메뉴 건너뛰기




Volumn 35, Issue 7, 2012, Pages 1869-1877

Flash gas bypass in mobile air conditioning system with R134a

Author keywords

Air conditioning system; Microchannel evaporator; Refrigerant distribution; Two phase flow

Indexed keywords

AIRCONDITIONING SYSTEMS; COOLING CAPACITY; DIRECT EXPANSION; FLASH GAS; MOBILE AIR CONDITIONING; REFRIGERANT PRESSURE DROP; SINGLE PASS;

EID: 84866393183     PISSN: 01407007     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ijrefrig.2012.05.013     Document Type: Article
Times cited : (96)

References (18)
  • 1
    • 0038061410 scopus 로고    scopus 로고
    • An Experimental Investigation of Transcritical Carbon dioxide Systems for Residential Air-Conditioning
    • University of Illinois at Urbana-Champaign
    • A.C. Beaver, J. Yin, C.W. Bullard, and P.S. Hrnjak An Experimental Investigation of Transcritical Carbon dioxide Systems for Residential Air-Conditioning ACRC Report CR-18 1999 University of Illinois at Urbana-Champaign
    • (1999) ACRC Report CR-18
    • Beaver, A.C.1    Yin, J.2    Bullard, C.W.3    Hrnjak, P.S.4
  • 2
    • 84863221664 scopus 로고    scopus 로고
    • Experimental Investigation of Two-Phase Refrigerant Distribution in a Microchannel Manifold
    • University of Illinois at Urbana-Champaign
    • C.D. Bowers, T.A. Newell, and P.S. Hrnjak Experimental Investigation of Two-Phase Refrigerant Distribution in a Microchannel Manifold ACRC Report TR-245 2006 University of Illinois at Urbana-Champaign
    • (2006) ACRC Report TR-245
    • Bowers, C.D.1    Newell, T.A.2    Hrnjak, P.S.3
  • 3
    • 2542460276 scopus 로고    scopus 로고
    • Mass flow rate distribution and phase separation of R-22 in multi-microchannel tubes under adiabatic condition
    • H. Cho, and K. Cho Mass flow rate distribution and phase separation of R-22 in multi-microchannel tubes under adiabatic condition Microscale Thermophys. Eng. 8 2 2004 527 533
    • (2004) Microscale Thermophys. Eng. , vol.8 , Issue.2 , pp. 527-533
    • Cho, H.1    Cho, K.2
  • 4
    • 84866392249 scopus 로고    scopus 로고
    • Evaluation of Microchannel Heat Exchangers for A Residential Mini-Split Type Air-Conditioning/Heat Pump System
    • University of Illinois at Urbana-Champaign
    • M. Dshida, and P.S. Hrnjak Evaluation of Microchannel Heat Exchangers for A Residential Mini-Split Type Air-Conditioning/Heat Pump System ACRC Report CP-67 2008 University of Illinois at Urbana-Champaign
    • (2008) ACRC Report CP-67
    • Dshida, M.1    Hrnjak, P.S.2
  • 5
    • 7044241466 scopus 로고    scopus 로고
    • Flash gas bypass for improving the performance of transcritical R744 systems that use microchannel evaporators
    • S.W. Elbel, and P.S. Hrnjak Flash gas bypass for improving the performance of transcritical R744 systems that use microchannel evaporators Int. J. Refrigeration 27 7 2004 724 735
    • (2004) Int. J. Refrigeration , vol.27 , Issue.7 , pp. 724-735
    • Elbel, S.W.1    Hrnjak, P.S.2
  • 6
    • 0035457569 scopus 로고    scopus 로고
    • Detection of liquid mass fraction at the evaporator exit of refrigeration systems
    • DOI 10.1016/S1290-0729(01)01264-9, PII S1290072901012649
    • P.S. Hrnjak, M.A. Shannon, T.M. Leicht, and N.R. Miller Detection of liquid mass fraction at the evaporator exit of refrigeration systems Int. J. Therm. Sci. 40 8 2001 773 786 (Pubitemid 33378341)
    • (2001) International Journal of Thermal Sciences , vol.40 , Issue.8 , pp. 773-786
    • Hrnjak, P.S.1    Shannon, M.A.2    Leicht, T.M.3    Miller, N.R.4
  • 7
    • 34347270931 scopus 로고    scopus 로고
    • Refrigerant distribution in minichannel evaporator manifolds
    • Y. Hwang, D. Jin, and R. Radermacher Refrigerant distribution in minichannel evaporator manifolds HVAC&R Res. 13 4 2007 543 555 (Pubitemid 46993367)
    • (2007) HVAC and R Research , vol.13 , Issue.4 , pp. 543-555
    • Hwang, Y.1    Jin, D.-H.2    Radermacher, R.3
  • 9
    • 0023844053 scopus 로고
    • Describing the uncertainties in experimental results
    • R.J. Moffat Describing the uncertainties in experimental results Exp. Therm. Fluid Sci. 1 1 1988 3 17
    • (1988) Exp. Therm. Fluid Sci. , vol.1 , Issue.1 , pp. 3-17
    • Moffat, R.J.1
  • 10
    • 37549055106 scopus 로고    scopus 로고
    • Experiments on two-phase flow distribution inside parallel channels of compact heat exchangers
    • A. Marchitto, F. Devia, M. Fossa, G. Guglielmini, and C. Schenone Experiments on two-phase flow distribution inside parallel channels of compact heat exchangers Int. J. Multiphase Flow 34 2 2008 128 144
    • (2008) Int. J. Multiphase Flow , vol.34 , Issue.2 , pp. 128-144
    • Marchitto, A.1    Devia, F.2    Fossa, M.3    Guglielmini, G.4    Schenone, C.5
  • 11
    • 79959559061 scopus 로고    scopus 로고
    • Effect of Using Flash Gas Bypass on Evaporator Effectiveness and System Efficiency When Operating with Low Pressure Refrigerants
    • University of Illinois at Urbana-Champaign
    • A. Milosevic, and P.S. Hrnjak Effect of Using Flash Gas Bypass on Evaporator Effectiveness and System Efficiency When Operating with Low Pressure Refrigerants ACRC Report TR-283 2010 University of Illinois at Urbana-Champaign
    • (2010) ACRC Report TR-283
    • Milosevic, A.1    Hrnjak, P.S.2
  • 15
    • 79959539967 scopus 로고    scopus 로고
    • Effect of flash gas bypass on the performance of R134a mobile air-conditioning system with microchannel evaporator
    • H. Tuo, A. Bielskus, and P.S. Hrnjak Effect of flash gas bypass on the performance of R134a mobile air-conditioning system with microchannel evaporator SAE Int. J. Mater. Manufacturing 4 1 2011 231 239
    • (2011) SAE Int. J. Mater. Manufacturing , vol.4 , Issue.1 , pp. 231-239
    • Tuo, H.1    Bielskus, A.2    Hrnjak, P.S.3
  • 16
    • 84865035708 scopus 로고    scopus 로고
    • Experimental Study of Refrigerant Two Phase Separation in Compact Vertical T-junction
    • Paper. CH-12-C086
    • H. Tuo, and P.S. Hrnjak Experimental Study of Refrigerant Two Phase Separation in Compact Vertical T-junction 2012 ASHRAE 2012 Winter Conference, Paper. CH-12-C086
    • (2012) ASHRAE 2012 Winter Conference
    • Tuo, H.1    Hrnjak, P.S.2
  • 17
    • 84863216368 scopus 로고    scopus 로고
    • An Experimentally Validated Model of Refrigerant Distribution in a Parallel Microchannel Evaporator
    • Paper. 2012-01-321
    • H. Tuo, and P.S. Hrnjak An Experimentally Validated Model of Refrigerant Distribution in a Parallel Microchannel Evaporator 2012 SAE 2012 Congress, Paper. 2012-01-321
    • (2012) SAE 2012 Congress
    • Tuo, H.1    Hrnjak, P.S.2
  • 18
    • 84863220406 scopus 로고    scopus 로고
    • Performance Measurement and Visualization on the Refrigerant Distribution in the Vertical Manifold of the Microchannel Tube Heat Exchanger
    • University of Illinois at Urbana-Champaign
    • Y. Zou, and P.S. Hrnjak Performance Measurement and Visualization on the Refrigerant Distribution in the Vertical Manifold of the Microchannel Tube Heat Exchanger ACRC Report CR-73 2010 University of Illinois at Urbana-Champaign
    • (2010) ACRC Report CR-73
    • Zou, Y.1    Hrnjak, P.S.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.