메뉴 건너뛰기




Volumn 187, Issue , 2013, Pages 27-32

Determination of l-tryptophan in the presence of ascorbic acid and dopamine using poly(sulfosalicylic acid) modified glassy carbon electrode

Author keywords

Differential pulse voltammetry; Electropolymerization; L Tryptophan; Poly sulfosalicylic acid

Indexed keywords

AMINES; AMINO ACIDS; CYCLIC VOLTAMMETRY; ELECTROCATALYSIS; ELECTROCHEMICAL IMPEDANCE SPECTROSCOPY; ELECTRODES; ELECTROPOLYMERIZATION; GLASS; GLASS MEMBRANE ELECTRODES; INTERFACES (MATERIALS); NEUROPHYSIOLOGY; ORGANIC ACIDS; SCANNING ELECTRON MICROSCOPY; VOLTAMMETRY;

EID: 84885483673     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2012.09.018     Document Type: Article
Times cited : (38)

References (31)
  • 1
    • 27544499713 scopus 로고    scopus 로고
    • Biochemical and medical aspects of the indoleamine 2,3-dioxygenase- initiated L-tryptophan metabolism
    • DOI 10.1016/j.bbrc.2005.09.032, PII S0006291X05020449
    • O. Takikawa, Biochemical and medical aspects of the indoleamine 2 3 dioxygenase-initiated L-tryptophan metabolism, Biochemical and Biophysical Research Communications 338 (2005) 12-19. (Pubitemid 41540531)
    • (2005) Biochemical and Biophysical Research Communications , vol.338 , Issue.1 , pp. 12-19
    • Takikawa, O.1
  • 2
    • 0018104243 scopus 로고
    • Dependence of 5-HT and catecholamine synthesis on concentrations of precursor amino-acids in rat brain
    • A. Carlsson, M. Lindqvist, Dependence of 5-HT and catecholamine synthesis on concentrations of precursor amino-acids in rat brain, Naunyn-Schmiedeberg's Archives of Pharmacology 303 (1978) 157-164. (Pubitemid 8369123)
    • (1978) Naunyn-Schmiedeberg's Archives of Pharmacology , vol.303 , Issue.2 , pp. 157-164
    • Carlsson, A.1    Lindqvist, M.2
  • 3
    • 80955180217 scopus 로고    scopus 로고
    • Electrocatalytic oxidation of L-tryptophan using copper hexacyanoferrate film modified gold nanoparticle graphite-wax electrode
    • P. Prabhu, R.S. Babu, S.S. Narayanan, Electrocatalytic oxidation of L-tryptophan using copper hexacyanoferrate film modified gold nanoparticle graphite-wax electrode, Colloids and Surfaces B: Biointerfaces 87 (2011) 103-108.
    • (2011) Colloids and Surfaces B: Biointerfaces , vol.87 , pp. 103-108
    • Prabhu, P.1    Babu, R.S.2    Narayanan, S.S.3
  • 5
    • 0038201602 scopus 로고    scopus 로고
    • Rapid and direct determination of tryptophan in water using synchronous fluorescence spectroscopy
    • DOI 10.1016/S0043-1354(03)00153-2
    • D.M. Reynolds, Rapid and direct determination of tryptophan in water using synchronous fluorescence spectroscopy, Water Research 37 (2003) 3055-3060. (Pubitemid 36667947)
    • (2003) Water Research , vol.37 , Issue.13 , pp. 3055-3060
    • Reynolds, D.M.1
  • 6
    • 0032969874 scopus 로고    scopus 로고
    • Determination of enantiomeric amino acids with high-performance liquid chromatograpby and pre-column derivatisation with o-phthaldialdehyde and N-isobutyrylcysteine in seawater and fossil samples (mollusks)
    • DOI 10.1016/S0021-9673(98)01000-0, PII S0021967398010000
    • H.P. Fitznar, J.M. Lobbes, G. Kattner, Determination of enantiomeric amino acids with high-performance liquid chromatography and pre-column derivatisation with o-phthaldialdehyde and N-isobutyrylcysteine in seawater and fossil samples (mollusks), Journal of Chromatography A 832 (1999) 123-132. (Pubitemid 29073730)
    • (1999) Journal of Chromatography A , vol.832 , Issue.1-2 , pp. 123-132
    • Fitznar, H.P.1    Lobbes, J.M.2    Kattner, G.3
  • 7
    • 79151472200 scopus 로고    scopus 로고
    • Simultaneous determination of tryptophan, kynurenine and 5-hydroxytryptamine by HPLC: Application in uremic patients undergoing hemodialysis
    • Q. Zhen, B. Xu, L. Ma, G. Tian, X. Tang, M. Ding, Simultaneous determination of tryptophan, kynurenine and 5-hydroxytryptamine by HPLC: application in uremic patients undergoing hemodialysis, Clinical Biochemistry 44 (2011) 226-230.
    • (2011) Clinical Biochemistry , vol.44 , pp. 226-230
    • Zhen, Q.1    Xu, B.2    Ma, L.3    Tian, G.4    Tang, X.5    Ding, M.6
  • 9
    • 31044437965 scopus 로고    scopus 로고
    • Characterization of bovine serum albumin-tryptophan interaction by capillary isoelectric focusing with whole column imaging detection
    • DOI 10.1016/j.chroma.2005.08.092, PII S0021967305017772
    • T. Bo, J. Pawliszyn, Characterization of bovine serum albumin-tryptophan interaction by capillary isoelectric focusing with whole column imaging detection, Journal of Chromatography A 1105 (2006) 25-32. (Pubitemid 43122042)
    • (2006) Journal of Chromatography A , vol.1105 , Issue.SPEC. ISS. 1-2 , pp. 25-32
    • Bo, T.1    Pawliszyn, J.2
  • 10
    • 75749094696 scopus 로고    scopus 로고
    • Electrochemical determination of ltryptophan, L-tyrosine and L-cysteine using electrospun carbon nanofibers modified electrode
    • X.F. Tang, Y. Liu, H.Q. Hou, T.Y. You, Electrochemical determination of Ltryptophan, L-tyrosine and L-cysteine using electrospun carbon nanofibers modified electrode, Talanta 80 (2010) 2182-2186.
    • (2010) Talanta , vol.80 , pp. 2182-2186
    • Tang, X.F.1    Liu, Y.2    Hou, H.Q.3    You, T.Y.4
  • 11
    • 0030703007 scopus 로고    scopus 로고
    • Electrochemical oxidation reactions of tyrosine, tryptophan and related dipeptides
    • PII S001346869600285X
    • S.M. MacDonald, S.G. Roscoe, Electrochemical oxidation reactions of tyrosine, tryptophan and related dipeptides, Electrochimica Acta 42 (1997) 1189-1200. (Pubitemid 127411855)
    • (1997) Electrochimica Acta , vol.42 , Issue.8 , pp. 1189-1200
    • Macdonald, S.M.1    Roscoe, S.G.2
  • 12
    • 70349299820 scopus 로고    scopus 로고
    • Electrochemical behavior and voltammetric determination of tryptophan based on 4-aminobenzoic acid polymer film modified glassy carbon electrode
    • K.J. Huang, C.X. Xu, W.Z. Xie, W. Wang, Electrochemical behavior and voltammetric determination of tryptophan based on 4-aminobenzoic acid polymer film modified glassy carbon electrode, Colloids and Surfaces B: Biointerfaces 74 (2009)167-171.
    • (2009) Colloids and Surfaces B: Biointerfaces , vol.74 , pp. 167-171
    • Huang, K.J.1    Xu, C.X.2    Xie, W.Z.3    Wang, W.4
  • 13
    • 80051812171 scopus 로고    scopus 로고
    • Poly-glutamic acid modified carbon nanotube-doped carbon paste electrode forsensitive detection of L-tryptophan
    • X. Liu, L.Q. Luo, Y.P. Ding, D.X. Ye, Poly-glutamic acid modified carbon nanotube-doped carbon paste electrode forsensitive detection of L-tryptophan, Bioelectrochemistry 82 (2011)38-45.
    • (2011) Bioelectrochemistry , vol.82 , pp. 38-45
    • Liu, X.1    Luo, L.Q.2    Ding, Y.P.3    Ye, D.X.4
  • 14
    • 54549113181 scopus 로고    scopus 로고
    • Carbon paste electrode incorporating 1-[4-(ferrocenyl ethynyl) phenyl]-1-ethanone forelectrocatalytic and voltammetric determination oftryptophan
    • J.-B. Raoof, R. Ojani, H. Karimi-Maleh, Carbon paste electrode incorporating 1-[4-(ferrocenyl ethynyl) phenyl]-1-ethanone forelectrocatalytic and voltammetric determination oftryptophan, Electroanalysis 20 (2008) 1259-1262.
    • (2008) Electroanalysis , vol.20 , pp. 1259-1262
    • Raoof, J.-B.1    Ojani, R.2    Karimi-Maleh, H.3
  • 15
    • 79954621209 scopus 로고    scopus 로고
    • A nano-structured ni(II)-ACDA modified gold nanoparticle self-assembled electrode for electrocatalytic oxidation and determination oftryptophan
    • M.B. Gholivand, A. Pashabadi, A. Azadbakht, S. Menati, A nano-structured Ni(II)-ACDA modified gold nanoparticle self-assembled electrode for electrocatalytic oxidation and determination oftryptophan, Electrochimica Acta 56 (2011)4022-4030.
    • (2011) Electrochimica Acta , vol.56 , pp. 4022-4030
    • Gholivand, M.B.1    Pashabadi, A.2    Azadbakht, A.3    Menati, S.4
  • 16
    • 74149091903 scopus 로고    scopus 로고
    • Electrochemical investigation oftryptophan at gold nanoparticles modified electrode in the presence of sodium dodecylbenzene sulfonate
    • C.Y. Li, Y. Ya, G.Q. Zhan, Electrochemical investigation oftryptophan at gold nanoparticles modified electrode in the presence of sodium dodecylbenzene sulfonate, Colloids and Surfaces B: Biointerfaces 76 (2010) 340-345.
    • (2010) Colloids and Surfaces B: Biointerfaces , vol.76 , pp. 340-345
    • Li, C.Y.1    Ya, Y.2    Zhan, G.Q.3
  • 18
    • 0000141802 scopus 로고
    • Electrochemical polymerization of aromatic amines: Ir, XPS and PMT study of thin film formation on a pt electrode
    • A. Volkov, G. Tourillon, P.C. Lacaze, J.E. Dubois, Electrochemical polymerization of aromatic amines: IR, XPS and PMT study of thin film formation on a Pt electrode, Journal of Electroanalytical Chemistry 115 (1980) 279-291.
    • (1980) Journal of Electroanalytical Chemistry , vol.115 , pp. 279-291
    • Volkov, A.1    Tourillon, G.2    Lacaze, P.C.3    Dubois, J.E.4
  • 19
    • 0002001083 scopus 로고
    • Immobilization of metalloporphyrins in electropolymerized films: Design and applications
    • F. Bedioui, J. Devynck, C. Bied-Charreton, Immobilization of metalloporphyrins in electropolymerized films: design and applications, Accounts of Chemical Research 28 (1995) 30-36.
    • (1995) Accounts of Chemical Research , vol.28 , pp. 30-36
    • Bedioui, F.1    Devynck, J.2    Bied-Charreton, C.3
  • 20
    • 78650586809 scopus 로고    scopus 로고
    • Conductive polymer-based sensors for biomedical applications
    • S. Nambiar, J.T.W. Yeow, Conductive polymer-based sensors for biomedical applications, Biosensors and Bioelectronics 26 (2011) 1825-1832.
    • (2011) Biosensors and Bioelectronics , vol.26 , pp. 1825-1832
    • Nambiar, S.1    Yeow, J.T.W.2
  • 21
    • 2942649328 scopus 로고    scopus 로고
    • Electrocatalysis on polymer-modified electrodes
    • DOI 10.1070/RC2002v071n10ABEH000672
    • B.I. Podlovchenko, V.N. Andreev, Electrocatalysis on polymer-modified electrodes, Russian Chemical Reviews 71 (2002) 837-851. (Pubitemid 44339497)
    • (2002) Russian Chemical Reviews , vol.71 , Issue.10 , pp. 837-851
    • Podlovchenko, B.I.1    Andreev, V.N.2
  • 22
    • 84862781825 scopus 로고    scopus 로고
    • Simultaneous and sensitive voltammetric determination of acetaminophen and its degradation product for pharmaceutical quality control and pharmacokinetic research by using ultrathin poly (calconcarboxylic acid) film modified glassy carbon electrode
    • A. Liu, K. Wang, W. Chen, F. Gao, Simultaneous and sensitive voltammetric determination of acetaminophen and its degradation product for pharmaceutical quality control and pharmacokinetic research by using ultrathin poly (calconcarboxylic acid) film modified glassy carbon electrode, Electrochimica Acta 63 (2012) 161-168.
    • (2012) Electrochimica Acta , vol.63 , pp. 161-168
    • Liu, A.1    Wang, K.2    Chen, W.3    Gao, F.4
  • 23
    • 18544364476 scopus 로고    scopus 로고
    • Poly(p-aminobenzene sulfonic acid)-modified glassy carbon electrode for simultaneous detection of dopamine and ascorbic acid
    • G.Y. Jin, Y.Z. Zhang, W.X. Cheng, Poly(p-aminobenzene sulfonic acid)-modified glassy carbon electrode for simultaneous detection of dopamine and ascorbic acid, Sensors and Actuators B: Chemical 107 (2005) 528-534.
    • (2005) Sensors and Actuators B: Chemical , vol.107 , pp. 528-534
    • Jin, G.Y.1    Zhang, Y.Z.2    Cheng, W.X.3
  • 24
    • 41549116856 scopus 로고    scopus 로고
    • Simultaneous voltammetric determination of norepinephrine, ascorbic acid and uric acid on polycalconcarboxylic acid modified glassy carbon electrode
    • A. Liu, S.B. Zhang, W. Chen, Simultaneous voltammetric determination of norepinephrine, ascorbic acid and uric acid on polycalconcarboxylic acid modified glassy carbon electrode, Biosensors and Bioelectronics 23 (2008) 1488-1495.
    • (2008) Biosensors and Bioelectronics , vol.23 , pp. 1488-1495
    • Liu, A.1    Zhang, S.B.2    Chen, W.3
  • 25
    • 70350513279 scopus 로고    scopus 로고
    • Electrochemical determination of L-dopa in the presence of ascorbic acid on the surface of the glassy carbon electrode modified by a bilayer of multi-walled carbon nanotube and poly-pyrrole doped with tiron
    • S. Shahrokhian, E. Asadian, Electrochemical determination of L-dopa in the presence of ascorbic acid on the surface of the glassy carbon electrode modified by a bilayer of multi-walled carbon nanotube and poly-pyrrole doped with tiron, Journal of Electroanalytical Chemistry 636 (2009) 40-46.
    • (2009) Journal of Electroanalytical Chemistry , vol.636 , pp. 40-46
    • Shahrokhian, S.1    Asadian, E.2
  • 27
    • 0037060025 scopus 로고    scopus 로고
    • Electrochemical behavior oftryptophan and its derivatives at a glassy carbon electrode modified with hemin
    • G.N. Chen, Z.F. Zhao, X.L. Wang, J.P. Duan, H.Q. Chen, Electrochemical behavior oftryptophan and its derivatives at a glassy carbon electrode modified with hemin, Analytica Chimica Acta 452 (2002) 245-254.
    • (2002) Analytica Chimica Acta , vol.452 , pp. 245-254
    • Chen, G.N.1    Zhao, Z.F.2    Wang, X.L.3    Duan, J.P.4    Chen, H.Q.5
  • 28
    • 33847017256 scopus 로고    scopus 로고
    • Electrocatalytic oxidation and determination of dopamine in the presence of ascorbic acid and uric acid at a poly (p-nitrobenzenazo resorcinol) modified glassy carbon electrode
    • DOI 10.1016/j.snb.2006.06.004, PII S092540050600431X
    • X.H. Lin, Y.F. Zhang, W. Chen, P. Wu, Electrocatalytic oxidation and determination of dopamine in the presence of ascorbic acid and uric acid at a poly (p-nitrobenzenazo resorcinol) modified glassy carbon electrode, Sensors and Actuators B: Chemical 122 (2007)309-314. (Pubitemid 46275426)
    • (2007) Sensors and Actuators, B: Chemical , vol.122 , Issue.1 , pp. 309-314
    • Lin, X.1    Zhang, Y.2    Chen, W.3    Wu, P.4
  • 29
    • 76449087725 scopus 로고    scopus 로고
    • Amperometric nonenzymatic determination of glucose free of interference based on poly(sulfosalicylic acid) modified nickel microelectrode
    • J.P. Li, J.G. Yu, Q.Y. Lin, Amperometric nonenzymatic determination of glucose free of interference based on poly(sulfosalicylic acid) modified nickel microelectrode, Analytical Letters 43 (2010) 631-643.
    • (2010) Analytical Letters , vol.43 , pp. 631-643
    • Li, J.P.1    Yu, J.G.2    Lin, Q.Y.3
  • 30
    • 0037060025 scopus 로고    scopus 로고
    • Electrochemical behavior of tryptophan and its derivatives at a glassy carbon electrode modified with hemin
    • DOI 10.1016/S0003-2670(01)01470-2, PII S0003267001014702
    • CG. Nan, Z.Z. Feng, W.X. Li, D.J. Ping, C.H. Qin, Electrochemical behavior oftryptophan and its derivatives at a glassy carbon electrode modified with hemin, Analytica Chimica Acta 452 (2002) 245-254. (Pubitemid 34135984)
    • (2002) Analytica Chimica Acta , vol.452 , Issue.2 , pp. 245-254
    • Nan, C.G.1    Feng, Z.Z.2    Li, W.X.3    Ping, D.J.4    Qin, C.H.5
  • 31
    • 84862175678 scopus 로고    scopus 로고
    • 4 nanoparticles-decorated graphene composite for determination of L-tryptophan
    • 4 nanoparticles-decorated graphene composite for determination of L-tryptophan, Analyst 137 (2012) 2840-2845.
    • (2012) Analyst , vol.137 , pp. 2840-2845
    • Ye, D.X.1    Luo, L.Q.2    Ding, Y.P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.