메뉴 건너뛰기




Volumn 87, Issue 5, 2013, Pages 1016-1021

Adaptive liver stereotactic body radiation therapy: Automated daily plan reoptimization prevents dose delivery degradation caused by anatomy deformations

Author keywords

[No Author keywords available]

Indexed keywords

COMPUTED TOMOGRAPHY SCAN; CONSTRAINT VIOLATION; INTENSITY MODULATED RADIATION THERAPY; METHODS AND MATERIALS; MULTICRITERIA OPTIMIZATION; PATIENT REPOSITIONING; PLANNING TARGET VOLUMES; STEREOTACTIC BODY RADIATION THERAPY;

EID: 84888308572     PISSN: 03603016     EISSN: 1879355X     Source Type: Journal    
DOI: 10.1016/j.ijrobp.2013.08.009     Document Type: Article
Times cited : (23)

References (29)
  • 1
    • 33748865018 scopus 로고    scopus 로고
    • Individualized image guided iso-NTCP based liver cancer SBRT
    • L.A. Dawson, C. Eccles, and T. Craig Individualized image guided iso-NTCP based liver cancer SBRT Acta Oncol 45 2006 856 864
    • (2006) Acta Oncol , vol.45 , pp. 856-864
    • Dawson, L.A.1    Eccles, C.2    Craig, T.3
  • 2
    • 33645080417 scopus 로고    scopus 로고
    • Extracranial radiosurgery (stereotactic body radiation therapy) for oligometastases
    • B.D. Kavanagh, R.C. McGarry, and R.D. Timmerman Extracranial radiosurgery (stereotactic body radiation therapy) for oligometastases Sem Radiat Oncol 16 2006 77 84
    • (2006) Sem Radiat Oncol , vol.16 , pp. 77-84
    • Kavanagh, B.D.1    McGarry, R.C.2    Timmerman, R.D.3
  • 3
    • 33748855420 scopus 로고    scopus 로고
    • Stereotactic body radiation therapy for primary and metastatic liver tumors: A single institution phase I-II study
    • R.A. Mendez, W. Wunderink, and S.M. Hussain Stereotactic body radiation therapy for primary and metastatic liver tumors: A single institution phase I-II study Acta Oncol 45 2006 831 837
    • (2006) Acta Oncol , vol.45 , pp. 831-837
    • Mendez, R.A.1    Wunderink, W.2    Hussain, S.M.3
  • 4
    • 76649108554 scopus 로고    scopus 로고
    • Stereotactic body radiation therapy for colorectal liver metastases
    • A.E. van der Pool, A.M. Romero, and W. Wunderink Stereotactic body radiation therapy for colorectal liver metastases Br J Surg 97 2009 377 382
    • (2009) Br J Surg , vol.97 , pp. 377-382
    • Van Der Pool, A.E.1    Romero, A.M.2    Wunderink, W.3
  • 5
    • 33748876430 scopus 로고    scopus 로고
    • Stereotactic radiotherapy of primary liver cancer and hepatic metastases
    • J. Wulf, M. Guckenberger, and U. Haedinger Stereotactic radiotherapy of primary liver cancer and hepatic metastases Acta Oncol 45 2006 838 847
    • (2006) Acta Oncol , vol.45 , pp. 838-847
    • Wulf, J.1    Guckenberger, M.2    Haedinger, U.3
  • 6
    • 79955025877 scopus 로고    scopus 로고
    • Phase i dose-escalation study of stereotactic body radiotherapy in patients with hepatic metastases
    • W. Rule, R. Timmerman, and L. Tong Phase I dose-escalation study of stereotactic body radiotherapy in patients with hepatic metastases Ann Surg Oncol 18 2011 1081 1087
    • (2011) Ann Surg Oncol , vol.18 , pp. 1081-1087
    • Rule, W.1    Timmerman, R.2    Tong, L.3
  • 7
    • 36348978096 scopus 로고    scopus 로고
    • Target coverage in image-guided hypofractionated radiotherapy of liver tumours
    • W. Wunderink, A. Mendez-Romero, and E. Vasquez Osorio Target coverage in image-guided hypofractionated radiotherapy of liver tumours Radiother Oncol 81 2006 S230
    • (2006) Radiother Oncol , vol.81 , pp. 230
    • Wunderink, W.1    Mendez-Romero, A.2    Vasquez Osorio, E.3
  • 8
    • 34247165049 scopus 로고    scopus 로고
    • Target coverage in image-guided stereotactic body radiotherapy of liver tumors
    • W. Wunderink, A.M. Romero, and E.M.V. Osorio Target coverage in image-guided stereotactic body radiotherapy of liver tumors Int J Radiat Oncol Biol Phys 68 2007 282 290
    • (2007) Int J Radiat Oncol Biol Phys , vol.68 , pp. 282-290
    • Wunderink, W.1    Romero, A.M.2    Osorio, E.M.V.3
  • 9
    • 84888301780 scopus 로고    scopus 로고
    • Evaluation of the positional accuracy in stereotactic radiotherapy for liver tumors using a stereotactic body frame
    • W. Wunderink, A.M.M. Romero, and J.C.J. de Boer Evaluation of the positional accuracy in stereotactic radiotherapy for liver tumors using a stereotactic body frame Radiother Oncol 73 2004 S390 S391
    • (2004) Radiother Oncol , vol.73
    • Wunderink, W.1    Romero, A.M.M.2    De Boer, J.C.J.3
  • 10
    • 70449721902 scopus 로고    scopus 로고
    • Stereotactic body radiation therapy for liver tumors: Impact of daily setup corrections and day-to-day anatomic variations on dose in target and organs at risk
    • A.M. Romero, R.T. Zinkstok, and W. Wunderink Stereotactic body radiation therapy for liver tumors: impact of daily setup corrections and day-to-day anatomic variations on dose in target and organs at risk Int J Radiat Oncol Biol Phys 75 2009 1201 1208
    • (2009) Int J Radiat Oncol Biol Phys , vol.75 , pp. 1201-1208
    • Romero, A.M.1    Zinkstok, R.T.2    Wunderink, W.3
  • 11
    • 84862660475 scopus 로고    scopus 로고
    • Accumulated dose in liver stereotactic body radiotherapy: Positioning, breathing, and deformation effects
    • M. Velec, J.L. Moseley, and T. Craig Accumulated dose in liver stereotactic body radiotherapy: Positioning, breathing, and deformation effects Int J Radiat Oncol Biol Phys 83 2012 1132 1140
    • (2012) Int J Radiat Oncol Biol Phys , vol.83 , pp. 1132-1140
    • Velec, M.1    Moseley, J.L.2    Craig, T.3
  • 12
    • 80054084236 scopus 로고    scopus 로고
    • Development of an online adaptive solution to account for inter- and intra-fractional variations
    • X.A. Li, F. Liu, and A. Tai Development of an online adaptive solution to account for inter- and intra-fractional variations Radiother Oncol 100 2011 370 374
    • (2011) Radiother Oncol , vol.100 , pp. 370-374
    • Li, X.A.1    Liu, F.2    Tai, A.3
  • 13
    • 84862815717 scopus 로고    scopus 로고
    • Characterization and management of interfractional anatomic changes for pancreatic cancer radiotherapy
    • F. Liu, B. Erickson, and C. Peng Characterization and management of interfractional anatomic changes for pancreatic cancer radiotherapy Int J Radiat Oncol Biol Phys 83 2012 e423 e429
    • (2012) Int J Radiat Oncol Biol Phys , vol.83
    • Liu, F.1    Erickson, B.2    Peng, C.3
  • 14
    • 44349097392 scopus 로고    scopus 로고
    • Reduction of respiratory liver tumor motion by abdominal compression in stereotactic body frame, analyzed by tracking fiducial markers implanted in liver
    • W. Wunderink, A.M. Romero, and W. de Kruijf Reduction of respiratory liver tumor motion by abdominal compression in stereotactic body frame, analyzed by tracking fiducial markers implanted in liver Int J Radiat Oncol Biol Phys 71 2008 907 915
    • (2008) Int J Radiat Oncol Biol Phys , vol.71 , pp. 907-915
    • Wunderink, W.1    Romero, A.M.2    De Kruijf, W.3
  • 15
    • 0027945954 scopus 로고
    • Stereotactic radiotherapy of malignancies in the abdomen. Methodological aspects
    • I. Lax, H. Blomgren, and I. Naslund Stereotactic radiotherapy of malignancies in the abdomen. Methodological aspects Acta Oncol 33 1994 677 683
    • (1994) Acta Oncol , vol.33 , pp. 677-683
    • Lax, I.1    Blomgren, H.2    Naslund, I.3
  • 16
    • 84856962314 scopus 로고    scopus 로고
    • ICycle: Integrated, multicriterial beam angle, and profile optimization for generation of coplanar and noncoplanar IMRT plans
    • S. Breedveld, P.R. Storchi, and P.W. Voet iCycle: Integrated, multicriterial beam angle, and profile optimization for generation of coplanar and noncoplanar IMRT plans Med Phys 39 2012 951 963
    • (2012) Med Phys , vol.39 , pp. 951-963
    • Breedveld, S.1    Storchi, P.R.2    Voet, P.W.3
  • 17
    • 77449086474 scopus 로고    scopus 로고
    • The equivalence of multi-criteria methods for radiotherapy plan optimization
    • S. Breedveld, P.R. Storchi, and B.J. Heijmen The equivalence of multi-criteria methods for radiotherapy plan optimization Phys Med Biol 54 2009 7199 7209
    • (2009) Phys Med Biol , vol.54 , pp. 7199-7209
    • Breedveld, S.1    Storchi, P.R.2    Heijmen, B.J.3
  • 18
    • 84865084098 scopus 로고    scopus 로고
    • On the beam direction search space in computerized non-coplanar beam angle optimization for IMRT-prostate SBRT
    • L. Rossi, S. Breedveld, and B.J. Heijmen On the beam direction search space in computerized non-coplanar beam angle optimization for IMRT-prostate SBRT Phys Med Biol 57 2012 5441 5458
    • (2012) Phys Med Biol , vol.57 , pp. 5441-5458
    • Rossi, L.1    Breedveld, S.2    Heijmen, B.J.3
  • 19
    • 84873305519 scopus 로고    scopus 로고
    • Toward fully automated multicriterial plan generation: A prospective clinical study
    • P.W. Voet, M.L. Dirkx, and S. Breedveld Toward fully automated multicriterial plan generation: A prospective clinical study Int J Radiat Oncol Biol Phys 85 2013 866 872
    • (2013) Int J Radiat Oncol Biol Phys , vol.85 , pp. 866-872
    • Voet, P.W.1    Dirkx, M.L.2    Breedveld, S.3
  • 20
    • 41449095389 scopus 로고    scopus 로고
    • The impact of respiratory motion and treatment technique on stereotactic body radiation therapy for liver cancer
    • Q.J. Wu, D. Thongphiew, and Z.H. Wang The impact of respiratory motion and treatment technique on stereotactic body radiation therapy for liver cancer Med Phys 35 2008 1440 1451
    • (2008) Med Phys , vol.35 , pp. 1440-1451
    • Wu, Q.J.1    Thongphiew, D.2    Wang, Z.H.3
  • 21
    • 77954751553 scopus 로고    scopus 로고
    • A symmetric nonrigid registration method to handle large organ deformations in cervical cancer patients
    • L. Bondar, M.S. Hoogeman, and E.M. Vasquez Osorio A symmetric nonrigid registration method to handle large organ deformations in cervical cancer patients Med Phys 37 2010 3760 3772
    • (2010) Med Phys , vol.37 , pp. 3760-3772
    • Bondar, L.1    Hoogeman, M.S.2    Vasquez Osorio, E.M.3
  • 22
    • 67649580644 scopus 로고    scopus 로고
    • A novel flexible framework with automatic feature correspondence optimization for nonrigid registration in radiotherapy
    • E.M. Vasquez Osorio, M.S. Hoogeman, and L. Bondar A novel flexible framework with automatic feature correspondence optimization for nonrigid registration in radiotherapy Med Phys 36 2009 2848 2859
    • (2009) Med Phys , vol.36 , pp. 2848-2859
    • Vasquez Osorio, E.M.1    Hoogeman, M.S.2    Bondar, L.3
  • 23
    • 79959352487 scopus 로고    scopus 로고
    • Three-dimensional dose addition of external beam radiotherapy and brachytherapy for oropharyngeal patients using nonrigid registration
    • E.M. Vasquez Osorio, M.S. Hoogeman, and D.N. Teguh Three-dimensional dose addition of external beam radiotherapy and brachytherapy for oropharyngeal patients using nonrigid registration Int J Radiat Oncol Biol Phys 80 2011 1268 1277
    • (2011) Int J Radiat Oncol Biol Phys , vol.80 , pp. 1268-1277
    • Vasquez Osorio, E.M.1    Hoogeman, M.S.2    Teguh, D.N.3
  • 24
    • 70449650381 scopus 로고    scopus 로고
    • A pre-clinical assessment of an atlas-based automatic segmentation tool for the head and neck
    • R. Sims, A. Isambert, and V. Gregoire A pre-clinical assessment of an atlas-based automatic segmentation tool for the head and neck Radiother Oncol 93 2009 474 478
    • (2009) Radiother Oncol , vol.93 , pp. 474-478
    • Sims, R.1    Isambert, A.2    Gregoire, V.3
  • 25
    • 80255135599 scopus 로고    scopus 로고
    • Clinical validation of atlasbased auto-segmentation of multiple target volumes and normal tissue (swallowing/mastication) structures in the head and neck
    • D.N. Teguh, P.C. Levendag, and P.W. Voet Clinical validation of atlasbased auto-segmentation of multiple target volumes and normal tissue (swallowing/mastication) structures in the head and neck Int J Radiat Oncol Biol Phys 81 2011 950 957
    • (2011) Int J Radiat Oncol Biol Phys , vol.81 , pp. 950-957
    • Teguh, D.N.1    Levendag, P.C.2    Voet, P.W.3
  • 26
    • 49549113402 scopus 로고    scopus 로고
    • Performance evaluation of automatic anatomy segmentation algorithm on repeat or four-dimensional computed tomography images using deformable image registration method
    • H. Wang, A.S. Garden, and L. Zhang Performance evaluation of automatic anatomy segmentation algorithm on repeat or four-dimensional computed tomography images using deformable image registration method Int J Radiat Oncol Biol Phys 72 2008 210 219
    • (2008) Int J Radiat Oncol Biol Phys , vol.72 , pp. 210-219
    • Wang, H.1    Garden, A.S.2    Zhang, L.3
  • 27
    • 34247869928 scopus 로고    scopus 로고
    • Automatic delineation of on-line head-and-neck computed tomography images: Toward on-line adaptive radiotherapy
    • T. Zhang, Y. Chi, and E. Meldolesi Automatic delineation of on-line head-and-neck computed tomography images: Toward on-line adaptive radiotherapy Int J Radiat Oncol Biol Phys 68 2007 522 530
    • (2007) Int J Radiat Oncol Biol Phys , vol.68 , pp. 522-530
    • Zhang, T.1    Chi, Y.2    Meldolesi, E.3
  • 28
    • 77955276402 scopus 로고    scopus 로고
    • A segmentation framework for abdominal organs from CT scans
    • P. Campadelli, E. Casiraghi, and S. Pratissoli A segmentation framework for abdominal organs from CT scans Artif Intell Med 50 2010 3 11
    • (2010) Artif Intell Med , vol.50 , pp. 3-11
    • Campadelli, P.1    Casiraghi, E.2    Pratissoli, S.3
  • 29
    • 79955931902 scopus 로고    scopus 로고
    • Liver tumors segmentation from CTA images using voxels classification and affinity constraint propagation
    • M. Freiman, O. Cooper, and D. Lischinski Liver tumors segmentation from CTA images using voxels classification and affinity constraint propagation Int J Comput Assist Radiol Surg 6 2011 247 255
    • (2011) Int J Comput Assist Radiol Surg , vol.6 , pp. 247-255
    • Freiman, M.1    Cooper, O.2    Lischinski, D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.