메뉴 건너뛰기




Volumn 82, Issue 7, 2013, Pages

Porcine model of intracoronary pulverization of stent struts by rotablation atherectomy

Author keywords

distal embolization; rotablator; stent; vascular bed

Indexed keywords

ANIMAL EXPERIMENT; ANIMAL MODEL; ANIMAL TISSUE; ARTICLE; CONTROLLED STUDY; CORONARY BLOOD VESSEL; CORONARY STENT; ELECTROCARDIOGRAPHY; HEART; HEART ARRHYTHMIA; HEART INFARCTION; INTRACORONARY PULVERIZATION; INTRAVASCULAR ULTRASOUND; LEFT ANTERIOR DESCENDING CORONARY ARTERY; LITHOTRIPSY; MECHANICAL THROMBECTOMY; NONHUMAN; PERCUTANEOUS TRANSLUMINAL ANGIOPLASTY; ROTATIONAL ATHERECTOMY; SWINE; VASOSPASM;

EID: 84888132110     PISSN: 15221946     EISSN: 1522726X     Source Type: Journal    
DOI: 10.1002/ccd.24650     Document Type: Article
Times cited : (10)

References (21)
  • 2
    • 0023858356 scopus 로고
    • Removal of focal atheromatous lesions by angioscopically guided high-speed rotary atherectomy. Preliminary experimental observations
    • Ahn SS, Auth D, Marcus DR, Moore WS,. Removal of focal atheromatous lesions by angioscopically guided high-speed rotary atherectomy. Preliminary experimental observations. J Vasc Surg 1988; 7: 292-300.
    • (1988) J Vasc Surg , vol.7 , pp. 292-300
    • Ahn, S.S.1    Auth, D.2    Marcus, D.R.3    Moore, W.S.4
  • 3
    • 0027486574 scopus 로고
    • High frequency rotational ablation: An alternative in treating coronary artery stenoses and occlusions
    • Dietz U, Erbel R, Rupprecht HJ, Weidmann S, Meyer J,. High frequency rotational ablation: An alternative in treating coronary artery stenoses and occlusions. Br Heart J 1993; 70: 327-336.
    • (1993) Br Heart J , vol.70 , pp. 327-336
    • Dietz, U.1    Erbel, R.2    Rupprecht, H.J.3    Weidmann, S.4    Meyer, J.5
  • 4
    • 0032885179 scopus 로고    scopus 로고
    • Novel approach to rotational atherectomy results in low restenosis rates in long, calcified lesions: Long-term results of the San Antonio Rotablator Study (SARS)
    • Kiesz RS, et al. Novel approach to rotational atherectomy results in low restenosis rates in long, calcified lesions: Long-term results of the San Antonio Rotablator Study (SARS). Catheter Cardiovasc Interv 1999; 48: 48-53.
    • (1999) Catheter Cardiovasc Interv , vol.48 , pp. 48-53
    • Kiesz, R.S.1
  • 5
    • 42049103645 scopus 로고    scopus 로고
    • Rotational atherectomy followed by drug-eluting stent implantation (Rota-DES): A rational approach for complex calcified coronary lesions
    • Khattab AA, Richardt G,. Rotational atherectomy followed by drug-eluting stent implantation (Rota-DES): A rational approach for complex calcified coronary lesions. Minerva Cardioangiol 2008; 56: 107-115.
    • (2008) Minerva Cardioangiol , vol.56 , pp. 107-115
    • Khattab, A.A.1    Richardt, G.2
  • 6
    • 38349114040 scopus 로고    scopus 로고
    • Effects of sirolimus-eluting stent on calcified coronary lesions
    • Li JJ, et al. Effects of sirolimus-eluting stent on calcified coronary lesions. Chin Med J (Engl) 2008; 121: 6-11.
    • (2008) Chin Med J (Engl) , vol.121 , pp. 6-11
    • Li, J.J.1
  • 7
    • 0030939283 scopus 로고    scopus 로고
    • A case of favorable dilation of protected left main coronary artery lesion achieved through performance of adjunctive DCA on residual stenosis following use of rotablator
    • Taniguchi M, et al. A case of favorable dilation of protected left main coronary artery lesion achieved through performance of adjunctive DCA on residual stenosis following use of rotablator. Angiology 1997; 48: 529-534.
    • (1997) Angiology , vol.48 , pp. 529-534
    • Taniguchi, M.1
  • 8
    • 72649083204 scopus 로고    scopus 로고
    • Rotational atherectomy is useful to treat restenosis lesions due to crushing of a sirolimus-eluting stent implanted in severely calcified lesions: Experimental study and initial clinical experience
    • Okamura A, Ito H, Fujii K,. Rotational atherectomy is useful to treat restenosis lesions due to crushing of a sirolimus-eluting stent implanted in severely calcified lesions: Experimental study and initial clinical experience. J Invasive Cardiol 2009; 21: E191-E196.
    • (2009) J Invasive Cardiol , vol.21
    • Okamura, A.1    Ito, H.2    Fujii, K.3
  • 9
    • 0023938385 scopus 로고
    • Rotational endarterectomy in normal canine coronary arteries: Preliminary report
    • Hansen DD, Auth DC, Hall M, Ritchie JL,. Rotational endarterectomy in normal canine coronary arteries: Preliminary report. J Am Coll Cardiol 1988; 11: 1073-1077.
    • (1988) J Am Coll Cardiol , vol.11 , pp. 1073-1077
    • Hansen, D.D.1    Auth, D.C.2    Hall, M.3    Ritchie, J.L.4
  • 10
    • 40649106064 scopus 로고    scopus 로고
    • Very very late thrombosis of a sirolimus-eluting stent: Does suboptimal stent expansion take its toll even after three years?
    • Bollati M, Biondi-Zoccai GG, Gambino A, Lombardi P, Sheiban I,. Very very late thrombosis of a sirolimus-eluting stent: Does suboptimal stent expansion take its toll even after three years? J Cardiovasc Med (Hagerstown) 2008; 9: 403-405.
    • (2008) J Cardiovasc Med (Hagerstown) , vol.9 , pp. 403-405
    • Bollati, M.1    Biondi-Zoccai, G.G.2    Gambino, A.3    Lombardi, P.4    Sheiban, I.5
  • 11
    • 77953113676 scopus 로고    scopus 로고
    • Effects of distal embolization on the timing of platelet and inflammatory cell activation in interventional coronary no-reflow
    • Charron T, et al. Effects of distal embolization on the timing of platelet and inflammatory cell activation in interventional coronary no-reflow. Thromb Res 2010; 126: 50-55.
    • (2010) Thromb Res , vol.126 , pp. 50-55
    • Charron, T.1
  • 12
    • 0024460492 scopus 로고
    • Percutaneous coronary rotational angioplasty in humans: Preliminary report
    • Fourrier JL, et al. Percutaneous coronary rotational angioplasty in humans: preliminary report. J Am Coll Cardiol 1989; 14: 1278-1282.
    • (1989) J Am Coll Cardiol , vol.14 , pp. 1278-1282
    • Fourrier, J.L.1
  • 14
    • 0026720842 scopus 로고
    • High-speed rotational angioplasty-induced echo contrast in vivo and in vitro optical analysis
    • Zotz RJ, et al. High-speed rotational angioplasty-induced echo contrast in vivo and in vitro optical analysis. Cathet Cardiovasc Diagn 1992; 26: 98-109.
    • (1992) Cathet Cardiovasc Diagn , vol.26 , pp. 98-109
    • Zotz, R.J.1
  • 15
    • 0025945560 scopus 로고
    • Percutaneous coronary rotational angioplasty: Preliminary clinical and quantitative imaging results
    • Laarman GJ, Serruys PW,. Percutaneous coronary rotational angioplasty: preliminary clinical and quantitative imaging results. Int J Card Imaging 1991; 7: 47-54.
    • (1991) Int J Card Imaging , vol.7 , pp. 47-54
    • Laarman, G.J.1    Serruys, P.W.2
  • 17
    • 60749113184 scopus 로고    scopus 로고
    • Coronary no-reflow phenomenon: From the experimental laboratory to the cardiac catheterization laboratory
    • Rezkalla SH, Kloner RA,. Coronary no-reflow phenomenon: from the experimental laboratory to the cardiac catheterization laboratory. Catheter Cardiovasc Interv 2008; 72: 950-957.
    • (2008) Catheter Cardiovasc Interv , vol.72 , pp. 950-957
    • Rezkalla, S.H.1    Kloner, R.A.2
  • 18
    • 48249115694 scopus 로고    scopus 로고
    • Microvascular obstruction and the no-reflow phenomenon after percutaneous coronary intervention
    • Jaffe R, Charron T, Puley G, Dick A, Strauss BH,. Microvascular obstruction and the no-reflow phenomenon after percutaneous coronary intervention. Circulation 2008; 117: 3152-3156.
    • (2008) Circulation , vol.117 , pp. 3152-3156
    • Jaffe, R.1    Charron, T.2    Puley, G.3    Dick, A.4    Strauss, B.H.5
  • 19
    • 0022454592 scopus 로고
    • Role of adenosine in hyperemic response of coronary blood flow in microembolization
    • Hori M, et al. Role of adenosine in hyperemic response of coronary blood flow in microembolization. Am J Physiol 1986; 250: H509-H518.
    • (1986) Am J Physiol , vol.250
    • Hori, M.1
  • 20
    • 11844258888 scopus 로고    scopus 로고
    • Detection of embolic particles with the Doppler guide wire during coronary intervention in patients with acute myocardial infarction: Efficacy of distal protection device
    • Okamura A, et al. Detection of embolic particles with the Doppler guide wire during coronary intervention in patients with acute myocardial infarction: Efficacy of distal protection device. J Am Coll Cardiol 2005; 45: 212-215.
    • (2005) J Am Coll Cardiol , vol.45 , pp. 212-215
    • Okamura, A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.