메뉴 건너뛰기




Volumn 29, Issue 11, 2013, Pages 1834-1839

The degradation outcome of biocomposite suture anchors made from poly L-lactide-co-glycolide and β-tricalcium phosphate

Author keywords

[No Author keywords available]

Indexed keywords

CALCIUM PHOSPHATE; POLYGLACTIN;

EID: 84886846192     PISSN: 07498063     EISSN: 15263231     Source Type: Journal    
DOI: 10.1016/j.arthro.2013.08.004     Document Type: Article
Times cited : (43)

References (17)
  • 1
    • 0033049022 scopus 로고    scopus 로고
    • Bioabsorbable interference screws for graft fixation in anterior cruciate ligament reconstruction
    • D.A. McGuire, F.A. Barber, and B.F. Elrod Bioabsorbable interference screws for graft fixation in anterior cruciate ligament reconstruction Arthroscopy 15 1999 463 473
    • (1999) Arthroscopy , vol.15 , pp. 463-473
    • McGuire, D.A.1    Barber, F.A.2    Elrod, B.F.3
  • 2
    • 0036828516 scopus 로고    scopus 로고
    • Anterior cruciate ligament reconstruction with bioabsorbable polyglycolic acid interference screws: MR imaging follow-up
    • F.D. Bach, R.Y. Carlier, and J.B. Elis Anterior cruciate ligament reconstruction with bioabsorbable polyglycolic acid interference screws: MR imaging follow-up Radiology 225 2002 541 550
    • (2002) Radiology , vol.225 , pp. 541-550
    • Bach, F.D.1    Carlier, R.Y.2    Elis, J.B.3
  • 3
    • 41049111610 scopus 로고    scopus 로고
    • Long-term absorption of beta-tricalcium phosphate poly-L-lactic acid interference screws
    • F.A. Barber, and W.D. Dockery Long-term absorption of beta-tricalcium phosphate poly-L-lactic acid interference screws Arthroscopy 24 2008 441 447
    • (2008) Arthroscopy , vol.24 , pp. 441-447
    • Barber, F.A.1    Dockery, W.D.2
  • 4
    • 79954746799 scopus 로고    scopus 로고
    • Long-term degradation of a poly-lactide co-glycolide/beta-tricalcium phosphate biocomposite interference screw
    • F.A. Barber, W.D. Dockery, and S.A. Hrnack Long-term degradation of a poly-lactide co-glycolide/beta-tricalcium phosphate biocomposite interference screw Arthroscopy 27 2011 637 643
    • (2011) Arthroscopy , vol.27 , pp. 637-643
    • Barber, F.A.1    Dockery, W.D.2    Hrnack, S.A.3
  • 5
    • 84876933450 scopus 로고    scopus 로고
    • Cyclic loading biomechanical analysis of the pullout strengths of rotator cuff and glenoid anchors: 2013 update
    • F.A. Barber, and M.A. Herbert Cyclic loading biomechanical analysis of the pullout strengths of rotator cuff and glenoid anchors: 2013 update Arthroscopy 29 2013 832 844
    • (2013) Arthroscopy , vol.29 , pp. 832-844
    • Barber, F.A.1    Herbert, M.A.2
  • 6
    • 33746796725 scopus 로고    scopus 로고
    • Long-term absorption of poly-L-lactic acid interference screws
    • F.A. Barber, and W.D. Dockery Long-term absorption of poly-L-lactic acid interference screws Arthroscopy 22 2006 820 826
    • (2006) Arthroscopy , vol.22 , pp. 820-826
    • Barber, F.A.1    Dockery, W.D.2
  • 7
    • 2942575820 scopus 로고    scopus 로고
    • CT density measurement of bone graft within an intervertebral lumbar cage: Increase of hounsfield units as an indicator for increasing bone mineral content
    • M. Spruit, H. Meijers, and M. Obradov CT density measurement of bone graft within an intervertebral lumbar cage: Increase of hounsfield units as an indicator for increasing bone mineral content J Spinal Disord Tech 17 2004 232 235
    • (2004) J Spinal Disord Tech , vol.17 , pp. 232-235
    • Spruit, M.1    Meijers, H.2    Obradov, M.3
  • 8
    • 0037396234 scopus 로고    scopus 로고
    • In-vivo measurement of dynamic joint motion using high speed biplane radiography and CT: Application to canine ACL deficiency
    • S. Tashman, and W. Anderst In-vivo measurement of dynamic joint motion using high speed biplane radiography and CT: Application to canine ACL deficiency J Biomech Eng 125 2003 238 245
    • (2003) J Biomech Eng , vol.125 , pp. 238-245
    • Tashman, S.1    Anderst, W.2
  • 9
    • 70350188325 scopus 로고    scopus 로고
    • Magnetic resonance imaging analysis of the bioabsorbable Milagro interference screw for graft fixation in anterior cruciate ligament reconstruction
    • K.H. Frosch, T. Sawallich, and G. Schutze Magnetic resonance imaging analysis of the bioabsorbable Milagro interference screw for graft fixation in anterior cruciate ligament reconstruction Strategies Trauma Limb Reconstr 4 2009 73 79
    • (2009) Strategies Trauma Limb Reconstr , vol.4 , pp. 73-79
    • Frosch, K.H.1    Sawallich, T.2    Schutze, G.3
  • 10
    • 0031172250 scopus 로고    scopus 로고
    • Technique to control pH in vicinity of biodegrading PLA-PGA implants
    • C.M. Agrawal, and K.A. Athanasiou Technique to control pH in vicinity of biodegrading PLA-PGA implants J Biomed Mater Res 38 1997 105 114
    • (1997) J Biomed Mater Res , vol.38 , pp. 105-114
    • Agrawal, C.M.1    Athanasiou, K.A.2
  • 11
    • 33846987893 scopus 로고    scopus 로고
    • Formation of bone-like apatite enhanced by hydrolysis of octacalcium phosphate crystals deposited in collagen matrix
    • Y. Honda, S. Kamakura, and K. Sasaki Formation of bone-like apatite enhanced by hydrolysis of octacalcium phosphate crystals deposited in collagen matrix J Biomed Mater Res B Appl Biomater 80 2007 281 289
    • (2007) J Biomed Mater Res B Appl Biomater , vol.80 , pp. 281-289
    • Honda, Y.1    Kamakura, S.2    Sasaki, K.3
  • 12
    • 55349129981 scopus 로고    scopus 로고
    • Review paper: Behavior of ceramic biomaterials derived from tricalcium phosphate in physiological condition
    • M. Kamitakahara, C. Ohtsuki, and T. Miyazaki Review paper: Behavior of ceramic biomaterials derived from tricalcium phosphate in physiological condition J Biomater Appl 23 2008 197 212
    • (2008) J Biomater Appl , vol.23 , pp. 197-212
    • Kamitakahara, M.1    Ohtsuki, C.2    Miyazaki, T.3
  • 13
    • 33847622128 scopus 로고    scopus 로고
    • The effect of the microstructure of beta-tricalcium phosphate on the metabolism of subsequently formed bone tissue
    • T. Okuda, K. Ioku, and I. Yonezawa The effect of the microstructure of beta-tricalcium phosphate on the metabolism of subsequently formed bone tissue Biomaterials 28 2007 2612 2621
    • (2007) Biomaterials , vol.28 , pp. 2612-2621
    • Okuda, T.1    Ioku, K.2    Yonezawa, I.3
  • 14
    • 65049088443 scopus 로고    scopus 로고
    • The unpredictable material properties of bioabsorbable PLC interference screws and their adverse effects in ACL reconstruction surgery
    • S. Konan, and F.S. Haddad The unpredictable material properties of bioabsorbable PLC interference screws and their adverse effects in ACL reconstruction surgery Knee Surg Sports Traumatol Arthrosc 17 2009 293 297
    • (2009) Knee Surg Sports Traumatol Arthrosc , vol.17 , pp. 293-297
    • Konan, S.1    Haddad, F.S.2
  • 15
    • 57749087010 scopus 로고    scopus 로고
    • A clinical review of bioabsorbable interference screws and their adverse effects in anterior cruciate ligament reconstruction surgery
    • S. Konan, and F.S. Haddad A clinical review of bioabsorbable interference screws and their adverse effects in anterior cruciate ligament reconstruction surgery Knee 16 2009 6 13
    • (2009) Knee , vol.16 , pp. 6-13
    • Konan, S.1    Haddad, F.S.2
  • 16
    • 33746810984 scopus 로고    scopus 로고
    • False magnetic resonance imaging persistence of a biodegradable anterior cruciate ligament interference screw with chronic inflammation after 4 years in vivo
    • 911.e1-4
    • M.C. Park, and J.E. Tibone False magnetic resonance imaging persistence of a biodegradable anterior cruciate ligament interference screw with chronic inflammation after 4 years in vivo Arthroscopy 22 2006 911.e1-4
    • (2006) Arthroscopy , vol.22
    • Park, M.C.1    Tibone, J.E.2
  • 17
    • 38149062743 scopus 로고    scopus 로고
    • Rejection reaction to stabilizing bolts after ACL reconstruction: A case report
    • A.A. Lamprakis, A.P. Fortis, and A. Dimas Rejection reaction to stabilizing bolts after ACL reconstruction: A case report Knee Surg Sports Traumatol Arthrosc 16 2008 19 23
    • (2008) Knee Surg Sports Traumatol Arthrosc , vol.16 , pp. 19-23
    • Lamprakis, A.A.1    Fortis, A.P.2    Dimas, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.