메뉴 건너뛰기




Volumn 24, Issue 7, 2013, Pages 274-279

Efficacy and safety of sirolimus-eluting stents versus bare-metal stents in coronary artery disease patients with diabetes: A meta-analysis

Author keywords

Bare metal stent; Diabetes; Efficacy; Meta analysis; Safety; Sirolimus eluting stent

Indexed keywords

RAPAMYCIN;

EID: 84889262252     PISSN: 19951892     EISSN: None     Source Type: Journal    
DOI: 10.5830/CVJA-2013-062     Document Type: Article
Times cited : (3)

References (36)
  • 2
    • 84879082891 scopus 로고    scopus 로고
    • Recent insights into the treatment of stable CAD: FFR-guided PCI vs. Medical therapy
    • 2013 Apr 17. [Epub ahead of print]
    • Van Nunen LX, Tonino PA. Recent insights into the treatment of stable CAD: FFR-guided PCI vs. medical therapy. Herz 2013. 2013 Apr 17. [Epub ahead of print].
    • (2013) Herz
    • Van Nunen, L.X.1    Tonino, P.A.2
  • 3
    • 0242489268 scopus 로고    scopus 로고
    • Long-Term Outcome after Implantation of Bare Metal Stents for the Treatment of Coronary Artery Disease: Rationale for the Clinical Use of Antiproliferative Stent Coatings
    • DOI 10.1046/j.1540-8183.2003.01059.x
    • Haase J, Jung T, Störger H, Hofmann M, Reinemer H, Schwarz CE, et al. Long-term outcome after implantation of bare metal stents for the treatment of coronary artery disease: rationale for the clinical use of antiproliferative stent coatings. J Interv Cardiol 2003; 16(6): 469-473. (Pubitemid 37431013)
    • (2003) Journal of Interventional Cardiology , vol.16 , Issue.6 , pp. 469-473
    • Haase, J.1    Jung, T.2    Storger, H.3    Hofmann, M.4    Reinemer, H.5    Schwarz, C.-E.6    Schopf, J.7    Schwarz, F.8
  • 4
    • 84877897256 scopus 로고    scopus 로고
    • The Supralimus® sirolimus-eluting stent
    • 2013 Apr 18. [Epub ahead of print]
    • Lemos PA, Bienert I. The Supralimus® sirolimus-eluting stent. Expert Rev Med Devices 2013. 2013 Apr 18. [Epub ahead of print].
    • (2013) Expert Rev Med Devices
    • Lemos, P.A.1    Bienert, I.2
  • 5
    • 84876363171 scopus 로고    scopus 로고
    • Acute and long-term outcomes of ostial stentings among bare-metal stents, sirolimus-eluting stents, and paclitaxel-eluting stents
    • Hsieh IC, Chang SH, Wang CY, Lee CH, Lin FC, Chen CC. Acute and long-term outcomes of ostial stentings among bare-metal stents, sirolimus-eluting stents, and paclitaxel-eluting stents. Coron Artery Dis 2013; 24(3): 224-230.
    • (2013) Coron Artery Dis , vol.24 , Issue.3 , pp. 224-230
    • Hsieh, I.C.1    Chang, S.H.2    Wang, C.Y.3    Lee, C.H.4    Lin, F.C.5    Chen, C.C.6
  • 6
    • 84887321684 scopus 로고    scopus 로고
    • In-stent restenosis is inhibited in a bare metal stent implanted distal to a sirolimus-eluting stent to treat a long de novo coronary lesion with small distal vessel diameter
    • 2013 Feb 4. doi: 10.1002/ccd.24841. [Epub ahead of print]
    • Obata JE, Nakamura T, Kitta Y, Saito Y, Sano K, Fujioka D, Kawabata KI, et al. In-stent restenosis is inhibited in a bare metal stent implanted distal to a sirolimus-eluting stent to treat a long de novo coronary lesion with small distal vessel diameter. Catheter Cardiovasc Interv 2013. 2013 Feb 4. doi: 10.1002/ccd.24841. [Epub ahead of print].
    • (2013) Catheter Cardiovasc Interv
    • Obata, J.E.1    Nakamura, T.2    Kitta, Y.3    Saito, Y.4    Sano, K.5    Fujioka, D.6    Kawabata, K.I.7
  • 7
    • 80051729522 scopus 로고    scopus 로고
    • Intravascular ultrasound results from the NEVO ResElution-I trial: A randomized, blinded comparison of sirolimuseluting NEVO stents with paclitaxel-eluting TAXUS Liberté stents in de novo native coronary artery lesions
    • Otake H, Honda Y, Courtney BK, Shimohama T, Ako J, Waseda K, Macours N, et al. Intravascular ultrasound results from the NEVO ResElution-I trial: a randomized, blinded comparison of sirolimuseluting NEVO stents with paclitaxel-eluting TAXUS Liberté stents in de novo native coronary artery lesions. Circ Cardiovasc Interv 2011; 4(2): 146-154.
    • (2011) Circ Cardiovasc Interv , vol.4 , Issue.2 , pp. 146-154
    • Otake, H.1    Honda, Y.2    Courtney, B.K.3    Shimohama, T.4    Ako, J.5    Waseda, K.6    Macours, N.7
  • 9
    • 84876734114 scopus 로고    scopus 로고
    • Meta-analysis comparing efficacy and safety of first generation drug-eluting stents to baremetal stents in patients with diabetes mellitus undergoing primary percutaneous coronary intervention
    • DESERT Cooperation
    • De Luca G, Dirksen MT, Spaulding C, Kelbæk H, Schalij M, Thuesen L, van der Hoeven B, et al.; DESERT Cooperation. Meta-analysis comparing efficacy and safety of first generation drug-eluting stents to baremetal stents in patients with diabetes mellitus undergoing primary percutaneous coronary intervention. Am J Cardiol 2013; 111(9): 1295-1304.
    • (2013) Am J Cardiol , vol.111 , Issue.9 , pp. 1295-1304
    • De Luca, G.1    Dirksen, M.T.2    Spaulding, C.3    Kelbæk, H.4    Schalij, M.5    Thuesen, L.6    Van Der Hoeven, B.7
  • 10
    • 84866604206 scopus 로고    scopus 로고
    • Outcomes with various drug eluting or bare metal stents in patients with diabetes mellitus: Mixed treatment comparison analysis of 22,844 patient years of follow-up from randomised trials
    • Bangalore S, Kumar S, Fusaro M, Amoroso N, Kirtane AJ, Byrne RA, Williams DO, et al. Outcomes with various drug eluting or bare metal stents in patients with diabetes mellitus: mixed treatment comparison analysis of 22,844 patient years of follow-up from randomised trials. Br Med J 2012; 345: e5170.
    • (2012) Br Med J , vol.345
    • Bangalore, S.1    Kumar, S.2    Fusaro, M.3    Amoroso, N.4    Kirtane, A.J.5    Byrne, R.A.6    Williams, D.O.7
  • 11
    • 84858325107 scopus 로고    scopus 로고
    • SCORPIUS Study. Five-year results of the Multicenter Randomized Controlled Open-Label Study of the CYPHER Sirolimus-Eluting Stent in the Treatment of Diabetic Patients with de Novo Native Coronary Artery Lesions (SCORPIUS) study: A German multicenter investigation on the effectiveness of sirolimus-eluting stents in diabetic patients
    • Sinning JM, Baumgart D, Werner N, Klauss V, Baer FM, Hartmann F, Drexler H, et al.; SCORPIUS Study. Five-year results of the Multicenter Randomized Controlled Open-Label Study of the CYPHER Sirolimus-Eluting Stent in the Treatment of Diabetic Patients with De Novo Native Coronary Artery Lesions (SCORPIUS) study: a German multicenter investigation on the effectiveness of sirolimus-eluting stents in diabetic patients. Am Heart J 2012; 163(3): 446-453.
    • (2012) Am Heart J , vol.163 , Issue.3 , pp. 446-453
    • Sinning, J.M.1    Baumgart, D.2    Werner, N.3    Klauss, V.4    Baer, F.M.5    Hartmann, F.6    Drexler, H.7
  • 12
    • 26944434867 scopus 로고    scopus 로고
    • The efficacy of sirolimus-eluting stents versus bare metal stents for diabetic patients undergoing elective percutaneous coronary intervention
    • Aoki J, Ong A, Rodriguez-Granillo G, Van Mieghem C, Daemen J, Sonnenschein K, McFadden E, et al. The efficacy of sirolimus-eluting stents versus bare metal stents for diabetic patients undergoing elective percutaneous coronary intervention. J Invasive Cardiol 2005; 17(7): 344-348.
    • (2005) J Invasive Cardiol , vol.17 , Issue.7 , pp. 344-348
    • Aoki, J.1    Ong, A.2    Rodriguez-Granillo, G.3    Van Mieghem, C.4    Daemen, J.5    Sonnenschein, K.6    McFadden, E.7
  • 13
    • 43549111358 scopus 로고    scopus 로고
    • Comparison of effectiveness and safety of sirolimus-eluting stents versus bare-metal stents in patients with diabetes mellitus (from the Italian Multicenter Randomized DESSERT Study)
    • DESSERT Investigators
    • Maresta A, Varani E, Balducelli M, Varbella F, Lettieri C, Uguccioni L, Sangiorgio P, et al.; DESSERT Investigators. Comparison of effectiveness and safety of sirolimus-eluting stents versus bare-metal stents in patients with diabetes mellitus (from the Italian Multicenter Randomized DESSERT Study). Am J Cardiol 2008; 101(11): 1560-1566.
    • (2008) Am J Cardiol , vol.101 , Issue.11 , pp. 1560-1566
    • Maresta, A.1    Varani, E.2    Balducelli, M.3    Varbella, F.4    Lettieri, C.5    Uguccioni, L.6    Sangiorgio, P.7
  • 14
    • 58749108849 scopus 로고    scopus 로고
    • A randomized comparison of sirolimus-eluting versus bare metal stents in the treatment of diabetic patients with native coronary artery lesions: The DECODE study
    • DECODE investigators
    • Chan C, Zambahari R, Kaul U, Lau CP, Whitworth H, Cohen S, Buchbinder M; DECODE investigators. A randomized comparison of sirolimus-eluting versus bare metal stents in the treatment of diabetic patients with native coronary artery lesions: the DECODE study. Catheter Cardiovasc Interv 2008; 72(5): 591-600.
    • (2008) Catheter Cardiovasc Interv , vol.72 , Issue.5 , pp. 591-600
    • Chan, C.1    Zambahari, R.2    Kaul, U.3    Lau, C.P.4    Whitworth, H.5    Cohen, S.6    Buchbinder, M.7
  • 17
    • 0022992740 scopus 로고
    • Meta-analysis in clinical trials
    • DOI 10.1016/0197-2456(86)90046-2
    • DerSimonian R. Meta-analysis in clinical trials. Control Clin Trials 1986; 7(3): 177-188. (Pubitemid 17189972)
    • (1986) Controlled Clinical Trials , vol.7 , Issue.3 , pp. 177-188
    • DerSimonian, R.1    Laird, N.2
  • 18
    • 0029898186 scopus 로고    scopus 로고
    • Meta-analysis in the design and monitoring of clinical trials
    • DerSimonian R. Meta-analysis in the design and monitoring of clinical trials. Stat Med 1996 15(12): 1237-1248.
    • (1996) Stat Med , vol.15 , Issue.12 , pp. 1237-1248
    • DerSimonian, R.1
  • 19
    • 0031045957 scopus 로고    scopus 로고
    • Large trials vs meta-analysis of smaller trials
    • Klebanoff MA, Levine RJ, DerSimonian R. Large trials vs meta-analysis of smaller trials. J Am Med Assoc 1997; 277(5): 376-377.
    • (1997) J Am Med Assoc , vol.277 , Issue.5 , pp. 376-377
    • Klebanoff, M.A.1    Levine, R.J.2    DerSimonian, R.3
  • 20
    • 0033616911 scopus 로고    scopus 로고
    • Conference on meta-analysis in the design and monitoring of clinical trials
    • Geller N, Freedman L, Lee YJ, DerSimonian R. Conference on meta-analysis in the design and monitoring of clinical trials. Stat Med 1999; 18(6): 753-754.
    • (1999) Stat Med , vol.18 , Issue.6 , pp. 753-754
    • Geller, N.1    Freedman, L.2    Lee, Y.J.3    DerSimonian, R.4
  • 21
    • 68049122102 scopus 로고    scopus 로고
    • PRISMA group. Preferred reporting items for systematic reviews and meta-analyses: The PRISMA statement
    • Moher D, Liberati A, Tetzlaff J, Altman DG; PRISMA group. Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. PLoS Med 2009; 6(7): e1000097.
    • (2009) PLoS Med , vol.6 , Issue.7
    • Moher, D.1    Liberati, A.2    Tetzlaff, J.3    Altman, D.G.4
  • 22
    • 79961238388 scopus 로고    scopus 로고
    • Recommendations for examining and interpreting funnel plot asymmetry in meta-analyses of randomised controlled trials
    • Sterne JA, Sutton AJ, Ioannidis JP, Terrin N, Jones DR, Lau J, Carpenter J, et al. Recommendations for examining and interpreting funnel plot asymmetry in meta-analyses of randomised controlled trials. Br Med J 2011; 343: D4002.
    • (2011) Br Med J , vol.343
    • Sterne, J.A.1    Sutton, A.J.2    Ioannidis, J.P.3    Terrin, N.4    Jones, D.R.5    Lau, J.6    Carpenter, J.7
  • 23
    • 0033581227 scopus 로고    scopus 로고
    • Resolving discrepancies between a meta-analysis and a subsequent large controlled trial
    • DOI 10.1001/jama.282.7.664
    • DerSimonian R, Levine RJ. Resolving discrepancies between a meta-analysis and a subsequent large controlled trial. J Am Med Assoc 1999; 282(7): 664-670. (Pubitemid 29384155)
    • (1999) Journal of the American Medical Association , vol.282 , Issue.7 , pp. 664-670
    • DerSimonian, R.1    Levine, R.J.2
  • 24
    • 33845571913 scopus 로고    scopus 로고
    • Random-effects model for meta-analysis of clinical trials: An update
    • DOI 10.1016/j.cct.2006.04.004, PII S1551714406000486
    • DerSimonian R, Kacker R. Random-effects model for meta-analysis of clinical trials: an update. Contemp Clin Trials 2007; 28(2): 105-114. (Pubitemid 44937874)
    • (2007) Contemporary Clinical Trials , vol.28 , Issue.2 , pp. 105-114
    • DerSimonian, R.1    Kacker, R.2
  • 25
    • 79955544813 scopus 로고    scopus 로고
    • Interpretation of random effects meta-analyses
    • Riley RD, Higgins JP, Deeks JJ. Interpretation of random effects meta-analyses. Br Med J 2011; 342(d549).
    • (2011) Br Med J , vol.342 , Issue.D549
    • Riley, R.D.1    Higgins, J.P.2    Deeks, J.J.3
  • 26
    • 84863414972 scopus 로고    scopus 로고
    • A generalized weighting regression-derived meta-analysis estimator robust to small-study effects and heterogeneity
    • Moreno SG, Sutton AJ, Thompson JR, Ades AE, Abrams KR, Cooper NJ. A generalized weighting regression-derived meta-analysis estimator robust to small-study effects and heterogeneity. Stat Med 2012; 31(14): 1407-1417.
    • (2012) Stat Med , vol.31 , Issue.14 , pp. 1407-1417
    • Moreno, S.G.1    Sutton, A.J.2    Thompson, J.R.3    Ades, A.E.4    Abrams, K.R.5    Cooper, N.J.6
  • 27
    • 0037098199 scopus 로고    scopus 로고
    • Quantifying heterogeneity in a meta-analysis
    • DOI 10.1002/sim.1186
    • Higgins JP, Thompson SG. Quantifying heterogeneity in a meta-analysis. Stat Med 2002; 21(11): 1539-1558. (Pubitemid 34746062)
    • (2002) Statistics in Medicine , vol.21 , Issue.11 , pp. 1539-1558
    • Higgins, J.P.T.1    Thompson, S.G.2
  • 28
    • 0030922816 scopus 로고    scopus 로고
    • Bias in meta-analysis detected by a simple, graphical test
    • Egger M, Davey Smith G, Schneider M, Minder C. Bias in meta-analysis detected by a simple, graphical test. Br Med J 1997; 315(7109): 629-634. (Pubitemid 27387172)
    • (1997) British Medical Journal , vol.315 , Issue.7109 , pp. 629-634
    • Egger, M.1    Smith, G.D.2    Schneider, M.3    Minder, C.4
  • 29
    • 84880886221 scopus 로고    scopus 로고
    • Sirolimus-eluting stent versus bare metal stent in diabetic patients: The final five-year follow-up of the DIABETES trial
    • 2013 Mar 22. pii: 20120620-01. [Epub ahead of print]
    • Jiménez-Quevedo P, Hernando L, Gómez-Hospital JA, Iñiguez A, Sanroman A, Alfonso F, Hernández-Antolín R, et al. Sirolimus-eluting stent versus bare metal stent in diabetic patients: the final five-year follow-up of the DIABETES trial. EuroIntervention 2013; 2013 Mar 22. pii: 20120620-01. [Epub ahead of print].
    • (2013) EuroIntervention
    • Jiménez-Quevedo, P.1    Hernando, L.2    Gómez-Hospital, J.A.3    Iñiguez, A.4    Sanroman, A.5    Alfonso, F.6    Hernández-Antolín, R.7
  • 30
    • 80054967588 scopus 로고    scopus 로고
    • Long-term clinical and angiographic results of Sirolimus-Eluting Stent in Complex Coronary Chronic Total Occlusion Revascularization: The SECTOR registry
    • Galassi AR, Tomasello SD, Costanzo L, Campisano MB, Barrano G, Tamburino C. Long-term clinical and angiographic results of Sirolimus-Eluting Stent in Complex Coronary Chronic Total Occlusion Revascularization: the SECTOR registry. J Interv Cardiol 2011; 24(5): 426-436.
    • (2011) J Interv Cardiol , vol.24 , Issue.5 , pp. 426-436
    • Galassi, A.R.1    Tomasello, S.D.2    Costanzo, L.3    Campisano, M.B.4    Barrano, G.5    Tamburino, C.6
  • 31
    • 80051800172 scopus 로고    scopus 로고
    • Long-term outcome after sirolimus-eluting stents versus bare metal stents in patients with diabetes mellitus: A patient-level meta-analysis of randomized trials
    • De Waha A, Dibra A, Kufner S, Baumgart D, Sabate M, Maresta A, Schömig A, Kastrati A. Long-term outcome after sirolimus-eluting stents versus bare metal stents in patients with diabetes mellitus: a patient-level meta-analysis of randomized trials. Clin Res Cardiol 2011; 100(7): 561-570.
    • (2011) Clin Res Cardiol , vol.100 , Issue.7 , pp. 561-570
    • De Waha, A.1    Dibra, A.2    Kufner, S.3    Baumgart, D.4    Sabate, M.5    Maresta, A.6    Schömig, A.7    Kastrati, A.8
  • 32
    • 59149105598 scopus 로고    scopus 로고
    • Clinical and angiographic outcomes with sirolimus-eluting stents in total coronary occlusions: The ACROSS/TOSCA-4 (Approaches to Chronic Occlusions With Sirolimus-Eluting Stents/Total Occlusion Study of Coronary Arteries-4) trial
    • ACROSS/TOSCA-4 investigators
    • Kandzari DE, Rao SV, Moses JW, Dzavik V, Strauss BH, Kutryk MJ, Simonton CA, et al; ACROSS/TOSCA-4 investigators. Clinical and angiographic outcomes with sirolimus-eluting stents in total coronary occlusions: the ACROSS/TOSCA-4 (Approaches to Chronic Occlusions With Sirolimus-Eluting Stents/Total Occlusion Study of Coronary Arteries-4) trial. J Am Coll Cardiol Cardiovasc Interv 2009; 2(2): 97-106.
    • (2009) J Am Coll Cardiol Cardiovasc Interv , vol.2 , Issue.2 , pp. 97-106
    • Kandzari, D.E.1    Rao, S.V.2    Moses, J.W.3    Dzavik, V.4    Strauss, B.H.5    Kutryk, M.J.6    Simonton, C.A.7
  • 33
    • 55749106625 scopus 로고    scopus 로고
    • Is there a preferable DES in diabetic patients? A critical appraisal of the evidence
    • Byrne RA, Kastrati A. Is there a preferable DES in diabetic patients? A critical appraisal of the evidence. Catheter Cardiovasc Interv 2008; 72(7): 944-949.
    • (2008) Catheter Cardiovasc Interv , vol.72 , Issue.7 , pp. 944-949
    • Byrne, R.A.1    Kastrati, A.2
  • 34
    • 0037098178 scopus 로고    scopus 로고
    • How should meta-regression analyses be undertaken and interpreted?
    • DOI 10.1002/sim.1187
    • Thompson SG, Higgins JP. How should meta-regression analyses be undertaken and interpreted? Stat Med 2002; 21(11): 1559-1573. (Pubitemid 34746063)
    • (2002) Statistics in Medicine , vol.21 , Issue.11 , pp. 1559-1573
    • Thompson, S.G.1    Higgins, J.P.T.2
  • 35
    • 0034823867 scopus 로고    scopus 로고
    • Funnel plots for detecting bias in meta-analysis: Guidelines on choice of axis
    • DOI 10.1016/S0895-4356(01)00377-8, PII S0895435601003778
    • Sterne JA, Egger M. Funnel plots for detecting bias in meta-analysis: guidelines on choice of axis. J Clin Epidemiol 2001; 54(10): 1046-1055. (Pubitemid 32888370)
    • (2001) Journal of Clinical Epidemiology , vol.54 , Issue.10 , pp. 1046-1055
    • Sterne, J.A.C.1    Egger, M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.