메뉴 건너뛰기




Volumn 8, Issue 10, 2013, Pages

Algorithms for spectral calibration of energy-resolving small-pixel detectors

Author keywords

Pattern recognition, cluster finding, calibration and fitting methods; Pixelated detectors and associated VLSI electronics; Solid state detectors

Indexed keywords

AUTOMATED ALGORITHMS; CHARACTERISTIC X RAYS; FITTING METHOD; IMAGING APPLICATIONS; SEARCHING ALGORITHMS; SOLID STATE DETECTORS; SPECTROSCOPIC IMAGING; VLSI ELECTRONICS;

EID: 84887123580     PISSN: None     EISSN: 17480221     Source Type: Journal    
DOI: 10.1088/1748-0221/8/10/P10024     Document Type: Article
Times cited : (8)

References (17)
  • 1
    • 84872088810 scopus 로고    scopus 로고
    • A laboratory system for element specific hyperspectral X-ray imaging
    • 10.1039/c2an36157d 0003-2654
    • S.D. Jacques et al. 2013 A laboratory system for element specific hyperspectral X-ray imaging, Analyst 138 755
    • (2013) Analyst , vol.138 , Issue.3 , pp. 755
    • Jacques, S.D.1
  • 2
    • 84875537583 scopus 로고    scopus 로고
    • Pixelated diffraction signatures for explosive detection
    • D. O'Flynn et al. 2012 Pixelated diffraction signatures for explosive detection,in Detection and Sensing of Mines, Explosive Objects, and Obscured Targets XVII, Proc. SPIE 8357
    • (2012) Proc. SPIE , vol.8357
    • O'Flynn, D.1
  • 3
    • 79955786250 scopus 로고    scopus 로고
    • K-edge subtraction imaging using a pixellated energy-resolving detector
    • S. Pani et al. 2011 K-edge subtraction imaging using a pixellated energy-resolving detector, Proc. SPIE 7961 79614C
    • (2011) Proc. SPIE , vol.7961
    • Pani, S.1
  • 4
    • 84866321485 scopus 로고    scopus 로고
    • A CdTe detector for hyperspectral SPECT imaging
    • 1748-0221 P08027
    • J.W. Scuffham et al. 2012 A CdTe detector for hyperspectral SPECT imaging, JINST 7 P08027
    • (2012) JINST , vol.7 , Issue.8 , pp. 08027
    • Scuffham, J.W.1
  • 5
    • 84855453840 scopus 로고    scopus 로고
    • Pixellated Cd(Zn)Te high energy X-ray instrument
    • 1748-0221 C12009
    • P. Seller et al. 2011 Pixellated Cd(Zn)Te high energy X-ray instrument, JINST 6 C12009
    • (2011) JINST , vol.6 , Issue.12 , pp. 12009
    • Seller, P.1
  • 6
    • 80052947083 scopus 로고    scopus 로고
    • Small pixel CZT detector for hard X-ray spectroscopy
    • M.D. Wilson et al. 2011 Small pixel CZT detector for hard X-ray spectroscopy, Nucl. Instrum. Meth. A 652 1
    • (2011) Nucl. Instrum. Meth. , vol.652 , pp. 1
    • Wilson, M.D.1
  • 7
    • 57649200462 scopus 로고    scopus 로고
    • Impurity gettering effect of Te inclusions in CdZnTe single crystals
    • 10.1016/j.jcrysgro.2008.09.201 0022-0248
    • G. Yang et al. 2008 Impurity gettering effect of Te inclusions in CdZnTe single crystals, J. Cryst. Growth 311 99
    • (2008) J. Cryst. Growth , vol.311 , Issue.1 , pp. 99
    • Yang, G.1
  • 8
    • 84864484141 scopus 로고    scopus 로고
    • X-ray microbeam characterisation of a small pixel spectroscopic CdTe detector
    • 1748-0221 P07017
    • M.C. Veale, S.J. Bell, P. Seller, M.D. Wilson and V. Kachkanov 2012 X-ray microbeam characterisation of a small pixel spectroscopic CdTe detector, JINST 7 P07017
    • (2012) JINST , vol.7 , Issue.7 , pp. 07017
    • Veale, M.C.1    Bell, S.J.2    Seller, P.3    Wilson, M.D.4    Kachkanov, V.5
  • 9
    • 16544364365 scopus 로고
    • A method for automatic identification of peaks in the presence of background and its application to spectrum analysis
    • 10.1016/0029-554X(67)90058-4 0029-554X
    • M.A. Mariscotti 1967 A method for automatic identification of peaks in the presence of background and its application to spectrum analysis, Nucl. Instrum. Meth. 50 309
    • (1967) Nucl. Instrum. Meth. , vol.50 , Issue.2 , pp. 309
    • Mariscotti, M.A.1
  • 10
    • 0016563447 scopus 로고
    • A new peak search method for an automatic spectrum analysis program
    • 10.1016/0029-554X(75)90523-6 0029-554X
    • H.P. Blok, J.C. de Lange and J.W. Schotman 1975 A new peak search method for an automatic spectrum analysis program, Nucl. Instrum. Meth. 128 545
    • (1975) Nucl. Instrum. Meth. , vol.128 , Issue.3 , pp. 545
    • Blok, H.P.1    De Lange, J.C.2    Schotman, J.W.3
  • 11
    • 0042233568 scopus 로고    scopus 로고
    • A peak-search method based on spectrum convolution
    • 10.1088/0022-3727/36/15/323 0022-3727
    • A. Likar and T. Vidmar 2003 A peak-search method based on spectrum convolution, J. Appl. Phys. D 36 1903
    • (2003) J. Appl. Phys. D , vol.36 , Issue.15 , pp. 1903
    • Likar, A.1    Vidmar, T.2
  • 12
    • 79959818317 scopus 로고    scopus 로고
    • Precise energy calibration of pixel detector working in time-over-threshold mode
    • 10.1016/j.nima.2010.06.183 0168-9002
    • J. Jakubek 2011 Precise energy calibration of pixel detector working in time-over-threshold mode, Nucl. Instrum. Meth. A 633 S262
    • (2011) Nucl. Instrum. Meth. A , vol.633 , pp. 262
    • Jakubek, J.1
  • 13
    • 84876282034 scopus 로고    scopus 로고
    • Multiple module pixellated CdTe spectroscopic X-Ray detector
    • 10.1109/TNS.2013.2240694 0018-9499
    • M.D. Wilson et al. 2013 Multiple Module Pixellated CdTe Spectroscopic X-Ray Detector, IEEE T. Nucl. Sci. 60 1197
    • (2013) IEEE T. Nucl. Sci. , vol.60 , Issue.2 , pp. 1197
    • Wilson, M.D.1
  • 15
    • 80054070292 scopus 로고    scopus 로고
    • An ASIC for the study of charge sharing effects in small pixel CdZnTe X-ray detectors
    • 10.1109/TNS.2011.2162746 0018-9499
    • M.C. Veale et al. 2011 An ASIC for the study of charge sharing effects in small pixel CdZnTe X-ray detectors, IEEE T. Nucl. Sci. 58 2357
    • (2011) IEEE T. Nucl. Sci. , vol.58 , Issue.5 , pp. 2357
    • Veale, M.C.1
  • 16
    • 48349129474 scopus 로고    scopus 로고
    • Effects of Te inclusions on the performance of CdZnTe radiation detectors
    • A.E. Bolotnikov et al. 2007 Effects of Te inclusions on the performance of CdZnTe radiation detectors, IEEE Nucl. Sci. Conf. R. 3 1788
    • (2007) IEEE Nucl. Sci. Conf. R. , vol.3 , pp. 1788
    • Bolotnikov, A.E.1
  • 17
    • 69549088937 scopus 로고    scopus 로고
    • Extended defects in CdZnTe radiation detectors
    • 10.1109/TNS.2009.2019960 0018-9499
    • A.E. Bolotnikov et al. 2009 Extended Defects in CdZnTe Radiation Detectors, IEEE T. Nucl. Sci. 56 1775
    • (2009) IEEE T. Nucl. Sci. , vol.56 , Issue.4 , pp. 1775
    • Bolotnikov, A.E.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.