메뉴 건너뛰기




Volumn 3, Issue , 2008, Pages 1343-1358

Early Detection of Lung Cancer: Metabolic Profiling of Human Breath with Ion Mobility Spectrometers

Author keywords

Amoxilin; Enterobacter aerogenes; Matogram; Spectrometers; Volatile

Indexed keywords


EID: 84889956546     PISSN: None     EISSN: None     Source Type: Book    
DOI: 10.1002/9783527620982.ch55     Document Type: Chapter
Times cited : (10)

References (38)
  • 1
    • 0031149661 scopus 로고    scopus 로고
    • Method for the collection and assay of volatile organic compounds in breath
    • Phillips, M. Method for the collection and assay of volatile organic compounds in breath. Anal. Biochem. 247, 272-278, 1997.
    • (1997) Anal. Biochem. , vol.247 , pp. 272-278
    • Phillips, M.1
  • 2
    • 0033526615 scopus 로고    scopus 로고
    • Volatile organic compounds in breath as markers of lung cancer: a cross-sectional study
    • Phillips, M., Gleeson, K., Hughes, J. M., Greenberg, J., Cataneo, R. N., Baker, L., McVay, W.P. Volatile organic compounds in breath as markers of lung cancer: a cross-sectional study. Lancet 353, 1930-1933, 1999.
    • (1999) Lancet , vol.353 , pp. 1930-1933
    • Phillips, M.1    Gleeson, K.2    Hughes, J.M.3    Greenberg, J.4    Cataneo, R.N.5    Baker, L.6    McVay, W.P.7
  • 3
    • 0026605510 scopus 로고
    • Ion trap detection of volatile organic compounds in alveolar breath
    • Phillips, M., Greenberg, J. Ion trap detection of volatile organic compounds in alveolar breath. Clin. Chem. 38, 60-65, 1992.
    • (1992) Clin. Chem. , vol.38 , pp. 60-65
    • Phillips, M.1    Greenberg, J.2
  • 4
    • 0014022301 scopus 로고
    • Acetone in alveolar air, and the control of diabetes
    • Rooth, G., Lund, M.D., Östenson, S. Acetone in alveolar air, and the control of diabetes. Lancet 1102-1104, 1966.
    • (1966) Lancet , pp. 1102-1104
    • Rooth, G.1    Lund, M.D.2    Östenson, S.3
  • 5
    • 0020740091 scopus 로고
    • Breath analysis by atmospheric pressure ionization mass spectrometry
    • Benolt, M.F., Davidson, W. R., Lovett, A. M., Nacson, S., Ngo, A. Breath analysis by atmospheric pressure ionization mass spectrometry. Anal. Chem. 55, 805-807, 1983.
    • (1983) Anal. Chem. , vol.55 , pp. 805-807
    • Benolt, M.F.1    Davidson, W.R.2    Lovett, A.M.3    Nacson, S.4    Ngo, A.5
  • 6
    • 0033105465 scopus 로고    scopus 로고
    • Technology development in breath microanalysis for clinical diagnosis
    • Cheng, W.-H., Lee, W.-J. Technology development in breath microanalysis for clinical diagnosis. J. Lab. Clin. Med. 133, 218-228, 1999.
    • (1999) J. Lab. Clin. Med. , vol.133 , pp. 218-228
    • Cheng, W.-H.1    Lee, W.-J.2
  • 8
    • 0031568680 scopus 로고    scopus 로고
    • Solid-phase microextraction for the analysis of human breath
    • Grote, C., Pawliszyn, J. Solid-phase microextraction for the analysis of human breath. Anal. Chem. 69, 587-596, 1997.
    • (1997) Anal. Chem. , vol.69 , pp. 587-596
    • Grote, C.1    Pawliszyn, J.2
  • 9
    • 26744446019 scopus 로고
    • Proton transfer reaction mass spectrometry: on-line trace gas analysis at the ppb level.
    • Hansel, A., Jordan, A., Holzinger, R. Proton transfer reaction mass spectrometry: on-line trace gas analysis at the ppb level. Int. J. Mass Spectrom. Ion Proc. 149, 609-619, 1995.
    • (1995) Int. J. Mass Spectrom. Ion Proc. , vol.149 , pp. 609-619
    • Hansel, A.1    Jordan, A.2    Holzinger, R.3
  • 10
    • 0014633582 scopus 로고
    • Analysis of organic compounds in human breath by gas chromatography mass spectrometry
    • Jansson, B. O., Larsson, B.T. Analysis of organic compounds in human breath by gas chromatography mass spectrometry. J. Lab. Clin. Med. 74, 961-966, 1969.
    • (1969) J. Lab. Clin. Med. , vol.74 , pp. 961-966
    • Jansson, B.O.1    Larsson, B.T.2
  • 11
    • 10044271359 scopus 로고    scopus 로고
    • On-line monitoring of volatile organic compounds at pptv levels by means of proton-transfer-reaction mass spectrometry (PTR-MS) medical applications, food control and environmental research
    • Lindinger, W., Hansel, A., Jordan, A. On-line monitoring of volatile organic compounds at pptv levels by means of proton-transfer-reaction mass spectrometry (PTR-MS) medical applications, food control and environmental research. Int. J. Mass Spectrom. Ion Proc. 173, 191-241, 1998.
    • (1998) Int. J. Mass Spectrom. Ion Proc. , vol.173 , pp. 191-241
    • Lindinger, W.1    Hansel, A.2    Jordan, A.3
  • 12
    • 0020693943 scopus 로고
    • The diagnostic potential of breath analysis
    • Manolis, A. The diagnostic potential of breath analysis. Clin. Chem. 29, 5-15, 1983.
    • (1983) Clin. Chem. , vol.29 , pp. 5-15
    • Manolis, A.1
  • 14
    • 0029958818 scopus 로고    scopus 로고
    • A simple, reliable method for the determination of chlorinated volatile organics in human breath and air using glass sampling tubes
    • Stein, V. B., Narang, R. S., Wilson, L., Aldous, K.M. A simple, reliable method for the determination of chlorinated volatile organics in human breath and air using glass sampling tubes. J. Anal. Toxicol. 20, 145-150, 1996.
    • (1996) J. Anal. Toxicol. , vol.20 , pp. 145-150
    • Stein, V.B.1    Narang, R.S.2    Wilson, L.3    Aldous, K.M.4
  • 15
    • 0030939301 scopus 로고    scopus 로고
    • Exhaled human breath measurement method for assessing exposure to halogenated volatile organic compounds
    • Pleil, J. D., Lindstrom, A.B. Exhaled human breath measurement method for assessing exposure to halogenated volatile organic compounds. Clin. Chem. 43, 723-730, 1997.
    • (1997) Clin. Chem. , vol.43 , pp. 723-730
    • Pleil, J.D.1    Lindstrom, A.B.2
  • 17
    • 0029020342 scopus 로고
    • Collection of a single alveolar exhaled breath for volatile organic compounds analysis
    • Pleil, J. D., Lindstrom, A.B. Collection of a single alveolar exhaled breath for volatile organic compounds analysis. Am. J. Ind. Med. 28, 109-121, 1995.
    • (1995) Am. J. Ind. Med. , vol.28 , pp. 109-121
    • Pleil, J.D.1    Lindstrom, A.B.2
  • 18
    • 0022527644 scopus 로고
    • Breath analysis: physiological basis and sampling techniques
    • Wilson, H.R. Breath analysis: physiological basis and sampling techniques. Scand. J. Work Environ. Health 12, 174-192, 1986.
    • (1986) Scand. J. Work Environ. Health , vol.12 , pp. 174-192
    • Wilson, H.R.1
  • 19
    • 0037107359 scopus 로고    scopus 로고
    • Ion mobility spectrometer for online monitoring of trace compounds
    • Li, F., Xie, Z., Schmidt, H., Sielemann, S., Baumbach, J. I. Ion mobility spectrometer for online monitoring of trace compounds. Spectrochim. Acta B 57, 1563-1574, 2002.
    • (2002) Spectrochim. Acta B , vol.57 , pp. 1563-1574
    • Li, F.1    Xie, Z.2    Schmidt, H.3    Sielemann, S.4    Baumbach, J.I.5
  • 20
    • 0022060984 scopus 로고
    • Recent advances in ion mobility spectrometry for explosives vapor detection
    • Spangler, G. E., Carrico, J. P., Campbell, D.N. Recent advances in ion mobility spectrometry for explosives vapor detection. J. Test. Eval. 13, 234-240, 1985.
    • (1985) J. Test. Eval. , vol.13 , pp. 234-240
    • Spangler, G.E.1    Carrico, J.P.2    Campbell, D.N.3
  • 21
    • 0033181259 scopus 로고    scopus 로고
    • Ion mobility spectrometry: arriving on site and moving beyond a low profile
    • Baumbach, J. I., Eiceman, G. A. Ion mobility spectrometry: arriving on site and moving beyond a low profile. Appl. Spectrosc. 53, 338-354, 1999.
    • (1999) Appl. Spectrosc. , vol.53 , pp. 338-354
    • Baumbach, J.I.1    Eiceman, G.A.2
  • 22
    • 34547448765 scopus 로고    scopus 로고
    • Detektion flüchtiger organischer Verbindungen mittels Ionenmobilitätsspektrometrie und deren Kopplung mit Multi-Kapillar-Gas-Chromatographie
    • Dissertation, University of Dortmund
    • Sielemann, S. Detektion flüchtiger organischer Verbindungen mittels Ionenmobilitätsspektrometrie und deren Kopplung mit Multi-Kapillar-Gas-Chromatographie. Dissertation, University of Dortmund, 1999.
    • (1999)
    • Sielemann, S.1
  • 23
    • 0002065022 scopus 로고    scopus 로고
    • Detection of trans-1,2-dichloroethene, trichloroethene and tetrachloroethene using multi-capillary columns coupled to ion mobility spectrometers with UV-ionization sources
    • Sielemann, S., Baumbach, J. I., Pilzecker, P., Walendzik, G. Detection of trans-1,2-dichloroethene, trichloroethene and tetrachloroethene using multi-capillary columns coupled to ion mobility spectrometers with UV-ionization sources. Int. J. Ion Mobility Spectrom. 2, 15-21, 1999.
    • (1999) Int. J. Ion Mobility Spectrom. , vol.2 , pp. 15-21
    • Sielemann, S.1    Baumbach, J.I.2    Pilzecker, P.3    Walendzik, G.4
  • 24
    • 0002286344 scopus 로고    scopus 로고
    • Determination of MTBE next to benzene, toluene and xylene within 90 s using GC/IMS with multi-capillary column
    • Sielemann, S., Xie, Z., Schmidt, H., Baumbach, J. I. Determination of MTBE next to benzene, toluene and xylene within 90 s using GC/IMS with multi-capillary column. Int. J. Ion Mobility Spectrom. 4, 69-73, 2001.
    • (2001) Int. J. Ion Mobility Spectrom. , vol.4 , pp. 69-73
    • Sielemann, S.1    Xie, Z.2    Schmidt, H.3    Baumbach, J.I.4
  • 26
    • 0036210983 scopus 로고    scopus 로고
    • Determination of acetone, 2-butanone, diethyl ketone and BTX using HSCC-UV-IMS
    • Xie, Z., Sielemann, S., Schmidt, H., Li, F., Baumbach, J. I. Determination of acetone, 2-butanone, diethyl ketone and BTX using HSCC-UV-IMS. Anal. Bioanal. Chem. 372, 606-610, 2002.
    • (2002) Anal. Bioanal. Chem. , vol.372 , pp. 606-610
    • Xie, Z.1    Sielemann, S.2    Schmidt, H.3    Li, F.4    Baumbach, J.I.5
  • 27
    • 0037443289 scopus 로고    scopus 로고
    • Detection of the gasoline components methyl tert-butyl ether, benzene, toluene, and m-xylene using ion mobility spectrometers with a radioactive and UV ionization source
    • Baumbach, J. I., Sielemann, S., Xie, Z., Schmidt, H. Detection of the gasoline components methyl tert-butyl ether, benzene, toluene, and m-xylene using ion mobility spectrometers with a radioactive and UV ionization source. Anal. Chem. 75, 1483-1490, 2003.
    • (2003) Anal. Chem. , vol.75 , pp. 1483-1490
    • Baumbach, J.I.1    Sielemann, S.2    Xie, Z.3    Schmidt, H.4
  • 28
    • 0004269112 scopus 로고
    • Ion Mobility Spectrometry
    • CRC Press, Boca Raton, FL,
    • Eiceman, G. A., Karpas, Z. Ion Mobility Spectrometry. CRC Press, Boca Raton, FL, 1994.
    • (1994)
    • Eiceman, G.A.1    Karpas, Z.2
  • 29
    • 0022440763 scopus 로고
    • Negative ion mobility spectrometry for selected inorganic pollutant gases and gas mixtures in air
    • Eiceman, G. A., Leasure, C. S., Vandiver, V. J. Negative ion mobility spectrometry for selected inorganic pollutant gases and gas mixtures in air. Anal. Chem. 58, 76-80, 1986.
    • (1986) Anal. Chem. , vol.58 , pp. 76-80
    • Eiceman, G.A.1    Leasure, C.S.2    Vandiver, V.J.3
  • 31
    • 0036240080 scopus 로고    scopus 로고
    • Micro-machined planar asymmetric ion mobility spectrometer as a gas chromatographic detector
    • Eiceman, G. A., Nazarov, E., Miller, R. A., Krylov, E.V., Zapata, A.M. Micro-machined planar asymmetric ion mobility spectrometer as a gas chromatographic detector. Analyst 127, 466-471, 2002.
    • (2002) Analyst , vol.127 , pp. 466-471
    • Eiceman, G.A.1    Nazarov, E.2    Miller, R.A.3    Krylov, E.V.4    Zapata, A.M.5
  • 33
    • 0037250332 scopus 로고    scopus 로고
    • A pulsed corona discharge switchable high resolution ion mobility spectrometer-mass spectrometer
    • Hill, C. A., Thomas, C. L. P. A pulsed corona discharge switchable high resolution ion mobility spectrometer-mass spectrometer. Analyst 128, 55-60, 2003.
    • (2003) Analyst , vol.128 , pp. 55-60
    • Hill, C.A.1    Thomas, C.L.P.2
  • 34
    • 0024000855 scopus 로고
    • Ion mobility spectrometry after chromatography-accomplishments, goals, challenges
    • Hill, H.H., Eatherton, R. L. Ion mobility spectrometry after chromatography-accomplishments, goals, challenges. J. Res. Natl Bureau Stand. 93, 425-426, 1988.
    • (1988) J. Res. Natl Bureau Stand. , vol.93 , pp. 425-426
    • Hill, H.H.1    Eatherton, R.L.2
  • 36
    • 84994952998 scopus 로고
    • Detection limits of an ion mobility detector after capillary gas chromatography
    • Sep. 2
    • St. Louis, R. H., Siems, W. F., Hill, H.H., Jr. Detection limits of an ion mobility detector after capillary gas chromatography. J. Microcolumn Sep. 2, 138-145, 1990.
    • (1990) J. Microcolumn , pp. 138-145
    • Louis St R.H, .1    Siems, W.F.2    Hill Jr, H.H.3
  • 37
    • 80051751860 scopus 로고
    • Ion mobility spectrometry in analytical chemistry
    • St. Louis, R. H., Hill, H.H., Jr. Ion mobility spectrometry in analytical chemistry. Crit. Rev. Anal. Chem. 21, 321-355, 1990.
    • (1990) Crit. Rev. Anal. Chem. , vol.21 , pp. 321-355
    • Louis St, R.H.1    Hill Jr, H.H.2
  • 38
    • 2442457789 scopus 로고    scopus 로고
    • Determination of terpenes in humid ambient air using ultraviolet ion mobility spectrometry.
    • Vautz, W., Sielemann, S., Baumbach, J. I. Determination of terpenes in humid ambient air using ultraviolet ion mobility spectrometry. Anal. Chim. Acta 513, 393-399, 2004.
    • (2004) Anal. Chim. Acta , vol.513 , pp. 393-399
    • Vautz, W.1    Sielemann, S.2    Baumbach, J.I.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.