메뉴 건너뛰기




Volumn 82, Issue 6, 2013, Pages

In-stent restenosis is inhibited in a bare metal stent implanted distal to a sirolimus-eluting stent to treat a long de novo coronary lesion with small distal vessel diameter

Author keywords

coronary artery disease (CAD); percutaneous coronary intervention (PCI); quantitative coronary angiography (QCA); restenosis (RSTN)

Indexed keywords

RAPAMYCIN; CARDIOVASCULAR AGENT; METAL;

EID: 84887321684     PISSN: 15221946     EISSN: 1522726X     Source Type: Journal    
DOI: 10.1002/ccd.24841     Document Type: Article
Times cited : (9)

References (27)
  • 1
    • 0037030658 scopus 로고    scopus 로고
    • RAVEL Study Group. Randomized study with the sirolimus-coated Bx Velocity balloon-expandable stent in the treatment of patients with de novo native coronary artery lesions. A randomized comparison of a sirolimus-eluting stent with a standard stent for coronary revascularization
    • Morice MC, Serruys PW, Sousa JE, Fajadet J, Ban Hayashi E, Perin M, Colombo A, Schuler G, Barragan P, Guagliumi G, Molnar F, Falotico R,; RAVEL Study Group. Randomized study with the sirolimus-coated Bx Velocity balloon-expandable stent in the treatment of patients with de novo native coronary artery lesions. A randomized comparison of a sirolimus-eluting stent with a standard stent for coronary revascularization. N Engl J Med 2002; 346: 1773-1780.
    • (2002) N Engl J Med , vol.346 , pp. 1773-1780
    • Morice, M.C.1    Serruys, P.W.2    Sousa, J.E.3    Fajadet, J.4    Ban Hayashi, E.5    Perin, M.6    Colombo, A.7    Schuler, G.8    Barragan, P.9    Guagliumi, G.10    Molnar, F.11    Falotico, R.12
  • 5
    • 33751159826 scopus 로고    scopus 로고
    • Safety and efficacy of the 2.25-mm sirolimus-eluting Bx Velocity stent in the treatment of patients with de novo native coronary artery lesions: The SIRIUS 2.25 trial
    • for the SIRIUS 2.25 Investigators.
    • Moses JW, Nikolsky E, Mehran R, Cambier PA, Bachinsky WB, Leya F, Kuntz RE, Popma JJ, Schleckser P, Wang H, Cohen SA, Leon MB, for the SIRIUS 2.25 Investigators. Safety and efficacy of the 2.25-mm sirolimus-eluting Bx Velocity stent in the treatment of patients with de novo native coronary artery lesions: the SIRIUS 2.25 trial. Am J Cardiol 2006; 98: 1455-1460.
    • (2006) Am J Cardiol , vol.98 , pp. 1455-1460
    • Moses, J.W.1    Nikolsky, E.2    Mehran, R.3    Cambier, P.A.4    Bachinsky, W.B.5    Leya, F.6    Kuntz, R.E.7    Popma, J.J.8    Schleckser, P.9    Wang, H.10    Cohen, S.A.11    Leon, M.B.12
  • 7
    • 66349135434 scopus 로고    scopus 로고
    • Safety and efficacy of 2.5-mm sirolimus-eluting stent implantation at lower deployment pressures in very small vessels (<2.5 mm)
    • Umeda H, Iwase M, Gochi T, Izawa H, Ishiki R, Inagaki H, Shimizu T, Yokota M, Murohara T,. Safety and efficacy of 2.5-mm sirolimus-eluting stent implantation at lower deployment pressures in very small vessels (<2.5 mm). Coron Artery Dis 2009; 20: 163-168.
    • (2009) Coron Artery Dis , vol.20 , pp. 163-168
    • Umeda, H.1    Iwase, M.2    Gochi, T.3    Izawa, H.4    Ishiki, R.5    Inagaki, H.6    Shimizu, T.7    Yokota, M.8    Murohara, T.9
  • 10
    • 30344477607 scopus 로고    scopus 로고
    • Sirolimus PK trail: A pharmacokinetic study of the sirolimus-eluting Bx Velocity stent in patients with de novo coronary lesions
    • Vetrovec GW, Rizik D, Williard C, Snead D, Piotrovski V, Kopia G,. Sirolimus PK trail: A pharmacokinetic study of the sirolimus-eluting Bx Velocity stent in patients with de novo coronary lesions. Cathet Cardiovasc Intervent 2006; 67: 32-37.
    • (2006) Cathet Cardiovasc Intervent , vol.67 , pp. 32-37
    • Vetrovec, G.W.1    Rizik, D.2    Williard, C.3    Snead, D.4    Piotrovski, V.5    Kopia, G.6
  • 16
    • 0033485806 scopus 로고    scopus 로고
    • Hemodynamic shear stress and its role in atherosclerosis
    • Malek AM, Alper SL, Izumo S,. Hemodynamic shear stress and its role in atherosclerosis. JAMA 1999; 282: 2035-2042.
    • (1999) JAMA , vol.282 , pp. 2035-2042
    • Malek, A.M.1    Alper, S.L.2    Izumo, S.3
  • 17
    • 20444432377 scopus 로고    scopus 로고
    • Strut position, blood flow, and drug deposition: Implications for single and overlapping drug-eluting stents
    • Balakrishnan B, Tzafriri AR, Seifert P, Groothuis A, Rogers C, Edelman ER,. Strut position, blood flow, and drug deposition: Implications for single and overlapping drug-eluting stents. Circulation 2005; 111: 2958-2965.
    • (2005) Circulation , vol.111 , pp. 2958-2965
    • Balakrishnan, B.1    Tzafriri, A.R.2    Seifert, P.3    Groothuis, A.4    Rogers, C.5    Edelman, E.R.6
  • 24
    • 76749157456 scopus 로고    scopus 로고
    • Outcomes of overlapping bare-metal stents with sirolimus-eluting stents for long lesions in small coronary vessels
    • Kronsteiner E, Lee RW, Sweeney JP, Metallo JR, Stoehr JD, Fortuin FD,. Outcomes of overlapping bare-metal stents with sirolimus-eluting stents for long lesions in small coronary vessels. J Invasive Cardiol 2010; 22: 76-79.
    • (2010) J Invasive Cardiol , vol.22 , pp. 76-79
    • Kronsteiner, E.1    Lee, R.W.2    Sweeney, J.P.3    Metallo, J.R.4    Stoehr, J.D.5    Fortuin, F.D.6
  • 27
    • 34047128078 scopus 로고    scopus 로고
    • Overlapping hybrid stenting with a sirolimur-eluting stent and a bare metal stent
    • Takano M, Murakami D, Mizuno K,. Overlapping hybrid stenting with a sirolimur-eluting stent and a bare metal stent. Int J Cardiol 2007; 118: e8-e10.
    • (2007) Int J Cardiol , vol.118
    • Takano, M.1    Murakami, D.2    Mizuno, K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.