Volumn 7, Issue PARTS A, B, C, D, 2012, Pages 1823-1832

Two-phase refrigerant maldistribution in the vertical header and its effect on the heat exchanger performance as evaporator in heat pump mode

Author keywords

[No Author keywords available]

Indexed keywords

AIR CONDITIONING; EVAPORATORS; FLOW RATE; HEAT PUMP SYSTEMS; HEAT TRANSFER; MICROCHANNELS; TUBES (COMPONENTS);

EID: 84887273452     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1115/IMECE2012-89578     Document Type: Conference Paper
Times cited : (11)

References (18)
  • 1
    • 0348157266 scopus 로고    scopus 로고
    • Header design tradeoffs in microchannel evaporators
    • Kulkarni, T., Bullard, C.W., Cho, K., 2004. "Header design tradeoffs in microchannel evaporators". Appl. Thermal Eng., 24, 759-776.
    • (2004) Appl. Thermal Eng , vol.24 , pp. 759-776
    • Kulkarni, T.1    Bullard, C.W.2    Cho, K.3
  • 3
    • 7044241466 scopus 로고    scopus 로고
    • Flash gas bypass for improving the performance of transcritical r744 systems that use microchannel evaporators
    • Elbel, S., Hrnjak, P.S., 2004. "Flash gas bypass for improving the performance of transcritical R744 systems that use microchannel evaporators". Int. J. Refrigeration, 27, 724-735.
    • (2004) Int. J. Refrigeration , vol.27 , pp. 724-735
    • Elbel, S.1    Hrnjak, P.S.2
  • 4
    • 84866393183 scopus 로고    scopus 로고
    • Flash gas bypass in mobile air conditioning system with r134a
    • 2012.05.013,Doi:10.1016/j.ijrefrig
    • Tuo, H., Hrnjak, P.S., 2012. "Flash gas bypass in mobile air conditioning system with R134a". Int. J. Refrigeration, doi:10.1016/j.ijrefrig.2012.05.013.
    • (2012) Int. J. Refrigeration
    • Tuo, H.1    Hrnjak, P.S.2
  • 5
    • 84863216368 scopus 로고    scopus 로고
    • Experimentally validated model of refrigerant distribution in a parallel microchannel evaporator
    • Tuo, H., Bielskus, A., Hrnjak, P.S., 2012. "Experimentally validated model of refrigerant distribution in a parallel microchannel evaporator". SAE Int. J. Materials and Manufacturing, 5(2), 365-374.
    • (2012) SAE Int. J. Materials and Manufacturing , vol.5 , Issue.2 , pp. 365-374
    • Tuo, H.1    Bielskus, A.2    Hrnjak, P.S.3
  • 6
    • 2442500638 scopus 로고    scopus 로고
    • Flow distribution issues in parallel flow heat exchangers
    • AN-04-1-2
    • Hrnjak, P., 2004. "Flow distribution issues in parallel flow heat exchangers". ASHRAE Annu. Meet., AN-04-1-2.
    • (2004) ASHRAE Annu. Meet
    • Hrnjak, P.1
  • 7
    • 17444415034 scopus 로고    scopus 로고
    • Two-phase flow distribution to tubes of parallel flow air-cooled heat exchangers
    • Webb, R.L., Chung, K., 2005. "Two-phase flow distribution to tubes of parallel flow air-cooled heat exchangers". Heat Transfer Eng., 26 (4), 3-18.
    • (2005) Heat Transfer Eng , vol.26 , Issue.4 , pp. 3-18
    • Webb, R.L.1    Chung, K.2
  • 8
    • 16544369508 scopus 로고    scopus 로고
    • Adiabatic developing two-phase refrigerant flow in manifolds of heat exchanger
    • s"., Univ. Illinois at Urbana-Champaign
    • Fei, P., Hrnjak, P.S., 2004. "Adiabatic Developing Two-Phase Refrigerant Flow in Manifolds of Heat Exchangers". Technical Report TR-225, Air Conditioning and Refrigeration Center, Univ. Illinois at Urbana-Champaign.
    • (2004) Technical Report TR-225, Air Conditioning and Refrigeration Center
    • Fei, P.1    Hrnjak, P.S.2
  • 9
    • 0348172171 scopus 로고    scopus 로고
    • Two-phase flow distribution in compact heat exchanger manifolds
    • Vist, S., Pettersen, J., 2004. "Two-phase flow distribution in compact heat exchanger manifolds". Exp. Thermal Fluid Sci., 28, 209-215.
    • (2004) Exp. Thermal Fluid Sci , vol.28 , pp. 209-215
    • Vist, S.1    Pettersen, J.2
  • 10
    • 84863221664 scopus 로고    scopus 로고
    • Experimental investigation of two-phase refrigerant distribution in a microchannel manifold
    • Air Conditioning and Refrigeration Center, Univ. Illinois at Urbana-Champaign
    • Bowers, C.D., Newell, T.A., Hrnjak, P.S., 2006. "Experimental Investigation of Two-Phase Refrigerant Distribution in a Microchannel Manifold". Technical Report TR-245, Air Conditioning and Refrigeration Center, Univ. Illinois at Urbana-Champaign.
    • (2006) Technical Report TR-245
    • Bowers, C.D.1    Newell, T.A.2    Hrnjak, P.S.3
  • 11
    • 34347270931 scopus 로고    scopus 로고
    • Refrigerant distribution in minichannel evaporator manifolds
    • Hwang, Y., Jin, D.H., Radermacher, R., 2007. "Refrigerant distribution in minichannel evaporator manifolds". HVAC&R Res., 13 (4), 543-555.
    • (2007) HVAC&R Res , vol.13 , Issue.4 , pp. 543-555
    • Hwang, Y.1    Jin, D.H.2    Radermacher, R.3
  • 12
    • 0029675733 scopus 로고
    • General characteristics of two-phase flow distribution in a multipass tube
    • Watanabe, M., Katsuta, M., Nagata, K., 1995. "General characteristics of two-phase flow distribution in a multipass tube". Heat Transfer-Japanese Res., 24, 32-44.
    • (1995) Heat Transfer-Japanese Res , vol.24 , pp. 32-44
    • Watanabe, M.1    Katsuta, M.2    Nagata, K.3
  • 13
    • 0036459601 scopus 로고    scopus 로고
    • Frost deposition and refrigerant distribution in microchannel heat exchangers
    • Song, S., Bullard, C.W., Hrnjak, P.S., 2002. "Frost deposition and refrigerant distribution in microchannel heat exchangers". ASHRAE Trans., 108 (2), 944-953.
    • (2002) ASHRAE Trans , vol.108 , Issue.2 , pp. 944-953
    • Song, S.1    Bullard, C.W.2    Hrnjak, P.S.3
  • 14
    • 2542460276 scopus 로고    scopus 로고
    • Mass flow rate distribution and phase separation of r-22 in multi-microchannel tubes under adiabatic condition
    • Cho, H., Cho, K., 2004. "Mass flow rate distribution and phase separation of R-22 in multi-microchannel tubes under adiabatic condition". Microscale Thermophysical Eng., 8 (2), 129-139.
    • (2004) Microscale Thermophysical Eng , vol.8 , Issue.2 , pp. 129-139
    • Cho, H.1    Cho, K.2
  • 15
    • 58149293761 scopus 로고    scopus 로고
    • Two-phase flow behavior inside a header connected to multiple parallel channels
    • Lee, J.K., 2009. "Two-phase flow behavior inside a header connected to multiple parallel channels". Exp. Thermal Fluid Sci., 33, 195-202.
    • (2009) Exp. Thermal Fluid Sci , vol.33 , pp. 195-202
    • Lee, J.K.1
  • 16
    • 79957585503 scopus 로고    scopus 로고
    • Refrigerant distribution in a parallel flow heat exchanger having vertical headers and heated horizontal tubes
    • Byun, H.W., Kim, N.H., 2011. "Refrigerant distribution in a parallel flow heat exchanger having vertical headers and heated horizontal tubes". Exp. Thermal Fluid Sci., 35, 920-930. [17].
    • (2011) Exp. Thermal Fluid Sci , vol.35 , Issue.17 , pp. 920-930
    • Byun, H.W.1    Kim, N.H.2
  • 17
  • 18
    • 0003529028 scopus 로고
    • Studies of two-phase flow patterns by simultaneous x-ray and flash photography
    • HMSO
    • Hewitt, G.F., Roberts, D.N., 1969. "Studies of two-phase flow patterns by simultaneous X-ray and flash photography". AERE-M 2159, HMSO.
    • (1969) AERE-M 2159
    • Hewitt, G.F.1    Roberts, D.N.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.