메뉴 건너뛰기




Volumn 191, Issue , 2014, Pages 522-528

An interference-free glucose biosensor based on a novel low potential redox polymer mediator

Author keywords

Biosensor; Glassy carbon; Glucose; Redox polymer; Ruthenium

Indexed keywords

AMINES; ASCORBIC ACID; BIOSENSORS; CATALYST ACTIVITY; CATALYTIC OXIDATION; CROSSLINKING; GLASS; GLASS MEMBRANE ELECTRODES; GLASSY CARBON; GLUCOSE; GLUCOSE SENSORS; MOLECULAR OXYGEN; OXIDATION; RUTHENIUM; RUTHENIUM COMPOUNDS;

EID: 84887482922     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2013.10.059     Document Type: Article
Times cited : (71)

References (43)
  • 1
    • 84873676829 scopus 로고    scopus 로고
    • Adsorptive stripping voltammetric determination of imipramine, trimipramine and desipramine employing titanium dioxide nanoparticles and an Amberlite XAD-2 modified glassy carbon paste electrode
    • B.J. Sanghavi, and A.K. Srivastava Adsorptive stripping voltammetric determination of imipramine, trimipramine and desipramine employing titanium dioxide nanoparticles and an Amberlite XAD-2 modified glassy carbon paste electrode Analyst 138 2013 1395 1404
    • (2013) Analyst , vol.138 , pp. 1395-1404
    • Sanghavi, B.J.1    Srivastava, A.K.2
  • 2
    • 78049244463 scopus 로고    scopus 로고
    • Simultaneous voltammetric determination of acetaminophen, aspirin and caffeine using an in situ surfactant-modified multiwalled carbon nanotube paste electrode
    • B.J. Sanghavi, and A.K. Srivastava Simultaneous voltammetric determination of acetaminophen, aspirin and caffeine using an in situ surfactant-modified multiwalled carbon nanotube paste electrode Electrochim. Acta 55 2010 8638 8648
    • (2010) Electrochim. Acta , vol.55 , pp. 8638-8648
    • Sanghavi, B.J.1    Srivastava, A.K.2
  • 3
    • 79954583931 scopus 로고    scopus 로고
    • Adsorptive stripping differential pulse voltammetric determination of venlafaxine and desvenlafaxine employing Nafion-carbon nanotube composite glassy carbon electrode
    • B.J. Sanghavi, and A.K. Srivastava Adsorptive stripping differential pulse voltammetric determination of venlafaxine and desvenlafaxine employing Nafion-carbon nanotube composite glassy carbon electrode Electrochim. Acta 56 2011 4188 4196
    • (2011) Electrochim. Acta , vol.56 , pp. 4188-4196
    • Sanghavi, B.J.1    Srivastava, A.K.2
  • 4
    • 10244223555 scopus 로고
    • Electrode systems for continuous monitoring in cardiovascular surgery
    • L.C. Clark, and C. Lyons Electrode systems for continuous monitoring in cardiovascular surgery Ann. N. Y. Acad. Sci. 102 1962 29 45
    • (1962) Ann. N. Y. Acad. Sci. , vol.102 , pp. 29-45
    • Clark, L.C.1    Lyons, C.2
  • 5
    • 0025671780 scopus 로고
    • Glucose fast-response amperometric sensor based on glucose oxidase immobilized in an electropolymerized poly(ortophenylenediamine) film
    • C. Malitesta, F. Palmisano, L. Torsi, and P.G. Zambonin Glucose fast-response amperometric sensor based on glucose oxidase immobilized in an electropolymerized poly(ortophenylenediamine) film Anal. Chem. 62 1990 2735 2740
    • (1990) Anal. Chem. , vol.62 , pp. 2735-2740
    • Malitesta, C.1    Palmisano, F.2    Torsi, L.3    Zambonin, P.G.4
  • 6
    • 0034253312 scopus 로고    scopus 로고
    • Materials and techniques for electrochemical biosensor design and construction
    • S. Zhang, G. Wright, and Y. Yang Materials and techniques for electrochemical biosensor design and construction Biosens. Bioelectron. 15 2000 273 282
    • (2000) Biosens. Bioelectron. , vol.15 , pp. 273-282
    • Zhang, S.1    Wright, G.2    Yang, Y.3
  • 8
    • 77954855173 scopus 로고    scopus 로고
    • Electrochemistry in diabetes management
    • A. Heller, and B. Feldman Electrochemistry in diabetes management Acc. Chem. Res. 43 2010 963 973
    • (2010) Acc. Chem. Res. , vol.43 , pp. 963-973
    • Heller, A.1    Feldman, B.2
  • 9
    • 25144460759 scopus 로고    scopus 로고
    • A disposable glucose biosensor based on diffusional mediator dispersed in nanoparticulate membrane on screen-printed carbon electrode
    • DOI 10.1016/j.snb.2004.12.008, PII S0925400504008482
    • Z.Q. Gao, F. Xie, M.S.M. Arshad, and J.Y. Ying A disposable glucose biosensor based on diffusional mediator dispersed in nanoparticulate membrane on screen-printed carbon electrode Sens. Actuators B: Chem. 111 2005 339 346 (Pubitemid 41354885)
    • (2005) Sensors and Actuators, B: Chemical , vol.111-112 , Issue.SUPPL. , pp. 339-346
    • Gao, Z.1    Xie, F.2    Shariff, M.3    Arshad, M.4    Ying, J.Y.5
  • 10
    • 46549086907 scopus 로고    scopus 로고
    • A sensitive biosensor based on Os-complex mediator and glucose oxidase for low concentration glucose determination
    • L.Y. Jiang, H.M. Liu, J. Liu, Q.D. Yang, and X.X. Cai A sensitive biosensor based on Os-complex mediator and glucose oxidase for low concentration glucose determination J. Electroanal. Chem. 619 2008 11 16
    • (2008) J. Electroanal. Chem. , vol.619 , pp. 11-16
    • Jiang, L.Y.1    Liu, H.M.2    Liu, J.3    Yang, Q.D.4    Cai, X.X.5
  • 11
    • 0031164717 scopus 로고    scopus 로고
    • ISFET glucose and sucrose sensors by using platinum electrode and photo-crosslinkable polymers
    • B.K. Sohn, B.W. Cho, C.S. Kim, and D.H. Kwon ISFET glucose and sucrose sensors by using platinum electrode and photo-crosslinkable polymers Sens. Actuators B: Chem. 41 1997 7 11
    • (1997) Sens. Actuators B: Chem. , vol.41 , pp. 7-11
    • Sohn, B.K.1    Cho, B.W.2    Kim, C.S.3    Kwon, D.H.4
  • 13
    • 33749992178 scopus 로고    scopus 로고
    • A novel method for glucose determination based on electrochemical impedance spectroscopy using glucose oxidase self-assembled biosensor
    • DOI 10.1016/j.bioelechem.2006.01.003, PII S1567539406000089
    • R.K. Shervedani, A.H. Mehrjardi, and N. Zamir A novel method for glucose determination based on electrochemical impedance spectroscopy using glucose oxidase self-assembled biosensor Bioelectrochemistry 69 2006 201 208 (Pubitemid 44572982)
    • (2006) Bioelectrochemistry , vol.69 , Issue.2 , pp. 201-208
    • Shervedani, R.K.1    Mehrjardi, A.H.2    Zamiri, N.3
  • 14
    • 79955591989 scopus 로고    scopus 로고
    • An impedimetric glucose biosensor based on overoxidized polypyrrole thin film
    • D. Zane, G.B. Appetecchi, C. Bianchini, S. Passerini, and A. Curulli An impedimetric glucose biosensor based on overoxidized polypyrrole thin film Electroanalysis 23 2011 1134 1141
    • (2011) Electroanalysis , vol.23 , pp. 1134-1141
    • Zane, D.1    Appetecchi, G.B.2    Bianchini, C.3    Passerini, S.4    Curulli, A.5
  • 15
    • 0022138056 scopus 로고
    • Two-dimensional enzyme electrode sensor for glucose
    • D.A. Gough, J.Y. Lucisano, and P.H.S. Tze Two-dimensional enzyme electrode sensor for glucose Anal. Chem. 57 1985 2351 2357
    • (1985) Anal. Chem. , vol.57 , pp. 2351-2357
    • Gough, D.A.1    Lucisano, J.Y.2    Tze, P.H.S.3
  • 16
    • 17344368264 scopus 로고    scopus 로고
    • Oxygen-rich oxidase enzyme electrodes for operation in oxygen-free solutions
    • DOI 10.1021/ja972759p
    • J. Wang, and F. Lu Oxygen-rich oxidase enzyme electrodes for operation in oxygen-free solutions J. Am. Chem. Soc. 120 1998 1048 1050 (Pubitemid 28089902)
    • (1998) Journal of the American Chemical Society , vol.120 , Issue.5 , pp. 1048-1050
    • Kashyap, S.1    Lu, F.2
  • 17
    • 0002456370 scopus 로고
    • Voltammetric and amperometric determination of ascorbic acid at a chemically modified carbon fiber microelectrode
    • Z.Q. Gao, A. Ivaska, T.X. Zha, G.Q. Wang, P.B. Li, and Z.F. Zhao Voltammetric and amperometric determination of ascorbic acid at a chemically modified carbon fiber microelectrode Talanta 40 1993 399 403
    • (1993) Talanta , vol.40 , pp. 399-403
    • Gao, Z.Q.1    Ivaska, A.2    Zha, T.X.3    Wang, G.Q.4    Li, P.B.5    Zhao, Z.F.6
  • 18
    • 0001514651 scopus 로고
    • Electrocatalysis of ascorbic acid at PPy/DS Film coated electrodes
    • Z.Q. Gao, B.S. Chen, and M.X. Zi Electrocatalysis of ascorbic acid at PPy/DS Film coated electrodes J. Electroanal. Chem. 365 1994 197 205
    • (1994) J. Electroanal. Chem. , vol.365 , pp. 197-205
    • Gao, Z.Q.1    Chen, B.S.2    Zi, M.X.3
  • 19
    • 11944262355 scopus 로고
    • Electrical wiring of redox enzymes
    • A. Heller Electrical wiring of redox enzymes Acc. Chem. Res. 23 1990 128 134
    • (1990) Acc. Chem. Res. , vol.23 , pp. 128-134
    • Heller, A.1
  • 20
    • 0024274320 scopus 로고    scopus 로고
    • Covalent enzyme coupling on cellulose acetate membranes for glucose sensor development
    • R. Sternberg, D.S. Bindra, G.S. Wilson, and D.R. Thevenot Covalent enzyme coupling on cellulose acetate membranes for glucose sensor development Anal. Chem. 60 1998 2781 2786
    • (1998) Anal. Chem. , vol.60 , pp. 2781-2786
    • Sternberg, R.1    Bindra, D.S.2    Wilson, G.S.3    Thevenot, D.R.4
  • 21
    • 0000707017 scopus 로고
    • Electropolymerized 1,2-diaminobenzene as a means to prevent interferences and fouling and to stabilize immobilized enzyme in electrochemical biosensors
    • S.V. Sasso, R.J. Pierce, R. Walla, and A.M. Yacynych Electropolymerized 1,2-diaminobenzene as a means to prevent interferences and fouling and to stabilize immobilized enzyme in electrochemical biosensors Anal. Chem. 62 1990 1111 1117
    • (1990) Anal. Chem. , vol.62 , pp. 1111-1117
    • Sasso, S.V.1    Pierce, R.J.2    Walla, R.3    Yacynych, A.M.4
  • 22
    • 0027757187 scopus 로고
    • An interference-free biosensor based on glucose oxidase electrochemically immobilized in a non-conducting poly(pyrrole) film for continuous subcutaneous monitoring of glucose through microdialysis sampling
    • DOI 10.1016/0956-5663(93)80023-I
    • F. Palmisano, D. Centonze, A. Guerrieri, and P.G. Zambonin An interference-free biosensor based on glucose oxidase electrochemically immobilized in a nonconducting poly(pyrrole) film for continuous subcutaneous monitoring of glucose through microdialysis sampling Biosens. Bioelectron. 8 1993 393 399 (Pubitemid 24038724)
    • (1993) Biosensors and Bioelectronics , vol.8 , Issue.9-10 , pp. 393-399
    • Palmisano, F.1    Centonze, D.2    Guerrieri, A.3    Zambonin, P.G.4
  • 23
    • 0027515401 scopus 로고
    • Permselective lipid-poly(o-phenylenediamine) coatings for amperometric biosensing of glucose
    • DOI 10.1016/0003-2670(93)85282-O
    • J. Wang, and H. Wu Permselective lipid-poly(o-phenylenediamine) coatings for amperometric biosensing of glucose Anal. Chim. Acta 283 1993 683 688 (Pubitemid 23345808)
    • (1993) Analytica Chimica Acta , vol.283 , Issue.2 , pp. 683-688
    • Wang, J.1    Wu, H.2
  • 24
    • 0028533426 scopus 로고
    • In vitro and in vivo performance and lifetime of perfluorinated ionomer-coated glucose sensors after high-temperature curing
    • F. Moussy, S. Jakeway, D.J. Harrison, and R.V. Rajotte In vitro and in vivo performance and lifetime of perfluorinated ionomer-coated glucose sensors after high-temperature curing Anal. Chem. 66 1994 3882 3888
    • (1994) Anal. Chem. , vol.66 , pp. 3882-3888
    • Moussy, F.1    Jakeway, S.2    Harrison, D.J.3    Rajotte, R.V.4
  • 25
    • 84987566723 scopus 로고
    • Use of polymer films in amperometric biosensors
    • S.A. Emr, and A.M. Yacynych Use of polymer films in amperometric biosensors Electroanalysis 7 1995 913 923
    • (1995) Electroanalysis , vol.7 , pp. 913-923
    • Emr, S.A.1    Yacynych, A.M.2
  • 26
  • 27
    • 0034663104 scopus 로고    scopus 로고
    • In situ assembled mass-transport controlling micromembranes and their application in implanted amperometric glucose sensors
    • DOI 10.1021/ac000348c
    • T. Chen, K.A. Friedman, I. Lei, and A. Heller In situ assembled mass-transport controlling micromembranes and their application in implanted amperometric glucose sensors Anal. Chem. 72 2000 3757 3763 (Pubitemid 30646512)
    • (2000) Analytical Chemistry , vol.72 , Issue.16 , pp. 3757-3763
    • Chen, T.1    Friedman, K.A.2    Lei, I.3    Heller, A.4
  • 30
    • 84880946525 scopus 로고    scopus 로고
    • Glucose biosensor based on an anionic redox polymer-mediated enzymatic oxidation of glucose
    • H.M. Deng, W. Shen, and Z.Q. Gao Glucose biosensor based on an anionic redox polymer-mediated enzymatic oxidation of glucose ChemPhysChem 14 2013 2343 2347
    • (2013) ChemPhysChem , vol.14 , pp. 2343-2347
    • Deng, H.M.1    Shen, W.2    Gao, Z.Q.3
  • 31
    • 0025042618 scopus 로고
    • Electron-transfer communication between a redox polymer matrix and an immobilized enzyme: Activity of nitrate reductase in a viologen-acrylamide copolymer
    • DOI 10.1021/ja00173a065
    • I. Willner, N.J. Lapidot, and A. Riklin Electron transfer communication between a redox polymer matrix and immobilized enzyme activity of nitrate reductase in a viologen-acrylamide copolymer J. Am. Chem. Soc. 112 1990 6438 6439 (Pubitemid 20271857)
    • (1990) Journal of the American Chemical Society , vol.112 , Issue.17 , pp. 6438-6439
    • Willner, I.1    Riklin, A.2    Lapidot, N.3
  • 33
    • 10444278102 scopus 로고    scopus 로고
    • On the parameters affecting the characteristics of the "wired" glucose oxidase anode
    • N. Mano, F. Mao, and A. Heller On the parameters affecting the characteristics of the "wired" glucose oxidase anode J. Electroanal. Chem. 574 2005 347 357
    • (2005) J. Electroanal. Chem. , vol.574 , pp. 347-357
    • Mano, N.1    Mao, F.2    Heller, A.3
  • 35
    • 84865754591 scopus 로고    scopus 로고
    • Biomimetic sensor for certain catecholamines employing copper(II)complex and silver nanoparticle modified glassy carbon paste electrode
    • B.J. Sanghavi, S.M. Mobin, P. Mathur, G.K. Lahiri, and A.K. Srivastava Biomimetic sensor for certain catecholamines employing copper(II)complex and silver nanoparticle modified glassy carbon paste electrode Biosens. Bioelectron. 39 2012 124 132
    • (2012) Biosens. Bioelectron. , vol.39 , pp. 124-132
    • Sanghavi, B.J.1    Mobin, S.M.2    Mathur, P.3    Lahiri, G.K.4    Srivastava, A.K.5
  • 36
    • 0000475128 scopus 로고
    • Purification and properties of glucose oxidase from Aspergillus niger
    • B.E.P. Swoboda, and V. Massory Purification and properties of glucose oxidase from Aspergillus niger J. Biol. Chem. 240 1965 2209 2215
    • (1965) J. Biol. Chem. , vol.240 , pp. 2209-2215
    • Swoboda, B.E.P.1    Massory, V.2
  • 37
    • 0026590041 scopus 로고
    • Evaluating in vitro and in vivo the interference of ascorbate and acetaminophen on glucose detection by a needle-type glucose sensor
    • D. Moatti-Sirat, G. Velho, and G. Reach Evaluating in vitro and in vivo the interference of ascorbate and acetaminophen on glucose detection by a needle-type glucose sensor Biosens. Bioelectron. 7 1992 345 352
    • (1992) Biosens. Bioelectron. , vol.7 , pp. 345-352
    • Moatti-Sirat, D.1    Velho, G.2    Reach, G.3
  • 38
    • 0020117796 scopus 로고
    • Electrochemical interferences with the YSI glucose analyzer
    • M. Lindh, K. Lindgren, A. Carlström, and P. Masson Electrochemical interferences with the YSI glucose analyzer Clin. Chem. 28 1982 726
    • (1982) Clin. Chem. , vol.28 , pp. 726
    • Lindh, M.1    Lindgren, K.2    Carlström, A.3    Masson, P.4
  • 39
    • 0017094429 scopus 로고
    • Interference by acetaminophen in the glucose oxidase-peroxidase method for blood glucose determination
    • I. Kaufmann-Raab, H.G. Jonen, E. Jähnchen, G.F. Kahl, and U. Groth Interference by acetaminophen in the glucose oxidase-peroxidase method for blood glucose determination Clin. Chem. 22 1976 1729 1731
    • (1976) Clin. Chem. , vol.22 , pp. 1729-1731
    • Kaufmann-Raab, I.1    Jonen, H.G.2    Jähnchen, E.3    Kahl, G.F.4    Groth, U.5
  • 41
    • 19744375756 scopus 로고    scopus 로고
    • Evaluation of an amperometric glucose biosensor based on a ruthenium complex mediator of low redox potential
    • DOI 10.1016/j.talanta.2005.01.036, PII S0039914005000457
    • K. Yamamoto, H.S. Zeng, Y. Shen, M.M. Ahmed, and T. Kato Evaluation of an amperometric glucose biosensor based on a ruthenium complex mediator of low redox potential Talanta 66 2005 1175 1180 (Pubitemid 40743602)
    • (2005) Talanta , vol.66 , Issue.5 , pp. 1175-1180
    • Yamamoto, K.1    Zeng, H.2    Shen, Y.3    Ahmed, M.M.4    Kato, T.5
  • 42
    • 0036037350 scopus 로고    scopus 로고
    • Charge mediation by ruthenium poly(pyridine) complexes in 'second-generation' glucose biosensors based on carboxymethylated β-cyclodextrin polymer membranes
    • DOI 10.1007/s00216-002-1308-9
    • E. Kosela, H. Elzanowska, and W. Kutner Charge mediation by ruthenium poly (pyridine) complexes in 'second-generation' glucose biosensors based on carboxymethylated β-cyclodextrin polymer membranes Anal. Bioanal. Chem. 373 2002 724 734 (Pubitemid 34994806)
    • (2002) Analytical and Bioanalytical Chemistry , vol.373 , Issue.8 , pp. 724-734
    • Kosela, E.1    Elzanowska, H.2    Kutner, W.3
  • 43
    • 33746613770 scopus 로고    scopus 로고
    • Amperometric glucose biosensor based on entrapment of glucose oxidase in a poly(3,4-ethylenedioxythiophene) film
    • P.-C. Nien, T.S. Tung, and K.-C. Ho Amperometric glucose biosensor based on entrapment of glucose oxidase in a poly(3,4-ethylenedioxythiophene) film Electroanalysis 18 2006 1408 1415
    • (2006) Electroanalysis , vol.18 , pp. 1408-1415
    • Nien, P.-C.1    Tung, T.S.2    Ho, K.-C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.