메뉴 건너뛰기




Volumn , Issue , 2006, Pages 249-268

The challenge of human skin-Engineering the biotic/abiotic interface

Author keywords

[No Author keywords available]

Indexed keywords


EID: 84887467449     PISSN: None     EISSN: None     Source Type: Book    
DOI: None     Document Type: Chapter
Times cited : (1)

References (30)
  • 1
    • 4944261235 scopus 로고    scopus 로고
    • 1993-2004 Microsoft Corporation. All rights reserved
    • Structure of the Skin, Microsoft® Encarta® Encyclopedia. http://encarta.msn.com© 1993-2004 Microsoft Corporation. All rights reserved.
    • Microsoft® Encarta® Encyclopedia
  • 2
    • 0029813337 scopus 로고    scopus 로고
    • Stratum corneum architecture, metabolic activity and interactivity with subjacent cell layers
    • Elias, P., Stratum corneum architecture, metabolic activity and interactivity with subjacent cell layers. Exp. Dermatol, 1996, 5: 191-201.
    • (1996) Exp. Dermatol , vol.5 , pp. 191-201
    • Elias, P.1
  • 3
    • 0029826349 scopus 로고    scopus 로고
    • The stratum corneum revisited
    • Elias, P., The stratum corneum revisited. J. Dermatol., 1996, 23: 756-758.
    • (1996) J. Dermatol , vol.23 , pp. 756-758
    • Elias, P.1
  • 4
    • 0025293468 scopus 로고
    • Sensory transduction and the mammalian epidermis
    • Hoath, S. B., Donnelly, M. M., and Boissy, R. E., Sensory transduction and the mammalian epidermis. Biosens. Bioelectron., 1990, 5(5): 351-366.
    • (1990) Biosens. Bioelectron , vol.5 , Issue.5 , pp. 351-366
    • Hoath, S.B.1    Donnelly, M.M.2    Boissy, R.E.3
  • 5
    • 0001123844 scopus 로고
    • The principles and potential of electrical admittance spectroscopy: An introduction
    • Turner, A. P. F., Karube, I., and Wilson, G. S., (eds.) Oxford University Press
    • Kell, D. B., The principles and potential of electrical admittance spectroscopy: An introduction. In: Biosensors; Fundamentals and Applications. Turner, A. P. F., Karube, I., and Wilson, G. S., (eds.) Oxford University Press, 1987: pp. 427-468.
    • (1987) Biosensors; Fundamentals and Applications , pp. 427-468
    • Kell, D.B.1
  • 6
    • 0030020827 scopus 로고    scopus 로고
    • Correlation of impedance response patterns to histological findings in irritant skin reactions induced by various surfactants
    • Nicander, I., Ollmar, S., Eek, A., Lundh, R. B., and Emtestam, L., Correlation of impedance response patterns to histological findings in irritant skin reactions induced by various surfactants. Br. J. Dermatol., 1996, 134: 221-228.
    • (1996) Br. J. Dermatol , vol.134 , pp. 221-228
    • Nicander, I.1    Ollmar, S.2    Eek, A.3    Lundh, R.B.4    Emtestam, L.5
  • 7
    • 0028139381 scopus 로고
    • Stratum corneum moisturization at the molecular level. J
    • Rawlings, A. et al., Stratum corneum moisturization at the molecular level. J. Invest. Dermatol., 1994, 103: 731-741.
    • (1994) Invest. Dermatol , vol.103 , pp. 731-741
    • Rawlings, A.1
  • 8
    • 25144518880 scopus 로고    scopus 로고
    • Everything's great when it sits on a chip-A bright future for DNA arrays
    • Sinclair, B., Everything's great when it sits on a chip-A bright future for DNA arrays. Scientist, 1998, 13: 18-20.
    • (1998) Scientist , vol.13 , pp. 18-20
    • Sinclair, B.1
  • 9
    • 85129960102 scopus 로고    scopus 로고
    • (Accessed May 15)
    • Swanson, J. R., http://www.meddean.luc.edu/lumen/MedEd/medicine/dermatology/ melton/skinlsn/epider.htm (Accessed May 15, 2005).
    • (2005)
    • Swanson, J.R.1
  • 11
    • 0001065001 scopus 로고    scopus 로고
    • Making electronic biopsies into a viable future for non-invasive diagnostics with electrical impedance. Med
    • Ollmar, S., Making electronic biopsies into a viable future for non-invasive diagnostics with electrical impedance. Med. Biol. Eng. Comput., 1999, 7(2): 116-117.
    • (1999) Biol. Eng. Comput , vol.7 , Issue.2 , pp. 116-117
    • Ollmar, S.1
  • 14
    • 0030134268 scopus 로고    scopus 로고
    • Microsensors based on conducting polymers
    • Imisides, M. D., John, R., and Wallace, G. G., Microsensors based on conducting polymers. Chemtech, 1996, 26(5): 19-25.
    • (1996) Chemtech , vol.26 , Issue.5 , pp. 19-25
    • Imisides, M.D.1    John, R.2    Wallace, G.G.3
  • 15
    • 0035279245 scopus 로고    scopus 로고
    • MicroMachined electrodes for biopotential measurements
    • Griss, P. et al., MicroMachined electrodes for biopotential measurements. JMEMS, 2001, 10: 10-16.
    • (2001) JMEMS , vol.10 , pp. 10-16
    • Griss, P.1
  • 16
    • 21344456404 scopus 로고    scopus 로고
    • Micro blood flow measurement using thermal conductivity micro needles: A new CMOS compatible manufacturing process onto porous silicon
    • Perchon, S. et al., Micro blood flow measurement using thermal conductivity micro needles: A new CMOS compatible manufacturing process onto porous silicon. IEEE, 2000: 184-187.
    • (2000) IEEE , pp. 184-187
    • Perchon, S.1
  • 17
    • 3142701503 scopus 로고    scopus 로고
    • Transdermal patches are more than skin deep
    • April
    • Morrow, T., Transdermal patches are more than skin deep. Managed Care, April 2004.
    • (2004) Managed Care
    • Morrow, T.1
  • 20
    • 0033314690 scopus 로고    scopus 로고
    • Micro needles for transdermal delivery of molecules
    • McAllister, D. V. et al., Micro needles for transdermal delivery of molecules. IEEE, 1999: 836.
    • (1999) IEEE , pp. 836
    • McAllister, D.V.1
  • 21
    • 0036199710 scopus 로고    scopus 로고
    • Silicon micro machined hollow micro needles for transdermal liquid transfer
    • Gardeniers, J. G. E. et al., Silicon micro machined hollow micro needles for transdermal liquid transfer. IEEE, 2002: 141-144.
    • (2002) IEEE , pp. 141-144
    • Gardeniers, J.G.E.1
  • 23
    • 0031699257 scopus 로고    scopus 로고
    • Micromachined needles for the transdermal delivery of drugs
    • Henry, S. et al., Micromachined needles for the transdermal delivery of drugs. IEEE, 1998: 494-498.
    • (1998) IEEE , pp. 494-498
    • Henry, S.1
  • 28
    • 0041328465 scopus 로고    scopus 로고
    • Fabrication of microcapacitors using conducting polymer microelectrodes
    • Sung, J.-H., Kim, S.-J., and Lee, K.-H., Fabrication of microcapacitors using conducting polymer microelectrodes. J. Power Sources, 2003, 124(1): 343-350.
    • (2003) J. Power Sources , vol.124 , Issue.1 , pp. 343-350
    • Sung, J.-H.1    Kim, S.-J.2    Lee, K.-H.3
  • 30
    • 0037112471 scopus 로고    scopus 로고
    • Optimization of the geometry and porosity of microelectrode arrays for sensor design
    • Sandison, M. E. et al., Optimization of the geometry and porosity of microelectrode arrays for sensor design. Anal. Chem., 2002, 74: 5717-5725.
    • (2002) Anal. Chem , vol.74 , pp. 5717-5725
    • Sandison, M.E.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.