메뉴 건너뛰기




Volumn 55, Issue 11, 2013, Pages 1365-1372

Radiation dose in neuroangiography using image noise reduction technology: A population study based on 614 patients

Author keywords

Angiography; Imaging technology; Interventional neuroradiology; Radiation dose; Radiation physics

Indexed keywords

AGED; ALGORITHM; ANGIOGRAPHY; ANGIOGRAPHY DEVICE; ARTICLE; CLINICAL PRACTICE; CONTROLLED STUDY; DIGITAL SUBTRACTION ANGIOGRAPHY; FEMALE; FLUOROSCOPY; HUMAN; IMAGE NOISE REDUCTION ALGORITHM; IMAGE PROCESSING; IMAGE QUALITY; IMAGING SYSTEM; INFANT; INTERVENTIONAL RADIOLOGY; MAJOR CLINICAL STUDY; MALE; MEDICAL PROCEDURES; NEUROANGIOGRAPHY; NEUROIMAGING; NEUROPROCEDURE; NEURORADIOLOGY; PHYSICIAN; PRIORITY JOURNAL; RADIATION DOSE; RADIATION DOSE REDUCTION; RADIATION EXPOSURE; RADIODIAGNOSIS;

EID: 84888253334     PISSN: 00283940     EISSN: 14321920     Source Type: Journal    
DOI: 10.1007/s00234-013-1276-0     Document Type: Article
Times cited : (82)

References (14)
  • 1
    • 84872102860 scopus 로고    scopus 로고
    • ICRP Publication 118: ICRP statement on tissue reactions and early and late effects of radiation in normal tissues and organs - Threshold doses for tissue reactions in a radiation protection context
    • 22925378 10.1016/j.icrp.2012.02.001 1:STN:280:DC%2BC38bhs1Sqtw%3D%3D
    • Stewart FA, Akleyev AV, Hauer-Jensen M, Hendry JH, Kleiman NJ, MacVittie TJ, Aleman BM, Edgar AB, Mabuchi K, Muirhead CR, Shore RE, Wallace WH (2012) ICRP Publication 118: ICRP statement on tissue reactions and early and late effects of radiation in normal tissues and organs - threshold doses for tissue reactions in a radiation protection context. Ann ICRP 41(1-2):1-322
    • (2012) Ann ICRP , vol.41 , Issue.1-2 , pp. 1-322
    • Stewart, F.A.1    Akleyev, A.V.2    Hauer-Jensen, M.3    Hendry, J.H.4    Kleiman, N.J.5    Macvittie, T.J.6    Aleman, B.M.7    Edgar, A.B.8    Mabuchi, K.9    Muirhead, C.R.10    Shore, R.E.11    Wallace, W.H.12
  • 2
    • 84886651043 scopus 로고    scopus 로고
    • Clinical results with an image noise reduction algorithm for digital subtraction angiography
    • 10.1148/radiol.13121262 23737536
    • Söderman M, Holmin S, Andersson T, Palmgren C, Babić D, Hoornaert B (2013) Clinical results with an image noise reduction algorithm for digital subtraction angiography. Radiology. doi: 10.1148/radiol.13121262
    • (2013) Radiology
    • Söderman, M.1    Holmin, S.2    Andersson, T.3    Palmgren, C.4    Babić, D.5    Hoornaert, B.6
  • 3
    • 0035999401 scopus 로고    scopus 로고
    • Adult patient doses in interventional neuroradiology
    • 10.1118/1.1470206
    • Gkanatsios NA, Huda W, Peters KR (2012) Adult patient doses in interventional neuroradiology. Med Phys 29:717-723
    • (2012) Med Phys , vol.29 , pp. 717-723
    • Gkanatsios, N.A.1    Huda, W.2    Peters, K.R.3
  • 5
    • 83555160926 scopus 로고    scopus 로고
    • Proposed local diagnostic reference levels in angiography and interventional neuroradiology and a preliminary analysis according to the complexity of the procedures
    • 21074469 10.1016/j.ejmp.2010.10.008
    • D'Ercole L, Thyrion FZ, Bocchiola M, Mantovani L, Klersy C (2012) Proposed local diagnostic reference levels in angiography and interventional neuroradiology and a preliminary analysis according to the complexity of the procedures. Phys Med 28:61-70
    • (2012) Phys Med , vol.28 , pp. 61-70
    • D'Ercole, L.1    Thyrion, F.Z.2    Bocchiola, M.3    Mantovani, L.4    Klersy, C.5
  • 6
    • 0032823443 scopus 로고    scopus 로고
    • The potential for radiation-induced skin damage in interventional neuroradiological procedures: A review of 522 cases using automated dosimetry
    • 10505894 10.1118/1.598718
    • O'Dea TJ, Geise RA, Ritenour ER (1999) The potential for radiation-induced skin damage in interventional neuroradiological procedures: a review of 522 cases using automated dosimetry. Med Phys 26:2027-2033
    • (1999) Med Phys , vol.26 , pp. 2027-2033
    • O'Dea, T.J.1    Geise, R.A.2    Ritenour, E.R.3
  • 7
    • 84876166447 scopus 로고    scopus 로고
    • Patient radiation dose management in the follow-up of potential skin injuries in neuroradiology
    • 22859286 10.3174/ajnr.A3211 1:STN:280:DC%2BC38flt1artg%3D%3D
    • Vano E, Fernandez JM, Sanchez RM, Martinez D, Ibor LL, Gil A, Serna-Candel C (2013) Patient radiation dose management in the follow-up of potential skin injuries in neuroradiology. AJNR Am J Neuroradiol 34:277-282
    • (2013) AJNR Am J Neuroradiol , vol.34 , pp. 277-282
    • Vano, E.1    Fernandez, J.M.2    Sanchez, R.M.3    Martinez, D.4    Ibor, L.L.5    Gil, A.6    Serna-Candel, C.7
  • 8
    • 79952040220 scopus 로고    scopus 로고
    • Patient radiation exposure during diagnostic and therapeutic interventional neuroradiology procedures
    • 21990551 10.1136/jnis.2009.000802 1:STN:280:DC%2BC3MbgtlKluw%3D%3D
    • Alexander MD, Oliff MC, Olorunsola OG, Brus-Ramer M, Nickoloff EL, Meyers PM (2010) Patient radiation exposure during diagnostic and therapeutic interventional neuroradiology procedures. J Neurointerv Surg 2:6-10
    • (2010) J Neurointerv Surg , vol.2 , pp. 6-10
    • Alexander, M.D.1    Oliff, M.C.2    Olorunsola, O.G.3    Brus-Ramer, M.4    Nickoloff, E.L.5    Meyers, P.M.6
  • 10
    • 77953334270 scopus 로고    scopus 로고
    • Studies of patient doses in interventional radiological examinations
    • 20154020 10.1093/rpd/ncq021
    • Sarycheva S, Golikov V, Kalnicky S (2010) Studies of patient doses in interventional radiological examinations. Radiat Prot Dosimetry 139:258-261
    • (2010) Radiat Prot Dosimetry , vol.139 , pp. 258-261
    • Sarycheva, S.1    Golikov, V.2    Kalnicky, S.3
  • 11
    • 46749141308 scopus 로고    scopus 로고
    • Patient skin dose during neuroembolization by multiple-point measurement using a radiosensitive indicator
    • 18388215 10.3174/ajnr.A1045 1:STN:280:DC%2BD1cznsFWgsQ%3D%3D
    • Suzuki S, Furui S, Matsumaru Y, Nobuyuki S, Ebara M, Abe T, Itoh D (2008) Patient skin dose during neuroembolization by multiple-point measurement using a radiosensitive indicator. AJNR Am J Neuroradiol 29:1076-1081
    • (2008) AJNR Am J Neuroradiol , vol.29 , pp. 1076-1081
    • Suzuki, S.1    Furui, S.2    Matsumaru, Y.3    Nobuyuki, S.4    Ebara, M.5    Abe, T.6    Itoh, D.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.