메뉴 건너뛰기




Volumn 192, Issue , 2014, Pages 634-641

A highly sensitive electrochemical sensor for simultaneous voltammetric determination of noradrenaline, acetaminophen, xanthine and caffeine based on a flavonoid nanostructured modified glassy carbon electrode

Author keywords

Acetaminophen; Caffeine; Electrochemical impedance spectroscopy; Nanostructured sensor; Noradrenaline; Xanthine

Indexed keywords

ACETAMINOPHEN; MODIFIED GLASSY CARBON ELECTRODE; NANOSTRUCTURED SENSORS; NORADRENALINE; PHOSPHATE BUFFER SOLUTIONS; STANDARD ADDITION METHOD; VOLTAMMETRIC DETERMINATION; XANTHINE;

EID: 84889650213     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2013.11.006     Document Type: Article
Times cited : (119)

References (45)
  • 1
    • 0032926448 scopus 로고    scopus 로고
    • Periaqueductal gray stimulation-induced inhibition of nociceptive dorsal horn neurons in rats is associated with the release of norepinephrine, serotonin, and amino acids
    • M. Cui, Y. Feng, D.J. McAdoo, and W.D. Willis Periaqueductal gray stimulation-induced inhibition of nociceptive dorsal horn neurons in rats is associated with the release of norepinephrine, serotonin, and amino acids J. Pharmacol. Exp. Ther. 289 1999 868 876 (Pubitemid 29191244)
    • (1999) Journal of Pharmacology and Experimental Therapeutics , vol.289 , Issue.2 , pp. 868-876
    • Cui, M.1    Feng, Y.2    McAdoo, D.J.3    Willis, W.D.4
  • 3
    • 0035132183 scopus 로고    scopus 로고
    • Paracetamol (acetaminophen)-induced toxicity: Molecular and biochemical mechanisms, analogues and protective approaches
    • J.G.M. Bessems, and N.P.E. Vermeulen Paracetamol (acetaminophen)-induced toxicity: molecular and biochemical mechanisms, analogues and protective approaches Crit. Rev. Toxicol. 31 2001 55 138 (Pubitemid 32157805)
    • (2001) Critical Reviews in Toxicology , vol.31 , Issue.1 , pp. 55-138
    • Bessems, J.G.M.1    Vermeulen, N.P.E.2
  • 4
    • 84984580675 scopus 로고    scopus 로고
    • Acetaminophen-induced liver damage in mice: Effects of some medicinal plants on the oxidative defense system
    • DOI 10.1016/j.etp.2007.10.003, PII S094029930700084X
    • M.T. Olaleye, and B.T.J. Rocha Acetaminophen-induced liver damage in mice: effects of some medicinal plants on the oxidative defence system Exp. Toxicol. Pathol. 59 2008 319 327 (Pubitemid 351288524)
    • (2008) Experimental and Toxicologic Pathology , vol.59 , Issue.5 , pp. 319-327
    • Olaleye, M.T.1    Rocha B.T.Joao2
  • 5
    • 0031773510 scopus 로고    scopus 로고
    • Differential chemoprotection against acetaminophen-induced hepatotoxicity by latentiated L-cysteines
    • DOI 10.1021/tx980027k
    • J.C. Roberts, H.L. Phaneuf, J.G. Szakacs, R.T. Zera, J.G. Lamb, and M.R. Franklin Differential chemoprotection against acetaminophen-induced hepatotoxicity by latentiated l-cysteines Chem. Res. Toxicol. 11 1998 1274 1282 (Pubitemid 28531547)
    • (1998) Chemical Research in Toxicology , vol.11 , Issue.11 , pp. 1274-1282
    • Roberts, J.C.1    Phaneuf, H.L.2    Szakacs, J.G.3    Zera, R.T.4    Lamb, J.G.5    Franklin, M.R.6
  • 6
    • 54249105259 scopus 로고    scopus 로고
    • Acetaminophen-induced nephrotoxicity: Pathophysiology, clinical manifestations, and management
    • M. Mazer, and J. Perrone Acetaminophen-induced nephrotoxicity: pathophysiology, clinical manifestations, and management J. Med. Toxicol. 4 2008 2 6
    • (2008) J. Med. Toxicol. , vol.4 , pp. 2-6
    • Mazer, M.1    Perrone, J.2
  • 8
    • 0036301429 scopus 로고    scopus 로고
    • Anodic voltammetry of xanthine, theophylline, theobromine and caffeine at conductive diamond electrodes and its analytical application
    • N. Spataru, B.V. Sarada, D.A. Tryk, and A. Fujishima Anodic voltammetry of xanthine, theophylline, theobromine and caffeine at conductive diamond electrodes and its analytical application Electroanalysis 14 2002 721 728
    • (2002) Electroanalysis , vol.14 , pp. 721-728
    • Spataru, N.1    Sarada, B.V.2    Tryk, D.A.3    Fujishima, A.4
  • 9
    • 22244434946 scopus 로고    scopus 로고
    • Determination of caffeine and its metabolites in urine by capillary electrophoresis-mass spectrometry
    • DOI 10.1002/elps.200500231
    • U.L.P. Okonny, S.X. Wang, R.J. Stubbs, and N.A. Guzman Determination of caffeine and its metabolites in urine by capillary electrophoresis-mass spectrometry Electrophoresis 26 2005 2652 2663 (Pubitemid 40990611)
    • (2005) Electrophoresis , vol.26 , Issue.13 , pp. 2652-2663
    • Peri-Okonny, U.L.1    Wang, S.X.2    Stubbs, R.J.3    Guzman, N.A.4
  • 10
    • 58149510329 scopus 로고    scopus 로고
    • Identification of green tea's (Camellia sinensis (L.)) quality level according to measurement of main catechins and caffeine contents by HPLC and support vector classification pattern recognition
    • Q. Chen, Z. Guo, and J. Zhao Identification of green tea's (Camellia sinensis (L.)) quality level according to measurement of main catechins and caffeine contents by HPLC and support vector classification pattern recognition J. Pharm. Biomed. Anal. 48 2008 1321 1325
    • (2008) J. Pharm. Biomed. Anal. , vol.48 , pp. 1321-1325
    • Chen, Q.1    Guo, Z.2    Zhao, J.3
  • 12
    • 22444448412 scopus 로고    scopus 로고
    • Fatal caffeine overdose: Two case reports
    • DOI 10.1016/j.forsciint.2005.04.016, PII S0379073805002057, 2004 Joint Meeting of SOFT and TIAFT
    • S. Kerrigan, and T. Lindsey Fatal caffeine overdose: two case reports Forensic Sci. Int. 153 2005 67 69 (Pubitemid 41008654)
    • (2005) Forensic Science International , vol.153 , Issue.1 , pp. 67-69
    • Kerrigan, S.1    Lindsey, T.2
  • 14
    • 0242684709 scopus 로고    scopus 로고
    • Simultaneous determination of norepinephrine, serotonin, and 5-hydroxyindole-3-acetic acid in microdialysis samples from rat brain by microbore column liquid chromatography with fluorescence detection following derivatization with benzylamine
    • DOI 10.1016/S0003-2697(02)00435-9, PII S0003269702004359
    • T. Yoshitake, K. Fujino, J. Kehr, J. Ishida, H. Nohta, and M. Yamaguchi Simultaneous determination of norepinephrine, serotonin, and 5-hydroxyindole-3-acetic acid in microdialysis samples from rat brain by microbore column liquid chromatography with fluorescence detection following derivatization with benzylamine Anal. Biochem. 312 2003 125 133 (Pubitemid 36151122)
    • (2003) Analytical Biochemistry , vol.312 , Issue.2 , pp. 125-133
    • Yoshitake, T.1    Fujino, K.2    Kehr, J.3    Ishida, J.4    Nohta, H.5    Yamaguchi, M.6
  • 15
    • 0034621353 scopus 로고    scopus 로고
    • Simultaneous kinetic spectrophotometric determination of acetaminophen and phenobarbital by artificial neural networks and partial least squares
    • DOI 10.1016/S0003-2670(00)00978-8, PII S0003267000009788
    • Y. Ni, C. Liu, and S. Kokot Simultaneous kinetic spectrophotometric determination of acetaminophen and phenobarbital by artificial neural networks and partial least squares Anal. Chim. Acta 419 2000 185 196 (Pubitemid 30616383)
    • (2000) Analytica Chimica Acta , vol.419 , Issue.2 , pp. 185-196
    • Ni, Y.1    Liu, C.2    Kokot, S.3
  • 16
    • 33846982585 scopus 로고    scopus 로고
    • Simultaneous determination of allantoin, hypoxanthine, xanthine, anduric acid in serum/plasma by CE
    • E. Causse, A. Pradelles, B. Dirat, A. Negre-Salvayre, R. Salvayre, and F. Couderc Simultaneous determination of allantoin, hypoxanthine, xanthine, anduric acid in serum/plasma by CE Electrophoresis 28 2007 381 387
    • (2007) Electrophoresis , vol.28 , pp. 381-387
    • Causse, E.1    Pradelles, A.2    Dirat, B.3    Negre-Salvayre, A.4    Salvayre, R.5    Couderc, F.6
  • 17
    • 33847306339 scopus 로고    scopus 로고
    • Simultaneous determination of paracetamol, caffeine and propyphenazone in ternary mixtures by micellar electrokinetic capillary chromatography
    • DOI 10.1016/j.jchromb.2006.09.036, PII S1570023206008063
    • D. Emre, and N. Ozaltin Simultaneous determination of paracetamol, caffeine and propyphenazone in ternary mixtures by micellar electrokinetic capillary chromatography J. Chromatogr. B 847 2007 126 132 (Pubitemid 46331019)
    • (2007) Journal of Chromatography B: Analytical Technologies in the Biomedical and Life Sciences , vol.847 , Issue.2 , pp. 126-132
    • Emre, D.1    Ozaltin, N.2
  • 18
    • 80053569789 scopus 로고    scopus 로고
    • Selective voltammetric determination of norepinephrine in the presence of acetaminophen and folic acid at a modified carbon nanotube paste electrode
    • H. Beitollahi, and I. Sheikhshoaie Selective voltammetric determination of norepinephrine in the presence of acetaminophen and folic acid at a modified carbon nanotube paste electrode J. Electroanal. Chem. 661 2011 336 342
    • (2011) J. Electroanal. Chem. , vol.661 , pp. 336-342
    • Beitollahi, H.1    Sheikhshoaie, I.2
  • 19
    • 33845413015 scopus 로고    scopus 로고
    • Carbon nanotube based aliphatic hydrocarbon sensor
    • DOI 10.1016/j.bios.2006.02.023, PII S0956566306000893
    • S.K. Padigi, R.K.K. Reddy, and S. Prasad Carbon nanotube based aliphatic hydrocarbon sensor Biosens. Bioelectron. 22 2007 829 837 (Pubitemid 44894857)
    • (2007) Biosensors and Bioelectronics , vol.22 , Issue.6 , pp. 829-837
    • Padigi, S.K.1    Reddy, R.K.K.2    Prasad, S.3
  • 20
    • 0342819025 scopus 로고
    • Helical microtubules of graphitic carbon
    • S. Iijima Helical microtubules of graphitic carbon Nature 354 1991 56 58 (Pubitemid 21896780)
    • (1991) Nature , vol.354 , Issue.6348 , pp. 56-58
    • Iijima, S.1
  • 21
    • 34547957791 scopus 로고    scopus 로고
    • Electrochemical chlorine sensor with multi-walled carbon nanotubes as electrocatalysts
    • DOI 10.1016/j.elecom.2007.07.015, PII S1388248107002998
    • G. Sun, S. Liu, K. Hua, H. Lv, L. Huang, and Y. Wang Electrochemical chlorine sensor with multi-walled carbon nanotubes as electrocatalysts Electrochem. Commun. 9 2007 2436 2440 (Pubitemid 47268885)
    • (2007) Electrochemistry Communications , vol.9 , Issue.9 , pp. 2436-2440
    • Sun, G.1    Liu, S.2    Hua, K.3    Lv, X.4    Huang, L.5    Wang, Y.6
  • 22
    • 0035281868 scopus 로고    scopus 로고
    • Investigation of the electrochemical and electrocatalytic behavior of single-wall carbon nanotube film on a glassy carbon electrode
    • DOI 10.1021/ac000967l
    • H. Luo, Z. Shi, N. Li, Z. Gu, and Q. Zhuang Investigation of the electrochemical and electrocatalytic behaviour of single-wall carbon nanotube film on a glassy carbon electrode Anal. Chem. 73 2001 915 920 (Pubitemid 32204905)
    • (2001) Analytical Chemistry , vol.73 , Issue.5 , pp. 915-920
    • Luo, H.1    Shi, Z.2    Li, N.3    Gu, Z.4    Zhuang, Q.5
  • 23
    • 0001837555 scopus 로고    scopus 로고
    • Fast Electron Transfer Kinetics on Multiwalled Carbon Nanotube Microbundle Electrodes
    • DOI 10.1021/nl005521z
    • J.M. Nugent, K.S.V. Santhanam, A. Rubio, and P.M. Ajayan Fast electron transfer kinetics on multiwalled carbon nanotube micro bundle electrodes Nano Lett. 1 2001 87 91 (Pubitemid 33673316)
    • (2001) Nano Letters , vol.1 , Issue.2 , pp. 87-91
    • Nugent, J.M.1    Santhanam, K.S.V.2    Rubio, A.3    Ajayan, P.M.4
  • 24
    • 65549113067 scopus 로고    scopus 로고
    • Ni(II)-quercetin complex modified multiwall carbon nanotube ionic liquid paste electrode and its electrocatalytic activity toward the oxidation of glucose
    • L. Zheng, J.Q. Zhang, and J.F. Song Ni(II)-quercetin complex modified multiwall carbon nanotube ionic liquid paste electrode and its electrocatalytic activity toward the oxidation of glucose Electrochim. Acta 54 2009 4559 4565
    • (2009) Electrochim. Acta , vol.54 , pp. 4559-4565
    • Zheng, L.1    Zhang, J.Q.2    Song, J.F.3
  • 25
    • 84861194830 scopus 로고    scopus 로고
    • Electrodeposition of quercetin at a multi-walled carbon nanotubes modified glassy carbon electrode as a novel and efficient voltammetric sensor for simultaneous determination of levodopa, uric acid and tyramine
    • J.B. Raoof, R. Ojani, M. Amiri-Aref, and M. Baghayeri Electrodeposition of quercetin at a multi-walled carbon nanotubes modified glassy carbon electrode as a novel and efficient voltammetric sensor for simultaneous determination of levodopa, uric acid and tyramine Sens. Actuators B 166-167 2012 508 518
    • (2012) Sens. Actuators B , vol.166-167 , pp. 508-518
    • Raoof, J.B.1    Ojani, R.2    Amiri-Aref, M.3    Baghayeri, M.4
  • 27
    • 0034073313 scopus 로고    scopus 로고
    • Measurement of food flavonoids by high-performance liquid chromatography: A review
    • DOI 10.1021/jf990872o
    • H.M. Merken, and G.R. Beecher Measurement of food flavonoids by high-performance liquid chromatography: a review J. Agric. Food Chem. 48 2000 577 599 (Pubitemid 30193975)
    • (2000) Journal of Agricultural and Food Chemistry , vol.48 , Issue.3 , pp. 577-599
    • Merken, H.M.1    Beecher, G.R.2
  • 28
    • 0031053275 scopus 로고    scopus 로고
    • Analytical chemistry of fruit bioflavonoids: A review
    • K. Robards, and M. Antolovich Analytical chemistry of fruit bioflavonoids: a review Analyst 122 1997 11 34
    • (1997) Analyst , vol.122 , pp. 11-34
    • Robards, K.1    Antolovich, M.2
  • 29
    • 79952310924 scopus 로고    scopus 로고
    • Sensitive electrochemical determination of luteolin in peanut hulls using multi-walled carbon nanotubes modified electrode
    • D. Zhao, X. Zhang, L. Feng, Q. Qi, and S. Wang Sensitive electrochemical determination of luteolin in peanut hulls using multi-walled carbon nanotubes modified electrode Food Chem. 127 2011 694 698
    • (2011) Food Chem. , vol.127 , pp. 694-698
    • Zhao, D.1    Zhang, X.2    Feng, L.3    Qi, Q.4    Wang, S.5
  • 30
    • 45749128579 scopus 로고    scopus 로고
    • Electrochemical oxidation of luteolin at a glassy carbon electrode and its application in pharmaceutical analysis
    • DOI 10.1248/cpb.56.745
    • A. Liu, S. Zhang, L. Huang, Y. Cao, H. Yao, W. Chen, and X. Lin Electrochemical oxidation of luteolin at a glassy carbon electrode and its application in pharmaceutical analysis Chem. Pharm. Bull. 56 2008 745 748 (Pubitemid 351872237)
    • (2008) Chemical and Pharmaceutical Bulletin , vol.56 , Issue.6 , pp. 745-748
    • Liu, A.1    Zhang, S.2    Huang, L.3    Cao, Y.4    Yao, H.5    Chen, W.6    Lin, X.7
  • 31
    • 0345327818 scopus 로고    scopus 로고
    • Preparation of polypyrrole/ferrocyanide films modified carbon paste electrode and its application on the electrocatalytic determination of ascorbic acid
    • J.B. Raoof, R. Ojani, and S. Rashid-Nadimi Preparation of polypyrrole/ferrocyanide films modified carbon paste electrode and its application on the electrocatalytic determination of ascorbic acid Electrochim. Acta 49 2004 271 280
    • (2004) Electrochim. Acta , vol.49 , pp. 271-280
    • Raoof, J.B.1    Ojani, R.2    Rashid-Nadimi, S.3
  • 32
    • 34748814465 scopus 로고    scopus 로고
    • Electrochemical analysis of d-penicillamine using a carbon paste electrode modified with ferrocene carboxylic acid
    • J.B. Raoof, R. Ojani, and F. Chekin Electrochemical analysis of d-penicillamine using a carbon paste electrode modified with ferrocene carboxylic acid Electroanalysis 19 2007 1883 1889
    • (2007) Electroanalysis , vol.19 , pp. 1883-1889
    • Raoof, J.B.1    Ojani, R.2    Chekin, F.3
  • 33
  • 34
    • 77952106773 scopus 로고    scopus 로고
    • A novel sensor for cephalosporins based on electrocatalytic oxidation by poly(o-anisidine)/SDS/Ni modified carbon paste electrode
    • R. Ojani, J.B. Raoof, and S. Zamani A novel sensor for cephalosporins based on electrocatalytic oxidation by poly(o-anisidine)/SDS/Ni modified carbon paste electrode Talanta 81 2010 1522 1528
    • (2010) Talanta , vol.81 , pp. 1522-1528
    • Ojani, R.1    Raoof, J.B.2    Zamani, S.3
  • 35
    • 77952197601 scopus 로고    scopus 로고
    • Simultaneous voltammetric determination of ascorbic acid and dopamine at the surface of electrodes modified with self-assembled gold nanoparticle films
    • J.B. Raoof, A. Kiani, R. Ojani, R. Valiollahi, and S. Rashid-Nadimi Simultaneous voltammetric determination of ascorbic acid and dopamine at the surface of electrodes modified with self-assembled gold nanoparticle films J. Solid State Electrochem. 4 2010 1171 1176
    • (2010) J. Solid State Electrochem. , vol.4 , pp. 1171-1176
    • Raoof, J.B.1    Kiani, A.2    Ojani, R.3    Valiollahi, R.4    Rashid-Nadimi, S.5
  • 36
    • 84877909629 scopus 로고    scopus 로고
    • Electrocatalytic oxidation and selective determination of an opioid analgesic methadone in the presence of acetaminophen at a glassy carbon electrode modified with functionalized multi-walled carbon nanotubes: Application for human urine, saliva and pharmaceutical samples analysis
    • M. Amiri-Aref, J.B. Raoof, and R. Ojani Electrocatalytic oxidation and selective determination of an opioid analgesic methadone in the presence of acetaminophen at a glassy carbon electrode modified with functionalized multi-walled carbon nanotubes: application for human urine, saliva and pharmaceutical samples analysis Colloid Surf. B 109 2013 287 293
    • (2013) Colloid Surf. B , vol.109 , pp. 287-293
    • Amiri-Aref, M.1    Raoof, J.B.2    Ojani, R.3
  • 37
    • 0035057119 scopus 로고    scopus 로고
    • Chemical modification of the inner walls of carbon nanotubes by HNO oxidation
    • T. Kyotani, S. Nakazaki, W. Xu, and A. Tomita Chemical modification of the inner walls of carbon nanotubes by HNO oxidation Carbon 39 2001 771 785
    • (2001) Carbon , vol.39 , pp. 771-785
    • Kyotani, T.1    Nakazaki, S.2    Xu, W.3    Tomita, A.4
  • 38
    • 2342475721 scopus 로고    scopus 로고
    • On the nature of basic sites on carbon surfaces: An overview
    • M.A. Montes-Moran, D. Suarez, J.A. Menendez, and E. Fuente On the nature of basic sites on carbon surfaces: an overview Carbon 42 2004 1219 1225
    • (2004) Carbon , vol.42 , pp. 1219-1225
    • Montes-Moran, M.A.1    Suarez, D.2    Menendez, J.A.3    Fuente, E.4
  • 39
    • 0344089039 scopus 로고    scopus 로고
    • A dsorption of cadmium (II) from aqueous solution by surface oxidized carbon nanotubes
    • Y. Li, S. Wang, Z. Luan, J. Ding, C. Xu, and D. Wu A dsorption of cadmium (II) from aqueous solution by surface oxidized carbon nanotubes Carbon 41 2003 1057 1062
    • (2003) Carbon , vol.41 , pp. 1057-1062
    • Li, Y.1    Wang, S.2    Luan, Z.3    Ding, J.4    Xu, C.5    Wu, D.6
  • 40
    • 73149122926 scopus 로고    scopus 로고
    • Simultaneous determination of ascorbic acid, adrenaline and uric acid at a hematoxylin multi-wall carbon nanotube modified glassy carbon electrode
    • H.R. Zare, and N. Nasirizadeh Simultaneous determination of ascorbic acid, adrenaline and uric acid at a hematoxylin multi-wall carbon nanotube modified glassy carbon electrode Sens. Actuators B 143 2010 666 672
    • (2010) Sens. Actuators B , vol.143 , pp. 666-672
    • Zare, H.R.1    Nasirizadeh, N.2
  • 41
    • 20444442041 scopus 로고    scopus 로고
    • Electrochemical oxidation of rutin
    • DOI 10.1002/elan.200403100
    • M.E. Ghica, and A.M.O. Brett Electrochemical oxidation of rutin Electroanalysis 17 2005 313 318 (Pubitemid 40831212)
    • (2005) Electroanalysis , vol.17 , Issue.4 , pp. 313-318
    • Ghica, M.-E.1    Brett, A.M.O.2
  • 42
    • 3142732010 scopus 로고    scopus 로고
    • Catechin electrochemical oxidation mechanisms
    • DOI 10.1016/j.aca.2004.05.038, PII S0003267004006506
    • P. Janeiro, and A.M.O. Brett Catechin electrochemical oxidation mechanisms Anal. Chim. Acta 518 2004 109 115 (Pubitemid 38917061)
    • (2004) Analytica Chimica Acta , vol.518 , Issue.1-2 , pp. 109-115
    • Janeiro, P.1    Oliveira Brett, A.M.2
  • 43
    • 49249148639 scopus 로고
    • General expression of the linear potential sweep voltammogram in the case of diffusionless electrochemical systems
    • E. Lavion General expression of the linear potential sweep voltammogram in the case of diffusionless electrochemical systems J. Electroanal. Chem. 101 1979 19 28
    • (1979) J. Electroanal. Chem. , vol.101 , pp. 19-28
    • Lavion, E.1
  • 44
    • 0001247396 scopus 로고
    • Preliminary determinations of electron transfer kinetics involving ferrocene covalently attached to a platinum surface
    • M. Sharp, M. Petersson, and K. Edstrom Preliminary determinations of electron transfer kinetics involving ferrocene covalently attached to a platinum surface J. Electroanal. Chem. 95 1979 123 130
    • (1979) J. Electroanal. Chem. , vol.95 , pp. 123-130
    • Sharp, M.1    Petersson, M.2    Edstrom, K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.