-
1
-
-
0033049022
-
Bioabsorbable interference screws for graft fixation in anterior cruciate ligament reconstruction
-
DOI 10.1053/ar.1999.v15.015046001
-
D.A. McGuire, F.A. Barber, B.F. Elrod, and L.E. Paulos Bioabsorbable interference screws for graft fixation in anterior cruciate ligament reconstruction Arthroscopy 15 1999 463 473 (Pubitemid 29319191)
-
(1999)
Arthroscopy
, vol.15
, Issue.5
, pp. 463-473
-
-
McGuire, D.A.1
Barber, F.A.2
Elrod, B.F.3
Paulos, L.E.4
-
2
-
-
33750428192
-
Graft Laceration and Pullout Strength of Soft-Tissue Anterior Cruciate Ligament Reconstruction: In Vitro Study Comparing Titanium, Poly-D,L-Lactide, and Poly-D,L-Lactide-Tricalcium Phosphate Screws
-
DOI 10.1016/j.arthro.2006.06.015, PII S0749806306007572
-
T. Zantop, A. Weimann, R. Schmidtko, M. Herbort, M.J. Raschke, and W. Petersen Graft laceration and pullout strength of soft-tissue anterior cruciate ligament reconstruction: In vitro study comparing titanium, poly-d, l-lactide, and poly-d, l-lactide-tricalcium phosphate screws Arthroscopy 22 2006 1204 1210 (Pubitemid 44648667)
-
(2006)
Arthroscopy - Journal of Arthroscopic and Related Surgery
, vol.22
, Issue.11
, pp. 1204-1210
-
-
Zantop, T.1
Weimann, A.2
Schmidtko, R.3
Herbort, M.4
Raschke, M.J.5
Petersen, W.6
-
3
-
-
0033063718
-
Biology and clinical experience of absorbable materials in ACL fixation
-
F.A. Barber Biology and clinical experience of absorbable materials in ACL fixation Tech Orthop 14 1999 34 42 (Pubitemid 29323065)
-
(1999)
Techniques in Orthopaedics
, vol.14
, Issue.1
, pp. 34-42
-
-
Barber, F.A.1
-
4
-
-
0031715629
-
Orthopaedic applications for PLA-PGA biodegradable polymers
-
DOI 10.1016/S0749-8063(98)70099-4
-
K.A. Athanasiou, C.M. Agrawal, F.A. Barber, and S.S. Burkhart Orthopaedic applications for PLA-PGA biodegradable polymers Arthroscopy 14 1998 726 737 (Pubitemid 28465604)
-
(1998)
Arthroscopy
, vol.14
, Issue.7
, pp. 726-737
-
-
Athanasiou, K.A.1
Agrawal, C.M.2
Barber, F.A.3
Burkhart, S.S.4
-
5
-
-
14844307842
-
Development of a perforated biodegradable interference screw
-
DOI 10.1016/j.arthro.2004.11.014
-
P. Hunt, F.N. Unterhauser, M.J. Strobel, and A. Weiler Development of a perforated biodegradable interference screw Arthroscopy 21 2005 258 265 (Pubitemid 40341399)
-
(2005)
Arthroscopy - Journal of Arthroscopic and Related Surgery
, vol.21
, Issue.3
, pp. 258-265
-
-
Hunt, P.1
Unterhauser, F.N.2
Strobel, M.J.3
Weiler, A.4
-
6
-
-
41049111610
-
Long-term Absorption of β-Tricalcium Phosphate Poly-L-Lactic Acid Interference Screws
-
DOI 10.1016/j.arthro.2007.10.004, PII S074980630701002X
-
F.A. Barber, and W.D. Dockery Long-term absorption of beta-tricalcium phosphate poly-L-lactic acid interference screws Arthroscopy 24 2008 441 447 (Pubitemid 351423479)
-
(2008)
Arthroscopy - Journal of Arthroscopic and Related Surgery
, vol.24
, Issue.4
, pp. 441-447
-
-
Barber, F.A.1
Dockery, W.D.2
-
7
-
-
77649153282
-
Calcium phosphates: What is the evidence?
-
S. Larsson Calcium phosphates: What is the evidence? J Orthop Trauma 24 Suppl 1 2010 S41 S45
-
(2010)
J Orthop Trauma
, vol.24
, Issue.SUPPL. 1
-
-
Larsson, S.1
-
8
-
-
65049088443
-
The unpredictable material properties of bioabsorbable PLC interference screws and their adverse effects in ACL reconstruction surgery
-
S. Konan, and F.S. Haddad The unpredictable material properties of bioabsorbable PLC interference screws and their adverse effects in ACL reconstruction surgery Knee Surg Sports Traumatol Arthrosc 17 2009 293 297
-
(2009)
Knee Surg Sports Traumatol Arthrosc
, vol.17
, pp. 293-297
-
-
Konan, S.1
Haddad, F.S.2
-
9
-
-
57749087010
-
A clinical review of bioabsorbable interference screws and their adverse effects in anterior cruciate ligament reconstruction surgery
-
S. Konan, and F.S. Haddad A clinical review of bioabsorbable interference screws and their adverse effects in anterior cruciate ligament reconstruction surgery Knee 16 2009 6 13
-
(2009)
Knee
, vol.16
, pp. 6-13
-
-
Konan, S.1
Haddad, F.S.2
-
11
-
-
2942575820
-
CT density measurement of bone graft within an intervertebral lumbar cage: Increase of Hounsfield units as an indicator for increasing bone mineral content
-
M. Spruit, H. Meijers, M. Obradov, and P.G. Anderson CT density measurement of bone graft within an intervertebral lumbar cage: Increase of Hounsfield units as an indicator for increasing bone mineral content J Spinal Disord Tech 17 2004 232 235
-
(2004)
J Spinal Disord Tech
, vol.17
, pp. 232-235
-
-
Spruit, M.1
Meijers, H.2
Obradov, M.3
Anderson, P.G.4
-
12
-
-
0037396234
-
In-vivo measurement of dynamic joint motion using high speed biplane radiography and CT: Application to canine ACL deficiency
-
DOI 10.1115/1.1559896
-
S. Tashman, and W. Anderst In-vivo measurement of dynamic joint motion using high speed biplane radiography and CT: Application to canine ACL deficiency J Biomech Eng 125 2003 238 245 (Pubitemid 36506138)
-
(2003)
Journal of Biomechanical Engineering
, vol.125
, Issue.2
, pp. 238-245
-
-
Tashman, S.1
Anderst, W.2
-
13
-
-
7544231430
-
A comparison of bone tunnel measurements made using computed tomography and digital plain radiography after anterior cruciate ligament reconstruction
-
DOI 10.1016/j.arthro.2004.06.037, PII S0749806304006553
-
K.E. Webster, J.A. Feller, J. Elliott, A. Hutchison, and R. Payne A comparison of bone tunnel measurements made using computed tomography and digital plain radiography after anterior cruciate ligament reconstruction Arthroscopy 20 2004 946 950 (Pubitemid 39452267)
-
(2004)
Arthroscopy - Journal of Arthroscopic and Related Surgery
, vol.20
, Issue.9
, pp. 946-950
-
-
Webster, K.E.1
Feller, J.A.2
Elliott, J.3
Hutchison, A.4
Payne, R.5
-
14
-
-
70350188325
-
Magnetic resonance imaging analysis of the bioabsorbable Milagro interference screw for graft fixation in anterior cruciate ligament reconstruction
-
K.H. Frosch, T. Sawallich, and G. Schutze Magnetic resonance imaging analysis of the bioabsorbable Milagro interference screw for graft fixation in anterior cruciate ligament reconstruction Strategies Trauma Limb Reconstr 4 2009 73 79
-
(2009)
Strategies Trauma Limb Reconstr
, vol.4
, pp. 73-79
-
-
Frosch, K.H.1
Sawallich, T.2
Schutze, G.3
-
15
-
-
0031172250
-
Technique to control pH in vicinity of biodegrading PLA-PGA implants
-
DOI 10.1002/(SICI)1097-4636(199722)38:2<105::AID-JBM4>3.0.CO;2-U
-
C.M. Agrawal, and K.A. Athanasiou Technique to control pH in vicinity of biodegrading PLA-PGA implants J Biomed Mater Res 38 1997 105 114 (Pubitemid 27233098)
-
(1997)
Journal of Biomedical Materials Research
, vol.38
, Issue.2
, pp. 105-114
-
-
Agrawal, C.M.1
Athanasiou, K.A.2
-
16
-
-
33846987893
-
Formation of bone-like apatite enhanced by hydrolysis of octacalcium phosphate crystals deposited in collagen matrix
-
Y. Honda, S. Kamakura, K. Sasaki, and O. Suzuki Formation of bone-like apatite enhanced by hydrolysis of octacalcium phosphate crystals deposited in collagen matrix J Biomed Mater Res B Appl Biomater 80 2007 281 289
-
(2007)
J Biomed Mater Res B Appl Biomater
, vol.80
, pp. 281-289
-
-
Honda, Y.1
Kamakura, S.2
Sasaki, K.3
Suzuki, O.4
-
17
-
-
55349129981
-
Review paper: Behavior of ceramic biomaterials derived from tricalcium phosphate in physiological condition
-
M. Kamitakahara, C. Ohtsuki, and T. Miyazaki Review paper: Behavior of ceramic biomaterials derived from tricalcium phosphate in physiological condition J Biomater Appl 23 2008 197 212
-
(2008)
J Biomater Appl
, vol.23
, pp. 197-212
-
-
Kamitakahara, M.1
Ohtsuki, C.2
Miyazaki, T.3
-
18
-
-
33847622128
-
The effect of the microstructure of β-tricalcium phosphate on the metabolism of subsequently formed bone tissue
-
DOI 10.1016/j.biomaterials.2007.01.040, PII S0142961207001305
-
T. Okuda, K. Ioku, and I. Yonezawa The effect of the microstructure of beta-tricalcium phosphate on the metabolism of subsequently formed bone tissue Biomaterials 28 2007 2612 2621 (Pubitemid 46367214)
-
(2007)
Biomaterials
, vol.28
, Issue.16
, pp. 2612-2621
-
-
Okuda, T.1
Ioku, K.2
Yonezawa, I.3
Minagi, H.4
Kawachi, G.5
Gonda, Y.6
Murayama, H.7
Shibata, Y.8
Minami, S.9
Kamihira, S.10
Kurosawa, H.11
Ikeda, T.12
-
19
-
-
33748064667
-
Prospective Evaluation of Patellar Tendon Graft Fixation in Anterior Cruciate Ligament Reconstruction Comparing Composite Bioabsorbable and Allograft Interference Screws
-
DOI 10.1016/j.arthro.2006.05.010, PII S0749806306006876
-
K. Tecklenburg, P. Burkart, C. Hoser, M. Rieger, and C. Fink Prospective evaluation of patellar tendon graft fixation in anterior cruciate ligament reconstruction comparing composite bioabsorbable and allograft interference screws Arthroscopy 22 2006 993 999 (Pubitemid 44301772)
-
(2006)
Arthroscopy - Journal of Arthroscopic and Related Surgery
, vol.22
, Issue.9
, pp. 993-999
-
-
Tecklenburg, K.1
Burkart, P.2
Hoser, C.3
Rieger, M.4
Fink, C.5
-
20
-
-
33746810984
-
False magnetic resonance imaging persistence of a biodegradable anterior cruciate ligament interference screw with chronic inflammation after 4 years in vivo
-
M.C. Park, and J.E. Tibone False magnetic resonance imaging persistence of a biodegradable anterior cruciate ligament interference screw with chronic inflammation after 4 years in vivo Arthroscopy 22 2006 e1 e4
-
(2006)
Arthroscopy
, vol.22
-
-
Park, M.C.1
Tibone, J.E.2
|