메뉴 건너뛰기




Volumn , Issue , 2012, Pages 339-350

Monosaccharide Analysis of Glycoproteins by High-Performance Anion-Exchange Chromatography with Pulsed Amperometric Detection

Author keywords

Glycoproteins; HPAEC PAD analysis; HPAEC PAD monosaccharide

Indexed keywords


EID: 84886015601     PISSN: None     EISSN: None     Source Type: Book    
DOI: 10.1002/9781118147009.ch18     Document Type: Chapter
Times cited : (7)

References (36)
  • 1
    • 0020667135 scopus 로고
    • Determination of carbohydrates by anion exchange chromatography with pulsed amperometric detection
    • Rocklin RD, Pohl CA. Determination of carbohydrates by anion exchange chromatography with pulsed amperometric detection. J. Liq. Chromatogr. 1983;6:1577-1590.
    • (1983) J. Liq. Chromatogr. , vol.6 , pp. 1577-1590
    • Rocklin, R.D.1    Pohl, C.A.2
  • 2
    • 0023877998 scopus 로고
    • Monosaccharide analysis of glycoconjugates by anion exchange chromatography with pulsed amperometric detection
    • Hardy MR, Townsend RR, Lee, YC. Monosaccharide analysis of glycoconjugates by anion exchange chromatography with pulsed amperometric detection. Anal. Biochem. 1988;170:54-62.
    • (1988) Anal. Biochem. , vol.170 , pp. 54-62
    • Hardy, M.R.1    Townsend, R.R.2    Lee, Y.C.3
  • 3
    • 84886002031 scopus 로고    scopus 로고
    • Monitoring protein N-glycosylation consistency using HPAEC-PAD
    • In: Bhattacharyya, L and Rohrer, JS, editors. Applications of ion chromatography for pharmaceutical and biological products New Jersey: John Wiley & Sons
    • Grey C. Monitoring protein N-glycosylation consistency using HPAEC-PAD. In: Bhattacharyya, L and Rohrer, JS, editors. Applications of ion chromatography for pharmaceutical and biological products. New Jersey: John Wiley & Sons; 2012.
    • (2012)
    • Grey, C.1
  • 4
    • 84886029186 scopus 로고    scopus 로고
    • Oligosaccharide analysis by high-performance anion-exchange chromatography hyphenated to integrated pulsed amperometric detection and on-line ion-trap mass spectrometry
    • In: Bhattacharyya, L and Rohrer, JS, editors. Applications of ion chromatography for pharmaceutical and biological products New Jersey: John Wiley & Sons
    • Bruggink C. Oligosaccharide analysis by high-performance anion-exchange chromatography hyphenated to integrated pulsed amperometric detection and on-line ion-trap mass spectrometry. In: Bhattacharyya, L and Rohrer, JS, editors. Applications of ion chromatography for pharmaceutical and biological products. New Jersey: John Wiley & Sons; 2012.
    • (2012)
    • Bruggink, C.1
  • 5
    • 84885964448 scopus 로고    scopus 로고
    • High performance anion-exchange chromatography with pulsed amperometric detection (HPAEC-PAD) analysis of GBS glycoconjugate vaccines: from fermentation to final product
    • In: Bhattacharyya, L and Rohrer, JS, editors. Application of ions chromatography for pharmaceutical and biological products New Jersey: John Wiley & Sons
    • Ricci S, Fabbri B, Giannini S, Bernardini S, Morelli M. High performance anion-exchange chromatography with pulsed amperometric detection (HPAEC-PAD) analysis of GBS glycoconjugate vaccines: from fermentation to final product. In: Bhattacharyya, L and Rohrer, JS, editors. Application of ions chromatography for pharmaceutical and biological products. New Jersey: John Wiley & Sons; 2012.
    • (2012)
    • Ricci, S.1    Fabbri, B.2    Giannini, S.3    Bernardini, S.4    Morelli, M.5
  • 6
    • 84886010491 scopus 로고    scopus 로고
    • Stability studies and characterization of meningococcal A, C, Y, and W135 glycoconjugate vaccine
    • In: Bhattacharyya, L and Rohrer, JS, editors. Applications of ion chromatography for pharmaceutical and biological products New Jersey: John Wiley & Sons
    • Carinci V, Bernardini A, Campa C, Magagnoli C, Beccai F, D'scenzi S. Stability studies and characterization of meningococcal A, C, Y, and W135 glycoconjugate vaccine. In: Bhattacharyya, L and Rohrer, JS, editors. Applications of ion chromatography for pharmaceutical and biological products. New Jersey: John Wiley & Sons; 2012.
    • (2012)
    • Carinci, V.1    Bernardini, A.2    Campa, C.3    Magagnoli, C.4    Beccai, F.5    D'scenzi, S.6
  • 7
    • 84886006818 scopus 로고    scopus 로고
    • Applications of ion chromatography in biological product analyses
    • In: Bhattacharyya, L and Rohrer, JS, editors. Applications of ion chromatography for pharmaceutical and biological products New Jersey: John Wiley & Sons
    • Del Grosso AV, Duong B. Applications of ion chromatography in biological product analyses. In: Bhattacharyya, L and Rohrer, JS, editors. Applications of ion chromatography for pharmaceutical and biological products. New Jersey: John Wiley & Sons; 2012.
    • (2012)
    • Del Grosso, A.V.1    Duong, B.2
  • 8
    • 84885969681 scopus 로고    scopus 로고
    • Ion chromatography analysis of aminoglycoside antibiotics
    • In: Bhattacharyya, L and Rohrer, JS, editors. Applications of ion chromatography for pharmaceutical and biological products New Jersey: John Wiley & Sons
    • Hanko VP, Rohrer JS. Ion chromatography analysis of aminoglycoside antibiotics. In: Bhattacharyya, L and Rohrer, JS, editors. Applications of ion chromatography for pharmaceutical and biological products. New Jersey: John Wiley & Sons; 2012.
    • (2012)
    • Hanko, V.P.1    Rohrer, J.S.2
  • 9
    • 84885981265 scopus 로고    scopus 로고
    • Ion chromatographic analysis of pharmaceuticals for authenticity and adulteration
    • In: Bhattacharyya, L and Rohrer, JS, editors. Applications of ion chromatography for pharmaceutical and biological products New Jersey: John Wiley & Sons
    • Jackson DS. Ion chromatographic analysis of pharmaceuticals for authenticity and adulteration. In: Bhattacharyya, L and Rohrer, JS, editors. Applications of ion chromatography for pharmaceutical and biological products. New Jersey: John Wiley & Sons; 2012.
    • (2012)
    • Jackson, D.S.1
  • 10
    • 84886047257 scopus 로고    scopus 로고
    • Validation of ion chromatographic methods
    • In: Bhattacharyya, L and Rohrer, JS, editors. Applications of ion chromatography for pharmaceutical and biological products New Jersey: John Wiley & Sons
    • Karmarkar SV. Validation of ion chromatographic methods. In: Bhattacharyya, L and Rohrer, JS, editors. Applications of ion chromatography for pharmaceutical and biological products. New Jersey: John Wiley & Sons; 2012.
    • (2012)
    • Karmarkar, S.V.1
  • 11
    • 84886055782 scopus 로고    scopus 로고
    • Glycan analysis by high performance anion exchange chromatography with pulsed amperometric detection
    • In: Bhattacharyya, L and Rohrer, JS, editors. Applications of ion chromatography for pharmaceutical and biological products. New Jersey: John Wiley & Sons
    • Bhattacharyya L. Glycan analysis by high performance anion exchange chromatography with pulsed amperometric detection. In: Bhattacharyya, L and Rohrer, JS, editors. Applications of ion chromatography for pharmaceutical and biological products. New Jersey: John Wiley & Sons; 2012.
    • (2012)
    • Bhattacharyya, L.1
  • 12
    • 0026204945 scopus 로고
    • High-performance anion-exchange chromatography of sugars and sugar alcohols on quaternary ammonium resins under alkaline conditions
    • Paskach TJ, Lieker HP, Reilly PJ, Thielecke, K. High-performance anion-exchange chromatography of sugars and sugar alcohols on quaternary ammonium resins under alkaline conditions. Carbohydr. Res. 1991;215:1-14.
    • (1991) Carbohydr. Res. , vol.215 , pp. 1-14
    • Paskach, T.J.1    Lieker, H.P.2    Reilly, P.J.3    Thielecke, K.4
  • 13
    • 0038801569 scopus 로고
    • Secondary isotope effect: The resolution of deuterated glucoses by anion-exchange chromatography
    • Rohrer JS, Olechno JD. Secondary isotope effect: The resolution of deuterated glucoses by anion-exchange chromatography. Anal. Chem. 1992;64:914-916.
    • (1992) Anal. Chem. , vol.64 , pp. 914-916
    • Rohrer, J.S.1    Olechno, J.D.2
  • 14
    • 0026566429 scopus 로고
    • Analyses of isomeric mono-O-methyl-D-glucoses, D-glucobioses and D-glucose monophosphates by high-performance anion-exchange chromatography with pulsed amperometric detection
    • Koizumi K, Kubota Y, Ozaki H, Shigenobu K, Fukuda M, Tanimoto T. Analyses of isomeric mono-O-methyl-D-glucoses, D-glucobioses and D-glucose monophosphates by high-performance anion-exchange chromatography with pulsed amperometric detection. J. Chromatogr. 1992;595:340-345.
    • (1992) J. Chromatogr. , vol.595 , pp. 340-345
    • Koizumi, K.1    Kubota, Y.2    Ozaki, H.3    Shigenobu, K.4    Fukuda, M.5    Tanimoto, T.6
  • 15
    • 0029957519 scopus 로고    scopus 로고
    • The study of the relationship between retention and structure on D-mannose and its derivatives with high-performance anion-exchange chromatography
    • Li S, Mou S, Liao W, Lu D. The study of the relationship between retention and structure on D-mannose and its derivatives with high-performance anion-exchange chromatography. Carbohydr. Res. 1996;295:229-234.
    • (1996) Carbohydr. Res. , vol.295 , pp. 229-234
    • Li, S.1    Mou, S.2    Liao, W.3    Lu, D.4
  • 16
    • 0025006627 scopus 로고
    • High-performance anion-exchange chromatography for carbohydrate analysis
    • Lee YC. High-performance anion-exchange chromatography for carbohydrate analysis. Anal. Biochem. 1990;189:151-162.
    • (1990) Anal. Biochem. , vol.189 , pp. 151-162
    • Lee, Y.C.1
  • 17
    • 0027427607 scopus 로고
    • Evidence for the presence of multiple capsules in Vibrio vulnificus Strain B062316
    • Reddy GP, Hayat U, Bush CA, Morris JG Jr. Evidence for the presence of multiple capsules in Vibrio vulnificus Strain B062316. Anal. Biochem. 1993;214:106-115.
    • (1993) Anal. Biochem. , vol.214 , pp. 106-115
    • Reddy, G.P.1    Hayat, U.2    Bush, C.A.3    Jr.Morris, J.G.4
  • 18
    • 0025944050 scopus 로고
    • The compositional analysis of bacterial extracellular polysaccharides by high-performance anion-exchange chromatography
    • Clarke AJ, Sarabia V, Keenleyside W, MacLachlan PR, Whitfield C. The compositional analysis of bacterial extracellular polysaccharides by high-performance anion-exchange chromatography. Anal. Biochem. 1991;199:68-74.
    • (1991) Anal. Biochem. , vol.199 , pp. 68-74
    • Clarke, A.J.1    Sarabia, V.2    Keenleyside, W.3    MacLachlan, P.R.4    Whitfield, C.5
  • 19
    • 0026598616 scopus 로고
    • Carbohydrate Compositional Analysis of bacterial polysaccharides: Optimized acid hydrolysis conditions for HPAEC-PAD analysis
    • Ip CCY, Manam V, Hepler R, Hennessey Jr JP. Carbohydrate Compositional Analysis of bacterial polysaccharides: Optimized acid hydrolysis conditions for HPAEC-PAD analysis. Anal. Biochem. 1992;201:343-349.
    • (1992) Anal. Biochem. , vol.201 , pp. 343-349
    • Ip, C.C.Y.1    Manam, V.2    Hepler, R.3    Jr.Hennessey, J.P.4
  • 20
    • 0027293346 scopus 로고
    • Compositional analysis of peptidoglycan by high-performance anion-exchange chromatography
    • Clarke AJ. Compositional analysis of peptidoglycan by high-performance anion-exchange chromatography. Anal. Biochem. 1993;212:344-350.
    • (1993) Anal. Biochem. , vol.212 , pp. 344-350
    • Clarke, A.J.1
  • 21
    • 84886074617 scopus 로고    scopus 로고
    • Pulsed electrochemical detection in ion chromatography
    • In: Bhattacharyya, L and Rohrer, JS, editors. Applications of ion chromatography for pharmaceutical and biological products. New Jersey: John Wiley & Sons
    • LaCourse WR. Pulsed electrochemical detection in ion chromatography. In: Bhattacharyya, L and Rohrer, JS, editors. Applications of ion chromatography for pharmaceutical and biological products. New Jersey: John Wiley & Sons; 2012.
    • (2012)
    • LaCourse, W.R.1
  • 22
    • 0040407133 scopus 로고
    • Determination of aminosaccharides by highperformance anion-exchange chromatography with pulsed amperometric detection
    • Martens DA, Frankenberger WT Jr. Determination of aminosaccharides by highperformance anion-exchange chromatography with pulsed amperometric detection. Talanta 1991;38:245-251.
    • (1991) Talanta , vol.38 , pp. 245-251
    • Martens, D.A.1    Jr.Frankenberger, W.T.2
  • 23
    • 0028263803 scopus 로고
    • Comparison of acid hydrolytic conditions for Asn-linked oligosaccharides
    • Fan JQ, Namiki Y, Matsuoka K, Lee YC. Comparison of acid hydrolytic conditions for Asn-linked oligosaccharides. Anal. Biochem. 1994;219: 385-378.
    • (1994) Anal. Biochem. , vol.219 , pp. 385-378
    • Fan, J.Q.1    Namiki, Y.2    Matsuoka, K.3    Lee, Y.C.4
  • 24
    • 84886071686 scopus 로고    scopus 로고
    • Dionex Corporation
    • Technical Note 53: Determination of glycoprotein monosaccharide composition by HPAE-PAD using online electrolytically generated eluents
    • Dionex Corporation, Technical Note 53: Determination of glycoprotein monosaccharide composition by HPAE-PAD using online electrolytically generated eluents.
  • 25
    • 84886071686 scopus 로고    scopus 로고
    • Dionex Corporation
    • Product Manual for CarboPac MA1, PA1, P10, PA100
    • Dionex Corporation, Product Manual for CarboPac MA1, PA1, P10, PA100, p. 9.
  • 26
    • 84886071686 scopus 로고    scopus 로고
    • Dionex Corporation
    • Technical Note 40: Glycoprotein monosaccharide analysis using highperformance anion-exchange chromatography with pulsed amperometric detection (HPAEPAD)
    • Dionex Corporation, Technical Note 40: Glycoprotein monosaccharide analysis using highperformance anion-exchange chromatography with pulsed amperometric detection (HPAEPAD).
  • 27
    • 84886071686 scopus 로고    scopus 로고
    • Dionex Corporation
    • Technical Note 71: Eluent preparation for high-performance anionexchange chromatography with pulsed amperometric detection
    • Dionex Corporation, Technical Note 71: Eluent preparation for high-performance anionexchange chromatography with pulsed amperometric detection.
  • 28
    • 0030271398 scopus 로고    scopus 로고
    • Eliminating amino acid and peptide interference in high-performance anion-exchange chromatography with pulsed amperometric detection glycoprotein monosaccharide analysis
    • Weitzhandler M, Pohl C, Rohrer J, Narayanan L, Slingsby R, Narayanan L, Avdalovic N. Eliminating amino acid and peptide interference in high-performance anion-exchange chromatography with pulsed amperometric detection glycoprotein monosaccharide analysis. Anal. Biochem. 1996;241:135-136.
    • (1996) Anal. Biochem. , vol.241 , pp. 135-136
    • Weitzhandler, M.1    Pohl, C.2    Rohrer, J.3    Narayanan, L.4    Slingsby, R.5    Narayanan, L.6    Avdalovic, N.7
  • 29
    • 0027165850 scopus 로고
    • Identification, quantification, and characterization of glycopeptides in reversed-phase HPLC separations of glycoprotein proteolytic digests
    • Rohrer JS, Cooper GA, Townsend RR. Identification, quantification, and characterization of glycopeptides in reversed-phase HPLC separations of glycoprotein proteolytic digests. Anal. Biochem. 1993;212:7-16.
    • (1993) Anal. Biochem. , vol.212 , pp. 7-16
    • Rohrer, J.S.1    Cooper, G.A.2    Townsend, R.R.3
  • 30
    • 0000554685 scopus 로고    scopus 로고
    • Improved Long-term reproducibility for pulsed amperometric detection of carbohydrates via a new quadruple-potential waveform
    • Rocklin RD, Clarke AP, Weitzhandler M. Improved Long-term reproducibility for pulsed amperometric detection of carbohydrates via a new quadruple-potential waveform. Anal. Chem. 1998;70:1496-1501.
    • (1998) Anal. Chem. , vol.70 , pp. 1496-1501
    • Rocklin, R.D.1    Clarke, A.P.2    Weitzhandler, M.3
  • 31
    • 0037317383 scopus 로고    scopus 로고
    • Development and characterization of microfabricated disposable gold working electrodes for high-performance ion-exchange chromatography and integrated pulsed amperometric detection
    • Cheng J, Jandik P, Avdalovic N. Development and characterization of microfabricated disposable gold working electrodes for high-performance ion-exchange chromatography and integrated pulsed amperometric detection. Anal. Chem. 2003;75:572-579.
    • (2003) Anal. Chem. , vol.75 , pp. 572-579
    • Cheng, J.1    Jandik, P.2    Avdalovic, N.3
  • 32
    • 0028325772 scopus 로고
    • High-pH anion-exchange chromatography of glycoproteinderived carbohydrates
    • In: Lennarz, WJ, Hart, GW, editors. Methods of Enzymology Guide to Techniques in Glycobiology
    • Hardy MR, Townsend RR. High-pH anion-exchange chromatography of glycoproteinderived carbohydrates. In: Lennarz, WJ, Hart, GW, editors. Methods of Enzymology Guide to Techniques in Glycobiology, Vol. 230. San Diego: Academic Press; 1994. p 208-225.
    • (1994) San Diego: Academic Press , vol.230 , pp. 208-225
    • Hardy, M.R.1    Townsend, R.R.2
  • 33
    • 0025106407 scopus 로고
    • Carbohydrate characterization of recombinant glycoproteins of pharmaceutical interest
    • Spellman MW. Carbohydrate characterization of recombinant glycoproteins of pharmaceutical interest. Anal. Chem. 1990;62:1714-1722.
    • (1990) Anal. Chem. , vol.62 , pp. 1714-1722
    • Spellman, M.W.1
  • 34
    • 77949266037 scopus 로고    scopus 로고
    • Carbohydrate analysis throughout the development of a protein therapeutic
    • Higgins E. Carbohydrate analysis throughout the development of a protein therapeutic. Glycoconjugate. J. 2010;27:211-225.
    • (2010) Glycoconjugate. J. , vol.27 , pp. 211-225
    • Higgins, E.1
  • 35
    • 0004125932 scopus 로고    scopus 로고
    • Points to consider in the manufacture and testing of monoclonal antibody products for human use
    • FDA CBER document UCM153152.pdf, (Accessed 10/27/11)
    • Zoon K. Points to consider in the manufacture and testing of monoclonal antibody products for human use. FDA CBER document UCM153152.pdf. 1997. Available at, http://www.fda.gov/downloads/BiologicsBloodVaccines/GuidanceComplianceRegulatoryInformation/OtherRecommendationsforManufacturers/UCM153182.pdf (Accessed 10/27/11).
    • (1997)
    • Zoon, K.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.