메뉴 건너뛰기




Volumn 51, Issue 8, 2013, Pages

A novel method of computer aided orthognathic surgery using individual CAD/CAM templates: A combination of osteotomy and repositioning guides

Author keywords

Computer aided design and computer aided manufacture; Individual templates; Orthognathic surgery; Three dimensional planning

Indexed keywords

ADULT; ARTICLE; CLINICAL ARTICLE; COMPUTER AIDED DESIGN; COMPUTER AIDED MANUFACTURE; COMPUTER ASSISTED SURGERY; COMPUTER ASSISTED TOMOGRAPHY; DENTAL MAXILLOFACIAL DEFORMITY; FEMALE; HUMAN; INFORMATION PROCESSING; MALE; MAXILLA OSTEOTOMY; MAXILLOFACIAL DISORDER; OCCLUSAL SPLINT; ORTHOGNATHIC SURGERY; PATIENT SATISFACTION; TREATMENT PLANNING; ANATOMIC LANDMARK; CEPHALOMETRY; COMPARATIVE STUDY; COMPUTER INTERFACE; DENTOFACIAL DEFORMITIES; DEVICES; EQUIPMENT DESIGN; ESTHETICS; FEASIBILITY STUDY; FOLLOW UP; MANDIBLE; MAXILLA; PATHOLOGY; PATIENT CARE PLANNING; PROCEDURES; REPRODUCIBILITY; THREE DIMENSIONAL IMAGING; THREE DIMENSIONAL PRINTING; TREATMENT OUTCOME; YOUNG ADULT;

EID: 84889878406     PISSN: 02664356     EISSN: 15321940     Source Type: Journal    
DOI: 10.1016/j.bjoms.2013.03.007     Document Type: Article
Times cited : (155)

References (21)
  • 1
    • 0032948202 scopus 로고    scopus 로고
    • Bimaxillary surgery using an intermediate splint to position the maxilla
    • E. Ellis III Bimaxillary surgery using an intermediate splint to position the maxilla J Oral Maxillofac Surg 57 1999 53 56
    • (1999) J Oral Maxillofac Surg , vol.57 , pp. 53-56
    • Ellis III, E.1
  • 2
    • 59349101866 scopus 로고    scopus 로고
    • How accurate is model planning for orthognathic surgery?
    • A. Sharifi, R. Jones, and A. Ayoub How accurate is model planning for orthognathic surgery? Int J Oral Maxillofac Surg 37 2008 1089 1093
    • (2008) Int J Oral Maxillofac Surg , vol.37 , pp. 1089-1093
    • Sharifi, A.1    Jones, R.2    Ayoub, A.3
  • 3
    • 0028145609 scopus 로고
    • Altered orthognathic surgical sequencing and a modified approach to model surgery
    • D.A. Cottrell, and L.M. Wolford Altered orthognathic surgical sequencing and a modified approach to model surgery J Oral Maxillofac Surg 52 1994 1010 1021
    • (1994) J Oral Maxillofac Surg , vol.52 , pp. 1010-1021
    • Cottrell, D.A.1    Wolford, L.M.2
  • 4
  • 5
    • 0031987045 scopus 로고    scopus 로고
    • Techniques for achieving three-dimensional positioning of the maxilla applied in conjunction with the Gottingen concept
    • R. Schwestka-Polly, D. Kubein-Meesenburg, and H.G. Luhr Techniques for achieving three-dimensional positioning of the maxilla applied in conjunction with the Gottingen concept Int J Adult Orthodon Orthognath Surg 13 1998 248 258
    • (1998) Int J Adult Orthodon Orthognath Surg , vol.13 , pp. 248-258
    • Schwestka-Polly, R.1    Kubein-Meesenburg, D.2    Luhr, H.G.3
  • 6
    • 57649193116 scopus 로고    scopus 로고
    • Comparison of the accuracy of the three-dimensional virtual method and the conventional manual method for model surgery and intermediate wafer fabrication
    • K.G. Song, and S.H. Baek Comparison of the accuracy of the three-dimensional virtual method and the conventional manual method for model surgery and intermediate wafer fabrication Oral Surg Oral Med Oral Pathol Oral Radiol Endod 107 2009 13 21
    • (2009) Oral Surg Oral Med Oral Pathol Oral Radiol Endod , vol.107 , pp. 13-21
    • Song, K.G.1    Baek, S.H.2
  • 7
    • 70749093596 scopus 로고    scopus 로고
    • Virtual model surgery and wafer fabrication for orthognathic surgery
    • J.Y. Choi, K.G. Song, and S.H. Baek Virtual model surgery and wafer fabrication for orthognathic surgery Int J Oral Maxillofac Surg 38 2009 1306 1310
    • (2009) Int J Oral Maxillofac Surg , vol.38 , pp. 1306-1310
    • Choi, J.Y.1    Song, K.G.2    Baek, S.H.3
  • 8
    • 79952216632 scopus 로고    scopus 로고
    • Computer planning and intraoperative navigation in orthognathic surgery
    • R.B. Bell Computer planning and intraoperative navigation in orthognathic surgery J Oral Maxillofac Surg 69 2011 592 605
    • (2011) J Oral Maxillofac Surg , vol.69 , pp. 592-605
    • Bell, R.B.1
  • 9
    • 84856086092 scopus 로고    scopus 로고
    • 3D planning in orthognathic surgery: CAD/CAM surgical splints and prediction of the soft and hard tissues results - Our experience in 16 cases
    • S. Aboul-Hosn Centenero, and F. Hernández-Alfaro 3D planning in orthognathic surgery: CAD/CAM surgical splints and prediction of the soft and hard tissues results - our experience in 16 cases J Craniomaxillofac Surg 40 2012 162 168
    • (2012) J Craniomaxillofac Surg , vol.40 , pp. 162-168
    • Aboul-Hosn Centenero, S.1    Hernández-Alfaro, F.2
  • 10
  • 12
    • 13344260607 scopus 로고    scopus 로고
    • Comparison of the predicted surgical results following virtual planning with those actually achieved following bimaxillary operation of dysgnathia
    • M. Schneider, O. Tzscharnke, and E. Pilling Comparison of the predicted surgical results following virtual planning with those actually achieved following bimaxillary operation of dysgnathia J Craniomaxillofac Surg 33 2005 8 12
    • (2005) J Craniomaxillofac Surg , vol.33 , pp. 8-12
    • Schneider, M.1    Tzscharnke, O.2    Pilling, E.3
  • 13
    • 0026473269 scopus 로고
    • Control of vertical dimension during maxillary orthognathic surgery. A clinical trial comparing internal and external fixed reference points
    • J.W. Ferguson, and N.H. Luyk Control of vertical dimension during maxillary orthognathic surgery. A clinical trial comparing internal and external fixed reference points J Craniomaxillofac Surg 20 1992 333 336
    • (1992) J Craniomaxillofac Surg , vol.20 , pp. 333-336
    • Ferguson, J.W.1    Luyk, N.H.2
  • 14
    • 0031451633 scopus 로고    scopus 로고
    • Individual prostheses and resection templates for mandibular resection and reconstruction
    • H. Eufinger, M. Wehmöller, and E. Machtens Individual prostheses and resection templates for mandibular resection and reconstruction Br J Oral Maxillofac Surg 35 1997 413 418
    • (1997) Br J Oral Maxillofac Surg , vol.35 , pp. 413-418
    • Eufinger, H.1    Wehmöller, M.2    Machtens, E.3
  • 15
    • 70049115189 scopus 로고    scopus 로고
    • Computer simulation and rapid prototyping for the reconstruction of the mandible
    • P. Juergens, Z. Krol, and H.F. Zeilhofer Computer simulation and rapid prototyping for the reconstruction of the mandible J Oral Maxillofac Surg 67 2009 2167 2170
    • (2009) J Oral Maxillofac Surg , vol.67 , pp. 2167-2170
    • Juergens, P.1    Krol, Z.2    Zeilhofer, H.F.3
  • 16
    • 0025013918 scopus 로고
    • Accuracy of model surgery: Evaluation of an old technique and introduction of a new one
    • E. Ellis III Accuracy of model surgery: evaluation of an old technique and introduction of a new one J Oral Maxillofac Surg 48 1990 1161 1167
    • (1990) J Oral Maxillofac Surg , vol.48 , pp. 1161-1167
    • Ellis III, E.1
  • 17
    • 78049235947 scopus 로고    scopus 로고
    • Errors in orthognathic surgery planning: The effect of inaccurate study model orientation
    • J.C. Barbenel, P.E. Paul, and B.S. Khambay Errors in orthognathic surgery planning: the effect of inaccurate study model orientation Int J Oral Maxillofac Surg 39 2010 1103 1108
    • (2010) Int J Oral Maxillofac Surg , vol.39 , pp. 1103-1108
    • Barbenel, J.C.1    Paul, P.E.2    Khambay, B.S.3
  • 18
    • 0031048352 scopus 로고    scopus 로고
    • Two-step repositioning of the maxilla in bimaxillary orthognathic surgery
    • I. Masui, T. Honda, and T. Uji Two-step repositioning of the maxilla in bimaxillary orthognathic surgery Br J Oral Maxillofac Surg 35 1997 64 66
    • (1997) Br J Oral Maxillofac Surg , vol.35 , pp. 64-66
    • Masui, I.1    Honda, T.2    Uji, T.3
  • 19
    • 33846262954 scopus 로고    scopus 로고
    • Accuracy of the computer-aided surgical simulation (CASS) system in the treatment of patients with complex craniomaxillofacial deformity: A pilot study
    • J.J. Xia, J. Gateno, and J.F. Teichgraeber Accuracy of the computer-aided surgical simulation (CASS) system in the treatment of patients with complex craniomaxillofacial deformity: a pilot study J Oral Maxillofac Surg 65 2007 248 254
    • (2007) J Oral Maxillofac Surg , vol.65 , pp. 248-254
    • Xia, J.J.1    Gateno, J.2    Teichgraeber, J.F.3
  • 20
    • 84871232572 scopus 로고    scopus 로고
    • Accuracy of a computer-aided surgical simulation protocol for orthognathic surgery: A prospective multicenter study
    • S.S. Hsu, J. Gateno, and R.B. Bell Accuracy of a computer-aided surgical simulation protocol for orthognathic surgery: a prospective multicenter study J Oral Maxillofac Surg 71 2013 128 142
    • (2013) J Oral Maxillofac Surg , vol.71 , pp. 128-142
    • Hsu, S.S.1    Gateno, J.2    Bell, R.B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.