메뉴 건너뛰기




Volumn 51, Issue 8, 2013, Pages 827-833

Computer-assisted orthognathic surgery: Waferless maxillary positioning, versatility, and accuracy of an image-guided visualisation display

Author keywords

3D cephalometry; Interactive image guided visualization display; Orthognathic surgery; Surgical navigation; Virtual orthognathic planning

Indexed keywords

ACCURACY; ADULT; ARTICLE; CAMERA; CEPHALOMETRY; CLINICAL ARTICLE; FACE ASYMMETRY; FEMALE; HUMAN; INTRAOPERATIVE PERIOD; MALE; MALOCCLUSION; MAXILLA HYPOPLASIA; MAXILLOFACIAL SURGERY; ORTHOGNATHIC SURGERY; OSTEOTOMY; RETROGNATHIA; TISSUES; TREATMENT PLANNING; ANATOMIC LANDMARK; COMPUTER ASSISTED SURGERY; COMPUTER GRAPHICS; COMPUTER INTERFACE; FRONTAL BONE; INFORMATION PROCESSING; JAW RELATION RECORD; MALOCCLUSION, ANGLE CLASS III; MAXILLA; OPEN BITE; OPERATION DURATION; PATHOLOGY; PATIENT CARE PLANNING; PROCEDURES; STEREOTACTIC PROCEDURE; THREE DIMENSIONAL IMAGING; TREATMENT OUTCOME; VIDEORECORDING; VISION; YOUNG ADULT; ZYGOMA;

EID: 84889880204     PISSN: 02664356     EISSN: 15321940     Source Type: Journal    
DOI: 10.1016/j.bjoms.2013.06.014     Document Type: Article
Times cited : (115)

References (24)
  • 1
    • 33845905184 scopus 로고    scopus 로고
    • Three-dimensional cone-beam computed tomography for assessment of mandibular changes after orthognathic surgery
    • L.H. Cevidanes, L.J. Bailey, and S.F. Tucker Three-dimensional cone-beam computed tomography for assessment of mandibular changes after orthognathic surgery Am J Orthod Dentofacial Orthop 131 2007 44 50
    • (2007) Am J Orthod Dentofacial Orthop , vol.131 , pp. 44-50
    • Cevidanes, L.H.1    Bailey, L.J.2    Tucker, S.F.3
  • 2
    • 33749448868 scopus 로고    scopus 로고
    • Variations in orthodontic treatment planning decisions of class II patients between virtual 3-dimensional models and traditional plaster study models
    • J.L. Whetten, P.C. Williamson, and G. Heo Variations in orthodontic treatment planning decisions of class II patients between virtual 3-dimensional models and traditional plaster study models Am J Orthod Dentofacial Orthop 130 2006 485 491
    • (2006) Am J Orthod Dentofacial Orthop , vol.130 , pp. 485-491
    • Whetten, J.L.1    Williamson, P.C.2    Heo, G.3
  • 3
    • 3242775482 scopus 로고    scopus 로고
    • Limitations of orthognathic model surgery: Theoretical and practical implications (paper in French)
    • R. Olszewski, and H. Reychler Limitations of orthognathic model surgery: theoretical and practical implications (paper in French) Rev Stomatol Chir Maxillofac 105 2004 165 169
    • (2004) Rev Stomatol Chir Maxillofac , vol.105 , pp. 165-169
    • Olszewski, R.1    Reychler, H.2
  • 4
    • 0026528428 scopus 로고
    • Three-dimensional craniofacial surgery; Transfer from a three-dimensional model (Endoplan) to clinical surgery; A new technique (Graz)
    • H. Kärcher Three-dimensional craniofacial surgery; transfer from a three-dimensional model (Endoplan) to clinical surgery; a new technique (Graz) J Craniomaxillofac Surg 20 1992 125 131
    • (1992) J Craniomaxillofac Surg , vol.20 , pp. 125-131
    • Kärcher, H.1
  • 5
    • 0034496105 scopus 로고    scopus 로고
    • 3-D COSMOS. A new 3D model based computerised operation simulation and navigation system
    • G. Santler 3-D COSMOS. A new 3D model based computerised operation simulation and navigation system J Craniomaxillofac Surg 28 2000 287 293
    • (2000) J Craniomaxillofac Surg , vol.28 , pp. 287-293
    • Santler, G.1
  • 6
    • 78751585177 scopus 로고    scopus 로고
    • Medial canthal region as an external reference point in orthognathic surgery
    • J.N. Gil, F.E. Campos, and J.D. Claus Medial canthal region as an external reference point in orthognathic surgery J Oral Maxillofac Surg 69 2011 352 355
    • (2011) J Oral Maxillofac Surg , vol.69 , pp. 352-355
    • Gil, J.N.1    Campos, F.E.2    Claus, J.D.3
  • 7
    • 0025013918 scopus 로고
    • Accuracy of model surgery: Evaluation of an old technique and introduction of a new one
    • E. Ellis III. Accuracy of model surgery: evaluation of an old technique and introduction of a new one J Oral Maxillofac Surg 48 1990 1161 1167
    • (1990) J Oral Maxillofac Surg , vol.48 , pp. 1161-1167
    • Ellis III, E.1
  • 8
    • 13344260607 scopus 로고    scopus 로고
    • Comparison of the predicted surgical results following virtual planning with those actually achieved following bimaxillary operation of dysgnathia
    • M. Schneider, O. Tzscharnke, and E. Pilling Comparison of the predicted surgical results following virtual planning with those actually achieved following bimaxillary operation of dysgnathia J Craniomaxillofac Surg 33 2005 8 12
    • (2005) J Craniomaxillofac Surg , vol.33 , pp. 8-12
    • Schneider, M.1    Tzscharnke, O.2    Pilling, E.3
  • 9
    • 57649193116 scopus 로고    scopus 로고
    • Comparison of the accuracy of the three-dimensional virtual method and the conventional manual method for model surgery and intermediate wafer fabrication
    • K.G. Song, and S.H. Baek Comparison of the accuracy of the three-dimensional virtual method and the conventional manual method for model surgery and intermediate wafer fabrication Oral Surg Oral Med Oral Pathol Oral Radiol Endod 107 2009 13 21
    • (2009) Oral Surg Oral Med Oral Pathol Oral Radiol Endod , vol.107 , pp. 13-21
    • Song, K.G.1    Baek, S.H.2
  • 10
    • 84857239510 scopus 로고    scopus 로고
    • Orthognathic treatment of asymmetry: Two cases of "waferless" stereotactic maxillary positioning
    • Z. Sadiq, J. Collyer, and K. Sneddon Orthognathic treatment of asymmetry: two cases of "waferless" stereotactic maxillary positioning Br J Oral Maxillofac Surg 50 2012 27 29
    • (2012) Br J Oral Maxillofac Surg , vol.50 , pp. 27-29
    • Sadiq, Z.1    Collyer, J.2    Sneddon, K.3
  • 11
    • 4444357004 scopus 로고    scopus 로고
    • Indications and limitations of intraoperative navigation in maxillofacial surgery
    • M. Heiland, C.R. Habermann, and R. Schmelzle Indications and limitations of intraoperative navigation in maxillofacial surgery J Oral Maxillofac Surg 62 2004 1059 1063
    • (2004) J Oral Maxillofac Surg , vol.62 , pp. 1059-1063
    • Heiland, M.1    Habermann, C.R.2    Schmelzle, R.3
  • 12
  • 13
    • 79952216632 scopus 로고    scopus 로고
    • Computer planning and intraoperative navigation in orthognathic surgery
    • R.B. Bell Computer planning and intraoperative navigation in orthognathic surgery J Oral Maxillofac Surg 69 2011 592 605
    • (2011) J Oral Maxillofac Surg , vol.69 , pp. 592-605
    • Bell, R.B.1
  • 14
    • 33845526039 scopus 로고    scopus 로고
    • Application of an augmented reality tool for maxillary positioning in orthognathic surgery: A feasibility study
    • R.A. Mischkowski, M.J. Zinser, and A.C. Kübler Application of an augmented reality tool for maxillary positioning in orthognathic surgery: a feasibility study J Craniomaxillofac Surg 34 2006 478 483
    • (2006) J Craniomaxillofac Surg , vol.34 , pp. 478-483
    • Mischkowski, R.A.1    Zinser, M.J.2    Kübler, A.C.3
  • 15
    • 34447626619 scopus 로고    scopus 로고
    • Intraoperative navigation in the maxillofacial area based on 3D imaging obtained by a cone-beam device
    • R.A. Mischkowski, M.J. Zinser, and L. Ritter Intraoperative navigation in the maxillofacial area based on 3D imaging obtained by a cone-beam device Int J Oral Maxillofac Surg 36 2007 687 694
    • (2007) Int J Oral Maxillofac Surg , vol.36 , pp. 687-694
    • Mischkowski, R.A.1    Zinser, M.J.2    Ritter, L.3
  • 16
    • 70249136888 scopus 로고    scopus 로고
    • Three-dimensional treatment planning of orthognathic surgery in the era of virtual imaging
    • Erratum in: J Oral Maxillofac Surg 2009;67:2703
    • G.R.J. Swennen, W. Mollemans, and F. Schutyser Three-dimensional treatment planning of orthognathic surgery in the era of virtual imaging J Oral Maxillofac Surg 67 2009 2080 2092 Erratum in: J Oral Maxillofac Surg 2009;67:2703
    • (2009) J Oral Maxillofac Surg , vol.67 , pp. 2080-2092
    • Swennen, G.R.J.1    Mollemans, W.2    Schutyser, F.3
  • 17
  • 19
    • 0030884988 scopus 로고    scopus 로고
    • Computerized cephalometric evaluation of orthognathic surgical precision and stability in relation to maxillary superior repositioning combined with mandibular advancement or setback
    • O. Donatsky, J. Bjørn-Jørgensen, and M. Holmqvist-Larsen Computerized cephalometric evaluation of orthognathic surgical precision and stability in relation to maxillary superior repositioning combined with mandibular advancement or setback J Oral Maxillofac Surg 55 1997 1071 1080
    • (1997) J Oral Maxillofac Surg , vol.55 , pp. 1071-1080
    • Donatsky, O.1    Bjørn-Jørgensen, J.2    Holmqvist-Larsen, M.3
  • 21
    • 84856086092 scopus 로고    scopus 로고
    • 3D planning in orthognathic surgery: CAD/CAM surgical splints and prediction of the soft and hard tissues results: Our experience in 16 cases
    • S. Aboul-Hosn Centenero, and F. Hernández-Alfaro 3D planning in orthognathic surgery: CAD/CAM surgical splints and prediction of the soft and hard tissues results: our experience in 16 cases J Craniomaxillofac Surg 40 2011 162 168
    • (2011) J Craniomaxillofac Surg , vol.40 , pp. 162-168
    • Aboul-Hosn Centenero, S.1    Hernández-Alfaro, F.2
  • 22
    • 0030990277 scopus 로고    scopus 로고
    • Virtual reality for orthognathic surgery: The augmented reality environment concept
    • A. Wagner, M. Rasse, and W. Millesi Virtual reality for orthognathic surgery: the augmented reality environment concept J Oral Maxillofac Surg 55 1997 456 463
    • (1997) J Oral Maxillofac Surg , vol.55 , pp. 456-463
    • Wagner, A.1    Rasse, M.2    Millesi, W.3
  • 23
    • 34248551137 scopus 로고    scopus 로고
    • A new system for computer-aided preoperative planning and intraoperative navigation during corrective jaw surgery
    • J. Chapuis, A. Schramm, and I. Pappas A new system for computer-aided preoperative planning and intraoperative navigation during corrective jaw surgery IEEE Trans Inf Technol Biomed 11 2007 274 287
    • (2007) IEEE Trans Inf Technol Biomed , vol.11 , pp. 274-287
    • Chapuis, J.1    Schramm, A.2    Pappas, I.3
  • 24
    • 34249799879 scopus 로고    scopus 로고
    • The use of a wax bite wafer and a double computed tomography scan procedure to obtain a three-dimensional augmented virtual skull model
    • G.R. Swennen, M.Y. Mommaerts, and J. Abeloos The use of a wax bite wafer and a double computed tomography scan procedure to obtain a three-dimensional augmented virtual skull model J Craniofac Surg 18 2007 533 539
    • (2007) J Craniofac Surg , vol.18 , pp. 533-539
    • Swennen, G.R.1    Mommaerts, M.Y.2    Abeloos, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.