메뉴 건너뛰기




Volumn 13, Issue 12, 2013, Pages 1934-1939

Primary stability of pedicle screws depends on the screw positioning and alignment

Author keywords

Pedicle screw; Porcine; Pullout; Screw misplacement; Stability

Indexed keywords

ANIMAL EXPERIMENT; ARTICLE; BONE CHARACTERISTICS AND FUNCTIONS; COMPUTED TOMOGRAPHY SCANNER; CONTROLLED STUDY; CORTICAL PERFORATION; IMPLANTATION; LUMBAR SPINE; MATERIALS TESTING; NONHUMAN; ORTHOPEDIC EQUIPMENT; PEDICLE SCREW; PEDICLE SCREW STABILITY; PORCINE MODEL; PRIORITY JOURNAL; SPINE INJURY; SPIRAL COMPUTER ASSISTED TOMOGRAPHY;

EID: 84889684142     PISSN: 15299430     EISSN: 18781632     Source Type: Journal    
DOI: 10.1016/j.spinee.2013.03.046     Document Type: Article
Times cited : (37)

References (21)
  • 1
    • 36148985762 scopus 로고    scopus 로고
    • Electrical conductivity measurement: A new technique to detect iatrogenic initial pedicle perforation
    • C. Bolger, M.O. Kelleher, and L. McEvoy Electrical conductivity measurement: a new technique to detect iatrogenic initial pedicle perforation Eur Spine J 16 2007 1919 1924
    • (2007) Eur Spine J , vol.16 , pp. 1919-1924
    • Bolger, C.1    Kelleher, M.O.2    McEvoy, L.3
  • 2
    • 68349104323 scopus 로고    scopus 로고
    • Image-guided pedicle screw insertion accuracy: A meta-analysis
    • N.F. Tian, and H.Z. Xu Image-guided pedicle screw insertion accuracy: a meta-analysis Int Orthop 33 2009 895 903
    • (2009) Int Orthop , vol.33 , pp. 895-903
    • Tian, N.F.1    Xu, H.Z.2
  • 3
    • 33846683025 scopus 로고    scopus 로고
    • Pedicle screw placement accuracy. A meta-analysis
    • V. Kosmopoulos, and C. Schizas Pedicle screw placement accuracy. A meta-analysis Spine 32 2007 E111 E120
    • (2007) Spine , vol.32
    • Kosmopoulos, V.1    Schizas, C.2
  • 4
    • 80455150078 scopus 로고    scopus 로고
    • Spinal navigation: Standard preoperative versus intraoperative computed tomography data set acquisition for computer-guidance system: Radiological and clinical study in 100 consecutive patients
    • F. Costa, A. Cardia, and A. Ortolina Spinal navigation: standard preoperative versus intraoperative computed tomography data set acquisition for computer-guidance system: radiological and clinical study in 100 consecutive patients Spine 36 2011 2094 2098
    • (2011) Spine , vol.36 , pp. 2094-2098
    • Costa, F.1    Cardia, A.2    Ortolina, A.3
  • 5
    • 0025267440 scopus 로고
    • Accuracy of pedicular screw placement in vivo
    • S.D. Gertzbein, and S.E. Robbins Accuracy of pedicular screw placement in vivo Spine 15 1990 11 14
    • (1990) Spine , vol.15 , pp. 11-14
    • Gertzbein, S.D.1    Robbins, S.E.2
  • 6
    • 0027203876 scopus 로고
    • Pedicle screw pullout strength. Correlation with insertional torque
    • T.A. Zdeblick, D.N. Kunz, M.E. Cooke, and R. McCabe Pedicle screw pullout strength. Correlation with insertional torque Spine 18 1993 1673 1676
    • (1993) Spine , vol.18 , pp. 1673-1676
    • Zdeblick, T.A.1    Kunz, D.N.2    Cooke, M.E.3    McCabe, R.4
  • 7
    • 0024393495 scopus 로고
    • The spinal pedicle screw: Techniques and systems
    • S.I. Esses, and D.A. Bednar The spinal pedicle screw: techniques and systems Orthop Rev 18 1989 676 682
    • (1989) Orthop Rev , vol.18 , pp. 676-682
    • Esses, S.I.1    Bednar, D.A.2
  • 8
    • 0027344944 scopus 로고
    • Biomechanical testing of a new design for Schanz pedicle screws
    • K. Willet, T.C. Hearn, and A.V. Cuncins Biomechanical testing of a new design for Schanz pedicle screws J Orthop Trauma 7 1993 375 380
    • (1993) J Orthop Trauma , vol.7 , pp. 375-380
    • Willet, K.1    Hearn, T.C.2    Cuncins, A.V.3
  • 9
    • 84855645084 scopus 로고    scopus 로고
    • Pedicle screw placement with O-arm and stealth navigation
    • S. Patil, E.M. Lindley, and E.L. Burger Pedicle screw placement with O-arm and stealth navigation Orthopedics 35 2012 e61 e65
    • (2012) Orthopedics , vol.35
    • Patil, S.1    Lindley, E.M.2    Burger, E.L.3
  • 10
    • 84855431289 scopus 로고    scopus 로고
    • The accuracy of intraoperative O-arm images for the assessment of pedicle screw position
    • E.R. Santos, C.G. Ledonio, and C.A. Castro The accuracy of intraoperative O-arm images for the assessment of pedicle screw position Spine 37 2012 E119 E125
    • (2012) Spine , vol.37
    • Santos, E.R.1    Ledonio, C.G.2    Castro, C.A.3
  • 11
    • 0033834616 scopus 로고    scopus 로고
    • Accuracy of pedicle screw insertion with and without computer assistance: A randomised controlled clinical study in 100 consecutive patients
    • T. Laine, T. Lund, and M. Ylikoski Accuracy of pedicle screw insertion with and without computer assistance: a randomised controlled clinical study in 100 consecutive patients Eur Spine J 9 2000 235 240
    • (2000) Eur Spine J , vol.9 , pp. 235-240
    • Laine, T.1    Lund, T.2    Ylikoski, M.3
  • 12
    • 75049085475 scopus 로고    scopus 로고
    • Radiological and clinical outcome of screw placement in adolescent idiopathic scoliosis: Evaluation with low-dose computed tomography
    • K. Abul-Kasim, A. Ohlin, and A. Strombeck Radiological and clinical outcome of screw placement in adolescent idiopathic scoliosis: evaluation with low-dose computed tomography Eur Spine J 19 2010 96 104
    • (2010) Eur Spine J , vol.19 , pp. 96-104
    • Abul-Kasim, K.1    Ohlin, A.2    Strombeck, A.3
  • 13
    • 0030221045 scopus 로고    scopus 로고
    • Factors affecting the pullout strength of cancellous bone screws
    • J.R. Chapman, R.M. Harrington, and K.M. Lee Factors affecting the pullout strength of cancellous bone screws J Biomech Eng 118 1996 391 398
    • (1996) J Biomech Eng , vol.118 , pp. 391-398
    • Chapman, J.R.1    Harrington, R.M.2    Lee, K.M.3
  • 14
    • 33750542318 scopus 로고    scopus 로고
    • A comparison of pullout strength for pedicle screws of different designs: A study using tapped and untapped pilot holes
    • F.M. Pfeiffer, D.L. Abernathie, and D.E. Smith A comparison of pullout strength for pedicle screws of different designs: a study using tapped and untapped pilot holes Spine 31 2006 E867 E870
    • (2006) Spine , vol.31
    • Pfeiffer, F.M.1    Abernathie, D.L.2    Smith, D.E.3
  • 15
    • 84889661504 scopus 로고    scopus 로고
    • A titanium expandable pedicle screw improves initial pullout strength of cancellous bone screws
    • S. Vishnubhotla, W.B. McGarry, A.T. Mahar, and D.E. Gelb A titanium expandable pedicle screw improves initial pullout strength of cancellous bone screws J Biomech Eng 118 1996 391 398
    • (1996) J Biomech Eng , vol.118 , pp. 391-398
    • Vishnubhotla, S.1    McGarry, W.B.2    Mahar, A.T.3    Gelb, D.E.4
  • 16
    • 77951731709 scopus 로고    scopus 로고
    • Quantitative analysis of misplaced pedicle screws in the thoracic spine: How much pullout strength is lost?
    • L.B. Brasiliense, N. Theodore, and B.C. Lazaro Quantitative analysis of misplaced pedicle screws in the thoracic spine: how much pullout strength is lost? J Neurosurg Spine 12 2010 503 508
    • (2010) J Neurosurg Spine , vol.12 , pp. 503-508
    • Brasiliense, L.B.1    Theodore, N.2    Lazaro, B.C.3
  • 17
    • 2242428799 scopus 로고    scopus 로고
    • Definition of pedicle malposition. Primary stability and loosening characteristics of pedicle screws in relation to position: Spongious anchoring, cortical anchoring, perforation and malposition
    • E. Reichle, M. Morlock, K. Sellenschloh, and C. Eggers Definition of pedicle malposition. Primary stability and loosening characteristics of pedicle screws in relation to position: spongious anchoring, cortical anchoring, perforation and malposition Orthopade 31 2002 402 405
    • (2002) Orthopade , vol.31 , pp. 402-405
    • Reichle, E.1    Morlock, M.2    Sellenschloh, K.3    Eggers, C.4
  • 18
    • 0031802589 scopus 로고    scopus 로고
    • Stiffness between different directions of transpedicular screws and vertebra
    • S.S. Wu, W.E. Edwards, and H.A. Yuan Stiffness between different directions of transpedicular screws and vertebra Clin Biomech 13 1 Suppl 1998 S1 S8
    • (1998) Clin Biomech , vol.13 , Issue.1 SUPPL.
    • Wu, S.S.1    Edwards, W.E.2    Yuan, H.A.3
  • 19
    • 0025057930 scopus 로고
    • Vertebral end-plate failure in porcine and bovine models of spinal fracture instrumentation
    • D.G. Allan, G.G. Russell, and M.J. Moreau Vertebral end-plate failure in porcine and bovine models of spinal fracture instrumentation J Orthop Res 8 1990 154 156
    • (1990) J Orthop Res , vol.8 , pp. 154-156
    • Allan, D.G.1    Russell, G.G.2    Moreau, M.J.3
  • 20
    • 84855197631 scopus 로고    scopus 로고
    • Biomechanical in vitro evaluation of the complete porcine spine in comparison with data of the human spine
    • H.J. Wilke, J. Geppert, and A. Kienle Biomechanical in vitro evaluation of the complete porcine spine in comparison with data of the human spine Eur Spine J 20 2011 1859 1868
    • (2011) Eur Spine J , vol.20 , pp. 1859-1868
    • Wilke, H.J.1    Geppert, J.2    Kienle, A.3
  • 21
    • 75049085255 scopus 로고    scopus 로고
    • Anatomy of large animal spines and its comparison to the human spine: A systematic review
    • S.R. Sheng, X.Y. Wang, and H.Z. Xu Anatomy of large animal spines and its comparison to the human spine: a systematic review Eur Spine J 19 2010 46 56
    • (2010) Eur Spine J , vol.19 , pp. 46-56
    • Sheng, S.R.1    Wang, X.Y.2    Xu, H.Z.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.