메뉴 건너뛰기




Volumn 146, Issue 5, 2013, Pages 1047-1054

Early clinical outcome of aortic transcatheter valve-in-valve implantation in the Nordic countries

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; AORTA VALVE REGURGITATION; AORTA VALVE STENOSIS; ARTICLE; ASPIRATION PNEUMONIA; CARDIOVASCULAR MORTALITY; CEREBROVASCULAR ACCIDENT; CLINICAL ARTICLE; EUROSCORE; EUROSCORE II; FEMALE; FOLLOW UP; HEART INFARCTION; HUMAN; MALE; PARAVALVULAR LEAKAGE; POST TREATMENT SURVIVAL; POSTOPERATIVE COMPLICATION; PRIORITY JOURNAL; PROSTHESIS FAILURE; SCORING SYSTEM; SOCIETY OF THORACIC SURGEONS SCORE; SURGICAL MORTALITY; SURVIVAL RATE; SURVIVAL TIME; TRANSCATHETER AORTIC VALVE IMPLANTATION; TRANSCATHETER AORTIC VALVE IN VALVE IMPLANTATION; TREATMENT OUTCOME; VASCULAR DISEASE;

EID: 84885946445     PISSN: 00225223     EISSN: 1097685X     Source Type: Journal    
DOI: 10.1016/j.jtcvs.2013.06.045     Document Type: Article
Times cited : (28)

References (19)
  • 1
    • 58249086539 scopus 로고    scopus 로고
    • Isolated aortic valve replacement in North America comprising 108,687 patients in 10 years: Changes in risks, valve types, and outcomes in the Society of Thoracic Surgeons National Database
    • J.M. Brown, S.M. O'Brien, C. Wu, J.A. Sikora, B.P. Griffith, and J.S. Gammie Isolated aortic valve replacement in North America comprising 108,687 patients in 10 years: changes in risks, valve types, and outcomes in the Society of Thoracic Surgeons National Database J Thorac Cardiovasc Surg 137 2009 82 90
    • (2009) J Thorac Cardiovasc Surg , vol.137 , pp. 82-90
    • Brown, J.M.1    O'Brien, S.M.2    Wu, C.3    Sikora, J.A.4    Griffith, B.P.5    Gammie, J.S.6
  • 3
    • 77957166547 scopus 로고    scopus 로고
    • Reoperative valve surgery in the elderly: Predictors of risk and long-term survival
    • discussion 1201
    • L.B. Balsam, E.A. Grossi, D.G. Greenhouse, P. Ursomanno, A. Deanda, and G.H. Ribakove Reoperative valve surgery in the elderly: predictors of risk and long-term survival Ann Thorac Surg 90 2010 1195 1200 discussion 1201
    • (2010) Ann Thorac Surg , vol.90 , pp. 1195-1200
    • Balsam, L.B.1    Grossi, E.A.2    Greenhouse, D.G.3    Ursomanno, P.4    Deanda, A.5    Ribakove, G.H.6
  • 5
    • 36348952550 scopus 로고    scopus 로고
    • Percutaneous aortic valve replacement for severe aortic regurgitation in degenerated bioprosthesis: The first valve in valve procedure using the CoreValve revalving system
    • P. Wenaweser, L. Buellesfeld, U. Gerckens, and E. Grube Percutaneous aortic valve replacement for severe aortic regurgitation in degenerated bioprosthesis: the first valve in valve procedure using the CoreValve revalving system Catheter Cardiovasc Interv 70 2007 760 764
    • (2007) Catheter Cardiovasc Interv , vol.70 , pp. 760-764
    • Wenaweser, P.1    Buellesfeld, L.2    Gerckens, U.3    Grube, E.4
  • 6
    • 77951767167 scopus 로고    scopus 로고
    • Transcatheter valve-in-valve implantation for failed bioprosthetic heart valves
    • J.G. Webb, D.A. Wood, J. Ye, R. Gurvitch, J.B. Masson, and J. Rodes-Cabau Transcatheter valve-in-valve implantation for failed bioprosthetic heart valves Circulation 121 2010 1848 1857
    • (2010) Circulation , vol.121 , pp. 1848-1857
    • Webb, J.G.1    Wood, D.A.2    Ye, J.3    Gurvitch, R.4    Masson, J.B.5    Rodes-Cabau, J.6
  • 7
    • 73049102176 scopus 로고    scopus 로고
    • Transcatheter aortic valve implantation for stenosed and regurgitant aortic valve bioprostheses: CoreValve for failed bioprosthetic aortic valve replacements
    • M.Z. Khawaja, P. Haworth, A. Ghuran, L. Lee, A. de Belder, and N. Hutchinson Transcatheter aortic valve implantation for stenosed and regurgitant aortic valve bioprostheses: CoreValve for failed bioprosthetic aortic valve replacements J Am Coll Cardiol 55 2010 97 101
    • (2010) J Am Coll Cardiol , vol.55 , pp. 97-101
    • Khawaja, M.Z.1    Haworth, P.2    Ghuran, A.3    Lee, L.4    De Belder, A.5    Hutchinson, N.6
  • 8
    • 77952316738 scopus 로고    scopus 로고
    • Transapical off-pump valve-in-valve implantation in patients with degenerated aortic xenografts
    • J. Kempfert, A. Van Linden, A. Linke, M.A. Borger, A. Rastan, and C. Mukherjee Transapical off-pump valve-in-valve implantation in patients with degenerated aortic xenografts Ann Thorac Surg 89 2010 1934 1941
    • (2010) Ann Thorac Surg , vol.89 , pp. 1934-1941
    • Kempfert, J.1    Van Linden, A.2    Linke, A.3    Borger, M.A.4    Rastan, A.5    Mukherjee, C.6
  • 9
    • 70349087320 scopus 로고    scopus 로고
    • "Valve-in-valve" implantation in a patient with stentless bioprosthesis and severe intraprosthetic aortic regurgitation
    • D. Attias, D. Himbert, U. Hvass, and A. Vahanian "Valve-in- valve" implantation in a patient with stentless bioprosthesis and severe intraprosthetic aortic regurgitation J Thorac Cardiovasc Surg 138 2009 1020 1022
    • (2009) J Thorac Cardiovasc Surg , vol.138 , pp. 1020-1022
    • Attias, D.1    Himbert, D.2    Hvass, U.3    Vahanian, A.4
  • 10
    • 84867774923 scopus 로고    scopus 로고
    • Transaortic valve-in-valve implantation after previous aortic root homograft
    • L. Ihlberg, A. Sahlman, J. Sinisalo, J. Rapola, and M. Laine Transaortic valve-in-valve implantation after previous aortic root homograft Ann Thorac Surg 94 2012 1718 1721
    • (2012) Ann Thorac Surg , vol.94 , pp. 1718-1721
    • Ihlberg, L.1    Sahlman, A.2    Sinisalo, J.3    Rapola, J.4    Laine, M.5
  • 11
    • 84879420397 scopus 로고    scopus 로고
    • A guide to fluoroscopic identification and design of bioprosthetic heart valves: A reference for valve-in-valve procedure
    • V. Bapat, I. Mydin, S. Chadalavada, H. Tehrani, R. Attia, and M. Thomas A guide to fluoroscopic identification and design of bioprosthetic heart valves: a reference for valve-in-valve procedure Catheter Cardiovasc Interv 81 2013 853 861
    • (2013) Catheter Cardiovasc Interv , vol.81 , pp. 853-861
    • Bapat, V.1    Mydin, I.2    Chadalavada, S.3    Tehrani, H.4    Attia, R.5    Thomas, M.6
  • 12
    • 0032812802 scopus 로고    scopus 로고
    • Risk factors and outcome in European cardiac surgery: Analysis of the EuroSCORE multinational database of 19030 patients
    • discussion 822-3
    • F. Roques, S.A. Nashef, P. Michel, E. Gauducheau, C. de Vincentiis, and E. Baudet Risk factors and outcome in European cardiac surgery: analysis of the EuroSCORE multinational database of 19030 patients Eur J Cardiothorac Surg 15 1999 816 822 discussion 822-3
    • (1999) Eur J Cardiothorac Surg , vol.15 , pp. 816-822
    • Roques, F.1    Nashef, S.A.2    Michel, P.3    Gauducheau, E.4    De Vincentiis, C.5    Baudet, E.6
  • 13
    • 78651337155 scopus 로고    scopus 로고
    • Standardized endpoint definitions for transcatheter aortic valve implantation clinical trials: A consensus report from the Valve Academic Research Consortium
    • M.B. Leon, N. Piazza, E. Nikolsky, E.H. Blackstone, D.E. Cutlip, and A.P. Kappetein Standardized endpoint definitions for transcatheter aortic valve implantation clinical trials: a consensus report from the Valve Academic Research Consortium J Am Coll Cardiol 57 2011 253 269
    • (2011) J Am Coll Cardiol , vol.57 , pp. 253-269
    • Leon, M.B.1    Piazza, N.2    Nikolsky, E.3    Blackstone, E.H.4    Cutlip, D.E.5    Kappetein, A.P.6
  • 14
    • 84868523264 scopus 로고    scopus 로고
    • Transcatheter aortic valve replacement for degenerative bioprosthetic surgical valves: Results from the Global Valve-in-Valve Registry
    • D. Dvir, J. Webb, S. Brecker, S. Bleiziffer, D. Hildick-Smith, and A. Colombo Transcatheter aortic valve replacement for degenerative bioprosthetic surgical valves: results from the Global Valve-in-Valve Registry Circulation 126 2012 2335 2344
    • (2012) Circulation , vol.126 , pp. 2335-2344
    • Dvir, D.1    Webb, J.2    Brecker, S.3    Bleiziffer, S.4    Hildick-Smith, D.5    Colombo, A.6
  • 15
    • 84869070091 scopus 로고    scopus 로고
    • Use of transcatheter heart valves for a valve-in-valve implantation in patients with degenerated aortic bioprosthesis: Technical considerations and results
    • V. Bapat, R. Attia, S. Redwood, J. Hancock, K. Wilson, and C. Young Use of transcatheter heart valves for a valve-in-valve implantation in patients with degenerated aortic bioprosthesis: technical considerations and results J Thorac Cardiovasc Surg 144 2012 1372 1380
    • (2012) J Thorac Cardiovasc Surg , vol.144 , pp. 1372-1380
    • Bapat, V.1    Attia, R.2    Redwood, S.3    Hancock, J.4    Wilson, K.5    Young, C.6
  • 16
    • 79960594587 scopus 로고    scopus 로고
    • Transcatheter aortic valve implantation for failing surgical aortic bioprosthetic valve: From concept to clinical application and evaluation (part 2)
    • N. Piazza, S. Bleiziffer, G. Brockmann, R. Hendrik, M.A. Deutsch, and A. Opitz Transcatheter aortic valve implantation for failing surgical aortic bioprosthetic valve: from concept to clinical application and evaluation (part 2) JACC Cardiovasc Interv 4 2011 733 742
    • (2011) JACC Cardiovasc Interv , vol.4 , pp. 733-742
    • Piazza, N.1    Bleiziffer, S.2    Brockmann, G.3    Hendrik, R.4    Deutsch, M.A.5    Opitz, A.6
  • 18
    • 77958594295 scopus 로고    scopus 로고
    • Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery
    • M.B. Leon, C.R. Smith, M. Mack, D.C. Miller, M.W. Moses, and L.G. Svensson Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery N Engl J Med 363 2010 1597 1607
    • (2010) N Engl J Med , vol.363 , pp. 1597-1607
    • Leon, M.B.1    Smith, C.R.2    MacK, M.3    Miller, D.C.4    Moses, M.W.5    Svensson, L.G.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.