-
1
-
-
0029256516
-
Non-invasive biosensors in clinical analysis
-
1. Guilbault GG, Palleschi G. Non-invasive biosensors in clinical analysis. Biosens Bioelectron 1995;10:379-92.
-
(1995)
Biosens Bioelectron
, vol.10
, pp. 379-392
-
-
Guilbault, G.G.1
Palleschi, G.2
-
2
-
-
0026969389
-
Breath tests in medicine
-
2. Philips M. Breath Tests in medicine. Sci Am 1992;7:74-9.
-
(1992)
Sci Am
, vol.7
, pp. 74-79
-
-
Philips, M.1
-
3
-
-
0015149936
-
The rapid determination of acetone in breath and plasma
-
3. Trotter MD, Sulway MJ, Trotter E. The rapid determination of acetone in breath and plasma. Clin Chim Acta 1971;35:137-43.
-
(1971)
Clin Chim Acta
, vol.35
, pp. 137-143
-
-
Trotter, M.D.1
Sulway, M.J.2
Trotter, E.3
-
4
-
-
0001006537
-
Studies of metabolic products in expired air. II. Acetone
-
4. Levey S, Balchum OJ, Medrano V, Jung R. Studies of metabolic products in expired air. II. Acetone. J Lab Clin Med 1964;63:574-84.
-
(1964)
J Lab Clin Med
, vol.63
, pp. 574-584
-
-
Levey, S.1
Balchum, O.J.2
Medrano, V.3
Jung, R.4
-
5
-
-
0014022301
-
Acetone in alveolar air and the control of diabetes
-
5. Rooth G, Ostenson S. Acetone in alveolar air and the control of diabetes. Lancet 1966;2:1102-5.
-
(1966)
Lancet
, vol.2
, pp. 1102-1105
-
-
Rooth, G.1
Ostenson, S.2
-
6
-
-
0014581431
-
Breath acetone and blood sugar measurements in diabetes
-
6. Barnett D, Tassopoulos CN, Fraser TR. Breath acetone and blood sugar measurements in diabetes. Clin Sci 1969;37:570.
-
(1969)
Clin Sci
, vol.37
, pp. 570
-
-
Barnett, D.1
Tassopoulos, C.N.2
Fraser, T.R.3
-
7
-
-
0020693943
-
The diagnostic potential of breath analysis
-
7. Manolis A. The diagnostic potential of breath analysis. [review]. Clin Chem 1983;29:5-15.
-
(1983)
Clin Chem
, vol.29
, pp. 5-15
-
-
Manolis, A.1
-
8
-
-
0018184738
-
Evaluation of volatile sulfur compounds in the expired alveolar gas in patients with liver cirrhosis
-
8. Kaji H, Hisamura M, Saito N, Murao M. Evaluation of volatile sulfur compounds in the expired alveolar gas in patients with liver cirrhosis. Clin Chim Acta 1978;85:279-84.
-
(1978)
Clin Chim Acta
, vol.85
, pp. 279-284
-
-
Kaji, H.1
Hisamura, M.2
Saito, N.3
Murao, M.4
-
9
-
-
0017780761
-
Biochemical profile of uremic breath
-
9. Simenhoff ML, Burke JF, Saukkonen JJ, Ordinario AT, Doty R. Biochemical profile of uremic breath. N Engl J Med 1977;297:132-5.
-
(1977)
N Engl J Med
, vol.297
, pp. 132-135
-
-
Simenhoff, M.L.1
Burke, J.F.2
Saukkonen, J.J.3
Ordinario, A.T.4
Doty, R.5
-
11
-
-
0014769163
-
Volatile fatty acids in the breath of patients with cirrhosis of the liver
-
11. Chen S, Mahadevan V, Zieve L. Volatile fatty acids in the breath of patients with cirrhosis of the liver. J Lab Clin Med 1970;75:622-7.
-
(1970)
J Lab Clin Med
, vol.75
, pp. 622-627
-
-
Chen, S.1
Mahadevan, V.2
Zieve, L.3
-
12
-
-
0014771862
-
Mercaptans and dimethyl sulfide in the breath of patients with cirrhosis of the liver-effect of feeding methionine
-
12. Chen S, Zieve L, Mahadevan V. Mercaptans and dimethyl sulfide in the breath of patients with cirrhosis of the liver-effect of feeding methionine. J Lab Clin Med 1970;75:628-35.
-
(1970)
J Lab Clin Med
, vol.75
, pp. 628-635
-
-
Chen, S.1
Zieve, L.2
Mahadevan, V.3
-
13
-
-
0028196575
-
Breath pentane is a marker of acute cardiac allograft rejection
-
13. Sobotka PA, Gupta DK, Lansky DM, Costanzo MR, Zarling EJ. Breath pentane is a marker of acute cardiac allograft rejection. J Heart Lung Transplant 1994;13:1147-9.
-
(1994)
J Heart Lung Transplant
, vol.13
, pp. 1147-1149
-
-
Sobotka, P.A.1
Gupta, D.K.2
Lansky, D.M.3
Costanzo, M.R.4
Zarling, E.J.5
-
14
-
-
0025752987
-
High breath pentane concentration during acute myocardial infarction
-
14. Weitz ZW, Birnbaum AJ, Sobotka PA, Zarling EJ, Skosey JL. High breath pentane concentration during acute myocardial infarction. Lancet 1991;337:933-5.
-
(1991)
Lancet
, vol.337
, pp. 933-935
-
-
Weitz, Z.W.1
Birnbaum, A.J.2
Sobotka, P.A.3
Zarling, E.J.4
Skosey, J.L.5
-
15
-
-
0028106556
-
Diet and oxidative stress in breast, colon and prostate cancer patients: A case-control study
-
15. Hietanen E, Bartsch JC, Camus AM, Mclinton S, Eremin O, Davidson L, et al. Diet and oxidative stress in breast, colon and prostate cancer patients: a case-control study. Eur J Clin Nutr 1994;48:575-86.
-
(1994)
Eur J Clin Nutr
, vol.48
, pp. 575-586
-
-
Hietanen, E.1
Bartsch, J.C.2
Camus, A.M.3
Mclinton, S.4
Eremin, O.5
Davidson, L.6
-
16
-
-
0030022873
-
Inhaled glucocorticoids decrease nitric oxide in exhaled air of asthmatic patients
-
16. Kharitonov SA, Yates DH, Barnes PJ. Inhaled glucocorticoids decrease nitric oxide in exhaled air of asthmatic patients. Am J Respir Crit Care Med 1996;153:454-7.
-
(1996)
Am J Respir Crit Care Med
, vol.153
, pp. 454-457
-
-
Kharitonov, S.A.1
Yates, D.H.2
Barnes, P.J.3
-
17
-
-
0029934167
-
Increased exhaled nitric oxide in asthma is mainly derived from the lower respiratory tract
-
17. Kharitonov SA, Chung KF, Evans D, O'Connor BJ, Barnes PJ. Increased exhaled nitric oxide in asthma is mainly derived from the lower respiratory tract. Am J Respir Crit Care Med 1996;153:1773-80.
-
(1996)
Am J Respir Crit Care Med
, vol.153
, pp. 1773-1780
-
-
Kharitonov, S.A.1
Chung, K.F.2
Evans, D.3
O'Connor, B.J.4
Barnes, P.J.5
-
18
-
-
0028095629
-
Assessment of liver metabolic function. Clinical implications
-
18. Brockmoller J, Roots I. Assessment of liver metabolic function. Clinical implications. Clin Pharmacokinet 1994;27:216-48.
-
(1994)
Clin Pharmacokinet
, vol.27
, pp. 216-248
-
-
Brockmoller, J.1
Roots, I.2
-
19
-
-
0028089756
-
Semiportable electrochemical instrument for determining carbon monoxide in breath
-
19. Vreman HJ, Stevenson DK, Oh W, Fanaroff AA, Wright LL, Lemons JA, et al. Semiportable electrochemical instrument for determining carbon monoxide in breath. Clin Chem 1994;40:1927-33.
-
(1994)
Clin Chem
, vol.40
, pp. 1927-1933
-
-
Vreman, H.J.1
Stevenson, D.K.2
Oh, W.3
Fanaroff, A.A.4
Wright, L.L.5
Lemons, J.A.6
-
20
-
-
0027967742
-
Bilirubin production in healthy term infants as measured by carbon monoxide in breath
-
20. Stevenson DK, Vreman HJ, Oh W, Fanaroff AA, Wright LL, Lemons JA, et al. Bilirubin production in healthy term infants as measured by carbon monoxide in breath. Clin Chem 1994;40:1934-9.
-
(1994)
Clin Chem
, vol.40
, pp. 1934-1939
-
-
Stevenson, D.K.1
Vreman, H.J.2
Oh, W.3
Fanaroff, A.A.4
Wright, L.L.5
Lemons, J.A.6
-
21
-
-
0030061342
-
Evalution of a fully automated end-tidal carbon monoxide instrument for breath analysis
-
21. Vreman HJ, Baxter LM, Stone RT, Stevenson DK. Evalution of a fully automated end-tidal carbon monoxide instrument for breath analysis. Clin Chem 1996;42:50-6.
-
(1996)
Clin Chem
, vol.42
, pp. 50-56
-
-
Vreman, H.J.1
Baxter, L.M.2
Stone, R.T.3
Stevenson, D.K.4
-
22
-
-
0022191230
-
Volatile organic compounds in exhaled air from patients with lung cancer
-
22. Gordon SM, Szidon JP, Krotoszynski BK, Gibbons RD, O'Neill HJ. Volatile organic compounds in exhaled air from patients with lung cancer. Clin Chem 1985;31:1278-82.
-
(1985)
Clin Chem
, vol.31
, pp. 1278-1282
-
-
Gordon, S.M.1
Szidon, J.P.2
Krotoszynski, B.K.3
Gibbons, R.D.4
O'Neill, H.J.5
-
23
-
-
0023750364
-
A computerized classification technique for screening for the presence of breath biomarkers in lung cancer
-
23. O'Neil HJ, Gordon SM, O'Neil MH, Gibbons RD, Szidon JP. A computerized classification technique for screening for the presence of breath biomarkers in lung cancer. Clin Chem 1988;34:1613-8.
-
(1988)
Clin Chem
, vol.34
, pp. 1613-1618
-
-
O'Neil, H.J.1
Gordon, S.M.2
O'Neil, M.H.3
Gibbons, R.D.4
Szidon, J.P.5
-
24
-
-
0023262778
-
Technique for gas chromatographic measurement of volatile alkanes from single-breath samples
-
24. Zarling EJ, Clapper M. Technique for gas chromatographic measurement of volatile alkanes from single-breath samples. Clin Chem 1987;33:140-1.
-
(1987)
Clin Chem
, vol.33
, pp. 140-141
-
-
Zarling, E.J.1
Clapper, M.2
-
25
-
-
0028103871
-
Pentane and isoprene in expired air from human: Gas chromatographic analysis of a single breath
-
25. Mendis S, Sobotka PA, Euler DE. Pentane and isoprene in expired air from human: gas chromatographic analysis of a single breath. Clin Chem 1994;40:1485-8.
-
(1994)
Clin Chem
, vol.40
, pp. 1485-1488
-
-
Mendis, S.1
Sobotka, P.A.2
Euler, D.E.3
-
26
-
-
0031149661
-
Method for the collection and assay of volatile organic compounds in breath
-
26. Phillips M. Method for the collection and assay of volatile organic compounds in breath. Anal Biochem 1997;247:272-8.
-
(1997)
Anal Biochem
, vol.247
, pp. 272-278
-
-
Phillips, M.1
-
28
-
-
0028656454
-
Metabolic and environmental origins of volatile organic compounds in breath
-
28. Phillips M, Greenberg J, Awad J. Metabolic and environmental origins of volatile organic compounds in breath. J Clin Pathol 1994;47:1052-3.
-
(1994)
J Clin Pathol
, vol.47
, pp. 1052-1053
-
-
Phillips, M.1
Greenberg, J.2
Awad, J.3
-
30
-
-
0025366409
-
Comparison of three sampling and analytical methods for measuring m-xylene in expired air of exposed humans
-
30. Glaser RA, Arnold JE, Shulman SA. Comparison of three sampling and analytical methods for measuring m-xylene in expired air of exposed humans. Am Ind Hyg Assoc J 1990;51:139-50.
-
(1990)
Am Ind Hyg Assoc J
, vol.51
, pp. 139-150
-
-
Glaser, R.A.1
Arnold, J.E.2
Shulman, S.A.3
-
31
-
-
0026544914
-
The use of transportable fourier transform infrared (FTIR) spectrometer for the direct measurement of solvents in breath and ambient air. I. Methanol
-
31. Franzblau A, Levine SP, Burgess LA, Qu Qing-shan, Schreck RM, Darcy JB. The use of transportable fourier transform infrared (FTIR) spectrometer for the direct measurement of solvents in breath and ambient air. I. Methanol. Adv Ind Environ Hyg 1992;53:221-7.
-
(1992)
Adv Ind Environ Hyg
, vol.53
, pp. 221-227
-
-
Franzblau, A.1
Levine, S.P.2
Burgess, L.A.3
Qu, Q.-S.4
Schreck, R.M.5
Darcy, J.B.6
-
32
-
-
0018666799
-
Improved gas chromatographic quantitation of breath hydrogen by normalization to respiratory carbon dioxide
-
32. Niu HC, Scheller DA, Klein PD. Improved gas chromatographic quantitation of breath hydrogen by normalization to respiratory carbon dioxide. J Lab Clin Med 1979;94:755-63.
-
(1979)
J Lab Clin Med
, vol.94
, pp. 755-763
-
-
Niu, H.C.1
Scheller, D.A.2
Klein, P.D.3
-
33
-
-
0022444215
-
Occupational exposure monitoring using breath analysis
-
33. Droz PO, Guillemin MP. Occupational exposure monitoring using breath analysis. J Occup Med 1986;28:593-602.
-
(1986)
J Occup Med
, vol.28
, pp. 593-602
-
-
Droz, P.O.1
Guillemin, M.P.2
-
34
-
-
0026605510
-
Ion-trap detection of volatile organic compounds in alveolar breath
-
34. Phillips M, Greenberg J. Ion-trap detection of volatile organic compounds in alveolar breath. Clin Chem 1992;38:60-5.
-
(1992)
Clin Chem
, vol.38
, pp. 60-65
-
-
Phillips, M.1
Greenberg, J.2
-
35
-
-
0029883514
-
Investigation of organic vapor losses to condensed water vapor in tedlar bags used for exhaled-breath sampling
-
35. Groves WA, Zellers ET. Investigation of organic vapor losses to condensed water vapor in tedlar bags used for exhaled-breath sampling. Am Ind Hyg Assoc J 1996;57:257-63.
-
(1996)
Am Ind Hyg Assoc J
, vol.57
, pp. 257-263
-
-
Groves, W.A.1
Zellers, E.T.2
-
36
-
-
0026096823
-
Method for the collection and analysis of volatile compounds in the breath
-
36. Philips M, Greenberg J. Method for the collection and analysis of volatile compounds in the breath. Biomed Appl 1991;242-9.
-
(1991)
Biomed Appl
, pp. 242-249
-
-
Philips, M.1
Greenberg, J.2
-
37
-
-
0027215962
-
Is N-pentane really an index of lipid peroxidation in human and animals? A methodological reevaluation
-
37. Kohlmuller D, Kochen W. Is N-pentane really an index of lipid peroxidation in human and animals? A methodological reevaluation. Anal Biochem 1993;210:268-76.
-
(1993)
Anal Biochem
, vol.210
, pp. 268-276
-
-
Kohlmuller, D.1
Kochen, W.2
-
39
-
-
0029958818
-
A simple, reliable method for the determination of chlorinated volatile organics in human breath and air using glass sampling tubes
-
39. Stein VB, Narang RS, Wilson L, Aldous KM. A simple, reliable method for the determination of chlorinated volatile organics in human breath and air using glass sampling tubes. J Anal Toxicol 1996;20:145-50.
-
(1996)
J Anal Toxicol
, vol.20
, pp. 145-150
-
-
Stein, V.B.1
Narang, R.S.2
Wilson, L.3
Aldous, K.M.4
-
40
-
-
0024432850
-
Characterization of carbon molecular sieves and activated charcoal for use in airborne contaminant sampling
-
40. Betz WR, Maroldo SG, Wachob GD, Firth MC. Characterization of carbon molecular sieves and activated charcoal for use in airborne contaminant sampling. Am Ind Hyg Assoc J 1989;50:181-7.
-
(1989)
Am Ind Hyg Assoc J
, vol.50
, pp. 181-187
-
-
Betz, W.R.1
Maroldo, S.G.2
Wachob, G.D.3
Firth, M.C.4
-
42
-
-
0029663708
-
Technique for monitoring toxic VOCs in air sorbent preconcentration, closed-cycle cooler cryofocusing and GC/MS analysis
-
42. Oliver KD, Adan JR, Daughtrey EH JR, Mcclenny WA, Yoong MJ, Pardee MA, et al. Technique for monitoring toxic VOCs in air sorbent preconcentration, closed-cycle cooler cryofocusing and GC/MS Analysis. Environ Sci Technol 1996;30:1939-45.
-
(1996)
Environ Sci Technol
, vol.30
, pp. 1939-1945
-
-
Oliver, K.D.1
Adan, J.R.2
Daughtrey E.H., Jr.3
Mcclenny, W.A.4
Yoong, M.J.5
Pardee, M.A.6
-
43
-
-
0028485626
-
Office worker's exposure to volatile organic compounds while commuting and working in Taipei city
-
43. Chan CC, Lin SH, Her GR. Office worker's exposure to volatile organic compounds while commuting and working in Taipei city. Atmospheric Environment 1994;28:2351-9.
-
(1994)
Atmospheric Environment
, vol.28
, pp. 2351-2359
-
-
Chan, C.C.1
Lin, S.H.2
Her, G.R.3
-
44
-
-
0024321181
-
Porous-layer open-tubular gas chromatography in combination with an ion-trap detector to assess volatile metabolites in human breath
-
44. Ghoos Y, Hiele M, Rutgeets P, Vantrappen G. Porous-layer open-tubular gas chromatography in combination with an ion-trap detector to assess volatile metabolites in human breath. Biomed Environ Mass Spectrom 1989;18:613-6.
-
(1989)
Biomed Environ Mass Spectrom
, vol.18
, pp. 613-616
-
-
Ghoos, Y.1
Hiele, M.2
Rutgeets, P.3
Vantrappen, G.4
-
45
-
-
0028277936
-
The potential of the hydrocarbon breath test as a measure of lipid peroxidation
-
45. Kneepkens CMF, Lepage G, Roy CC. The potential of the hydrocarbon breath test as a measure of lipid peroxidation. [review]. Free Radic Biol Med 1994;17:127-60.
-
(1994)
Free Radic Biol Med
, vol.17
, pp. 127-160
-
-
Kneepkens, C.M.F.1
Lepage, G.2
Roy, C.C.3
-
46
-
-
0027430871
-
Minimum analysis requirements for the detection of Helicobacter pylori inflection by the 13C-urea breath test
-
46. Klein PD, Graham DY. Minimum analysis requirements for the detection of Helicobacter pylori inflection by the 13C-urea breath test. Am J Gastroenterol 1993;88:1865-9.
-
(1993)
Am J Gastroenterol
, vol.88
, pp. 1865-1869
-
-
Klein, P.D.1
Graham, D.Y.2
-
47
-
-
0029872421
-
Noninvasive detection of Helicobacter pylori infection in clinical practice: The 13C urea breath test
-
47. Klein PD, Malaty HM, Graham KS, Genta RM, Graham DY. Noninvasive detection of Helicobacter pylori infection in clinical practice: the 13C urea breath test. Am J Gastroenterol 1996;91:690-4.
-
(1996)
Am J Gastroenterol
, vol.91
, pp. 690-694
-
-
Klein, P.D.1
Malaty, H.M.2
Graham, K.S.3
Genta, R.M.4
Graham, D.Y.5
-
48
-
-
0014904179
-
Pulmonary elimination of toxic substances. Measurement and toxological applications
-
48. Pebay-Ppeyroula F, Nicaise AM. Pulmonary elimination of toxic substances. Measurement and toxological applications. Poumon Coeur 1970;26:853-66.
-
(1970)
Poumon Coeur
, vol.26
, pp. 853-866
-
-
Pebay-Ppeyroula, F.1
Nicaise, A.M.2
-
49
-
-
0028585805
-
Clinically feasible stable isotope technique at a reasonable price: Analysis of 13CO2/12CO2-abundance in breath samples with a new isotope selective-nondispersive infrared spectrometer
-
49. Braden B, Haisch M, Duan LP, Lembcke B, Caspary WF, Hering P. Clinically feasible stable isotope technique at a reasonable price: analysis of 13CO2/12CO2-abundance in breath samples with a new isotope selective-nondispersive infrared spectrometer. Zeitschr Gastroenterol 1994;32:675-8.
-
(1994)
Zeitschr Gastroenterol
, vol.32
, pp. 675-678
-
-
Braden, B.1
Haisch, M.2
Duan, L.P.3
Lembcke, B.4
Caspary, W.F.5
Hering, P.6
-
50
-
-
0029934987
-
Nondispersive isotope-selective infrared spectroscopy: A new analytical method for 13C-urea breath test
-
50. Braden B, Schafer F, Caspary WF, Lembcke B. Nondispersive isotope-selective infrared spectroscopy: a new analytical method for 13C-urea breath test. Scand J Gastroenterol 1996;31:442-5.
-
(1996)
Scand J Gastroenterol
, vol.31
, pp. 442-445
-
-
Braden, B.1
Schafer, F.2
Caspary, W.F.3
Lembcke, B.4
-
51
-
-
0029658632
-
New approach to 13C-urea breath test: Capsule-based modification with low-dose of 13C-urea in the diagnosis of Helicobacter pylori infection
-
51. Bielanski W, Konturek SK. New approach to 13C-urea breath test: capsule-based modification with low-dose of 13C-urea in the diagnosis of Helicobacter pylori infection. J Physiol Pharmacol 1996;47:545-53.
-
(1996)
J Physiol Pharmacol
, vol.47
, pp. 545-553
-
-
Bielanski, W.1
Konturek, S.K.2
-
52
-
-
0030293710
-
Selected ion flow tube: A technique for quantitative trace gas analysis of air and breath
-
52. Spanel P, Smith D. Selected ion flow tube: a technique for quantitative trace gas analysis of air and breath [review]. Med Biol Eng Comput 1996;34:409-19.
-
(1996)
Med Biol Eng Comput
, vol.34
, pp. 409-419
-
-
Spanel, P.1
Smith, D.2
-
53
-
-
0029760904
-
The novel selected ion flow tube approach to trace gas analysis of air and breath
-
53. Smith D, Spanel P. The novel selected ion flow tube approach to trace gas analysis of air and breath [review]. Rapid Commun Mass Spectrum 1996;10:1183-98.
-
(1996)
Rapid Commun Mass Spectrum
, vol.10
, pp. 1183-1198
-
-
Smith, D.1
Spanel, P.2
-
54
-
-
0030123928
-
A new monitor with a zinc-oxide thin film semiconductor sensor for the measurement of volatile sulfur compounds in mouth air
-
54. Shimura M, Yasuno Y, Iwakura M, Shimada Y, Sakai S, Suzuki K, et al. A new monitor with a zinc-oxide thin film semiconductor sensor for the measurement of volatile sulfur compounds in mouth air. J Periodontol 1996;67:396-402.
-
(1996)
J Periodontol
, vol.67
, pp. 396-402
-
-
Shimura, M.1
Yasuno, Y.2
Iwakura, M.3
Shimada, Y.4
Sakai, S.5
Suzuki, K.6
-
55
-
-
0030459698
-
Prototype instrument employing a microsensor array for the analysis of organic vapors in exhaled breath
-
55. Groves WA, Zellers ET. Prototype instrument employing a microsensor array for the analysis of organic vapors in exhaled breath. Am Ind Hyg Assoc J 1996;57:1103-8.
-
(1996)
Am Ind Hyg Assoc J
, vol.57
, pp. 1103-1108
-
-
Groves, W.A.1
Zellers, E.T.2
-
56
-
-
0023868603
-
The origin of hydrogen cyanide in breath
-
56. Lundquist P, Rosling H, Sorbo B. The origin of hydrogen cyanide in breath. Arch Toxicol 1988;61:270-4.
-
(1988)
Arch Toxicol
, vol.61
, pp. 270-274
-
-
Lundquist, P.1
Rosling, H.2
Sorbo, B.3
-
57
-
-
0030062096
-
Effect of cigarette smoking on pentane excretion in alveolar breath
-
57. Euler DE, Dave SJ, Guo H. Effect of cigarette smoking on pentane excretion in alveolar breath. Clin Chem 1996;42:303-8.
-
(1996)
Clin Chem
, vol.42
, pp. 303-308
-
-
Euler, D.E.1
Dave, S.J.2
Guo, H.3
-
58
-
-
0027389917
-
Breath acetone analyzer: Diagnostic tool to monitor dietary fat loss
-
58. Kundu SK, Bruzek JA, Nair R, Judilla AM. Breath acetone analyzer: diagnostic tool to monitor dietary fat loss. Clin Chem 1993;39:87-92.
-
(1993)
Clin Chem
, vol.39
, pp. 87-92
-
-
Kundu, S.K.1
Bruzek, J.A.2
Nair, R.3
Judilla, A.M.4
-
59
-
-
0015952772
-
Ethane evaluation: A new index of lipid peroxidation
-
59. Riely CA, Cohen G, Lieberman M. Ethane evaluation: a new index of lipid peroxidation. Science 1974;183:208-10.
-
(1974)
Science
, vol.183
, pp. 208-210
-
-
Riely, C.A.1
Cohen, G.2
Lieberman, M.3
-
60
-
-
0018248257
-
Effects of exercise, vitamin E, and ozone on pulmonary function and lipid peroxidation
-
60. Dillard CJ, Litor RE, Savin WM, Dumelin EE, Tappel AL. Effects of exercise, vitamin E, and ozone on pulmonary function and lipid peroxidation. Appl Physiol 1978;45:927-32.
-
(1978)
Appl Physiol
, vol.45
, pp. 927-932
-
-
Dillard, C.J.1
Litor, R.E.2
Savin, W.M.3
Dumelin, E.E.4
Tappel, A.L.5
-
61
-
-
0017362466
-
Effect of physical workload on retention and metabolism of inhaled organic solvents. A comparative theoretical approach and its application with regards to exposure monitoring
-
61. Droz PO, Fernandez JG. Effect of physical workload on retention and metabolism of inhaled organic solvents. A comparative theoretical approach and its application with regards to exposure monitoring. Int Arch Occup Environ Health 1977;38:231-46.
-
(1977)
Int Arch Occup Environ Health
, vol.38
, pp. 231-246
-
-
Droz, P.O.1
Fernandez, J.G.2
-
62
-
-
0013578048
-
Saliva signals ovulation
-
62. Kostelc JG. Saliva signals ovulation. Clin Chem News 1981;7:1-10.
-
(1981)
Clin Chem News
, vol.7
, pp. 1-10
-
-
Kostelc, J.G.1
-
63
-
-
0024278258
-
Enzymatic catalysis in nonaqueous solvents
-
63. Zaks A, Dlibanov AM. Enzymatic catalysis in nonaqueous solvents. J Biol Chem 1988;7:3194-201.
-
(1988)
J Biol Chem
, vol.7
, pp. 3194-3201
-
-
Zaks, A.1
Dlibanov, A.M.2
-
64
-
-
0024287893
-
The effect of water on enzyme action in organic media
-
64. Zaks A, Dlibanov AM. The effect of water on enzyme action in organic media. J Biol Chem 1988;263:8017.
-
(1988)
J Biol Chem
, vol.263
, pp. 8017
-
-
Zaks, A.1
Dlibanov, A.M.2
-
66
-
-
0027686244
-
Biocatalysis in the gas phase
-
66. Lamare S, Legory M. Biocatalysis in the gas phase. Tibetch 1993;11:415-8.
-
(1993)
Tibetch
, vol.11
, pp. 415-418
-
-
Lamare, S.1
Legory, M.2
-
67
-
-
0027571697
-
Phenol removal from waste gases with a biological filter by Pseudomonas putida
-
67. Zilli M, Lodi A, Del Borghi M, Ferraiolo G. Phenol removal from waste gases with a biological filter by Pseudomonas putida. Biotechnol Bioeng 1993;41:693-9.
-
(1993)
Biotechnol Bioeng
, vol.41
, pp. 693-699
-
-
Zilli, M.1
Lodi, A.2
Del Borghi, M.3
Ferraiolo, G.4
-
68
-
-
0026157726
-
Activities of Candida rugosa lipase and other esterolytic enzymes in thin liquid films
-
68. Ross NW, Schneider H. Activities of Candida rugosa lipase and other esterolytic enzymes in thin liquid films. Enzyme Microb Technol 1991;13:370-7.
-
(1991)
Enzyme Microb Technol
, vol.13
, pp. 370-377
-
-
Ross, N.W.1
Schneider, H.2
-
70
-
-
0020821792
-
Determination of formaldehyde with an enzyme-coated piezoelectric crystal detector
-
70. Guilbault GG. Determination of formaldehyde with an enzyme-coated piezoelectric crystal detector. Anal Chem 1983;55:1682-4.
-
(1983)
Anal Chem
, vol.55
, pp. 1682-1684
-
-
Guilbault, G.G.1
-
72
-
-
0001536384
-
Piezoelectric quartz crystal detection of ammonia using pyridoxine supported on a polyethoxylate matrix
-
72. Lai CSI, Moody GI, Thomas JDR. Piezoelectric quartz crystal detection of ammonia using pyridoxine supported on a polyethoxylate matrix. Analyst 1986;111:511-5.
-
(1986)
Analyst
, vol.111
, pp. 511-515
-
-
Lai, C.S.I.1
Moody, G.I.2
Thomas, J.D.R.3
-
74
-
-
0024545560
-
Fourier analysis method for temperature compensation of a microcomputer-controlled piezoelectric crystal sulphur dioxide sensor
-
74. Snook RD, Zaft PE. Fourier analysis method for temperature compensation of a microcomputer-controlled piezoelectric crystal sulphur dioxide sensor. Analyst 1989;114:149-53.
-
(1989)
Analyst
, vol.114
, pp. 149-153
-
-
Snook, R.D.1
Zaft, P.E.2
-
75
-
-
0016641403
-
The detection of ammonia and nitrogen dioxide at the parts per billion level with coated piezoelectric crystal detectors
-
75. Karmarkar KH, Guilbault GG. The detection of ammonia and nitrogen dioxide at the parts per billion level with coated piezoelectric crystal detectors. Analyst 1975;75:111-7.
-
(1975)
Analyst
, vol.75
, pp. 111-117
-
-
Karmarkar, K.H.1
Guilbault, G.G.2
-
76
-
-
0001022603
-
Development of a multi-sensor system using coated piezoelectric crystal detectors
-
76. Fraser SM, Edmondst TE, West TS. Development of a multi-sensor system using coated piezoelectric crystal detectors. Analyst 1986;111:1183-8.
-
(1986)
Analyst
, vol.111
, pp. 1183-1188
-
-
Fraser, S.M.1
Edmondst, T.E.2
West, T.S.3
-
77
-
-
0028943661
-
Gas sensing using thin organic film
-
77. Petty MC. Gas sensing using thin organic film. Biosens Bioelectron 1995;10:129-34.
-
(1995)
Biosens Bioelectron
, vol.10
, pp. 129-134
-
-
Petty, M.C.1
-
79
-
-
0018129626
-
Detection of ammonia in ambient air with coated piezoelectric crystal detector
-
79. Hlava J, Guilbault GG. Detection of ammonia in ambient air with coated piezoelectric crystal detector. Anal Chem 1978;50:1044-6.
-
(1978)
Anal Chem
, vol.50
, pp. 1044-1046
-
-
Hlava, J.1
Guilbault, G.G.2
-
80
-
-
0000102536
-
A polymer support for pyridoxine hydrochloride used as a sorbent for the piezoelectric crystal detection of ammonia
-
80. Moody GJ, Thomas JDR, Yarmo MA. A polymer support for pyridoxine hydrochloride used as a sorbent for the piezoelectric crystal detection of ammonia. Analytica Chimica Acta 1983;155:225-9.
-
(1983)
Analytica Chimica Acta
, vol.155
, pp. 225-229
-
-
Moody, G.J.1
Thomas, J.D.R.2
Yarmo, M.A.3
|