메뉴 건너뛰기




Volumn 7961, Issue , 2011, Pages

K-edge subtraction imaging using a pixellated energy-resolving detector

Author keywords

Cadmium Zinc Telluride; K edge subtraction; pixellated spectroscopic detectors

Indexed keywords

ACTIVE AREA; CADMIUM ZINC TELLURIDE DETECTORS; CADMIUM ZINC TELLURIDES; CONTRAST AGENT; ENERGY-RESOLVING DETECTORS; INTEGRATION WINDOW; K-EDGE SUBTRACTION; K-EDGE SUBTRACTION IMAGING; PIXELLATED SPECTROSCOPIC DETECTORS; SPECTROSCOPIC INFORMATION; TEST OBJECT;

EID: 79955786250     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.876577     Document Type: Conference Paper
Times cited : (15)

References (8)
  • 1
    • 33747624426 scopus 로고    scopus 로고
    • Evaluation of the minimum iodine concentration for contrast-enhanced subtraction mammography
    • DOI 10.1088/0031-9155/51/17/008, PII S0031915506223376, 008
    • Baldelli, P., Bravin, A., Di Maggio, C., Gennaro, G., Sarnelli, A., Taibi, A., Gambaccini, M. "Evaluation of the minimum iodine concentration for contrast-enhanced subtraction mammography". Phys Med Biol 51, 4233-4251 (2006). (Pubitemid 44261842)
    • (2006) Physics in Medicine and Biology , vol.51 , Issue.17 , pp. 4233-4251
    • Baldelli, P.1    Bravin, A.2    Di Maggio, C.3    Gennaro, G.4    Sarnelli, A.5    Taibi, A.6    Gambaccini, M.7
  • 3
    • 33645213493 scopus 로고    scopus 로고
    • Performance of the K-edge digital subtraction angiography imaging system at the European synchrotron radiation facility
    • Peterzol, A., Bravin, A., Coan, P., Elleaume, H. "Performance of the K-edge digital subtraction angiography imaging system at the European synchrotron radiation facility". Radiat Prot Dosimetry 117, 44-49 (2005).
    • (2005) Radiat Prot Dosimetry , vol.117 , pp. 44-49
    • Peterzol, A.1    Bravin, A.2    Coan, P.3    Elleaume, H.4
  • 5
    • 0141629469 scopus 로고    scopus 로고
    • Dual-energy contrast-enhanced digital subtraction mammography: Feasibility
    • DOI 10.1148/radiol.2291021276
    • Lewin, J.M., Isaacs,P.K., Vance, V. and Larke, F.J. "Dual-energy contrast-enhanced subtraction mammography: feasibility" Radiology 229, 261-268 (2003). (Pubitemid 37152134)
    • (2003) Radiology , vol.229 , Issue.1 , pp. 261-268
    • Lewin, J.M.1    Isaacs, P.K.2    Vance, V.3    Larke, F.J.4
  • 7
    • 65749098076 scopus 로고    scopus 로고
    • HEXITEC ASIC-a pixellated readout chip for CZT detectors
    • Jones, L., Seller, P., Wilson, M., Hardie, A. "HEXITEC ASIC-a pixellated readout chip for CZT detectors". Nucl Instr Meth A 604, 34-37 (2009).
    • (2009) Nucl Instr Meth A , vol.604 , pp. 34-37
    • Jones, L.1    Seller, P.2    Wilson, M.3    Hardie, A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.