메뉴 건너뛰기




Volumn , Issue , 2012, Pages 379-391

Oligosaccharide Analysis by High-Performance Anion-Exchange Chromatography Hyphenated to Integrated Pulsed Amperometric Detection and On-Line Ion-Trap Mass Spectrometry

Author keywords

HPAEC oligosaccharide analysis; IPAD hyphenation; On line ion trap MS, HPAEC IPAD

Indexed keywords


EID: 84886029186     PISSN: None     EISSN: None     Source Type: Book    
DOI: 10.1002/9781118147009.ch21     Document Type: Chapter
Times cited : (5)

References (27)
  • 1
    • 0025006627 scopus 로고
    • High-performance anion-exchange chromatography for carbohydrate analysis
    • Lee, YC. High-performance anion-exchange chromatography for carbohydrate analysis. Anal. Biochem. 1990;189(2):151-162.
    • (1990) Anal. Biochem. , vol.189 , Issue.2 , pp. 151-162
    • Lee, Y.C.1
  • 2
    • 0023752198 scopus 로고
    • High-performance anion-exchange chromatography of oligosaccharides using pellicular resins and pulsed amperometric detection.
    • Townsend RR, Hardy MR, Hindsgaul O, Lee YC. High-performance anion-exchange chromatography of oligosaccharides using pellicular resins and pulsed amperometric detection. Anal. Biochem. 1988;174(2):459-470.
    • (1988) Anal. Biochem. , vol.174 , Issue.2 , pp. 459-470
    • Townsend, R.R.1    Hardy, M.R.2    Hindsgaul, O.3    Lee, Y.C.4
  • 3
    • 0002657999 scopus 로고
    • Optimization of waveforms for pulsed amperometric detection of carbohydrates based on pulsed voltammetry
    • LaCourse WR, Johnson DC. Optimization of waveforms for pulsed amperometric detection of carbohydrates based on pulsed voltammetry. Anal.Chem. 1993;65(1):50-55.
    • (1993) Anal.Chem. , vol.65 , Issue.1 , pp. 50-55
    • LaCourse, W.R.1    Johnson, D.C.2
  • 4
    • 0028279448 scopus 로고
    • Maximizing signal-to-noise ratio in direct current and pulsed amperometric detection
    • Rocklin RD, Tullsen TR, Marucco MG. Maximizing signal-to-noise ratio in direct current and pulsed amperometric detection. J. Chromatogr. A. 1994;671(1-):109-114.
    • (1994) J. Chromatogr. A , vol.671 , Issue.1 , pp. 109-114
    • Rocklin, R.D.1    Tullsen, T.R.2    Marucco, M.G.3
  • 5
    • 0000554685 scopus 로고    scopus 로고
    • Improved long-term reproducibility for pulsed amperometric detection of carbohydrates via a new quadruple-potential waveform
    • Rocklin RD, Clarke AP, Weitzhandler M. Improved long-term reproducibility for pulsed amperometric detection of carbohydrates via a new quadruple-potential waveform. Anal. Chem. 1998;70:1496-1501.
    • (1998) Anal. Chem. , vol.70 , pp. 1496-1501
    • Rocklin, R.D.1    Clarke, A.P.2    Weitzhandler, M.3
  • 6
    • 0034475474 scopus 로고    scopus 로고
    • Electrospray mass spectrometry and fragmentation of N-linked carbohydrates derivatized at the reducing terminus
    • Harvey DJ. Electrospray mass spectrometry and fragmentation of N-linked carbohydrates derivatized at the reducing terminus. J. Am. Soc. Mass Spectrom. 2000;11(10):900-915.
    • (2000) J. Am. Soc. Mass Spectrom , vol.11 , Issue.10 , pp. 900-915
    • Harvey, D.J.1
  • 7
    • 1242272032 scopus 로고    scopus 로고
    • New fragmentation mechanisms in matrix-assisted laser desorption/ionization time-of-flight/time-of-flight tandem mass spectrometry of carbohydrates.
    • Spina E, Sturiale L, Romeo D, Impallomeni G, Garozzo D, Waidelich D, Glueckmann M. New fragmentation mechanisms in matrix-assisted laser desorption/ionization time-of-flight/time-of-flight tandem mass spectrometry of carbohydrates. Mass Spectrom. 2004;18(4):392-398.
    • (2004) Mass Spectrom. , vol.18 , Issue.4 , pp. 392-398
    • Spina, E.1    Sturiale, L.2    Romeo, D.3    Impallomeni, G.4    Garozzo, D.5    Waidelich, D.6    Glueckmann, M.7
  • 8
    • 0032531611 scopus 로고    scopus 로고
    • Electrospray ionization-ion trap mass spectrometry for structural analysis of complex N-linked glycoprotein oligosaccharides.
    • Weiskopf AS, Vouros P, Harvey DJ. Electrospray ionization-ion trap mass spectrometry for structural analysis of complex N-linked glycoprotein oligosaccharides. Anal. Chem. 1998;70(20):4441-4447.
    • (1998) Anal. Chem. , vol.70 , Issue.20 , pp. 4441-4447
    • Weiskopf, A.S.1    Vouros, P.2    Harvey, D.J.3
  • 9
    • 0031946618 scopus 로고    scopus 로고
    • Recent progress in high-performance anion-exchange chromatography/ ionspray mass spectrometry for molecular mass determination and characterization of carbohydrates using static and scanning array detection
    • van der Hoeven RAM, Tjaden UR, van der Greef J, van Casteren WHM, Schols HA, Voragen AGJ, Bruggink C. Recent progress in high-performance anion-exchange chromatography/ ionspray mass spectrometry for molecular mass determination and characterization of carbohydrates using static and scanning array detection. J.Mass Spectrom. 1998;33(4):377-386.
    • (1998) J.Mass Spectrom , vol.33 , Issue.4 , pp. 377-386
    • van der Hoeven, R.A.M.1    Tjaden, U.R.2    van der Greef, J.3    van Casteren, W.H.M.4    Schols, H.A.5    Voragen, A.G.J.6    Bruggink, C.7
  • 10
    • 77954362730 scopus 로고    scopus 로고
    • Glycan profiling of urine, amniotic fluid and ascitic fluid from galactosialidosis patients reveals novel oligosaccharides with reducing end hexose and aldohexonic acid residues
    • Bruggink C, Poorthuis BJHM, Piraud M, Froissart R, Deelder AM, Wuhrer M. Glycan profiling of urine, amniotic fluid and ascitic fluid from galactosialidosis patients reveals novel oligosaccharides with reducing end hexose and aldohexonic acid residues. FEBS J. 2010;277:2970-2986.
    • (2010) FEBS J , vol.277 , pp. 2970-2986
    • Bruggink, C.1    Poorthuis, B.J.H.M.2    Piraud, M.3    Froissart, R.4    Deelder, A.M.5    Wuhrer, M.6
  • 11
    • 0004244370 scopus 로고    scopus 로고
    • 3rd ed. Weinheim (Germany): VCH Verlag
    • Weiss J. Ion Chromatography, 3rd ed. Weinheim (Germany): VCH Verlag;2004.
    • (2004) Ion Chromatography
    • Weiss, J.1
  • 12
    • 0342976375 scopus 로고
    • Separation of positional isomers of oligosaccharides and glycopeptides by high-performance anion-exchange chromatography with pulsed amperometric detection.
    • Hardy MR, Townsend RR. Separation of positional isomers of oligosaccharides and glycopeptides by high-performance anion-exchange chromatography with pulsed amperometric detection. Proc. Natl. Acad. Sci. U.S.A. 1988;85(10):3289-3293.
    • (1988) Proc. Natl. Acad. Sci. U.S.A. , vol.85 , Issue.10 , pp. 3289-3293
    • Hardy, M.R.1    Townsend, R.R.2
  • 13
    • 0034568463 scopus 로고    scopus 로고
    • Carbohydrate analysis by high-performance anion-exchange chromatography with pulsed amperometric detection: The potential is still growing
    • Cataldi TR, Campa C, De Benedetto GE. Carbohydrate analysis by high-performance anion-exchange chromatography with pulsed amperometric detection: The potential is still growing. Fresenius. J. Anal. Chem. 2000;368(8):739-758.
    • (2000) Fresenius. J. Anal. Chem , vol.368 , Issue.8 , pp. 739-758
    • Cataldi, T.R.1    Campa, C.2    De Benedetto, G.E.3
  • 15
    • 32644474401 scopus 로고    scopus 로고
    • Advances in fluorescence derivatization methods for high-performance liquid chromatographic analysis of glycoprotein carbohydrates
    • Anumula KR. Advances in fluorescence derivatization methods for high-performance liquid chromatographic analysis of glycoprotein carbohydrates. Anal. Biochem. 2006;350(1):1-23.
    • (2006) Anal. Biochem , vol.350 , Issue.1 , pp. 1-23
    • Anumula, K.R.1
  • 16
    • 0029175060 scopus 로고
    • Matrix-assisted laser desorption/ionization mass spectrometry: Improved matrix for oligosaccharides
    • Mohr MD, Bornsen KO, Widmer HM. Matrix-assisted laser desorption/ionization mass spectrometry: Improved matrix for oligosaccharides. Mass Spectrom. 1995;9(9):809-814.
    • (1995) Mass Spectrom , vol.9 , Issue.9 , pp. 809-814
    • Mohr, M.D.1    Bornsen, K.O.2    Widmer, H.M.3
  • 17
    • 0032519943 scopus 로고    scopus 로고
    • Improvements to in-line desalting of oligosaccharides separated by high-pH anion exchange chromatography with pulsed amperometric detection.
    • Thayer JR, Rohrer JS, Avdalovic N, Gearing RP. Improvements to in-line desalting of oligosaccharides separated by high-pH anion exchange chromatography with pulsed amperometric detection. Anal. Biochem. 1998;256(2):207-216.
    • (1998) Anal. Biochem. , vol.256 , Issue.2 , pp. 207-216
    • Thayer, J.R.1    Rohrer, J.S.2    Avdalovic, N.3    Gearing, R.P.4
  • 18
    • 22244446150 scopus 로고    scopus 로고
    • Analysis of carbohydrates by anion exchange chromatography and mass spectrometry.
    • Bruggink C, Maurer R, Herrmann H, Cavalli S, Hoefler F. Analysis of carbohydrates by anion exchange chromatography and mass spectrometry. J. Chromatogr. A. 2005;1085(1):104-109.
    • (2005) J. Chromatogr. A. , vol.1085 , Issue.1 , pp. 104-109
    • Bruggink, C.1    Maurer, R.2    Herrmann, H.3    Cavalli, S.4    Hoefler, F.5
  • 19
    • 0030180868 scopus 로고    scopus 로고
    • Collision-induced dissociation of branched oligosaccharide ions with analysis and calculation of relative dissociation thresholds.
    • Penn SG, Cancilla MT, Lebrilla CB. Collision-induced dissociation of branched oligosaccharide ions with analysis and calculation of relative dissociation thresholds. Anal. Chem. 1996;68(14):2331-2339.
    • (1996) Anal. Chem. , vol.68 , Issue.14 , pp. 2331-2339
    • Penn, S.G.1    Cancilla, M.T.2    Lebrilla, C.B.3
  • 20
    • 0030934998 scopus 로고    scopus 로고
    • Cationization processes in matrix-assisted laser desorption/ionization mass spectrometry: Attachment of divalent and trivalent metal ions
    • Wong CKL, Chan T-W. Cationization processes in matrix-assisted laser desorption/ionization mass spectrometry: Attachment of divalent and trivalent metal ions. Mass Spectrom. 1997;11:513-519.
    • (1997) Mass Spectrom , vol.11 , pp. 513-519
    • Wong, C.K.L.1    Chan, T.-W.2
  • 21
    • 0036208688 scopus 로고    scopus 로고
    • Evidence for long-range glycosyl transfer reactions in the gas phase
    • Franz AH, Lebrilla CB. Evidence for long-range glycosyl transfer reactions in the gas phase. J. Am. Soc. Mass Spectrom. 2002;13(4):325-337.
    • (2002) J. Am. Soc. Mass Spectrom , vol.13 , Issue.4 , pp. 325-337
    • Franz, A.H.1    Lebrilla, C.B.2
  • 22
    • 0037084078 scopus 로고    scopus 로고
    • "Internal residue loss": Rearrangements occurring during the fragmentation of carbohydrates derivatized at the reducing terminus
    • Harvey DJ, Mattu TS, Wormald MR, Royle L, Dwek RA, Rudd PM. "Internal residue loss": Rearrangements occurring during the fragmentation of carbohydrates derivatized at the reducing terminus. Anal. Chem. 2002;74(4):734-740.
    • (2002) Anal. Chem. , vol.74 , Issue.4 , pp. 734-740
    • Harvey, D.J.1    Mattu, T.S.2    Wormald, M.R.3    Royle, L.4    Dwek, R.A.5    Rudd, P.M.6
  • 23
    • 0024206786 scopus 로고
    • A systematic nomenclature for carbohydrate fragmentation in FAB-MS/MS spectra of glycoconjugates
    • Domon B, Costello CE. A systematic nomenclature for carbohydrate fragmentation in FAB-MS/MS spectra of glycoconjugates. J. Glycoconj. 1988;5:397-409.
    • (1988) J. Glycoconj , vol.5 , pp. 397-409
    • Domon, B.1    Costello, C.E.2
  • 24
    • 0025057153 scopus 로고
    • Analysis of glycoprotein-derived oligosaccharides by high-pH anion-exchange chromatography
    • Basa LJ, Spellman MW. Analysis of glycoprotein-derived oligosaccharides by high-pH anion-exchange chromatography. J. Chromatogr. 1990;499:205-220.
    • (1990) J. Chromatogr. , vol.499 , pp. 205-220
    • Basa, L.J.1    Spellman, M.W.2
  • 25
    • 0024970568 scopus 로고
    • Liquid ion-exchange chromatography under pressure of milk oligosaccharides using a pulsed amperometric detector
    • Wang WT, Zopf D. Liquid ion-exchange chromatography under pressure of milk oligosaccharides using a pulsed amperometric detector. Carbohydr. Res. 1989;189:1-11.
    • (1989) Carbohydr. Res. , vol.189 , pp. 1-11
    • Wang, W.T.1    Zopf, D.2
  • 26
    • 0024677135 scopus 로고
    • Separation of fucosylated oligosaccharides using high-pH anion-exchange chromatography with pulsed-amperometric detection
    • Hardy MR, Townsend RR. Separation of fucosylated oligosaccharides using high-pH anion-exchange chromatography with pulsed-amperometric detection. Carbohydr. Res. 1989;188:1-7.
    • (1989) Carbohydr. Res. , vol.188 , pp. 1-7
    • Hardy, M.R.1    Townsend, R.R.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.