Volumn 40, Issue 12, 2013, Pages 1869-1875

Gated SPECT evaluation of left ventricular function using a CZT camera and a fast low-dose clinical protocol: Comparison to cardiac magnetic resonance imaging

Author keywords

cMRI; CZT; Gated SPECT; Left ventricular function; Radiotracer low dose

Indexed keywords

CADMIUM; CADMIUM ZINC TELLURIDE; TELLURIUM; TETROFOSMIN TC 99M; UNCLASSIFIED DRUG; ZINC;

EID: 84888010478     PISSN: 16197070     EISSN: 16197089     Source Type: Journal    
DOI: 10.1007/s00259-013-2505-9     Document Type: Article
Times cited : (39)

References (20)
  • 1
    • 79851487935 scopus 로고    scopus 로고
    • Cardiac dedicated ultrafast SPECT cameras: New designs and clinical implications
    • 21233190 10.2967/jnumed.110.081323
    • Garcia EV, Faber TL, Esteves FP. Cardiac dedicated ultrafast SPECT cameras: new designs and clinical implications. J Nucl Med. 2011;52:210-7.
    • (2011) J Nucl Med , vol.52 , pp. 210-217
    • Garcia, E.V.1    Faber, T.L.2    Esteves, F.P.3
  • 2
    • 72249112561 scopus 로고    scopus 로고
    • Novel solid-state-detector dedicated cardiac camera for fast myocardial perfusion imaging: Multicenter comparison with standard dual detector cameras
    • 19688410 10.1007/s12350-009-9137-2
    • Esteves FP, Raggi P, Folks RD, Keidar Z, Askew JW, Rispler S, et al. Novel solid-state-detector dedicated cardiac camera for fast myocardial perfusion imaging: multicenter comparison with standard dual detector cameras. J Nucl Cardiol. 2009;16:927-34.
    • (2009) J Nucl Cardiol , vol.16 , pp. 927-934
    • Esteves, F.P.1    Raggi, P.2    Folks, R.D.3    Keidar, Z.4    Askew, J.W.5    Rispler, S.6
  • 3
    • 83255192159 scopus 로고    scopus 로고
    • Reduced isotope dose and imaging time with a high-efficiency CZT SPECT camera
    • 21528422 10.1007/s12350-011-9379-7
    • Duvall WL, Croft LB, Ginsberg ES, Einstein AJ, Guma KA, George T, et al. Reduced isotope dose and imaging time with a high-efficiency CZT SPECT camera. J Nucl Cardiol. 2011;18:847-57.
    • (2011) J Nucl Cardiol , vol.18 , pp. 847-857
    • Duvall, W.L.1    Croft, L.B.2    Ginsberg, E.S.3    Einstein, A.J.4    Guma, K.A.5    George, T.6
  • 4
    • 84858722340 scopus 로고    scopus 로고
    • High diagnostic accuracy of low-dose gated-SPECT with solid-state ultrafast detectors: Preliminary clinical results
    • 21887532 10.1007/s00259-011-1918-6 1:CAS:528:DC%2BC3MXhsFOgt7nJ
    • Gimelli A, Bottai M, Genovesi D, Giorgetti A, Di Martino F, Marzullo P. High diagnostic accuracy of low-dose gated-SPECT with solid-state ultrafast detectors: preliminary clinical results. Eur J Nucl Med Mol Imaging. 2012;39(1):83-90.
    • (2012) Eur J Nucl Med Mol Imaging , vol.39 , Issue.1 , pp. 83-90
    • Gimelli, A.1    Bottai, M.2    Genovesi, D.3    Giorgetti, A.4    Di Martino, F.5    Marzullo, P.6
  • 5
    • 84869039406 scopus 로고    scopus 로고
    • Nuclear cardiology at the door of a new era: Better to save mSv or to reduce imaging time?
    • 22949080 10.1007/s00259-012-2238-1
    • Giorgetti A, Genovesi D, Marzullo P. Nuclear cardiology at the door of a new era: better to save mSv or to reduce imaging time? Eur J Nucl Med Mol Imaging. 2012;39(12):1898-900.
    • (2012) Eur J Nucl Med Mol Imaging , vol.39 , Issue.12 , pp. 1898-1900
    • Giorgetti, A.1    Genovesi, D.2    Marzullo, P.3
  • 6
    • 0030810148 scopus 로고    scopus 로고
    • Automatic quantitation of regional myocardial wall motion and thickening from gated technetium-99m sestamibi myocardial perfusion single-photon emission computed tomography
    • 9350940 10.1016/S0735-1097(97)00276-3 1:STN:280:DyaK1c%2FhtVChsQ%3D%3D
    • Germano G, Erel J, Lewin H, Kavanagh PB, Berman DS. Automatic quantitation of regional myocardial wall motion and thickening from gated technetium-99m sestamibi myocardial perfusion single-photon emission computed tomography. J Am Coll Cardiol. 1997;30(5):1360-7.
    • (1997) J Am Coll Cardiol , vol.30 , Issue.5 , pp. 1360-1367
    • Germano, G.1    Erel, J.2    Lewin, H.3    Kavanagh, P.B.4    Berman, D.S.5
  • 7
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical assessment
    • 2868172 10.1016/S0140-6736(86)90837-8 1:STN:280:DyaL287hslWqsQ%3D%3D
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical assessment. Lancet. 1986;1:307-10.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 8
    • 0018375301 scopus 로고
    • Variables predictive of survival in patients with coronary disease. Selection by univariate and multivariate analyses from the clinical, electrocardiographic, exercise, arteriographic, and quantitative angiographic evaluations
    • 761323 10.1161/01.CIR.59.3.421 1:STN:280:DyaE1M7gsFOrtA%3D%3D
    • Hammermeister KE, de Rouen TA, Dodge HT. Variables predictive of survival in patients with coronary disease. Selection by univariate and multivariate analyses from the clinical, electrocardiographic, exercise, arteriographic, and quantitative angiographic evaluations. Circulation. 1979;59:421-30.
    • (1979) Circulation , vol.59 , pp. 421-430
    • Hammermeister, K.E.1    De Rouen, T.A.2    Dodge, H.T.3
  • 9
    • 79958175854 scopus 로고    scopus 로고
    • Evaluation of left ventricular function using cardiac magnetic resonance imaging
    • 21234827 10.1007/s12350-010-9334-z
    • Grover S, Leong DL, Selvanayagam JB. Evaluation of left ventricular function using cardiac magnetic resonance imaging. J Nucl Cardiol. 2011;18:351-65.
    • (2011) J Nucl Cardiol , vol.18 , pp. 351-365
    • Grover, S.1    Leong, D.L.2    Selvanayagam, J.B.3
  • 10
    • 0034796989 scopus 로고    scopus 로고
    • Accuracy of ventricular volume and ejection fraction measured by gated myocardial SPECT: Comparison of 4 software programs
    • 11585875 1:STN:280:DC%2BD3MrjvFSrsg%3D%3D
    • Nakajima K, Higuchi T, Taki J, Kawano M, Tonami N. Accuracy of ventricular volume and ejection fraction measured by gated myocardial SPECT: comparison of 4 software programs. J Nucl Med. 2001;42:1571-8.
    • (2001) J Nucl Med , vol.42 , pp. 1571-1578
    • Nakajima, K.1    Higuchi, T.2    Taki, J.3    Kawano, M.4    Tonami, N.5
  • 11
    • 0033753105 scopus 로고    scopus 로고
    • Left ventricular function: Correlation of quantitative gated SPECT and MR imaging over a wide range of values
    • 11058662 10.1148/radiology.217.2.r00nv15572 1:STN:280: DC%2BD3crhtFChsw%3D%3D
    • Bavelaar-Croon CDL, Kayser HWM, van der Wall EE, de Roos A, Dibbets-Schneider P, Pauwels EK, et al. Left ventricular function: correlation of quantitative gated SPECT and MR imaging over a wide range of values. Radiology. 2000;217:572-5.
    • (2000) Radiology , vol.217 , pp. 572-575
    • Bavelaar-Croon, C.D.L.1    Kayser, H.W.M.2    Van Der Wall, E.E.3    De Roos, A.4    Dibbets-Schneider, P.5    Pauwels, E.K.6
  • 12
    • 0034672579 scopus 로고    scopus 로고
    • Comparison of gated single-photon emission computed tomography with magnetic resonance imaging for evaluation of left ventricular function in ischemic cardiomyopathy
    • 11113402 10.1016/S0002-9149(00)01231-5 1:STN:280:DC%2BD3M%2FpvFymsg%3D%3D
    • Bax JJ, Lamb H, Dibbets P, Pelikan H, Boersma E, Viergever EP, et al. Comparison of gated single-photon emission computed tomography with magnetic resonance imaging for evaluation of left ventricular function in ischemic cardiomyopathy. Am J Cardiol. 2000;86:1299-305.
    • (2000) Am J Cardiol , vol.86 , pp. 1299-1305
    • Bax, J.J.1    Lamb, H.2    Dibbets, P.3    Pelikan, H.4    Boersma, E.5    Viergever, E.P.6
  • 13
    • 18044368618 scopus 로고    scopus 로고
    • Evaluation of left ventricular endocardial volumes and ejection fractions computed from gated perfusion SPECT with magnetic imaging: Comparison of two methods
    • 11725260 10.1067/mnc.2001.117173 1:STN:280:DC%2BD3MnnvVyqsg%3D%3D
    • Faber TL, Vansant JP, Pettigrew RI, Galt JR, Blais M, Chatzimavroudis G, et al. Evaluation of left ventricular endocardial volumes and ejection fractions computed from gated perfusion SPECT with magnetic imaging: comparison of two methods. J Nucl Cardiol. 2001;8:645-51.
    • (2001) J Nucl Cardiol , vol.8 , pp. 645-651
    • Faber, T.L.1    Vansant, J.P.2    Pettigrew, R.I.3    Galt, J.R.4    Blais, M.5    Chatzimavroudis, G.6
  • 14
    • 0033034954 scopus 로고    scopus 로고
    • Evaluation of left ventricular wall motion, volumes, and ejection fraction by gated myocardial tomography with technetium 99m-labeled tetrofosmin: A comparison with cine magnetic resonance imaging
    • 10.1016/S1071-3581(99)90058-2
    • Vaduganathan P, He Z, Vick III GW, Mahmarian JJ, Verani MS. Evaluation of left ventricular wall motion, volumes, and ejection fraction by gated myocardial tomography with technetium 99m-labeled tetrofosmin: a comparison with cine magnetic resonance imaging. J Nucl Cardiol. 1998;6:3-10.
    • (1998) J Nucl Cardiol , vol.6 , pp. 3-10
    • Vaduganathan, P.1    He, Z.2    Vick III, G.W.3    Mahmarian, J.J.4    Verani, M.S.5
  • 15
    • 1842815742 scopus 로고    scopus 로고
    • Validation of 4D-MSPECT and QGS for quantification of left ventricular volumes and ejection fraction from gated Tc-MIBI SPET: Comparison with cardiac magnetic resonance imaging
    • 14722679 10.1007/s00259-003-1411-y
    • Lipke CSA, Kühl HP, Nowak B, Kaiser HJ, Reinartz P, Buell U, et al. Validation of 4D-MSPECT and QGS for quantification of left ventricular volumes and ejection fraction from gated Tc-MIBI SPET: comparison with cardiac magnetic resonance imaging. Eur J Nucl Med Mol Imaging. 2004;31:482-90.
    • (2004) Eur J Nucl Med Mol Imaging , vol.31 , pp. 482-490
    • Lipke, C.S.A.1    Kühl, H.P.2    Nowak, B.3    Kaiser, H.J.4    Reinartz, P.5    Buell, U.6
  • 16
    • 0033858106 scopus 로고    scopus 로고
    • Gated SPET quantification of small hearts: Mathematical simulation and clinical application
    • 11007520 10.1007/s002590000299 1:STN:280:DC%2BD3cvltFygsA%3D%3D
    • Nakajima K, Taki J, Higuchi T, Kawano M, Taniguchi M, Maruhashi K, et al. Gated SPET quantification of small hearts: mathematical simulation and clinical application. Eur J Nucl Med. 2000;27:1372-9.
    • (2000) Eur J Nucl Med , vol.27 , pp. 1372-1379
    • Nakajima, K.1    Taki, J.2    Higuchi, T.3    Kawano, M.4    Taniguchi, M.5    Maruhashi, K.6
  • 17
    • 33747167581 scopus 로고    scopus 로고
    • Prognostic value of poststress left ventricular volume and ejection fraction by gated myocardial perfusion SPECT in women and men: Gender-related differences in normal limits and outcomes
    • 16919573 10.1016/j.nuclcard.2006.03.019
    • Sharir T, Kang X, Germano G, Bax JJ, Shaw LJ, Gransar H, et al. Prognostic value of poststress left ventricular volume and ejection fraction by gated myocardial perfusion SPECT in women and men: gender-related differences in normal limits and outcomes. J Nucl Cardiol. 2006;13:495-506.
    • (2006) J Nucl Cardiol , vol.13 , pp. 495-506
    • Sharir, T.1    Kang, X.2    Germano, G.3    Bax, J.J.4    Shaw, L.J.5    Gransar, H.6
  • 18
    • 38649112655 scopus 로고    scopus 로고
    • Effect of sex, age, and weight on ejection fraction and end-systolic volume reference limits in gated myocardial perfusion SPECT
    • 18242484 10.1016/j.nuclcard.2007.10.004
    • Peace RA, Adams PC, Lloyd JJ. Effect of sex, age, and weight on ejection fraction and end-systolic volume reference limits in gated myocardial perfusion SPECT. J Nucl Cardiol. 2008;15:86-93.
    • (2008) J Nucl Cardiol , vol.15 , pp. 86-93
    • Peace, R.A.1    Adams, P.C.2    Lloyd, J.J.3
  • 19
    • 0033558696 scopus 로고    scopus 로고
    • Assessment of regional and global left ventricular function by reinjection Tl-201 and rest Tc-99m sestamibi ECG-gated SPECT: Comparison with three-dimensional magnetic resonance imaging
    • 10091826 10.1016/S0735-1097(98)00661-5 1:STN:280:DyaK1M7ptVantQ%3D%3D
    • Tadamura E, Kudoh T, Motooka M, Inubushi M, Shirakawa S, Hattori N, et al. Assessment of regional and global left ventricular function by reinjection Tl-201 and rest Tc-99m sestamibi ECG-gated SPECT: comparison with three-dimensional magnetic resonance imaging. J Am Coll Cardiol. 1999;33:991-7.
    • (1999) J Am Coll Cardiol , vol.33 , pp. 991-997
    • Tadamura, E.1    Kudoh, T.2    Motooka, M.3    Inubushi, M.4    Shirakawa, S.5    Hattori, N.6
  • 20
    • 84875791776 scopus 로고    scopus 로고
    • Absolute quantification of left ventricular global and regional function at nuclear MPI using ultrafast CZT SPECT: Initial validation versus cardiac MR
    • 23385955 10.2967/jnumed.112.110577
    • Cochet H, Bullier E, Gerbaud E, Durieux M, Godbert Y, Lederlin M, et al. Absolute quantification of left ventricular global and regional function at nuclear MPI using ultrafast CZT SPECT: initial validation versus cardiac MR. J Nucl Med. 2013;54(4):556-63.
    • (2013) J Nucl Med , vol.54 , Issue.4 , pp. 556-563
    • Cochet, H.1    Bullier, E.2    Gerbaud, E.3    Durieux, M.4    Godbert, Y.5    Lederlin, M.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.