메뉴 건너뛰기




Volumn 21, Issue 10, 2009, Pages

Rotational atherectomy is useful to treat restenosis lesions due to crushing of a sirolimus-eluting stent implanted in severely calcified lesions: Experimental study and initial clinical experience

Author keywords

[No Author keywords available]

Indexed keywords

RAPAMYCIN;

EID: 72649083204     PISSN: 10423931     EISSN: 15572501     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (16)

References (12)
  • 1
    • 0037030658 scopus 로고    scopus 로고
    • A randomized comparison of a sirolimus-eluting stent with a standard stent for coronary revascularization
    • RAVEL Study Group
    • Morice MC, Serruys PW, Sousa JE, et al; RAVEL Study Group. A randomized comparison of a sirolimus-eluting stent with a standard stent for coronary revascularization. N Engl J Med 2002;346:1773-1780.
    • (2002) N Engl J Med , vol.346 , pp. 1773-1780
    • Morice, M.C.1    Serruys, P.W.2    Sousa, J.E.3
  • 2
    • 0141863201 scopus 로고    scopus 로고
    • Sirolimus-eluting stents for treatment of patients with long atherosclerotic lesions in small coronary arteries: Double-blind, randomised controlled trial (E-SIRIUS)
    • E-SIRIUS Investigators
    • Schofer J, Schlüter M, Gershlick AH, et al; E-SIRIUS Investigators. Sirolimus-eluting stents for treatment of patients with long atherosclerotic lesions in small coronary arteries: double-blind, randomised controlled trial (E-SIRIUS). Lancet 2003;362:1093-1099.
    • (2003) Lancet , vol.362 , pp. 1093-1099
    • Schofer, J.1    Schlüter, M.2    Gershlick, A.H.3
  • 3
    • 0041807644 scopus 로고    scopus 로고
    • Coronary restenosis after sirolimus-eluting stent implantation: Morphological description and mechanistic analysis from a consecutive series of cases
    • Lemos PA, Saia F, Ligthart JM, et al. Coronary restenosis after sirolimus-eluting stent implantation: morphological description and mechanistic analysis from a consecutive series of cases. Circulation 2003;108:257-260.
    • (2003) Circulation , vol.108 , pp. 257-260
    • Lemos, P.A.1    Saia, F.2    Ligthart, J.M.3
  • 4
    • 0346732102 scopus 로고    scopus 로고
    • Stent fracture and restenosis in the drug-eluting stent era
    • Sianos G, Hofma S, Ligthart JM, et al. Stent fracture and restenosis in the drug-eluting stent era. Catheter Cardiovasc Interv 2004;61:111-116.
    • (2004) Catheter Cardiovasc Interv , vol.61 , pp. 111-116
    • Sianos, G.1    Hofma, S.2    Ligthart, J.M.3
  • 5
    • 33847405288 scopus 로고    scopus 로고
    • Stent fracture associated with drug-eluting stents: Clinical characteristics and implications
    • Lee MS, Jurewitz D, Aragon J, et al. Stent fracture associated with drug-eluting stents: Clinical characteristics and implications. Catheter Cardiovasc Interv 2007;69:387-394.
    • (2007) Catheter Cardiovasc Interv , vol.69 , pp. 387-394
    • Lee, M.S.1    Jurewitz, D.2    Aragon, J.3
  • 6
    • 37249013493 scopus 로고    scopus 로고
    • Comparative analysis of the particle size and shape of commercially available mineral trioxide aggregates and Portland cement: A study with a flow particle image analyzer
    • Komabayashi T, Spångberg LS. Comparative analysis of the particle size and shape of commercially available mineral trioxide aggregates and Portland cement: a study with a flow particle image analyzer. J Endod 2008;34:94-98.
    • (2008) J Endod , vol.34 , pp. 94-98
    • Komabayashi, T.1    Spångberg, L.S.2
  • 7
    • 33847339687 scopus 로고    scopus 로고
    • Incidence and clinical impact of coronary stent fracture after sirolimus-eluting stent implantation
    • Aoki J, Nakazawa G, Tanabe K, et al. Incidence and clinical impact of coronary stent fracture after sirolimus-eluting stent implantation. Catheter Cardiovasc Interv 2007;69:380-386.
    • (2007) Catheter Cardiovasc Interv , vol.69 , pp. 380-386
    • Aoki, J.1    Nakazawa, G.2    Tanabe, K.3
  • 8
    • 0030834972 scopus 로고    scopus 로고
    • New technique for stent jail: Another niche for the rotablator
    • Abdelmeguid AE. New technique for stent jail: another niche for the rotablator. Cathet Cardiovasc Diagn 1997;42:321-324.
    • (1997) Cathet Cardiovasc Diagn , vol.42 , pp. 321-324
    • Abdelmeguid, A.E.1
  • 9
    • 0035141117 scopus 로고    scopus 로고
    • Rotational atherectomy (stentablation) in a lesion with stent underexpansion due to heavily calcified plaque
    • Kobayashi Y, Teirstein P, Linnemeier T, et al. Rotational atherectomy (stentablation) in a lesion with stent underexpansion due to heavily calcified plaque. Catheter Cardiovasc Interv 2001;52:208-211.
    • (2001) Catheter Cardiovasc Interv , vol.52 , pp. 208-211
    • Kobayashi, Y.1    Teirstein, P.2    Linnemeier, T.3
  • 11
    • 0023831535 scopus 로고
    • Rotational atherectomy in atherosclerotic rabbit iliac arteries
    • Hansen DD, Auth DC, Vracko R, Ritchie JL. Rotational atherectomy in atherosclerotic rabbit iliac arteries. Am Heart J 1988;115:160-165.
    • (1988) Am Heart J , vol.115 , pp. 160-165
    • Hansen, D.D.1    Auth, D.C.2    Vracko, R.3    Ritchie, J.L.4
  • 12
    • 0023938385 scopus 로고
    • Rotational endarterectomy in normal canine coronary arteries: Preliminary report
    • Hansen DD, Auth DC, Hall M, Ritchie JL. Rotational endarterectomy in normal canine coronary arteries: preliminary report. J Am Coll Cardiol 1988;11:1073-1077.
    • (1988) J Am Coll Cardiol , vol.11 , pp. 1073-1077
    • Hansen, D.D.1    Auth, D.C.2    Hall, M.3    Ritchie, J.L.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.