메뉴 건너뛰기




Volumn 40, Issue 12, 2013, Pages

Four-dimensional monte carlo simulations demonstrating how the extent of intensity-modulation impacts motion effects in proton therapy lung treatments

Author keywords

[No Author keywords available]

Indexed keywords

BIOLOGICAL ORGANS; COMPUTERIZED TOMOGRAPHY; MODULATION; PATIENT MONITORING; PROTON BEAM THERAPY; PROTON BEAMS;

EID: 84890044123     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.4829500     Document Type: Article
Times cited : (16)

References (21)
  • 1
    • 0021054301 scopus 로고
    • Beam scanning for heavy charged particle radiotherapy
    • 10.1118/1.595419
    • M. Goitein and G. T. Y. Chen, " Beam scanning for heavy charged particle radiotherapy.," Med. Phys. 10 (6), 831-840 (1983). 10.1118/1.595419
    • (1983) Med. Phys. , vol.10 , Issue.6 , pp. 831-840
    • Goitein, M.1    Chen, G.T.Y.2
  • 2
    • 0035083293 scopus 로고    scopus 로고
    • Intensity modulated proton therapy: A clinical example
    • 10.1118/1.1350587
    • A. J. Lomax, " Intensity modulated proton therapy: A clinical example.," Med. Phys. 28 (3), 317-324 (2001). 10.1118/1.1350587
    • (2001) Med. Phys. , vol.28 , Issue.3 , pp. 317-324
    • Lomax, A.J.1
  • 3
    • 0037036516 scopus 로고    scopus 로고
    • Effects of intra-fraction motion on IMRT dose delivery: Statistical analysis and simulation
    • 10.1088/0031-9155/47/13/302
    • T. Bortfeld, K. Jokivarsi, M. Goitein, J. Kung, and S. B. Jiang, " Effects of intra-fraction motion on IMRT dose delivery: Statistical analysis and simulation.," Phys. Med. Biol. 47 (13), 2203-2220 (2002). 10.1088/0031-9155/47/13/302
    • (2002) Phys. Med. Biol. , vol.47 , Issue.13 , pp. 2203-2220
    • Bortfeld, T.1    Jokivarsi, K.2    Goitein, M.3    Kung, J.4    Jiang, S.B.5
  • 4
    • 84878882963 scopus 로고    scopus 로고
    • Interplay effects in proton scanning for lung: A 4D Monte Carlo study assessing the impact of tumor and beam delivery parameters
    • 10.1088/0031-9155/58/12/4137
    • S. Dowdell, C. Grassberger, G. C. Sharp, and H. Paganetti, " Interplay effects in proton scanning for lung: A 4D Monte Carlo study assessing the impact of tumor and beam delivery parameters.," Phys. Med. Biol. 58, 4137-4156 (2013). 10.1088/0031-9155/58/12/4137
    • (2013) Phys. Med. Biol. , vol.58 , pp. 4137-4156
    • Dowdell, S.1    Grassberger, C.2    Sharp, G.C.3    Paganetti, H.4
  • 5
    • 84877579543 scopus 로고    scopus 로고
    • Motion interplay as a function of patient parameters and spot size in spot scanning proton therapy for lung cancer
    • 10.1016/j.ijrob2013.01.024
    • C. Grassberger, " Motion interplay as a function of patient parameters and spot size in spot scanning proton therapy for lung cancer.," Int. J. Radiat. Oncol., Biol., Phys. 86 (2), 380-386 (2013). 10.1016/j.ijrobp.2013.01.024
    • (2013) Int. J. Radiat. Oncol., Biol., Phys. , vol.86 , Issue.2 , pp. 380-386
    • Grassberger, C.1
  • 6
    • 84863348495 scopus 로고    scopus 로고
    • Respiratory liver motion estimation and its effect on scanned proton beam therapy
    • 10.1088/0031-9155/57/7/1779
    • Y. Zhang, D. Boye, C. Tanner, A. J. Lomax, and A. Knopf, " Respiratory liver motion estimation and its effect on scanned proton beam therapy.," Phys. Med. Biol. 57 (7), 1779-1795 (2012). 10.1088/0031-9155/57/ 7/1779
    • (2012) Phys. Med. Biol. , vol.57 , Issue.7 , pp. 1779-1795
    • Zhang, Y.1    Boye, D.2    Tanner, C.3    Lomax, A.J.4    Knopf, A.5
  • 7
    • 70349581605 scopus 로고    scopus 로고
    • Breathing interplay effects during proton beam scanning: Simulation and statistical analysis
    • 10.1088/0031-9155/54/14/N01
    • J. Seco, D. Robertson, A. Trofimov, and H. Paganetti, " Breathing interplay effects during proton beam scanning: Simulation and statistical analysis.," Phys. Med. Biol. 54 (14), N283-N294 (2009). 10.1088/0031-9155/54/14/N01
    • (2009) Phys. Med. Biol. , vol.54 , Issue.14
    • Seco, J.1    Robertson, D.2    Trofimov, A.3    Paganetti, H.4
  • 8
    • 42449147956 scopus 로고    scopus 로고
    • Quantification of interplay effects of scanned particle beams and moving targets
    • 10.1088/0031-9155/53/9/003
    • C. Bert, S. O. Grözinger, and E. Rietzel, " Quantification of interplay effects of scanned particle beams and moving targets.," Phys. Med. Biol. 53 (9), 2253-2265 (2008). 10.1088/0031-9155/53/9/003
    • (2008) Phys. Med. Biol. , vol.53 , Issue.9 , pp. 2253-2265
    • Bert, C.1    Grözinger, S.O.2    Rietzel, E.3
  • 9
    • 61549092441 scopus 로고    scopus 로고
    • Gated Irradiation with Scanned Particle Beams
    • 10.1016/j.ijrob2008.11.014
    • C. Bert, A. Gemmel, N. Saito, and E. Rietzel, " Gated Irradiation With Scanned Particle Beams.," Int. J. Radiat. Oncol., Biol., Phys. 73 (4), 1270-1275 (2009). 10.1016/j.ijrobp.2008.11.014
    • (2009) Int. J. Radiat. Oncol., Biol., Phys. , vol.73 , Issue.4 , pp. 1270-1275
    • Bert, C.1    Gemmel, A.2    Saito, N.3    Rietzel, E.4
  • 10
    • 84867307246 scopus 로고    scopus 로고
    • Motion mitigation in intensity modulated particle therapy by internal target volumes covering range changes
    • 10.1118/1.4749964
    • C. Graeff, M. Durante, and C. Bert, " Motion mitigation in intensity modulated particle therapy by internal target volumes covering range changes.," Med. Phys. 39 (10), 6004-6013 (2012). 10.1118/1.4749964
    • (2012) Med. Phys. , vol.39 , Issue.10 , pp. 6004-6013
    • Graeff, C.1    Durante, M.2    Bert, C.3
  • 11
    • 73649128300 scopus 로고    scopus 로고
    • A case study in proton pencil-beam scanning delivery
    • 10.1016/j.ijrob2009.06.065
    • H. Kooy, " A case study in proton pencil-beam scanning delivery.," Int. J. Radiat. Oncol., Biol., Phys. 76 (2), 624-630 (2010). 10.1016/j.ijrobp.2009.06.065
    • (2010) Int. J. Radiat. Oncol., Biol., Phys. , vol.76 , Issue.2 , pp. 624-630
    • Kooy, H.1
  • 12
    • 33846809437 scopus 로고    scopus 로고
    • 4D Proton treatment planning strategy for mobile lung tumors
    • 10.1016/j.ijrob2006.10.045
    • Y. Kang, " 4D Proton treatment planning strategy for mobile lung tumors.," Int. J. Radiat. Oncol., Biol., Phys. 67 (3), 906-914 (2007). 10.1016/j.ijrobp.2006.10.045
    • (2007) Int. J. Radiat. Oncol., Biol., Phys. , vol.67 , Issue.3 , pp. 906-914
    • Kang, Y.1
  • 13
    • 77956320062 scopus 로고    scopus 로고
    • A fast optimization algorithm for multicriteria intensity modulated proton therapy planning
    • 10.1118/1.3481566
    • W. Chen, D. Craft, T. M. Madden, K. Zhang, H. M. Kooy, and G. T. Herman, " A fast optimization algorithm for multicriteria intensity modulated proton therapy planning.," Med. Phys. 37 (9), 4938-4945 (2010). 10.1118/1.3481566
    • (2010) Med. Phys. , vol.37 , Issue.9 , pp. 4938-4945
    • Chen, W.1    Craft, D.2    Madden, T.M.3    Zhang, K.4    Kooy, H.M.5    Herman, G.T.6
  • 14
    • 84868534543 scopus 로고    scopus 로고
    • TOPAS: An innovative proton Monte Carlo platform for research and clinical applications
    • 10.1118/1.4758060
    • J. Perl, J. Shin, J. Schümann, B. Faddegon, and H. Paganetti, " TOPAS: An innovative proton Monte Carlo platform for research and clinical applications.," Med. Phys. 39 (11), 6818-6837 (2012). 10.1118/1.4758060
    • (2012) Med. Phys. , vol.39 , Issue.11 , pp. 6818-6837
    • Perl, J.1    Shin, J.2    Schümann, J.3    Faddegon, B.4    Paganetti, H.5
  • 15
    • 84860361249 scopus 로고    scopus 로고
    • Monte Carlo study of the potential reduction in out-of-field dose using a patient-specific aperture in pencil beam scanning proton therapy
    • 10.1088/0031-9155/57/10/2829
    • S. Dowdell, " Monte Carlo study of the potential reduction in out-of-field dose using a patient-specific aperture in pencil beam scanning proton therapy.," Phys. Med. Biol. 57 (10), 2829-2842 (2012). 10.1088/0031-9155/57/10/2829
    • (2012) Phys. Med. Biol. , vol.57 , Issue.10 , pp. 2829-2842
    • Dowdell, S.1
  • 17
    • 0031037018 scopus 로고    scopus 로고
    • Reporting and analyzing dose distributions: A concept of equivalent uniform dose
    • 10.1118/1.598063
    • A. Niemierko, " Reporting and analyzing dose distributions: A concept of equivalent uniform dose.," Med. Phys. 24 (1), 103-110 (1997). 10.1118/1.598063
    • (1997) Med. Phys. , vol.24 , Issue.1 , pp. 103-110
    • Niemierko, A.1
  • 18
    • 80155130439 scopus 로고    scopus 로고
    • Scanned proton radiotherapy for mobile targets: The effectiveness of re-scanning in the context of different treatment planning approaches and for different motion characteristics
    • 10.1088/0031-9155/56/22/016
    • A.-C. Knopf, T. S. Hong, and A. Lomax, " Scanned proton radiotherapy for mobile targets: The effectiveness of re-scanning in the context of different treatment planning approaches and for different motion characteristics.," Phys. Med. Biol. 56 (22), 7257-7271 (2011). 10.1088/0031-9155/56/22/016
    • (2011) Phys. Med. Biol. , vol.56 , Issue.22 , pp. 7257-7271
    • Knopf, A.-C.1    Hong, T.S.2    Lomax, A.3
  • 19
    • 80053616275 scopus 로고    scopus 로고
    • Dosimetric consequences of tumour motion due to respiration for a scanned proton beam
    • 10.1088/0031-9155/56/20/003
    • K. M. Kraus, E. Heath, and U. Oelfke, " Dosimetric consequences of tumour motion due to respiration for a scanned proton beam.," Phys. Med. Biol. 56 (20), 6563-6581 (2011). 10.1088/0031-9155/56/20/003
    • (2011) Phys. Med. Biol. , vol.56 , Issue.20 , pp. 6563-6581
    • Kraus, K.M.1    Heath, E.2    Oelfke, U.3
  • 20
    • 84857833224 scopus 로고    scopus 로고
    • Is there a single spot size and grid for intensity modulated proton therapy? Simulation of head and neck, prostate and mesothelioma cases
    • 10.1118/1.3683640
    • L. Widesott, A. J. Lomax, and M. Schwarz, " Is there a single spot size and grid for intensity modulated proton therapy? Simulation of head and neck, prostate and mesothelioma cases.," Med. Phys. 39 (3), 1298-1308 (2012). 10.1118/1.3683640
    • (2012) Med. Phys. , vol.39 , Issue.3 , pp. 1298-1308
    • Widesott, L.1    Lomax, A.J.2    Schwarz, M.3
  • 21
    • 58149125638 scopus 로고    scopus 로고
    • Reducing the sensitivity of IMPT treatment plans to setup errors and range uncertainties via probabilistic treatment planning
    • 10.1118/1.3021139
    • J. Unkelbach, T. Bortfeld, B. C. Martin, and M. Soukup, " Reducing the sensitivity of IMPT treatment plans to setup errors and range uncertainties via probabilistic treatment planning.," Med. Phys. 36 (1), 149-163 (2009). 10.1118/1.3021139
    • (2009) Med. Phys. , vol.36 , Issue.1 , pp. 149-163
    • Unkelbach, J.1    Bortfeld, T.2    Martin, B.C.3    Soukup, M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.