-
1
-
-
0000710658
-
Control of structure of carbon for use in Bioengineering
-
P.L. Walker
-
J.C. Bokros, L.D. LaGrange, and F.J. Schoen Control of structure of carbon for use in Bioengineering P.L. Walker, Chem. Phys. Carbon 9 1972 103 156
-
(1972)
Chem. Phys. Carbon
, vol.9
, pp. 103-156
-
-
Bokros, J.C.1
Lagrange, L.D.2
Schoen, F.J.3
-
2
-
-
0017675704
-
Carbon biomedical devices
-
J.C. Bokros Carbon biomedical devices Carbon 15 1977 355 371
-
(1977)
Carbon
, vol.15
, pp. 355-371
-
-
Bokros, J.C.1
-
3
-
-
0542376603
-
-
Elsevier Science Publisher Amsterdam
-
P. Arru, M. Santi, F. Vallana, G. Majni, and G. Ottaviani A New Pyrolytic Film for Biomedical Applications, High Tech Ceramics 1987 Elsevier Science Publisher Amsterdam 117 126
-
(1987)
A New Pyrolytic Film for Biomedical Applications, High Tech Ceramics
, pp. 117-126
-
-
Arru, P.1
Santi, M.2
Vallana, F.3
Majni, G.4
Ottaviani, G.5
-
4
-
-
0027153024
-
Carbofilm; Present and future applications in biological devices
-
F. Vallana, E. Pasquino, S. Rinaldi, M. Galloni, A.M. Gatti, F. Modica, and A. Benech Carbofilm; present and future applications in biological devices Ceram. Int. 19 1993 169 178
-
(1993)
Ceram. Int.
, vol.19
, pp. 169-178
-
-
Vallana, F.1
Pasquino, E.2
Rinaldi, S.3
Galloni, M.4
Gatti, A.M.5
Modica, F.6
Benech, A.7
-
5
-
-
0031543388
-
Development of self-anchoring bone implants. Processing and material characterization
-
A. Abusafieh, S. Siegler, and S.R. Kalidindi Development of self-anchoring bone implants. Processing and material characterization J. Biomed. Mater. Res. 38 Winter 1997 314 321
-
(1997)
J. Biomed. Mater. Res.
, vol.38
, pp. 314-321
-
-
Abusafieh, A.1
Siegler, S.2
Kalidindi, S.R.3
-
6
-
-
0000695438
-
Protein adsorption on low-temperature isotropic carbon
-
L. Feng, and J.D. Andrade Protein adsorption on low-temperature isotropic carbon J. Colloid Interface Sci. 166 1994 419 426
-
(1994)
J. Colloid Interface Sci.
, vol.166
, pp. 419-426
-
-
Feng, L.1
Andrade, J.D.2
-
7
-
-
0034086018
-
Carbon fiber post adhesion to resin luting cement in the restoration of endodontically treated teeth
-
R. De Santis, D. Prisco, A. Apicella, L. Ambrosio, S. Rengo, and L. Nicolas Carbon fiber post adhesion to resin luting cement in the restoration of endodontically treated teeth J. Mater. Sci. Mater. Med. 11 2000 201 211
-
(2000)
J. Mater. Sci. Mater. Med.
, vol.11
, pp. 201-211
-
-
De Santis, R.1
Prisco, D.2
Apicella, A.3
Ambrosio, L.4
Rengo, S.5
Nicolas, L.6
-
8
-
-
0033008636
-
Long-term follow-up of pyrolytic carbon metacarpophalangeal implants
-
S.D. Cook, R.D. Beckenbangh, L.S. Popich, J.J. Klawitter, and R.L. Linscheid Long-term follow-up of pyrolytic carbon metacarpophalanged implants J. Bone Joint Surg. Am. 81 1999 635 648 (Pubitemid 29241149)
-
(1999)
Journal of Bone and Joint Surgery - Series A
, vol.81
, Issue.5
, pp. 635-648
-
-
Cook, S.D.1
Beckenbaugh, R.D.2
Redondo, J.3
Popich, L.S.4
Klawitter, J.J.5
Linscheid, R.L.6
-
9
-
-
0033716465
-
Haemocompatibility of tetrahedral amorphous carbon films
-
L.J. Yu, X. Wang, X.H. Wang, and X.H. Liu Haemocompatibility of tetrahedral amorphous carbon films Surf. Coat. Technol. 128-129 2000 484 488
-
(2000)
Surf. Coat. Technol.
, vol.128-129
, pp. 484-488
-
-
Yu, L.J.1
Wang, X.2
Wang, X.H.3
Liu, X.H.4
-
10
-
-
0034666723
-
In vitro analyses of diamond-like carbon coated stents: Reduction of metal ion release, platelet activation, and thrombogenicity
-
DOI 10.1016/S0049-3848(00)00295-4, PII S0049384800002954
-
K. Gutensohn, C. Beythien, J. Bau, T. Fenner, P. Greve, R. Koester, K. Padmannaban, and P. Kuehnl In vitro analyses of diamond-like carbon coated stents: reduction of metal ion release, platelet activation and thrombogenicity Trombosis Research 99 2000 577 585 (Pubitemid 30642739)
-
(2000)
Thrombosis Research
, vol.99
, Issue.6
, pp. 577-585
-
-
Gutensohn, K.1
Beythien, C.2
Bau, J.3
Fenner, T.4
Grewe, P.5
Koester, R.6
Padmanaban, K.7
Kuehnl, P.8
-
11
-
-
0036508227
-
Wettability and surface energy of oxidized and hydrogen plasma-treated diamond films
-
DOI 10.1016/S0925-9635(01)00636-7, PII S0925963501006367, Proceedings of Diamond 2001, the 12th Conference on Diamond, Diamond-like materials, Carbon Nanotubes, Nitrides and Silicon Carbide
-
L. Ostrovska, V. Perevertailo, V. Ralchenko, A. Dementjev, and O. Loginova Wettability and surface energy of oxidized and hydrogen plasma-treated diamond films Diamond Relat. Mater. 11 2002 845 850 (Pubitemid 34696363)
-
(2002)
Diamond and Related Materials
, vol.11
, Issue.3-6
, pp. 845-850
-
-
Ostrovskaya, L.1
Perevertailo, V.2
Ralchenko, V.3
Dementjev, A.4
Loginova, O.5
-
12
-
-
0026816817
-
Properties of diamond-like carbon
-
J. Robertson Properties of diamond-like carbon Surf. Coat. Technol. 50 1992 185 203
-
(1992)
Surf. Coat. Technol.
, vol.50
, pp. 185-203
-
-
Robertson, J.1
-
13
-
-
84887445215
-
Optimization of haemocompatibility and functionality of cardiovascular implants by a hybrid design, biomaterial-tissue interface
-
Elsevier Science Publisher
-
A. Boltz Optimization of haemocompatibility and functionality of cardiovascular implants by a hybrid design, biomaterial-tissue interface Advances in Biomaterials 1992 Elsevier Science Publisher
-
(1992)
Advances in Biomaterials
-
-
Boltz, A.1
-
14
-
-
6444221603
-
Comparative aspects of blood coagulation
-
DOI 10.1016/j.tvjl.2003.09.013, PII S1090023303001771
-
P.A. Gentry Comparative aspects of blood coagulation Vet. J. 168 2004 238 251 (Pubitemid 39406746)
-
(2004)
Veterinary Journal
, vol.168
, Issue.3
, pp. 238-251
-
-
Gentry, P.A.1
-
15
-
-
84887420701
-
Carbon coatings for cardiosurgery - Preliminary results
-
R. Mania, D. Oblakowska, and S. Blazewicz Carbon coatings for cardiosurgery - preliminary results Eng. Biomat. 17-19 2001 42 44
-
(2001)
Eng. Biomat.
, vol.17-19
, pp. 42-44
-
-
Mania, R.1
Oblakowska, D.2
Blazewicz, S.3
-
16
-
-
0036010387
-
2 thin films
-
DOI 10.1016/S0142-9612(01)00389-1, PII S0142961201003891
-
2 thin films Biomaterials 23 2002 2545 2552 (Pubitemid 34288494)
-
(2002)
Biomaterials
, vol.23
, Issue.12
, pp. 2545-2552
-
-
Chen, J.Y.1
Leng, Y.X.2
Tian, X.B.3
Wang, L.P.4
Huang, N.5
Chu, P.K.6
Yang, P.7
-
17
-
-
0036668469
-
In vitro hemocompatibility testing of biomaterials according to the ISO 10993-4
-
U.T. Seyfert, V. Biehl, and J. Schenk In vitro hemocompatibility testing of biomaterials according to the ISO 10993-4 Biomol. Eng. 19 2002 91 96
-
(2002)
Biomol. Eng.
, vol.19
, pp. 91-96
-
-
Seyfert, U.T.1
Biehl, V.2
Schenk, J.3
-
21
-
-
34547981203
-
Study on influence of gelatin-alginate matrixes on the coagulation system and morphotic blood elements
-
DOI 10.1002/masy.200750709
-
M. Szymonowicz, S. Pielka, A. Owczarek, D. Haznar, and J. Pluta Study on influence of gelatin-alginate matrixes on the coagulation system and morphotic blood elements Macromol. Symp. 253 2007 71 76 (Pubitemid 47271778)
-
(2007)
Macromolecular Symposia
, vol.253
, pp. 71-76
-
-
Szymonowicz, M.1
Pielka, S.2
Owczarek, A.3
Haznar, D.4
Pluta, J.5
-
22
-
-
34447321590
-
Modified polycarbonate urethane: Synthesis, properties and biological investigation in vitro
-
DOI 10.1002/jbm.a.31357
-
A. Szelest -Lewandowska, M. Masiulanis, M. Szymonowicz, S. Pielka, and D. Paluch Modified poly(carbonate urethane). Synthesis, properties and biological investigation in vitro J. Biomed. Mater. Res. A 82 2007 509 520 (Pubitemid 47051683)
-
(2007)
Journal of Biomedical Materials Research - Part A
, vol.82
, Issue.2
, pp. 509-520
-
-
Szelest-Lewandowska, A.1
Masiulanis, B.2
Szymonowicz, M.3
Pielka, S.4
Paluch, D.5
-
23
-
-
1942509531
-
Hereditary Spherocytosis - Defects in Proteins That Connect the Membrane Skeleton to the Lipid Bilayer
-
DOI 10.1053/j.seminhematol.2004.01.002
-
S. Eber, and S.E. Lux Hereditary spherocytosis - defects in proteins that connect the membrane skeleton to the lipid bilayer Semin. Hematol. 41 2004 118 141 (Pubitemid 38509638)
-
(2004)
Seminars in Hematology
, vol.41
, Issue.2
, pp. 118-141
-
-
Eber, S.1
Lux, S.E.2
-
24
-
-
0014772420
-
Abnormal kinetics of red cell membrane cholesterol in acanthocytes: Studies in genetic and experimental abetalipoproteinaemia and in spur cell anaemia
-
J.A. McBride, and H.S. Jacob Abnormal kinetics of red cell membrane cholesterol in acanthocytes: studies in genetic and experimental abetalipoproteinaemia and in spur cell anaemia Br. J. Haematol. 18 1970 383 398
-
(1970)
Br. J. Haematol.
, vol.18
, pp. 383-398
-
-
McBride, J.A.1
Jacob, H.S.2
-
25
-
-
0034333612
-
Protein adsorption and platelet attachment and activation, on TiN, TiC, and DLC coatings on titanium for cardiovascular applications
-
DOI 10.1002/1097-4636(200011) 52:2<413::AID-JBM23>3.0.CO;2-U
-
M.I. Jones, I.R. McColl, D.M. Grant, K.G. Paker, and T.I. Paker Protein adsorption and platelet attachment and activation on TiN, TiC, and DLC coatings on titanium for cardiovascular applications J. Biomed. Mater. Res. 52 2000 413 421 (Pubitemid 30646814)
-
(2000)
Journal of Biomedical Materials Research
, vol.52
, Issue.2
, pp. 413-421
-
-
Jones, M.I.1
McColl, I.R.2
Grant, D.M.3
Parker, K.G.4
Parker, T.L.5
-
26
-
-
84947144160
-
Measurement of fibrinogen adsorption from blood plasma using 125I-fibrinogen and a direct ELISA technique
-
S.M. Slack, S.E. Posso, and T.A. Horbett Measurement of fibrinogen adsorption from blood plasma using 125I-fibrinogen and a direct ELISA technique J. Biomater. Sci. Polym. 3 1991 49 67
-
(1991)
J. Biomater. Sci. Polym.
, vol.3
, pp. 49-67
-
-
Slack, S.M.1
Posso, S.E.2
Horbett, T.A.3
-
27
-
-
42749096667
-
On the mechanisms of biocompatibility
-
D.F. Williams On the mechanisms of biocompatibility Biomaterials 29 2008 2941 2953
-
(2008)
Biomaterials
, vol.29
, pp. 2941-2953
-
-
Williams, D.F.1
-
28
-
-
0141534374
-
On the influence of flow conditions and wettability on blood material interactions
-
DOI 10.1016/S0142-9612(03)00380-6
-
H.T. Spijker, R. Graaff, P.W. Boonstra, H.J. Busscher, and W. van Oeveren On the influence of flow conditions and wettability on blood material interactions Biomaterials 24 2003 4717 4727 (Pubitemid 37188653)
-
(2003)
Biomaterials
, vol.24
, Issue.26
, pp. 4717-4727
-
-
Spijker, H.T.1
Graaff, R.2
Boonstra, P.W.3
Busscher, H.J.4
Van Oeveren, W.5
-
29
-
-
0030789092
-
Hemolytic effect of surface roughness of an impeller in a centrifugal blood pump
-
Y. Takami, T. Nakazawa, T.K. Makinouchi, E. Tayama, J. Glueck, R. Benkowski, and Y. Nose Hemolytic effect of surface roughness of an impeller in a centrifugal blood pump Artif. Organs 21 1997 686 690 (Pubitemid 27314408)
-
(1997)
Artificial Organs
, vol.21
, Issue.7
, pp. 686-690
-
-
Takami, Y.1
Nakazawa, T.2
Makinouchi, K.3
Tayama, E.4
Glueck, J.5
Benkowski, R.6
Nose, Y.7
|