메뉴 건너뛰기




Volumn 23, Issue 11, 2013, Pages 3087-3093

Contrast-enhanced free-breathing 3D T1-weighted gradient-echo sequence for hepatobiliary MRI in patients with breath-holding difficulties

Author keywords

Image quality; Liver; Magnetic resonance imaging; Radial acquisition; T1 weighted free breathing GRE sequence

Indexed keywords

GADOXETIC ACID;

EID: 84885955619     PISSN: 09387994     EISSN: 14321084     Source Type: Journal    
DOI: 10.1007/s00330-013-2910-2     Document Type: Article
Times cited : (38)

References (25)
  • 1
    • 0021235596 scopus 로고
    • The effect of motion on two-dimensional fourier transformation magnetic resonance images
    • 6729101 1:STN:280:DyaL2c3it1Krug%3D%3D
    • Schultz CL, Alfidi RJ, Nelson AD, Kopiwoda SY, Clampitt ME (1984) The effect of motion on two-dimensional fourier transformation magnetic resonance images. Radiology 152:117-121
    • (1984) Radiology , vol.152 , pp. 117-121
    • Schultz, C.L.1    Alfidi, R.J.2    Nelson, A.D.3    Kopiwoda, S.Y.4    Clampitt, M.E.5
  • 2
    • 1642580581 scopus 로고    scopus 로고
    • Shortening MR image acquisition time for volumetric interpolated breath-hold examination with a recently developed parallel imaging reconstruction technique: Clinical feasibility
    • 14699184 10.1148/radiol.2302021230
    • McKenzie CA, Lim D, Ransil BJ et al (2004) Shortening MR image acquisition time for volumetric interpolated breath-hold examination with a recently developed parallel imaging reconstruction technique: Clinical feasibility. Radiology 230:589-594
    • (2004) Radiology , vol.230 , pp. 589-594
    • McKenzie, C.A.1    Lim, D.2    Ransil, B.J.3
  • 3
    • 15944423506 scopus 로고    scopus 로고
    • Parallel acquisition techniques for accelerated volumetric interpolated breath-hold examination magnetic resonance imaging of the upper abdomen: Assessment of image quality and lesion conspicuity
    • 15779026 10.1002/jmri.20288
    • Vogt FM, Antoch G, Hunold P et al (2005) Parallel acquisition techniques for accelerated volumetric interpolated breath-hold examination magnetic resonance imaging of the upper abdomen: Assessment of image quality and lesion conspicuity. J Magn Reson Imaging 21:376-382
    • (2005) J Magn Reson Imaging , vol.21 , pp. 376-382
    • Vogt, F.M.1    Antoch, G.2    Hunold, P.3
  • 4
    • 17844396526 scopus 로고    scopus 로고
    • Magnetic resonance imaging of the upper abdomen using a free-breathing T2-weighted turbo spin echo sequence with navigator triggered prospective acquisition correction
    • 15834908 10.1002/jmri.20293
    • Klessen C, Asbach P, Kroencke TJ et al (2005) Magnetic resonance imaging of the upper abdomen using a free-breathing T2-weighted turbo spin echo sequence with navigator triggered prospective acquisition correction. J Magn Reson Imaging 21:576-582
    • (2005) J Magn Reson Imaging , vol.21 , pp. 576-582
    • Klessen, C.1    Asbach, P.2    Kroencke, T.J.3
  • 5
    • 34547897640 scopus 로고    scopus 로고
    • Image quality and focal lesion detection on T2-weighted MR imaging of the liver: Comparison of two high-resolution free-breathing imaging techniques with two breath-hold imaging techniques
    • 17610287 10.1002/jmri.21002
    • Lee SS, Byun JH, Hong HS et al (2007) Image quality and focal lesion detection on T2-weighted MR imaging of the liver: Comparison of two high-resolution free-breathing imaging techniques with two breath-hold imaging techniques. J Magn Reson Imaging 26:323-330
    • (2007) J Magn Reson Imaging , vol.26 , pp. 323-330
    • Lee, S.S.1    Byun, J.H.2    Hong, H.S.3
  • 6
    • 77956802861 scopus 로고    scopus 로고
    • Respiratory navigated free breathing 3D spoiled gradient-recalled echo sequence for contrast-enhanced examination of the liver: Diagnostic utility and comparison with free breathing and breath-hold conventional examinations
    • 20729447 10.2214/AJR.09.3892
    • Young PM, Brau AC, Iwadate Y et al (2010) Respiratory navigated free breathing 3D spoiled gradient-recalled echo sequence for contrast-enhanced examination of the liver: Diagnostic utility and comparison with free breathing and breath-hold conventional examinations. AJR Am J Roentgenol 195:687-691
    • (2010) AJR Am J Roentgenol , vol.195 , pp. 687-691
    • Young, P.M.1    Brau, A.C.2    Iwadate, Y.3
  • 7
    • 0032754594 scopus 로고    scopus 로고
    • Motion correction with PROPELLER MRI: Application to head motion and free-breathing cardiac imaging
    • 10542356 10.1002/(SICI)1522-2594(199911)42:5<963: AID-MRM17>3.0. CO;2-L 1:STN:280:DC%2BD3c%2FhtFCqsg%3D%3D
    • Pipe JG (1999) Motion correction with PROPELLER MRI: Application to head motion and free-breathing cardiac imaging. Magn Reson Med 42:963-969
    • (1999) Magn Reson Med , vol.42 , pp. 963-969
    • Pipe, J.G.1
  • 8
    • 80052466239 scopus 로고    scopus 로고
    • Free-breathing radial 3D fat-suppressed T1-weighted gradient echo sequence: A viable alternative for contrast-enhanced liver imaging in patients unable to suspend respiration
    • 21577119 10.1097/RLI.0b013e31821eea45
    • Chandarana H, Block TK, Rosenkrantz AB et al (2011) Free-breathing radial 3D fat-suppressed T1-weighted gradient echo sequence: A viable alternative for contrast-enhanced liver imaging in patients unable to suspend respiration. Invest Radiol 46:648-653
    • (2011) Invest Radiol , vol.46 , pp. 648-653
    • Chandarana, H.1    Block, T.K.2    Rosenkrantz, A.B.3
  • 9
    • 80052191686 scopus 로고    scopus 로고
    • Free-breathing 3D T1-weighted gradient-echo sequence with radial data sampling in abdominal MRI: Preliminary observations
    • 21862807 10.2214/AJR.10.5881
    • Azevedo RM, de Campos RO, Ramalho M, Heredia V, Dale BM, Semelka RC (2011) Free-breathing 3D T1-weighted gradient-echo sequence with radial data sampling in abdominal MRI: Preliminary observations. AJR Am J Roentgenol 197:650-657
    • (2011) AJR Am J Roentgenol , vol.197 , pp. 650-657
    • Azevedo, R.M.1    De Campos, R.O.2    Ramalho, M.3    Heredia, V.4    Dale, B.M.5    Semelka, R.C.6
  • 10
    • 0033646318 scopus 로고    scopus 로고
    • K-space weighted image contrast (KWIC) for contrast manipulation in projection reconstruction MRI
    • 11108618 10.1002/1522-2594(200012)44:6<825: AID-MRM2>3.0.CO;2-D 1:STN:280:DC%2BD3M%2FotlWitg%3D%3D
    • Song HK, Dougherty L (2000) k-space weighted image contrast (KWIC) for contrast manipulation in projection reconstruction MRI. Magn Reson Med 44:825-832
    • (2000) Magn Reson Med , vol.44 , pp. 825-832
    • Song, H.K.1    Dougherty, L.2
  • 11
    • 77954717327 scopus 로고    scopus 로고
    • Gadoxetate disodium-enhanced MRI of the liver: Part 2, protocol pptimization and lesion appearance in the cirrhotic liver
    • 20566795 10.2214/AJR.10.4538
    • Cruite I, Schroeder M, Merkle EM, Sirlin CB (2010) Gadoxetate disodium-enhanced MRI of the liver: Part 2, protocol pptimization and lesion appearance in the cirrhotic liver. AJR Am J Roentgenol 195:29-41
    • (2010) AJR Am J Roentgenol , vol.195 , pp. 29-41
    • Cruite, I.1    Schroeder, M.2    Merkle, E.M.3    Sirlin, C.B.4
  • 12
    • 78650805205 scopus 로고    scopus 로고
    • Gadoxetate disodium-enhanced hepatic MRI: Dose-dependent contrast dynamics of hepatic parenchyma and portal vein
    • 21178026 10.2214/AJR.10.4387
    • Feuerlein S, Boll DT, Gupta RT, Ringe KI, Marin D, Merkle EM (2011) Gadoxetate disodium-enhanced hepatic MRI: Dose-dependent contrast dynamics of hepatic parenchyma and portal vein. AJR Am J Roentgenol 196:W18-24
    • (2011) AJR Am J Roentgenol , vol.196 , pp. 18-24
    • Feuerlein, S.1    Boll, D.T.2    Gupta, R.T.3    Ringe, K.I.4    Marin, D.5    Merkle, E.M.6
  • 13
    • 77954735667 scopus 로고    scopus 로고
    • Gadoxetate disodium-enhanced MRI of the liver: Part 1, protocol optimization and lesion appearance in the noncirrhotic liver
    • 20566794 10.2214/AJR.10.4392
    • Ringe KI, Husarik DB, Sirlin CB, Merkle EM (2010) Gadoxetate disodium-enhanced MRI of the liver: Part 1, protocol optimization and lesion appearance in the noncirrhotic liver. AJR Am J Roentgenol 195:13-28
    • (2010) AJR Am J Roentgenol , vol.195 , pp. 13-28
    • Ringe, K.I.1    Husarik, D.B.2    Sirlin, C.B.3    Merkle, E.M.4
  • 14
    • 84857089420 scopus 로고    scopus 로고
    • Liver MRI in the hepatocyte phase with gadolinium-EOB-DTPA: Does increasing the flip angle improve conspicuity and detection rate of hypointense lesions?
    • 22034383 10.1002/jmri.22850
    • Bashir MR, Husarik DB, Ziemlewicz TJ, Gupta RT, Boll DT, Merkle EM (2012) Liver MRI in the hepatocyte phase with gadolinium-EOB-DTPA: Does increasing the flip angle improve conspicuity and detection rate of hypointense lesions? J Magn Reson Imaging 35:611-616
    • (2012) J Magn Reson Imaging , vol.35 , pp. 611-616
    • Bashir, M.R.1    Husarik, D.B.2    Ziemlewicz, T.J.3    Gupta, R.T.4    Boll, D.T.5    Merkle, E.M.6
  • 15
    • 80051944539 scopus 로고    scopus 로고
    • Optimized high-resolution contrast-enhanced hepatobiliary imaging at 3 tesla: A cross-over comparison of gadobenate dimeglumine and gadoxetic acid
    • 21751288 10.1002/jmri.22713
    • Frydrychowicz A, Nagle SK, D'Souza SL, Vigen KK, Reeder SB (2011) Optimized high-resolution contrast-enhanced hepatobiliary imaging at 3 tesla: A cross-over comparison of gadobenate dimeglumine and gadoxetic acid. J Magn Reson Imaging 34:585-594
    • (2011) J Magn Reson Imaging , vol.34 , pp. 585-594
    • Frydrychowicz, A.1    Nagle, S.K.2    D'Souza, S.L.3    Vigen, K.K.4    Reeder, S.B.5
  • 16
    • 0017360990 scopus 로고
    • The measurement of observer agreement for categorical data
    • 843571 10.2307/2529310 1:STN:280:DyaE2s7jsFWqtA%3D%3D
    • Landis JR, Koch GG (1977) The measurement of observer agreement for categorical data. Biometrics 33:159-174
    • (1977) Biometrics , vol.33 , pp. 159-174
    • Landis, J.R.1    Koch, G.G.2
  • 17
    • 42949126590 scopus 로고    scopus 로고
    • Water excitation MPRAGE: An alternative sequence for postcontrast imaging of the abdomen in noncooperative patients at 1.5 Tesla and 3.0 Tesla MRI
    • 18425826 10.1002/jmri.21346
    • Altun E, Semelka RC, Dale BM, Elias J Jr (2008) Water excitation MPRAGE: An alternative sequence for postcontrast imaging of the abdomen in noncooperative patients at 1.5 Tesla and 3.0 Tesla MRI. J Magn Reson Imaging 27:1146-1154
    • (2008) J Magn Reson Imaging , vol.27 , pp. 1146-1154
    • Altun, E.1    Semelka, R.C.2    Dale, B.M.3    Elias, Jr.J.4
  • 18
    • 84858284448 scopus 로고    scopus 로고
    • Clinical usefulness of free-breathing navigator-triggered 3D MRCP in non-cooperative patients: Comparison with conventional breath-hold 2D MRCP
    • 21700409 10.1016/j.ejrad.2011.06.004
    • Kim JH, Hong SS, Eun HW, Han JK, Choi BI (2012) Clinical usefulness of free-breathing navigator-triggered 3D MRCP in non-cooperative patients: Comparison with conventional breath-hold 2D MRCP. Eur J Radiol 81:e513-518
    • (2012) Eur J Radiol , vol.81 , pp. 513-518
    • Kim, J.H.1    Hong, S.S.2    Eun, H.W.3    Han, J.K.4    Choi, B.I.5
  • 19
    • 53249155042 scopus 로고    scopus 로고
    • MRI artifact reduction and quality improvement in the upper abdomen with PROPELLER and prospective acquisition correction (PACE) technique
    • 18806158 10.2214/AJR.07.3657
    • Hirokawa Y, Isoda H, Maetani YS, Arizono S, Shimada K, Togashi K (2008) MRI artifact reduction and quality improvement in the upper abdomen with PROPELLER and prospective acquisition correction (PACE) technique. AJR Am J Roentgenol 191:1154-1158
    • (2008) AJR Am J Roentgenol , vol.191 , pp. 1154-1158
    • Hirokawa, Y.1    Isoda, H.2    Maetani, Y.S.3    Arizono, S.4    Shimada, K.5    Togashi, K.6
  • 20
    • 79953019185 scopus 로고    scopus 로고
    • Breath-hold T2-weighted MRI of the liver at 3T using the BLADE technique: Impact upon image quality and lesion detection
    • 21300326 10.1016/j.crad.2010.10.018 1:STN:280:DC%2BC3M3ptl2itA%3D%3D
    • Rosenkrantz AB, Mannelli L, Mossa D, Babb JS (2011) Breath-hold T2-weighted MRI of the liver at 3T using the BLADE technique: Impact upon image quality and lesion detection. Clin Radiol 66:426-433
    • (2011) Clin Radiol , vol.66 , pp. 426-433
    • Rosenkrantz, A.B.1    Mannelli, L.2    Mossa, D.3    Babb, J.S.4
  • 21
    • 66149086161 scopus 로고    scopus 로고
    • Hepatic lesions: Improved image quality and detection with the periodically rotated overlapping parallel lines with enhanced reconstruction technique - Evaluation of SPIO-enhanced T2-weighted MR images
    • 19401572 10.1148/radiol.2512081360
    • Hirokawa Y, Isoda H, Maetani YS et al (2009) Hepatic lesions: Improved image quality and detection with the periodically rotated overlapping parallel lines with enhanced reconstruction technique - evaluation of SPIO-enhanced T2-weighted MR images. Radiology 251:388-397
    • (2009) Radiology , vol.251 , pp. 388-397
    • Hirokawa, Y.1    Isoda, H.2    Maetani, Y.S.3
  • 22
    • 53549091578 scopus 로고    scopus 로고
    • Evaluation of motion correction effect and image quality with the periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) (BLADE) and parallel imaging acquisition technique in the upper abdomen
    • 18821630 10.1002/jmri.21538
    • Hirokawa Y, Isoda H, Maetani YS, Arizono S, Shimada K, Togashi K (2008) Evaluation of motion correction effect and image quality with the periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) (BLADE) and parallel imaging acquisition technique in the upper abdomen. J Magn Reson Imaging 28:957-962
    • (2008) J Magn Reson Imaging , vol.28 , pp. 957-962
    • Hirokawa, Y.1    Isoda, H.2    Maetani, Y.S.3    Arizono, S.4    Shimada, K.5    Togashi, K.6
  • 24
    • 17544375313 scopus 로고    scopus 로고
    • The impact of 3-dimensional reconstructions on operation planning in liver surgery
    • 11074877 10.1001/archsurg.135.11.1256 1:STN:280:DC%2BD3M%2FkslKnsA%3D%3D
    • Lamade W, Glombitza G, Fischer L et al (2000) The impact of 3-dimensional reconstructions on operation planning in liver surgery. Arch Surg 135:1256-1261
    • (2000) Arch Surg , vol.135 , pp. 1256-1261
    • Lamade, W.1    Glombitza, G.2    Fischer, L.3
  • 25
    • 84866349186 scopus 로고    scopus 로고
    • High resolution navigated three-dimensional T(1)-weighted hepatobiliary MRI using gadoxetic acid optimized for 1.5 Tesla
    • 22648633 10.1002/jmri.23713
    • Nagle SK, Busse RF, Brau AC et al (2012) High resolution navigated three-dimensional T(1)-weighted hepatobiliary MRI using gadoxetic acid optimized for 1.5 Tesla. J Magn Reson Imaging 36:890-899
    • (2012) J Magn Reson Imaging , vol.36 , pp. 890-899
    • Nagle, S.K.1    Busse, R.F.2    Brau, A.C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.