메뉴 건너뛰기




Volumn 68, Issue 11, 2013, Pages 1124-1131

Transfer of airway skills from manikin training to patient: Success of ventilation with facemask or LMA-Supreme™ by medical students

Author keywords

[No Author keywords available]

Indexed keywords

PROPOFOL; SUFENTANIL;

EID: 84886911795     PISSN: 00032409     EISSN: 13652044     Source Type: Journal    
DOI: 10.1111/anae.12367     Document Type: Article
Times cited : (26)

References (25)
  • 1
    • 33746868388 scopus 로고    scopus 로고
    • Prehospital airway management: A prospective evaluation of anaesthesia trained emergency physicians
    • Timmermann A, Eich C, Russo SG, et al. Prehospital airway management: a prospective evaluation of anaesthesia trained emergency physicians. Resuscitation 2006; 70: 179-85.
    • (2006) Resuscitation , vol.70 , pp. 179-185
    • Timmermann, A.1    Eich, C.2    Russo, S.G.3
  • 3
    • 78049478848 scopus 로고    scopus 로고
    • European Resuscitation Council Guidelines for Resuscitation 2010: Section 4. Adult advanced life support
    • Deakin CD, Nolan JP, Soar J, et al. European Resuscitation Council Guidelines for Resuscitation 2010: Section 4. Adult advanced life support. Resuscitation 2010; 81: 1305-52.
    • (2010) Resuscitation , vol.81 , pp. 1305-1352
    • Deakin, C.D.1    Nolan, J.P.2    Soar, J.3
  • 4
    • 0037406762 scopus 로고    scopus 로고
    • Practice guidelines for management of the difficult airway: An updated report by the American Society of Anesthesiologists Task Force on management of the Difficult Airway
    • American Society of Anesthesiologists Task Force on management of the Difficult Airway.
    • American Society of Anesthesiologists Task Force on management of the Difficult Airway. Practice guidelines for management of the difficult airway: an updated report by the American Society of Anesthesiologists Task Force on management of the Difficult Airway. Anesthesiology 2003; 98: 1269-77.
    • (2003) Anesthesiology , vol.98 , pp. 1269-1277
  • 5
    • 80054816653 scopus 로고    scopus 로고
    • Laypersons can successfully place supraglottic airways with 3 minutes of training. A comparison of four different devices in the manikin
    • Schalte G, Stoppe C, Aktas M, et al. Laypersons can successfully place supraglottic airways with 3 minutes of training. A comparison of four different devices in the manikin. Scandinavian Journal of Trauma, Resuscitation and Emergency Medicine 2011; 19: 60.
    • (2011) Scandinavian Journal of Trauma, Resuscitation and Emergency Medicine , vol.19 , pp. 60
    • Schalte, G.1    Stoppe, C.2    Aktas, M.3
  • 6
    • 84857050172 scopus 로고    scopus 로고
    • Comparison of air-Q® and Soft Seal® laryngeal mask for airway management by novice doctors during infant chest compression: A manikin study
    • Komasawa N, Ueki R, Yamamoto N, et al. Comparison of air-Q® and Soft Seal® laryngeal mask for airway management by novice doctors during infant chest compression: a manikin study. Resuscitation 2012; 83: 365-8.
    • (2012) Resuscitation , vol.83 , pp. 365-368
    • Komasawa, N.1    Ueki, R.2    Yamamoto, N.3
  • 7
    • 84861610328 scopus 로고    scopus 로고
    • Degrees of reality: Airway anatomy of high-fidelity human patient simulators and airway trainers
    • Schebesta K, Hupfl M, Rossler B, Ringl H, Muller MP, Kimberger O,. Degrees of reality: airway anatomy of high-fidelity human patient simulators and airway trainers. Anesthesiology 2012; 116: 1204-9.
    • (2012) Anesthesiology , vol.116 , pp. 1204-1209
    • Schebesta, K.1    Hupfl, M.2    Rossler, B.3    Ringl, H.4    Muller, M.P.5    Kimberger, O.6
  • 8
    • 78650658494 scopus 로고    scopus 로고
    • Evaluation of airway equipment: Man or manikin?
    • Rai MR, Popat MT,. Evaluation of airway equipment: man or manikin? Anaesthesia 2011; 66: 1-3.
    • (2011) Anaesthesia , vol.66 , pp. 1-3
    • Rai, M.R.1    Popat, M.T.2
  • 9
    • 81155146136 scopus 로고    scopus 로고
    • Supraglottic airways in difficult airway management: Successes, failures, use and misuse
    • Timmermann A,. Supraglottic airways in difficult airway management: successes, failures, use and misuse. Anaesthesia 2011; 66: 45-56.
    • (2011) Anaesthesia , vol.66 , pp. 45-56
    • Timmermann, A.1
  • 10
    • 54849423427 scopus 로고    scopus 로고
    • Laryngeal mask LMA Supreme™. Application by medical personnel inexperienced in airway management
    • Timmermann A, Cremer S, Heuer J, Braun U, Graf BM, Russo SG,. Laryngeal mask LMA Supreme™. Application by medical personnel inexperienced in airway management. Anaesthesist 2008; 57: 970-5.
    • (2008) Anaesthesist , vol.57 , pp. 970-975
    • Timmermann, A.1    Cremer, S.2    Heuer, J.3    Braun, U.4    Graf, B.M.5    Russo, S.G.6
  • 11
    • 73949097241 scopus 로고    scopus 로고
    • LMA Supreme™ versus facemask ventilation performed by novices: A comparative study in morbidly obese patients showing difficult ventilation predictors
    • Abdi W, Dhonneur G, Amathieu R, et al. LMA Supreme™ versus facemask ventilation performed by novices: a comparative study in morbidly obese patients showing difficult ventilation predictors. Obesity Surgery 2009; 19: 1624-30.
    • (2009) Obesity Surgery , vol.19 , pp. 1624-1630
    • Abdi, W.1    Dhonneur, G.2    Amathieu, R.3
  • 12
    • 0030478568 scopus 로고    scopus 로고
    • Jaw thrusting as a clinical test to assess the adequate depth of anaesthesia for insertion of the laryngeal mask
    • Drage MP, Nunez J, Vaughan RS, Asai T,. Jaw thrusting as a clinical test to assess the adequate depth of anaesthesia for insertion of the laryngeal mask. Anaesthesia 1996; 51: 1167-70.
    • (1996) Anaesthesia , vol.51 , pp. 1167-1170
    • Drage, M.P.1    Nunez, J.2    Vaughan, R.S.3    Asai, T.4
  • 14
    • 18644365999 scopus 로고    scopus 로고
    • Prime the ProSeal™ drain tube with lube from a tube!
    • Brimacombe J, Keller C,. Prime the ProSeal™ drain tube with lube from a tube!. Canadian Journal of Anesthesia 2005; 52: 338-9.
    • (2005) Canadian Journal of Anesthesia , vol.52 , pp. 338-339
    • Brimacombe, J.1    Keller, C.2
  • 15
    • 79956064778 scopus 로고    scopus 로고
    • Evaluation of airway equipment: Man or manikin?
    • Cook TM, Howes B, Wharton N,. Evaluation of airway equipment: man or manikin? Anaesthesia 2011; 66: 529.
    • (2011) Anaesthesia , vol.66 , pp. 529
    • Cook, T.M.1    Howes, B.2    Wharton, N.3
  • 16
    • 77949691561 scopus 로고    scopus 로고
    • LMA Supreme™ insertion by novices in manikins and patients
    • Howes BW, Wharton NM, Gibbison B, Cook TM,. LMA Supreme™ insertion by novices in manikins and patients. Anaesthesia 2010; 65: 343-7.
    • (2010) Anaesthesia , vol.65 , pp. 343-347
    • Howes, B.W.1    Wharton, N.M.2    Gibbison, B.3    Cook, T.M.4
  • 17
    • 84858335845 scopus 로고    scopus 로고
    • LMA Supreme™ vs i-gel™ - A comparison of insertion success in novices
    • Ragazzi R, Finessi L, Farinelli I, Alvisi R, Volta CA,. LMA Supreme™ vs i-gel™-a comparison of insertion success in novices. Anaesthesia 2012; 67: 384-8.
    • (2012) Anaesthesia , vol.67 , pp. 384-388
    • Ragazzi, R.1    Finessi, L.2    Farinelli, I.3    Alvisi, R.4    Volta, C.A.5
  • 18
    • 28644442986 scopus 로고    scopus 로고
    • Recommendations for airway control and difficult airway management
    • Petrini F, Accorsi A, Adrario E, et al. Recommendations for airway control and difficult airway management. Minerva Anestesiologica 2005; 71: 617-57.
    • (2005) Minerva Anestesiologica , vol.71 , pp. 617-657
    • Petrini, F.1    Accorsi, A.2    Adrario, E.3
  • 20
    • 0031725203 scopus 로고    scopus 로고
    • The incidence of regurgitation during cardiopulmonary resuscitation: A comparison between the bag valve mask and laryngeal mask airway
    • Stone BJ, Chantler PJ, Baskett PJ,. The incidence of regurgitation during cardiopulmonary resuscitation: a comparison between the bag valve mask and laryngeal mask airway. Resuscitation 1998; 38: 3-6.
    • (1998) Resuscitation , vol.38 , pp. 3-6
    • Stone, B.J.1    Chantler, P.J.2    Baskett, P.J.3
  • 21
    • 0032983085 scopus 로고    scopus 로고
    • Airway management during cardiopulmonary resuscitation - A comparative study of bag-valve-mask, laryngeal mask airway and combitube in a bench model
    • Doerges V, Sauer C, Ocker H, Wenzel V, Schmucker P,. Airway management during cardiopulmonary resuscitation-a comparative study of bag-valve-mask, laryngeal mask airway and combitube in a bench model. Resuscitation 1999; 41: 63-9.
    • (1999) Resuscitation , vol.41 , pp. 63-69
    • Doerges, V.1    Sauer, C.2    Ocker, H.3    Wenzel, V.4    Schmucker, P.5
  • 23
    • 61549088467 scopus 로고    scopus 로고
    • Prospective clinical and fiberoptic evaluation of the Supreme laryngeal mask airway™
    • Timmermann A, Cremer S, Eich C, et al. Prospective clinical and fiberoptic evaluation of the Supreme laryngeal mask airway™. Anesthesiology 2009; 110: 262-5.
    • (2009) Anesthesiology , vol.110 , pp. 262-265
    • Timmermann, A.1    Cremer, S.2    Eich, C.3
  • 24
    • 79953713658 scopus 로고    scopus 로고
    • A randomized clinical comparison of the Intersurgical i-gel and LMA Unique in non-obese adults during general surgery
    • Cattano D, Ferrario L, Maddukuri V, Sridhar S, Khalil Y, Hagberg CA,. A randomized clinical comparison of the Intersurgical i-gel and LMA Unique in non-obese adults during general surgery. Minerva Anestesiologica 2011; 77: 292-7.
    • (2011) Minerva Anestesiologica , vol.77 , pp. 292-297
    • Cattano, D.1    Ferrario, L.2    Maddukuri, V.3    Sridhar, S.4    Khalil, Y.5    Hagberg, C.A.6
  • 25
    • 0034787583 scopus 로고    scopus 로고
    • Difficulties in recognizing one's own incompetence: Novice physicians who are unskilled and unaware of it
    • Hodges B, Regehr G, Martin D,. Difficulties in recognizing one's own incompetence: novice physicians who are unskilled and unaware of it. Academic Medicine 2001; 76: S87-9.
    • (2001) Academic Medicine , vol.76
    • Hodges, B.1    Regehr, G.2    Martin, D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.