메뉴 건너뛰기




Volumn 40, Issue 11, 2013, Pages

Adaptation of the CVT algorithm for catheter optimization in high dose rate brachytherapy

Author keywords

CVT; HDR brachytherapy; IPSA; needle planning; optimization

Indexed keywords

CATHETERS; DISEASES; DOSIMETRY; ERRORS; INVERSE PROBLEMS; ONCOLOGY; OPTIMIZATION; RADIOTHERAPY; SIMULATED ANNEALING; UROLOGY; VARIABLE SPEED TRANSMISSIONS;

EID: 84889653621     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.4826335     Document Type: Article
Times cited : (22)

References (37)
  • 1
    • 70350499495 scopus 로고    scopus 로고
    • Comparison of three radiotherapy modalities on biochemical control and overall survival for the treatment of prostate cancer: A systematic review
    • 10.1016/j.radonc.2009.08.033
    • B. R. Pieters, D. Z. de Back, C. C. E. Koning, and A. H. Zwinderman, " Comparison of three radiotherapy modalities on biochemical control and overall survival for the treatment of prostate cancer: A systematic review.," Radiother. Oncol. 93 (2), 168-173 (2009). 10.1016/j.radonc.2009. 08.033
    • (2009) Radiother. Oncol. , vol.93 , Issue.2 , pp. 168-173
    • Pieters, B.R.1    De Back, D.Z.2    Koning, C.C.E.3    Zwinderman, A.H.4
  • 2
    • 59849088946 scopus 로고    scopus 로고
    • An eight-year experience of HDR brachytherapy boost for localized prostate cancer: Biopsy and PSA outcome
    • 10.1016/j.ijrob2008.05.003
    • F. Bachand, A.-G. Martin, L. Beaulieu, F. Harel, and É. Vigneault, " An eight-year experience of HDR brachytherapy boost for localized prostate cancer: Biopsy and PSA outcome.," Int. J. Radiat. Oncol., Biol., Phys. 73 (3), 679-684 (2009). 10.1016/j.ijrobp.2008.05.003
    • (2009) Int. J. Radiat. Oncol., Biol., Phys. , vol.73 , Issue.3 , pp. 679-684
    • Bachand, F.1    Martin, A.-G.2    Beaulieu, L.3    Harel, F.4    Vigneault, É.5
  • 3
    • 78149412003 scopus 로고    scopus 로고
    • The effect of needle number on the quality of high-dose-rate prostate brachytherapy implants
    • 10.1007/s12253-010-9252-z
    • G. Fröhlich, P. Ágoston, J. Lövey, C. Polgár, and T. Major, " The effect of needle number on the quality of high-dose-rate prostate brachytherapy implants.," Pathol. Oncol. Res. 16 (4), 593-599 (2010). 10.1007/s12253-010-9252-z
    • (2010) Pathol. Oncol. Res. , vol.16 , Issue.4 , pp. 593-599
    • Fröhlich, G.1    Ágoston, P.2    Lövey, J.3    Polgár, C.4    Major, T.5
  • 4
    • 5444270917 scopus 로고    scopus 로고
    • High-dose-rate brachytherapy alone versus whole breast radiotherapy with or without tumor bed boost after breast-conserving surgery: Seven-year results of a comparative study
    • 10.1016/j.ijrob2004.05.012
    • C. Polgár, " High-dose-rate brachytherapy alone versus whole breast radiotherapy with or without tumor bed boost after breast-conserving surgery: Seven-year results of a comparative study.," Int. J. Radiat. Oncol., Biol., Phys. 60 (4), 1173-1181 (2004). 10.1016/j.ijrobp.2004.05.012
    • (2004) Int. J. Radiat. Oncol., Biol., Phys. , vol.60 , Issue.4 , pp. 1173-1181
    • Polgár, C.1
  • 5
    • 58149247706 scopus 로고    scopus 로고
    • Dosimetric experience with accelerated partial breast irradiation using image-guided interstitial brachytherapy
    • 10.1016/j.radonc.2007.10.027
    • T. Major, G. Fröhlich, K. Lövey, J. Fodor, and C. Polgár, " Dosimetric experience with accelerated partial breast irradiation using image-guided interstitial brachytherapy.," Radiother. Oncol. 90 (1), 48-55 (2009). 10.1016/j.radonc.2007.10.027
    • (2009) Radiother. Oncol. , vol.90 , Issue.1 , pp. 48-55
    • Major, T.1    Fröhlich, G.2    Lövey, K.3    Fodor, J.4    Polgár, C.5
  • 6
    • 0037963219 scopus 로고    scopus 로고
    • Analysis of interaction between number of implant catheters and dose-volume histograms in prostate high- dose-rate brachytherapy using a computer model
    • 10.1016/S0360-3016(03)00131-7
    • C. Charra-Brunaud, I.-C. J. Hsu, V. Weinberg, and J. Pouliot, " Analysis of interaction between number of implant catheters and dose-volume histograms in prostate high- dose-rate brachytherapy using a computer model.," Int. J. Radiat. Oncol., Biol., Phys. 56 (2), 586-591 (2003). 10.1016/S0360-3016(03)00131-7
    • (2003) Int. J. Radiat. Oncol., Biol., Phys. , vol.56 , Issue.2 , pp. 586-591
    • Charra-Brunaud, C.1    Hsu, I.-C.J.2    Weinberg, V.3    Pouliot, J.4
  • 7
    • 58149116958 scopus 로고    scopus 로고
    • Dosimetric equivalence of nonstandard HDR brachytherapy catheter patterns
    • 10.1118/1.3041166
    • J. A. M. Cunha, I.-C. Hsu, and J. Pouliot, " Dosimetric equivalence of nonstandard HDR brachytherapy catheter patterns.," Med. Phys. 36 (1), 233-239 (2009). 10.1118/1.3041166
    • (2009) Med. Phys. , vol.36 , Issue.1 , pp. 233-239
    • Cunha, J.A.M.1    Hsu, I.-C.2    Pouliot, J.3
  • 8
    • 23744432859 scopus 로고    scopus 로고
    • A new model using number of needles and androgen deprivation to predict chronic urinary toxicity for high or low dose rate prostate brachytherapy
    • 10.1097/01.ju.0000169136.55891.21
    • C. Vargas, " A new model using number of needles and androgen deprivation to predict chronic urinary toxicity for high or low dose rate prostate brachytherapy.," J. Urol. 174 (3), 882-887 (2005). 10.1097/01.ju.0000169136.55891.21
    • (2005) J. Urol. , vol.174 , Issue.3 , pp. 882-887
    • Vargas, C.1
  • 9
    • 84889673471 scopus 로고    scopus 로고
    • Dosimetric analysis of radiation therapy oncology group 0321: The importance of urethral dose
    • in press
    • I.-C. Hsu, " Dosimetric analysis of radiation therapy oncology group 0321: The importance of urethral dose.," Pract. Radiat. Oncol. (in press).
    • Pract. Radiat. Oncol.
    • Hsu, I.-C.1
  • 10
    • 3242678164 scopus 로고    scopus 로고
    • Correlating the degree of needle trauma during prostate brachytherapy and the development of acute urinary toxicity
    • 10.1016/j.ijrob2004.01.041
    • L. Eapen, " Correlating the degree of needle trauma during prostate brachytherapy and the development of acute urinary toxicity.," Int. J. Radiat. Oncol., Biol., Phys. 59 (5), 1392-1394 (2004). 10.1016/j.ijrobp.2004.01. 041
    • (2004) Int. J. Radiat. Oncol., Biol., Phys. , vol.59 , Issue.5 , pp. 1392-1394
    • Eapen, L.1
  • 11
    • 84860894781 scopus 로고    scopus 로고
    • Three-dimensional ultrasound scanning
    • 10.1098/rsfs.2011.0019
    • A. Fenster, G. Parraga, and J. Bax, " Three-dimensional ultrasound scanning.," Interface Focus 1 (4), 503-519 (2011). 10.1098/rsfs.2011.0019
    • (2011) Interface Focus , vol.1 , Issue.4 , pp. 503-519
    • Fenster, A.1    Parraga, G.2    Bax, J.3
  • 12
    • 84871810699 scopus 로고    scopus 로고
    • A phantom study to assess accuracy of needle identification in real-time planning of ultrasound-guided high-dose-rate prostate implants
    • 10.1016/j.brachy.2012.03.002
    • M. Schmid, " A phantom study to assess accuracy of needle identification in real-time planning of ultrasound-guided high-dose-rate prostate implants.," Brachytherapy 12 (1), 56-64 (2013). 10.1016/j.brachy.2012.03.002
    • (2013) Brachytherapy , vol.12 , Issue.1 , pp. 56-64
    • Schmid, M.1
  • 13
    • 38049120408 scopus 로고    scopus 로고
    • Measurement of cranio-caudal catheter displacement between fractions in CT-based HDR brachytherapy of prostate cancer
    • 10.1120/jacmv8i4.2415
    • Y. Kim, I.-C. J. Hsu, and J. Pouliot, " Measurement of cranio-caudal catheter displacement between fractions in CT-based HDR brachytherapy of prostate cancer.," J. Appl. Clin. Med. Phys. 8 (4), 1-13 (2007). 10.1120/jacmp.v8i4.2415
    • (2007) J. Appl. Clin. Med. Phys. , vol.8 , Issue.4 , pp. 1-13
    • Kim, Y.1    Hsu, I.-C.J.2    Pouliot, J.3
  • 14
    • 33645102079 scopus 로고    scopus 로고
    • Robotically assisted prostate brachytherapy with transrectal ultrasound guidance - Phantom experiments
    • 10.1016/j.brachy.2005.10.003
    • G. Fichtinger, " Robotically assisted prostate brachytherapy with transrectal ultrasound guidance-Phantom experiments.," Brachytherapy 5 (1), 14-26 (2006). 10.1016/j.brachy.2005.10.003
    • (2006) Brachytherapy , vol.5 , Issue.1 , pp. 14-26
    • Fichtinger, G.1
  • 15
    • 0033317391 scopus 로고    scopus 로고
    • Centroidal Voronoi tessellations: Applications and algorithms
    • 10.1137/S0036144599352836
    • Q. Du, V. Faber, and M. Gunzburger, " Centroidal Voronoi tessellations: Applications and algorithms.," SIAM Rev. 41 (4), 637-676 (1999). 10.1137/S0036144599352836
    • (1999) SIAM Rev. , vol.41 , Issue.4 , pp. 637-676
    • Du, Q.1    Faber, V.2    Gunzburger, M.3
  • 16
    • 50049089544 scopus 로고    scopus 로고
    • Latinized, improved LHS, and CVT point sets in hypercubes
    • Y. Saka, M. Gunzburger, and J. Burkardt, " Latinized, improved LHS, and CVT point sets in hypercubes.," IJNAM 4 (3-4), 729-743 (2007).
    • (2007) IJNAM , vol.4 , Issue.34 , pp. 729-743
    • Saka, Y.1    Gunzburger, M.2    Burkardt, J.3
  • 17
    • 84867923604 scopus 로고    scopus 로고
    • Constrained CVT meshes and a comparison of triangular mesh generators
    • 10.1016/j.comgeo.2008.04.002
    • H. Nguyen, J. Burkardt, M. Gunzburger, L. Ju, and Y. Saka, " Constrained CVT meshes and a comparison of triangular mesh generators.," Comput. Geom. 42 (1), 1-19 (2009). 10.1016/j.comgeo.2008.04.002
    • (2009) Comput. Geom. , vol.42 , Issue.1 , pp. 1-19
    • Nguyen, H.1    Burkardt, J.2    Gunzburger, M.3    Ju, L.4    Saka, Y.5
  • 18
    • 84881668885 scopus 로고    scopus 로고
    • Parallel algorithms for planar and spherical Delaunay construction with an application to centroidal Voronoi tessellations
    • 10.5194/gmd-6-1353-2013
    • D. W. Jacobsen, M. Gunzburger, T. Ringler, J. Burkardt, and J. Peterson, " Parallel algorithms for planar and spherical Delaunay construction with an application to centroidal Voronoi tessellations.," Geosci. Model Dev. 6 (1), 1353-1365 (2013). 10.5194/gmd-6-1353-2013
    • (2013) Geosci. Model Dev. , vol.6 , Issue.1 , pp. 1353-1365
    • Jacobsen, D.W.1    Gunzburger, M.2    Ringler, T.3    Burkardt, J.4    Peterson, J.5
  • 19
    • 0035010591 scopus 로고    scopus 로고
    • Inverse planning anatomy-based dose optimization for HDR-brachytherapy of the prostate using fast simulated annealing algorithm and dedicated objective function
    • 10.1118/1.1368127
    • E. Lessard and J. Pouliot, " Inverse planning anatomy-based dose optimization for HDR-brachytherapy of the prostate using fast simulated annealing algorithm and dedicated objective function.," Med. Phys. 28 (5), 773-779 (2001). 10.1118/1.1368127
    • (2001) Med. Phys. , vol.28 , Issue.5 , pp. 773-779
    • Lessard, E.1    Pouliot, J.2
  • 20
    • 77957191141 scopus 로고    scopus 로고
    • Phase II trial of combined high-dose-rate brachytherapy and external beam radiotherapy for adenocarcinoma of the prostate: Preliminary results of RTOG 0321
    • 10.1016/j.ijrob2009.08.048
    • I.-C. Hsu, " Phase II trial of combined high-dose-rate brachytherapy and external beam radiotherapy for adenocarcinoma of the prostate: Preliminary results of RTOG 0321.," Int. J. Radiat. Oncol., Biol., Phys. 78 (3), 751-758 (2010). 10.1016/j.ijrobp.2009.08.048
    • (2010) Int. J. Radiat. Oncol., Biol., Phys. , vol.78 , Issue.3 , pp. 751-758
    • Hsu, I.-C.1
  • 21
    • 84855984259 scopus 로고    scopus 로고
    • American brachytherapy society consensus guidelines for high-dose-rate prostate brachytherapy
    • 10.1016/j.brachy.2011.09.008
    • Y. Yamada, " American brachytherapy society consensus guidelines for high-dose-rate prostate brachytherapy.," Brachytherapy 11 (1), 20-32 (2012). 10.1016/j.brachy.2011.09.008
    • (2012) Brachytherapy , vol.11 , Issue.1 , pp. 20-32
    • Yamada, Y.1
  • 22
    • 84872044448 scopus 로고    scopus 로고
    • Prone accelerated partial breast irradiation after breast-conserving surgery: Compliance to the dosimetry requirements of RTOG-0413
    • 10.1016/j.ijrob2012.01.055
    • B. Wen, " Prone accelerated partial breast irradiation after breast-conserving surgery: Compliance to the dosimetry requirements of RTOG-0413.," Int. J. Radiat. Oncol., Biol., Phys. 84 (4), 910-916 (2012). 10.1016/j.ijrobp.2012.01.055
    • (2012) Int. J. Radiat. Oncol., Biol., Phys. , vol.84 , Issue.4 , pp. 910-916
    • Wen, B.1
  • 23
    • 67649519727 scopus 로고    scopus 로고
    • Accelerated partial breast irradiation consensus statement from the American Society for Radiation Oncology (ASTRO)
    • 10.1016/j.ijrob2009.02.031
    • B. D. Smith, " Accelerated partial breast irradiation consensus statement from the American Society for Radiation Oncology (ASTRO).," Int. J. Radiat. Oncol., Biol., Phys. 74 (4), 987-1001 (2009). 10.1016/j.ijrobp.2009. 02.031
    • (2009) Int. J. Radiat. Oncol., Biol., Phys. , vol.74 , Issue.4 , pp. 987-1001
    • Smith, B.D.1
  • 24
    • 1142304255 scopus 로고    scopus 로고
    • Update of AAPM Task Group No. 43 Report: A revised AAPM protocol for brachytherapy dose calculations
    • 10.1118/1.1646040
    • M. J. Rivard, " Update of AAPM Task Group No. 43 Report: A revised AAPM protocol for brachytherapy dose calculations.," Med. Phys. 31 (3), 633-674 (2004). 10.1118/1.1646040
    • (2004) Med. Phys. , vol.31 , Issue.3 , pp. 633-674
    • Rivard, M.J.1
  • 25
    • 3042658240 scopus 로고    scopus 로고
    • Inverse planning for HDR prostate brachytherapy used to boost dominant intraprostatic lesions defined by magnetic resonance spectroscopy imaging
    • 10.1016/j.ijrob2004.02.055
    • J. Pouliot, Y. Kim, E. Lessard, I.-C. Hsu, D. B. Vigneron, and J. Kurhanewicz, " Inverse planning for HDR prostate brachytherapy used to boost dominant intraprostatic lesions defined by magnetic resonance spectroscopy imaging.," Int. J. Radiat. Oncol., Biol., Phys. 59 (4), 1196-1207 (2004). 10.1016/j.ijrobp.2004.02.055
    • (2004) Int. J. Radiat. Oncol., Biol., Phys. , vol.59 , Issue.4 , pp. 1196-1207
    • Pouliot, J.1    Kim, Y.2    Lessard, E.3    Hsu, I.-C.4    Vigneron, D.B.5    Kurhanewicz, J.6
  • 26
    • 8144226372 scopus 로고    scopus 로고
    • Comparison of inverse planning simulated annealing and geometrical optimization for prostate high-dose-rate brachytherapy
    • 10.1016/j.brachy.2004.05.007
    • I.-C. J. Hsu, E. Lessard, V. Weinberg, and J. Pouliot, " Comparison of inverse planning simulated annealing and geometrical optimization for prostate high-dose-rate brachytherapy.," Brachytherapy 3 (3), 147-152 (2004). 10.1016/j.brachy.2004.05.007
    • (2004) Brachytherapy , vol.3 , Issue.3 , pp. 147-152
    • Hsu, I.-C.J.1    Lessard, E.2    Weinberg, V.3    Pouliot, J.4
  • 27
    • 0036718529 scopus 로고    scopus 로고
    • Early clinical experience with anatomy-based inverse planning dose optimization for high-dose-rate boost of the prostate
    • 10.1016/S0360-3016(02)02897-3
    • B. Lachance, " Early clinical experience with anatomy-based inverse planning dose optimization for high-dose-rate boost of the prostate.," Int. J. Radiat. Oncol., Biol., Phys. 54 (1), 86-100 (2002). 10.1016/S0360-3016(02) 02897-3
    • (2002) Int. J. Radiat. Oncol., Biol., Phys. , vol.54 , Issue.1 , pp. 86-100
    • Lachance, B.1
  • 28
    • 84864186421 scopus 로고    scopus 로고
    • NPIP: A skew line needle configuration optimization system for HDR brachytherapy
    • 10.1118/1.4728226
    • T. Siauw, " NPIP: A skew line needle configuration optimization system for HDR brachytherapy.," Med. Phys. 39 (7), 4339-4346 (2012). 10.1118/1.4728226
    • (2012) Med. Phys. , vol.39 , Issue.7 , pp. 4339-4346
    • Siauw, T.1
  • 29
    • 84889690668 scopus 로고    scopus 로고
    • Catheters optimization within inverse planning simulated annealing for high-dose-rate brachytherapy
    • 10.1016/j.brachy.2008.02.236
    • G. Ayotte, D. Michel, E. Lessard, J. Pouliot, and L. Beaulieu, " Catheters optimization within inverse planning simulated annealing for high-dose-rate brachytherapy.," Brachytherapy 7 (2), 168 (2008). 10.1016/j.brachy.2008.02.236
    • (2008) Brachytherapy , vol.7 , Issue.2 , pp. 168
    • Ayotte, G.1    Michel, D.2    Lessard, E.3    Pouliot, J.4    Beaulieu, L.5
  • 30
    • 84873696837 scopus 로고    scopus 로고
    • Mixed integer programming improves comprehensibility and plan quality in inverse optimization of prostate HDR brachytherapy
    • 10.1088/0031-9155/58/4/1041
    • B. L. Gorissen, D. den Hertog, and A. L. Hoffmann, " Mixed integer programming improves comprehensibility and plan quality in inverse optimization of prostate HDR brachytherapy.," Phys. Med. Biol. 58 (4), 1041-1057 (2013). 10.1088/0031-9155/58/4/1041
    • (2013) Phys. Med. Biol. , vol.58 , Issue.4 , pp. 1041-1057
    • Gorissen, B.L.1    Den Hertog, D.2    Hoffmann, A.L.3
  • 31
    • 84955183290 scopus 로고    scopus 로고
    • Heuristics for integrated optimization of catheter positioning and dwell time distribution in prostate HDR brachytherapy
    • 10.1007/s10479-013-1448-7
    • Å. Holm, Å. C. Tedgren, and T. Larsson, " Heuristics for integrated optimization of catheter positioning and dwell time distribution in prostate HDR brachytherapy.," Ann. Operat. Res. 1-21 (2013). 10.1007/s10479-013-1448-7
    • (2013) Ann. Operat. Res. , pp. 1-21
    • Holm, Å.1    Tedgren, Å.C.2    Larsson, T.3
  • 32
    • 70350488183 scopus 로고    scopus 로고
    • HIPO: A hybrid inverse treatment planning optimization algorithm in HDR brachytherapy
    • 10.1016/S0167-8140(05)81018-7
    • A. Karabis, S. Giannouli, and D. Baltas, " HIPO: A hybrid inverse treatment planning optimization algorithm in HDR brachytherapy.," Radiother. Oncol. 76 (Suppl 2), S29 (2005). 10.1016/S0167-8140(05)81018-7
    • (2005) Radiother. Oncol. , vol.76 , Issue.SUPPL. 2 , pp. 29
    • Karabis, A.1    Giannouli, S.2    Baltas, D.3
  • 33
    • 80052311040 scopus 로고    scopus 로고
    • Dosimetric characteristics of accelerated partial breast irradiation with CT image-based multicatheter interstitial brachytherapy: A single institution's experience
    • 10.1016/j.brachy.2010.12.006
    • T. Major, C. Polgár, K. Lövey, and G. Fröhlich, " Dosimetric characteristics of accelerated partial breast irradiation with CT image-based multicatheter interstitial brachytherapy: A single institution's experience.," Brachytherapy 10 (5), 421-426 (2011). 10.1016/j.brachy.2010. 12.006
    • (2011) Brachytherapy , vol.10 , Issue.5 , pp. 421-426
    • Major, T.1    Polgár, C.2    Lövey, K.3    Fröhlich, G.4
  • 34
    • 77954957034 scopus 로고    scopus 로고
    • Prostate gland edema after single-fraction high-dose rate brachytherapy before external beam radiation therapy
    • 10.1016/j.brachy.2009.09.003
    • F. L. Cury, M. Duclos, A. Aprikian, H. Patrocinio, and L. Souhami, " Prostate gland edema after single-fraction high-dose rate brachytherapy before external beam radiation therapy.," Brachytherapy 9 (3), 208-212 (2010). 10.1016/j.brachy.2009.09.003
    • (2010) Brachytherapy , vol.9 , Issue.3 , pp. 208-212
    • Cury, F.L.1    Duclos, M.2    Aprikian, A.3    Patrocinio, H.4    Souhami, L.5
  • 36
    • 84889672857 scopus 로고    scopus 로고
    • Dosimetry improvement and needle number reduction in prostate brachytherapy using electromagnetically guided needle placement
    • 10.1118/1.4734661
    • J. Zhou, E. Sebastian, and D. Yan, " Dosimetry improvement and needle number reduction in prostate brachytherapy using electromagnetically guided needle placement.," Med. Phys. 39 (6), 3611 (2012). 10.1118/1.4734661
    • (2012) Med. Phys. , vol.39 , Issue.6 , pp. 3611
    • Zhou, J.1    Sebastian, E.2    Yan, D.3
  • 37
    • 70350721373 scopus 로고    scopus 로고
    • Three-dimensional ultrasound system for guided breast brachytherapy
    • 10.1118/1.3243865
    • P. De Jean, L. Beaulieu, and A. Fenster, " Three-dimensional ultrasound system for guided breast brachytherapy.," Med. Phys. 36 (11), 5099-5106 (2009). 10.1118/1.3243865
    • (2009) Med. Phys. , vol.36 , Issue.11 , pp. 5099-5106
    • Jean, P.D.1    Beaulieu, L.2    Fenster, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.