메뉴 건너뛰기




Volumn 11, Issue 3, 2013, Pages 159-166

Biomechanical behavior of bone scaffolds made of additive manufactured tricalciumphosphate and titanium alloy under different loading conditions

Author keywords

Bone scaffolds; Large segmental bone defects; Mechanical properties; Sintered tricalciumphosphate; Static loading; Titanium

Indexed keywords

3D PRINTERS; BIOMECHANICS; BONE; COMPRESSIVE STRENGTH; DEFECTS; MECHANICAL STABILITY; PORE SIZE; SCAFFOLDS; SCAFFOLDS (BIOLOGY); TENSILE STRENGTH; TITANIUM ALLOYS; TRANSMISSION CONTROL PROTOCOL;

EID: 84888812718     PISSN: None     EISSN: 22808000     Source Type: Journal    
DOI: 10.5301/JABFM.2013.10832     Document Type: Article
Times cited : (27)

References (31)
  • 1
    • 1542318294 scopus 로고    scopus 로고
    • Mechanical failure of porous hydroxyapatite ceramics 7.5 years after implantation in the proximal tibial
    • Linhart W, Briem D, Amling M, Rueger JM, Windolf J. [Mechanical failure of porous hydroxyapatite ceramics 7.5 years after implantation in the proximal tibial]. Unfallchirurg 2004; 107: 154-7.
    • (2004) Unfallchirurg , vol.107 , pp. 154-157
    • Linhart, W.1    Briem, D.2    Amling, M.3    Rueger, J.M.4    Windolf, J.5
  • 2
    • 0024377022 scopus 로고
    • Morbidity at bone graft donor sites
    • Younger EM, Chapman MW. Morbidity at bone graft donor sites. J Orthop Trauma 1989; 3: 192-5.
    • (1989) J Orthop Trauma , vol.3 , pp. 192-195
    • Younger, E.M.1    Chapman, M.W.2
  • 3
    • 0036934181 scopus 로고    scopus 로고
    • Long-term outcomes after using porous hydroxyapatite ceramics (Endobon) for surgical management of fractures of the head of the tibia
    • Briem D, Linhart W, Lehmann W, Meenen NM, Rueger JM. [Long-term outcomes after using porous hydroxyapatite ceramics (Endobon) for surgical management of fractures of the head of the tibia]. Unfallchirurg 2002; 105: 128-33.
    • (2002) Unfallchirurg , vol.105 , pp. 128-133
    • Briem, D.1    Linhart, W.2    Lehmann, W.3    Meenen, N.M.4    Rueger, J.M.5
  • 4
    • 0024592275 scopus 로고
    • Macroporous calcium phosphate bioceramics in dog femora: A histological study of interface and biodegradation
    • Klein CP, Patka P, den HW. Macroporous calcium phosphate bioceramics in dog femora: a histological study of interface and biodegradation. Biomaterials 1989; 10: 59-62.
    • (1989) Biomaterials , vol.10 , pp. 59-62
    • Klein, C.P.1    Patka, P.2    Den, H.W.3
  • 5
    • 71649110868 scopus 로고    scopus 로고
    • A comparative assessment of synthetic ceramic bone substitutes with different composition and microstructure in rabbit femoral condyle model
    • Yamasaki N, Hirao M, Nanno K et al. A comparative assessment of synthetic ceramic bone substitutes with different composition and microstructure in rabbit femoral condyle model. J Biomed Mater Res B Appl Biomater 2009; 91: 788-98.
    • (2009) J Biomed Mater Res B Appl Biomater , vol.91 , pp. 788-798
    • Yamasaki, N.1    Hirao, M.2    Nanno, K.3
  • 6
    • 0030152540 scopus 로고    scopus 로고
    • Porous ceramics as bone graft substitutes in long bone defects: A biomechanical, histological, and radiographic analysis
    • Johnson KD, Frierson KE, Keller TS et al. Porous ceramics as bone graft substitutes in long bone defects: a biomechanical, histological, and radiographic analysis. J Orthop Res 1996; 14: 351-69.
    • (1996) J Orthop Res , vol.14 , pp. 351-369
    • Johnson, K.D.1    Frierson, K.E.2    Keller, T.S.3
  • 7
    • 0031278010 scopus 로고    scopus 로고
    • Evaluation of bovinederived bone protein with a natural coral carrier as a bonegraft substitute in a canine segmental defect model
    • Sciadini MF, Dawson JM, Johnson KD. Evaluation of bovinederived bone protein with a natural coral carrier as a bonegraft substitute in a canine segmental defect model. J Orthop Res 1997; 15: 844-57.
    • (1997) J Orthop Res , vol.15 , pp. 844-857
    • Sciadini, M.F.1    Dawson, J.M.2    Johnson, K.D.3
  • 9
    • 73549097762 scopus 로고    scopus 로고
    • In vivo performance of selective electron beam-melted Ti-6Al-4V structures
    • Ponader S, von Wilmowsky C, Widenmayer M, et al. In vivo performance of selective electron beam-melted Ti-6Al-4V structures. J Biomed Mater Res A 2010; 92: 56-62.
    • (2010) J Biomed Mater Res A , vol.92 , pp. 56-62
    • Ponader, S.1    von Wilmowsky, C.2    Widenmayer, M.3
  • 10
    • 84866173471 scopus 로고    scopus 로고
    • Migration capacity and viability of human primary osteoblasts in synthetic threedimensional bone scaffolds made of tricalciumphosphate
    • Jonitz A, Wieding J, Lochner K et al. Migration capacity and viability of human primary osteoblasts in synthetic threedimensional bone scaffolds made of tricalciumphosphate. Materials (Basel) 2011; 4: 1249-59.
    • (2011) Materials (Basel) , vol.4 , pp. 1249-1259
    • Jonitz, A.1    Wieding, J.2    Lochner, K.3
  • 11
    • 55349138081 scopus 로고    scopus 로고
    • Selective electron beam melting of cellular titanium: Mechanical properties
    • Heinl P, Koerner C, Singer RF. Selective electron beam melting of cellular titanium: mechanical properties. Adv Eng Mater 2008; 10: 882-8.
    • (2008) Adv Eng Mater , vol.10 , pp. 882-888
    • Heinl, P.1    Koerner, C.2    Singer, R.F.3
  • 14
    • 75149134663 scopus 로고    scopus 로고
    • Mechanical evaluation of porous titanium (Ti6Al4V) structures with electron beam melting (EBM)
    • Parthasarathy J, Starly B, Raman S, Christensen A. Mechanical evaluation of porous titanium (Ti6Al4V) structures with electron beam melting (EBM). J Mech Behav Biomed Mater 2010; 3: 249-59.
    • (2010) J Mech Behav Biomed Mater , vol.3 , pp. 249-259
    • Parthasarathy, J.1    Starly, B.2    Raman, S.3    Christensen, A.4
  • 16
    • 38349070442 scopus 로고    scopus 로고
    • Titanium scaffolds for osteointegration: Mechanical, in vitro and corrosion behaviour
    • Cachinho SC, Correia RN. Titanium scaffolds for osteointegration: mechanical, in vitro and corrosion behaviour. J Mater Sci Mater Med 2008; 19: 451-7.
    • (2008) J Mater Sci Mater Med , vol.19 , pp. 451-457
    • Cachinho, S.C.1    Correia, R.N.2
  • 17
    • 0019993718 scopus 로고
    • Preparation and some properties of sintered beta-whitlockite
    • Driessen AA, Klein CP, de GK. Preparation and some properties of sintered beta-whitlockite. Biomaterials 1982; 3: 113-6.
    • (1982) Biomaterials , vol.3 , pp. 113-116
    • Driessen, A.A.1    Klein, C.P.2    de, G.K.3
  • 18
    • 0032896979 scopus 로고    scopus 로고
    • Mechanical properties of sintered hydroxyapatite and tricalcium phosphate ceramic
    • Metsger DS, Rieger MR, Foreman DW. Mechanical properties of sintered hydroxyapatite and tricalcium phosphate ceramic. J Mater Sci Mater Med 1999; 10: 9-17.
    • (1999) J Mater Sci Mater Med , vol.10 , pp. 9-17
    • Metsger, D.S.1    Rieger, M.R.2    Foreman, D.W.3
  • 19
    • 84866145490 scopus 로고    scopus 로고
    • Evaluation of titanium alloys fabricated using rapid prototyping technologies electron beam melting and laser beam melting
    • Koike M, Greer P, Owen K et al. Evaluation of titanium alloys fabricated using rapid prototyping technologies electron beam melting and laser beam melting. Materials (Basel) 2011; 4: 1776-92.
    • (2011) Materials (Basel) , vol.4 , pp. 1776-1792
    • Koike, M.1    Greer, P.2    Owen, K.3
  • 20
    • 67149115153 scopus 로고    scopus 로고
    • Different calcium phosphate granules for 3-D printing of bone tissue engineering scaffolds
    • Seitz H, Deisinger U, Leukers B, Detsch R, Ziegler G. Different calcium phosphate granules for 3-D printing of bone tissue engineering scaffolds. Adv Eng Mater 2009; 11: B41-6.
    • (2009) Adv Eng Mater , vol.11
    • Seitz, H.1    Deisinger, U.2    Leukers, B.3    Detsch, R.4    Ziegler, G.5
  • 21
    • 80051550066 scopus 로고    scopus 로고
    • In vitro-osteoclastic activity studies on surfaces of 3D printed calcium phosphate scaffolds
    • Detsch R, Schaefer S, Deisinger U, Ziegler G, Seitz H, Leukers B. In vitro-osteoclastic activity studies on surfaces of 3D printed calcium phosphate scaffolds. J Biomater Appl. 2011;26(3):359-80.
    • (2011) J Biomater Appl , vol.26 , Issue.3 , pp. 359-380
    • Detsch, R.1    Schaefer, S.2    Deisinger, U.3    Ziegler, G.4    Seitz, H.5    Leukers, B.6
  • 22
    • 84859081974 scopus 로고    scopus 로고
    • Finite element analysis of osteosynthesis screw fixation in the bone stock: An appropriate method for automatic screw modelling
    • Wieding J, Souffrant R, Fritsche A, Mittelmeier W, Bader R. Finite element analysis of osteosynthesis screw fixation in the bone stock: an appropriate method for automatic screw modelling. PLoS One 2012; 7: e33776.
    • (2012) PLoS One , vol.7
    • Wieding, J.1    Souffrant, R.2    Fritsche, A.3    Mittelmeier, W.4    Bader, R.5
  • 23
    • 0034984126 scopus 로고    scopus 로고
    • Hip contact forces and gait patterns from routine activities
    • Bergmann G, Deuretzbacher G, Heller M et al. Hip contact forces and gait patterns from routine activities. J Biomech 2001; 34: 859-71.
    • (2001) J Biomech , vol.34 , pp. 859-871
    • Bergmann, G.1    Deuretzbacher, G.2    Heller, M.3
  • 24
    • 63449137121 scopus 로고    scopus 로고
    • Qualification of Electron Beam Melted (EBM) Ti6AI4V-ELI for orthopaedic applications. Medical Device Materials IV
    • 2008. Palm Desert, CA. Medical Device Materials IV: Materials and Processes for Medical Devices Conference 2007. 23-9-2007
    • Christensen A, Kircher R, Lippincott A. Qualification of Electron Beam Melted (EBM) Ti6AI4V-ELI for orthopaedic applications. Medical Device Materials IV: Proceedings of the Materials and Processes for Medical Devices Conference 2007, 48-53. 2008. Palm Desert, CA. Medical Device Materials IV: Materials and Processes for Medical Devices Conference 2007. 23-9-2007.
    • (2007) Proceedings of the Materials and Processes For Medical Devices Conference , pp. 48-53
    • Christensen, A.1    Kircher, R.2    Lippincott, A.3
  • 25
    • 77952479321 scopus 로고    scopus 로고
    • Microstructure and mechanical properties of Ti-6Al-4V produced by electron beam melting of pre-alloyed powders
    • Facchini L, Magalini E, Robotti P, Molinari A. Microstructure and mechanical properties of Ti-6Al-4V produced by electron beam melting of pre-alloyed powders. Rapid Prototyping Journal 2009; 15: 171-8.
    • (2009) Rapid Prototyping Journal , vol.15 , pp. 171-178
    • Facchini, L.1    Magalini, E.2    Robotti, P.3    Molinari, A.4
  • 26
    • 55249116312 scopus 로고    scopus 로고
    • Microstructure and mechanical behavior of Ti-6Al-4V produced by rapid-layer manufacturing, for biomedical applications
    • Murr LE, Quinones SA, Gaytan SM et al. Microstructure and mechanical behavior of Ti-6Al-4V produced by rapid-layer manufacturing, for biomedical applications. J Mech Behav Biomed Mater 2009; 2: 20-32.
    • (2009) J Mech Behav Biomed Mater , vol.2 , pp. 20-32
    • Murr, L.E.1    Quinones, S.A.2    Gaytan, S.M.3
  • 28
    • 56249137569 scopus 로고    scopus 로고
    • The design and production of Ti-6Al-4V ELI customized dental implants
    • Chahine G, Koike M, Okabe T, Smith P, Kovacevic R. The design and production of Ti-6Al-4V ELI customized dental implants. JOM (1989) 2008; 60: 50-5.
    • (2008) JOM (1989) , vol.60 , pp. 50-55
    • Chahine, G.1    Koike, M.2    Okabe, T.3    Smith, P.4    Kovacevic, R.5
  • 29
    • 77951848161 scopus 로고    scopus 로고
    • Next-generation biomedical implants using additive manufacturing of complex, cellular and functional mesh arrays
    • Murr LE, Gaytan SM, Medina F et al. Next-generation biomedical implants using additive manufacturing of complex, cellular and functional mesh arrays. Philos Transact A Math Phys Eng Sci 2010; 368: 1999-2032.
    • (2010) Philos Transact a Math Phys Eng Sci , vol.368 , pp. 1999-2032
    • Murr, L.E.1    Gaytan, S.M.2    Medina, F.3
  • 30
    • 67651176065 scopus 로고    scopus 로고
    • Distal femoral fixation: A biomechanical comparison of trigen retrograde intramedullary (i.m.) nail, dynamic condylar screw (DCS), and locking compression plate (LCP) condylar plate
    • Heiney JP, Barnett MD, Vrabec GA, Schoenfeld AJ, Baji A, Njus GO. Distal femoral fixation: a biomechanical comparison of trigen retrograde intramedullary (i.m.) nail, dynamic condylar screw (DCS), and locking compression plate (LCP) condylar plate. J Trauma 2009; 66: 443-9.
    • (2009) J Trauma , vol.66 , pp. 443-449
    • Heiney, J.P.1    Barnett, M.D.2    Vrabec, G.A.3    Schoenfeld, A.J.4    Baji, A.5    Njus, G.O.6
  • 31
    • 70349728914 scopus 로고    scopus 로고
    • Biomechanical comparison of polyaxial-type locking plates and a fixed-angle locking plate for internal fixation of distal femur fractures
    • Otto RJ, Moed BR, Bledsoe JG. Biomechanical comparison of polyaxial-type locking plates and a fixed-angle locking plate for internal fixation of distal femur fractures. J Orthop Trauma 2009; 23: 645-52.
    • (2009) J Orthop Trauma , vol.23 , pp. 645-652
    • Otto, R.J.1    Moed, B.R.2    Bledsoe, J.G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.