메뉴 건너뛰기




Volumn 189, Issue , 2013, Pages 179-186

Resolution of amino acid mixtures by an array of potentiometric sensors based on boronic acid derivative in a SIA flow system

Author keywords

Amino acids analysis; Automated electronic tongue; Boronic acids; Ion selective electrodes; Sequential injection analysis

Indexed keywords

ARRAY OF POTENTIOMETRIC SENSORS; BORONIC ACID; CHEMOMETRIC TREATMENT; FLOW-THROUGH SENSOR; MEASUREMENT SYSTEM; PARTIAL LEAST SQUARES ANALYSIS; SEQUENTIAL INJECTION ANALYSIS; SIMULTANEOUS DETERMINATIONS;

EID: 84887080275     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2013.02.089     Document Type: Article
Times cited : (15)

References (41)
  • 3
    • 0038306717 scopus 로고    scopus 로고
    • Diagnosis of maple syrup urine disease by determination of l-valine, l-isoleucine, l-leucine and l-phenylalanine in neonatal blood spots by gas chromatography-mass spectrometry
    • C. Deng, and Y. Deng Diagnosis of maple syrup urine disease by determination of l-valine, l-isoleucine, l-leucine and l-phenylalanine in neonatal blood spots by gas chromatography-mass spectrometry Journal of Chromatography B 792 2003 261 268
    • (2003) Journal of Chromatography B , vol.792 , pp. 261-268
    • Deng, C.1    Deng, Y.2
  • 4
    • 0033826920 scopus 로고    scopus 로고
    • Adult care in phenylketonuria and hyperphenylalaninaemia: The relevance of neurological abnormalities
    • D.P. Brenton, and J. Pietz Adult care in phenylketonuria and hyperphenylalaninaemia: the relevance of neurological abnormalities European Journal of Pediatrics 159 2000 S114 S120
    • (2000) European Journal of Pediatrics , vol.159
    • Brenton, D.P.1    Pietz, J.2
  • 6
    • 0037420705 scopus 로고    scopus 로고
    • Simultaneous measurement of phenylalanine and tyrosine in phenylketonuric plasma and dried blood by high-performance liquid chromatography
    • Y. Dale, V. Mackey, R. Mushi, A. Nyanda, M. Maleque, and J. Ike Simultaneous measurement of phenylalanine and tyrosine in phenylketonuric plasma and dried blood by high-performance liquid chromatography Journal of Chromatography B 788 2003 1 8
    • (2003) Journal of Chromatography B , vol.788 , pp. 1-8
    • Dale, Y.1    Mackey, V.2    Mushi, R.3    Nyanda, A.4    Maleque, M.5    Ike, J.6
  • 9
    • 84887049673 scopus 로고    scopus 로고
    • Free amino acids concentrations in serum in children and adolescents with hyperthyroidism
    • B. Gołȩbiowska-Gȩgała, and L. Szewczyk Free amino acids concentrations in serum in children and adolescents with hyperthyroidism Pediatric Endocrinology 4 2005 17 30
    • (2005) Pediatric Endocrinology , vol.4 , pp. 17-30
    • Gołȩbiowska-Gȩgała, B.1    Szewczyk, L.2
  • 10
    • 33645024313 scopus 로고    scopus 로고
    • Determination of amino acids in saliva using capillary electrophoresis with fluorimetric detection
    • E. Poboży, W. Czarkowska, and M. Trojanowicz Determination of amino acids in saliva using capillary electrophoresis with fluorimetric detection Journal of Biochemical and Biophysical Methods 67 2006 37 47
    • (2006) Journal of Biochemical and Biophysical Methods , vol.67 , pp. 37-47
    • Pobozy, E.1    Czarkowska, W.2    Trojanowicz, M.3
  • 11
    • 34347239996 scopus 로고    scopus 로고
    • Electrochemical strategies for the label-free detection of amino acids, peptides and proteins
    • G. Herzog, and D.W. Arrigan Electrochemical strategies for the label-free detection of amino acids, peptides and proteins Analyst 132 2007 615 632
    • (2007) Analyst , vol.132 , pp. 615-632
    • Herzog, G.1    Arrigan, D.W.2
  • 12
    • 22244452671 scopus 로고    scopus 로고
    • Amino acid determination using screen-printed electrochemical sensors
    • M. Vasjari, A. Merkoci, J.P. Hart, and S. Alegret Amino acid determination using screen-printed electrochemical sensors Microchimica Acta 150 2005 233 238
    • (2005) Microchimica Acta , vol.150 , pp. 233-238
    • Vasjari, M.1    Merkoci, A.2    Hart, J.P.3    Alegret, S.4
  • 13
    • 33846543043 scopus 로고    scopus 로고
    • Electrochemical sensor for amino acids and albumin based on composites containing carbon nanotubes and copper microparticles
    • G.L. Luque, N.F. Ferreyra, and G.A. Rivas Electrochemical sensor for amino acids and albumin based on composites containing carbon nanotubes and copper microparticles Talanta 71 2007 1282 1287
    • (2007) Talanta , vol.71 , pp. 1282-1287
    • Luque, G.L.1    Ferreyra, N.F.2    Rivas, G.A.3
  • 14
    • 0027193384 scopus 로고
    • Potentiometric discrimination of organic amines by a liquid membrane electrode based on a lipophilic hexaester of calix[6] arene
    • K. Odashima, K. Yagi, K. Tohda, and Y. Umezawa Potentiometric discrimination of organic amines by a liquid membrane electrode based on a lipophilic hexaester of calix[6] arene Analytical Chemistry 65 1993 1074 1083
    • (1993) Analytical Chemistry , vol.65 , pp. 1074-1083
    • Odashima, K.1    Yagi, K.2    Tohda, K.3    Umezawa, Y.4
  • 15
  • 17
    • 0033168726 scopus 로고    scopus 로고
    • PVC-based Mn(III) porphyrin membrane-coated graphite electrode for determination of histidine
    • M.K. Amini, S. Shahrokhian, and S. Tangestaninejad PVC-based Mn(III) porphyrin membrane-coated graphite electrode for determination of histidine Analytical Chemistry 71 1999 2502 2505
    • (1999) Analytical Chemistry , vol.71 , pp. 2502-2505
    • Amini, M.K.1    Shahrokhian, S.2    Tangestaninejad, S.3
  • 18
    • 0039129250 scopus 로고    scopus 로고
    • Novel potentiometric sensor for the determination of cysteine based on substituted poly(diphenylporphyrins and metalloporphyrins)
    • R. Volf, T.V. Shishkanova, and V. Kral Novel potentiometric sensor for the determination of cysteine based on substituted poly(diphenylporphyrins and metalloporphyrins) Journal of Inclusion Phenomena and Macrocyclic Chemistry 35 1999 111 122
    • (1999) Journal of Inclusion Phenomena and Macrocyclic Chemistry , vol.35 , pp. 111-122
    • Volf, R.1    Shishkanova, T.V.2    Kral, V.3
  • 19
    • 0035894261 scopus 로고    scopus 로고
    • Lead phthalocyanine as a selective carrier for preparation of a cysteine-selective electrode
    • S. Shahrokhian Lead phthalocyanine as a selective carrier for preparation of a cysteine-selective electrode Analytical Chemistry 73 2001 5972 5978
    • (2001) Analytical Chemistry , vol.73 , pp. 5972-5978
    • Shahrokhian, S.1
  • 20
    • 0034287169 scopus 로고    scopus 로고
    • Ion-selective electrodes for determination of phenylalanine based on uranyl complexes of phosphoryl-containing podands
    • N.V. Shvedene, L.P. Berdnikova, V.E. Baulin, and I.V. Pletnev Ion-selective electrodes for determination of phenylalanine based on uranyl complexes of phosphoryl-containing podands Russian Chemical Bulletin 49 2000 1712 1714
    • (2000) Russian Chemical Bulletin , vol.49 , pp. 1712-1714
    • Shvedene, N.V.1    Berdnikova, L.P.2    Baulin, V.E.3    Pletnev, I.V.4
  • 21
    • 33846609600 scopus 로고    scopus 로고
    • Trifluoroacetophenone derivatives as amino acid selective ionophores for the potentiometric determination of phenylalanine
    • S. Sasaki, A. Hashizume, D. Citterio, E. Fuji, and K. Suzuki Trifluoroacetophenone derivatives as amino acid selective ionophores for the potentiometric determination of phenylalanine Angewandte Chemie 114 2002 3131 3133
    • (2002) Angewandte Chemie , vol.114 , pp. 3131-3133
    • Sasaki, S.1    Hashizume, A.2    Citterio, D.3    Fuji, E.4    Suzuki, K.5
  • 23
    • 80955158207 scopus 로고    scopus 로고
    • Construction of a potentiometric glutamate biosensor for determination of glutamate in some real samples
    • D. Yilmaz, and E. Karakus Construction of a potentiometric glutamate biosensor for determination of glutamate in some real samples Artificial Cells, Blood Substitutes, and Biotechnology 39 2011 385 391
    • (2011) Artificial Cells, Blood Substitutes, and Biotechnology , vol.39 , pp. 385-391
    • Yilmaz, D.1    Karakus, E.2
  • 24
    • 33645861385 scopus 로고    scopus 로고
    • Enantioselective sensing of chiral amino acids by potentiometric sensors based on optical active polyaniline films
    • X. Yin, J. Ding, S. Zhang, and J. Kong Enantioselective sensing of chiral amino acids by potentiometric sensors based on optical active polyaniline films Biosensors and Bioelectronics 21 2006 2184 2187
    • (2006) Biosensors and Bioelectronics , vol.21 , pp. 2184-2187
    • Yin, X.1    Ding, J.2    Zhang, S.3    Kong, J.4
  • 25
    • 64749111433 scopus 로고    scopus 로고
    • Chiral ligand exchange potentiometric aspartic acid sensors with polysiloxane films containing a chiral ligand N-carbobenzoxy-aspartic acid
    • Y. Zhou, T. Nagaoka, B. Yu, and K. Levon Chiral ligand exchange potentiometric aspartic acid sensors with polysiloxane films containing a chiral ligand N-carbobenzoxy-aspartic acid Analytical Chemistry 81 2009 1888 1892
    • (2009) Analytical Chemistry , vol.81 , pp. 1888-1892
    • Zhou, Y.1    Nagaoka, T.2    Yu, B.3    Levon, K.4
  • 26
    • 79959501611 scopus 로고    scopus 로고
    • Classification of amino acids and oligopeptides with the use of multi-mode chemical images obtained with ion-selective electrode array
    • P. Ciosek, M. Jańczyk, and W. Wróblewski Classification of amino acids and oligopeptides with the use of multi-mode chemical images obtained with ion-selective electrode array Analytica Chimica Acta 699 2011 26 32
    • (2011) Analytica Chimica Acta , vol.699 , pp. 26-32
    • Ciosek, P.1    Jańczyk, M.2    Wróblewski, W.3
  • 27
    • 12044251551 scopus 로고
    • α-Amino acid chelative complexation by an arylboronic acid
    • K.L. Mohler, and A.W. Czarnik α-Amino acid chelative complexation by an arylboronic acid Journal of American Chemical Society 115 1993 7037 7038
    • (1993) Journal of American Chemical Society , vol.115 , pp. 7037-7038
    • Mohler, K.L.1    Czarnik, A.W.2
  • 29
    • 77957903120 scopus 로고    scopus 로고
    • Monitoring of periodic anaerobic digestion with flow-through array of miniaturized ion-selective electrodes
    • E. Witkowska, A. Buczkowska, A. Zamojska, K.W. Szewczyk, and P. Ciosek Monitoring of periodic anaerobic digestion with flow-through array of miniaturized ion-selective electrodes Bioelectrochemistry 80 2010 87 93
    • (2010) Bioelectrochemistry , vol.80 , pp. 87-93
    • Witkowska, E.1    Buczkowska, A.2    Zamojska, A.3    Szewczyk, K.W.4    Ciosek, P.5
  • 30
    • 84961974726 scopus 로고    scopus 로고
    • Modular flow-through cell of the ion-selective electrode for water quality monitoring
    • J. Markiewicz, J. Taff, B. Wysocki, W. Wróblewski, Modular flow-through cell of the ion-selective electrode for water quality monitoring, Polish Patent Application PL 212005 B1 (2012).
    • (2012) Polish Patent Application PL 212005 B1
    • Markiewicz, J.1
  • 32
    • 33645149768 scopus 로고    scopus 로고
    • Virtual instrument for an automated potentiometric e-tongue employing the SIA technique
    • A. Durán, M. Cortina, L. Velasco, J. Rodríguez, S. Alegret, and M. del Valle Virtual instrument for an automated potentiometric e-tongue employing the SIA technique Sensors 6 2005 19 29
    • (2005) Sensors , vol.6 , pp. 19-29
    • Durán, A.1    Cortina, M.2    Velasco, L.3    Rodríguez, J.4    Alegret, S.5    Del Valle, M.6
  • 33
    • 77955418687 scopus 로고    scopus 로고
    • SIA system employing the transient response from a potentiometric sensor array - Correction of a saline matrix effect
    • A. Mimendia, J.M. Gutiérrez, L.J. Opalski, P. Ciosek, W. Wróblewski, and M. del Valle SIA system employing the transient response from a potentiometric sensor array - correction of a saline matrix effect Talanta 82 2010 931 938
    • (2010) Talanta , vol.82 , pp. 931-938
    • Mimendia, A.1    Gutiérrez, J.M.2    Opalski, L.J.3    Ciosek, P.4    Wróblewski, W.5    Del Valle, M.6
  • 34
    • 33746238578 scopus 로고    scopus 로고
    • A sequential injection electronic tongue employing the transient response from potentiometric sensors for anion multidetermination
    • M. Cortina, A. Duran, S. Alegret, and M. del Valle A sequential injection electronic tongue employing the transient response from potentiometric sensors for anion multidetermination Analytical and Bioanalytical Chemistry 385 2006 1186 1194
    • (2006) Analytical and Bioanalytical Chemistry , vol.385 , pp. 1186-1194
    • Cortina, M.1    Duran, A.2    Alegret, S.3    Del Valle, M.4
  • 35
    • 71649115519 scopus 로고    scopus 로고
    • Two analyte calibrations from the transient response of a single potentiometric sensor employed with the SIA technique
    • R. Cartas, A. Mimendia, A. Legin, and M. del Valle Two analyte calibrations from the transient response of a single potentiometric sensor employed with the SIA technique Talanta 80 2010 1428 1435
    • (2010) Talanta , vol.80 , pp. 1428-1435
    • Cartas, R.1    Mimendia, A.2    Legin, A.3    Del Valle, M.4
  • 36
    • 0142071014 scopus 로고    scopus 로고
    • Selection of quasi-optimal inputs in chemometrics modeling by artificial neural network analysis
    • Z. Boger Selection of quasi-optimal inputs in chemometrics modeling by artificial neural network analysis Analytica Chimica Acta 490 2003 31 40
    • (2003) Analytica Chimica Acta , vol.490 , pp. 31-40
    • Boger, Z.1
  • 37
    • 83455238092 scopus 로고    scopus 로고
    • Resolution of phenolic antioxidant mixtures employing a voltammetric bio-electronic tongue
    • X. Cetó, F. Céspedes, M.I. Pividori, J.M. Gutiérrez, and M. del Valle Resolution of phenolic antioxidant mixtures employing a voltammetric bio-electronic tongue Analyst 137 2012 349 356
    • (2012) Analyst , vol.137 , pp. 349-356
    • Cetó, X.1    Céspedes, F.2    Pividori, M.I.3    Gutiérrez, J.M.4    Del Valle, M.5
  • 39
    • 0034228462 scopus 로고    scopus 로고
    • Computational methods for the analysis of chemical sensor array data from volatile analytes
    • P.C. Jurs, G.A. Bakken, and H.E. McClelland Computational methods for the analysis of chemical sensor array data from volatile analytes Chemical Reviews 1000 2000 2649 2678
    • (2000) Chemical Reviews , vol.1000 , pp. 2649-2678
    • Jurs, P.C.1    Bakken, G.A.2    McClelland, H.E.3
  • 41
    • 85027958640 scopus 로고    scopus 로고
    • A simple method for the analysis by MS/MS of underivatized amino acids on dry blood spots from newborn screening
    • C. Wang, W. Zhang, F. Song, Z. Liu, and S. Liu A simple method for the analysis by MS/MS of underivatized amino acids on dry blood spots from newborn screening Amino Acids 42 2012 1889 1895
    • (2012) Amino Acids , vol.42 , pp. 1889-1895
    • Wang, C.1    Zhang, W.2    Song, F.3    Liu, Z.4    Liu, S.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.