of the venous blood pressure in some common diseases
    • Wartmann WB. A study of the venous blood pressure in some common diseases. Am J Med Sci 1935: 464-477.
    • (1935) Am J Med Sci , pp. 464-477
    • Wartmann, W.B.1
  • 25
    • 84890060217 scopus 로고
    • Venous pressure
    • Evans W. Venous pressure. N Engl J Med 1932; 207: 934-940.
    • (1932) N Engl J Med , vol.207 , pp. 934-940
    • Evans, W.1
  • 26
    • 0040601430 scopus 로고
    • Die Messung des Drucks im rechten Vorhof
    • Gaertner G. Die Messung des Drucks im rechten Vorhof [Measurement of right atrial pressure]. Münchener medizinische Wochenschrift 1903; 50: 2038-2041.
    • (1903) Münchener Medizinische Wochenschrift , vol.50 , pp. 2038-2041
    • Gaertner, G.1
  • 27
    • 33646366252 scopus 로고
    • Venous pressure in heart disease
    • Harris I. Venous pressure in heart disease. Edinburgh Med J 1928; 35: 630-650.
    • (1928) Edinburgh Med J , vol.35 , pp. 630-650
    • Harris, I.1
  • 28
    • 0016132266 scopus 로고
    • Locating the external reference point for central venous pressure determination
    • Drake JJ. Locating the external reference point for central venous pressure determination. Nurs Res 1974; 23: 475-482.
    • (1974) Nurs Res , vol.23 , pp. 475-482
    • Drake, J.J.1
  • 29
    • 0029100145 scopus 로고
    • Anatomically and physiologically based reference level for measurement of intracardiac pressures
    • Courtois M, Fattal PG, Kovacs SJ Jr, et al. Anatomically and physiologically based reference level for measurement of intracardiac pressures. Circulation 1995; 92: 1994-2000.
    • (1995) Circulation , vol.92 , pp. 1994-2000
    • Courtois, M.1    Fattal, P.G.2    Kovacs Jr., S.J.3
  • 30
    • 78651415646 scopus 로고    scopus 로고
    • The changing picture of patients with pulmonary arterial hypertension in the United States: How REVEAL differs from historic and non-US Contemporary Registries
    • Frost AE, Badesch DB, Barst RJ, et al. The changing picture of patients with pulmonary arterial hypertension in the United States: how REVEAL differs from historic and non-US Contemporary Registries. Chest 2011; 139: 128-137.
    • (2011) Chest , vol.139 , pp. 128-137
    • Frost, A.E.1    Badesch, D.B.2    Barst, R.J.3
  • 31
    • 0000249830 scopus 로고
    • Left atrial and left ventricular pressures in subjects without cardiovascular disease: Observations in eighteen patients studied by transseptal left heart catheterization
    • Braunwald E, Brockenbrough EC, Frahm CJ, et al. Left atrial and left ventricular pressures in subjects without cardiovascular disease: observations in eighteen patients studied by transseptal left heart catheterization. Circulation 1961; 24: 267-269.
    • (1961) Circulation , vol.24 , pp. 267-269
    • Braunwald, E.1    Brockenbrough, E.C.2    Frahm, C.J.3
  • 33
    • 0016441927 scopus 로고
    • Determination of zero reference level for left atrial pressure by echocardiography
    • Chandraratna PA. Determination of zero reference level for left atrial pressure by echocardiography. Am Heart J 1975; 89: 159-162.
    • (1975) Am Heart J , vol.89 , pp. 159-162
    • Chandraratna, P.A.1
  • 34
    • 84860142442 scopus 로고    scopus 로고
    • Current practice for determining pulmonary capillary wedge pressure predisposes to serious errors in the classification of patients with pulmonary hypertension
    • Ryan JJ, Rich JD, Thiruvoipati T, et al. Current practice for determining pulmonary capillary wedge pressure predisposes to serious errors in the classification of patients with pulmonary hypertension. Am Heart J 2012; 163: 589-594.
    • (2012) Am Heart J , vol.163 , pp. 589-594
    • Ryan, J.J.1    Rich, J.D.2    Thiruvoipati, T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.